Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Abdom Radiol (NY) ; 44(10): 3398-3407, 2019 10.
Article in English | MEDLINE | ID: mdl-31435761

ABSTRACT

PURPOSE: To compare the performance US and MR in identifying placental adhesion spectrum (PAS) in placenta previa (PP) and to establish a potential method of image interpretation. METHODS: US and MR examinations of 51 patients with PP were selected. The presence of imaging signs commonly used to detect PAS was assessed. Penalized logistic regression was performed considering histology as standard of reference; only signs statistically significant (p < 0.05) were considered for ROC and multivariate analysis. The probability of PAS according to the presence of US and/or MR signs was then assessed. RESULTS: At univariate analysis, loss of retroplacental clear space, myometrial thinning (MT) and placenta lacunar spaces on US, intraplacental dark bands (IDBs), focal interruption of myometrial border (FIMB) and abnormal vascularity (AV) on MR were statistically significant (p < 0.01). Three diagnostic methods for PAS were then developed for both US and MR when at least one (Method 1), two (Method 2) or three (Method 3) imaging signs occurred, respectively. Method 2 for MR showed a significantly (p < 0.05) higher accuracy (91%) compared to the other methods. When MR IDBs and AV as well as IDBs and FIMB were present in combination with US MT the probability of PAS increased from 75 to 90% and from 80 to 91%, respectively. CONCLUSION: MR demonstrated a higher diagnostic accuracy than US to detect PAS. However, since the combination of MR and US signs could improve the probability to detect PAS, a complementary diagnostic role of these techniques could be considered.


Subject(s)
Magnetic Resonance Imaging/methods , Placenta Previa/diagnostic imaging , Tissue Adhesions/diagnostic imaging , Ultrasonography, Prenatal/methods , Adult , Contrast Media , Female , Humans , Image Interpretation, Computer-Assisted , Middle Aged , Pregnancy
2.
Eur J Radiol ; 106: 77-84, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30150055

ABSTRACT

OBJECTIVE: To evaluate MRI accuracy in assessing placental adhesion disorders (PAD) in patients with placenta previa correlating imaging results with histological findings. MATERIALS AND METHODS: Sixty-one patients who underwent abdomino-pelvic magnetic resonance imaging (MRI) for ultrasound suspicion of PAD were prospectively evaluated. T1- and T2-weighted images, with and without fat suppression, were obtained in the three conventional planes using a 1.5 T MRI scanner. MRI accuracy to evaluate the presence of PAD was assessed on the basis of the occurrence of the following abnormal MRI signs: 1) intraplacental dark bands; 2) focal interruption of myometrial border; 3) intraplacental abnormal vascularity; 4) uterine bulging; 5) tenting of the bladder and/or 6) direct visualization of adjacent tissues invasion only in case of percretism. Imaging results were classified as suggestive or not of PAD using histological data as standard of reference; two methods of imaging analysis were used represented by the presence of at least one (Method A) or two (Method B) abnormal MRI signs; the correlation between the presence of each abnormal MRI sign of PAD and the corresponding histological finding was also assessed. RESULTS: The accuracy, as the area under the receiver operating characteristic curve, was significantly (p = 0.001) higher for Method B (0.92, C.I. 95%: 0.82-0.97) compared to Method A (0.764, C.I. 95%: 0.64-0.86). Among the abnormal MRI signs, intraplacental dark bands and focal interruption of myometrial border were those highly correlated with histological proof of PAD (ρ > 0.71, p < 0.001, for both); as result, a modified version of Method B (Method C) was identified considering as criterion for PAD the combined presence of the two abnormal MRI signs highly correlated with histologically proven PAD; however, the accuracy of Method C was significantly (p = 0.005) lower (0.80, C.I. 95%: 0.67-0.89) than Method B and comparable to Method A. CONCLUSIONS: MRI is a useful imaging technique to assess PAD in patients with placenta previa; in particular, the presence of at least two among all the abnormal MRI signs represents the most accurate criterion (Method B) to identify PAD. Although intraplacental dark bands and focal interruption of myometrial border showed the highest correlation with histological proof of PAD as well as this association was the most frequent in PAD, the combination of these latter MRI signs along with other abnormal signs should be considered diagnostic for PAD.


Subject(s)
Placenta Accreta/diagnostic imaging , Placenta Accreta/pathology , Placenta Previa/pathology , Prenatal Diagnosis/methods , Adult , Female , Humans , Magnetic Resonance Imaging/methods , Middle Aged , Myometrium/diagnostic imaging , Myometrium/pathology , Placenta/diagnostic imaging , Placenta/pathology , Pregnancy , Prospective Studies , Reproducibility of Results , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...