Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
1.
Microorganisms ; 12(5)2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38792723

ABSTRACT

Spondylodiscitis is defined by infectious conditions involving the vertebral column. The incidence of the disease has constantly increased over the last decades. Imaging plays a key role in each phase of the disease. Indeed, radiological tools are fundamental in (i) the initial diagnostic recognition of spondylodiscitis, (ii) the differentiation against inflammatory, degenerative, or calcific etiologies, (iii) the disease staging, as well as (iv) to provide clues to orient towards the microorganisms involved. This latter aim can be achieved with a mini-invasive procedure (e.g., CT-guided biopsy) or can be non-invasively supposed by the analysis of the CT, positron emission tomography (PET) CT, or MRI features displayed. Hence, this comprehensive review aims to summarize all the multimodality imaging features of spondylodiscitis. This, with the goal of serving as a reference for Physicians (infectious disease specialists, spine surgeons, radiologists) involved in the care of these patients. Nonetheless, this review article may offer starting points for future research articles.

2.
Nanomicro Lett ; 16(1): 182, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38668830

ABSTRACT

Metal-halide perovskites are revolutionizing the world of X-ray detectors, due to the development of sensitive, fast, and cost-effective devices. Self-powered operation, ensuring portability and low power consumption, has also been recently demonstrated in both bulk materials and thin films. However, the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours, often reporting degradation of the detection performance. Here it is shown that self-powered direct X-ray detectors, fabricated starting from a FAPbBr3 submicrometer-thick film deposition onto a mesoporous TiO2 scaffold, can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss, demonstrating ultra-high operational stability and excellent repeatability. No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy, revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film. In addition, trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy-1 cm-3 at 0 V, an unprecedented value in the field of thin-film-based photoconductors and photodiodes for "hard" X-rays. Finally, prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced.

3.
Eur Spine J ; 33(3): 1028-1043, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38353736

ABSTRACT

PURPOSE: In this study, we analyzed the use of a validated capture system (Spinal Adverse Events Severity system, SAVES V2) as a first non-technical skill to properly face the relevant problem of surgical complications (SCs) and adverse events (AEs) in spinal surgery. METHODS: We retrospectively collected AEs occurring in a tertiary referral center for spine surgery from January 2017 to January 2018 and classified them according to SAVES V2 system. We compared this collection of AEs with a prospective collection performed without any classification system. Univariate and multivariate logistic regression models were used to determined odds ratio (ORs) for selected potential risk factors of AEs and prolonged length of stay. RESULTS: Overall a higher number of AEs was retrospectively recorded using SAVES system compared to the prospective recording without the use of any capture system (97/336 vs 210/336, p < 0.001). The length of stay (LOS) increased in the group of complicated patients for all the procedures examined. In the non-oncological group, LOS was significantly higher for complicated patients compared to uncomplicated patients (F = 44.11, p = 0.0000). Similar results have been obtained in the oncological group of patients. In the multivariate regression model surgical time and postoperative AEs emerged as risk factors for prolonged LOS, while only the presence of previous surgeries was confirmed as risk factor for AEs. CONCLUSION: Considering that the rate of AEs and SCs in spinal surgery is still high despite the improvement of technical skills, we suggest the use of SAVES V2 capture system as a first-line tool to face the problem.


Subject(s)
Postoperative Complications , Spine , Humans , Prospective Studies , Retrospective Studies , Length of Stay , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Spine/surgery
4.
Phys Imaging Radiat Oncol ; 29: 100538, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38317851

ABSTRACT

Accurate dosimetry of ultra-high dose-rate beams using diamond detectors remains challenging, primarily due to the elevated photocurrent peaks exceeding the input dynamics of precision electrometers. This work aimed at demonstrating the effectiveness of compact gated-integration electronics in conditioning the current peaks (>20 mA) generated by a highly sensitive (S ≃ 26 nC/Gy) custom-made diamond photoconductor under electron FLASH irradiation, as well as in real-time monitoring of beam dose and dose-rate. For the emerging FLASH technology, this study provided a new perspective on using commercially available diamond dosimeters with high sensitivity, currently employed in conventional radiotherapy.

5.
Materials (Basel) ; 17(2)2024 Jan 22.
Article in English | MEDLINE | ID: mdl-38276458

ABSTRACT

Orthorhombic κ-Ga2O3 thin films were grown for the first time on polycrystalline diamond free-standing substrates by metal-organic vapor phase epitaxy at a temperature of 650 °C. Structural, morphological, electrical, and photoelectronic properties of the obtained heterostructures were evaluated by optical microscopy, X-ray diffraction, current-voltage measurements, and spectral photoconductivity, respectively. Results show that a very slow cooling, performed at low pressure (100 mbar) under a controlled He flow soon after the growth process, is mandatory to improve the quality of the κ-Ga2O3 epitaxial thin film, ensuring a good adhesion to the diamond substrate, an optimal morphology, and a lower density of electrically active defects. This paves the way for the future development of novel hybrid architectures for UV and ionizing radiation detection, exploiting the unique features of gallium oxide and diamond as wide-bandgap semiconductors.

6.
Global Spine J ; : 21925682231195954, 2023 Aug 10.
Article in English | MEDLINE | ID: mdl-37562976

ABSTRACT

STUDY DESIGN: Retrospective cohort study. OBJECTIVES: This study aimed to investigate the failure of the caudal end of lumbar posterior fixation in terms of pre-operative and post-operative spinopelvic parameters, correction performed, demographic and clinical data. METHODS: The lumbar, thoraco-lumbar and lumbo-sacral posterior fixations performed with pedicle screws and rods in 2017-2019 were retrospectively analyzed. As 81% failures occurred within 4 years, an observational period of 4 years was chosen. The revision surgeries due to the failure in the caudal end were collected in the junctional group. Fixations which have not failed were gathered in the control group. The main spinopelvic parameters were measured for each patient on standing lateral radiographs with the software Surgimap. Demographic and clinical data were extracted for both groups. RESULTS: Among the 457 patients who met the inclusion criteria, the junctional group included 101 patients, who required a revision surgery. The control group collected 356 primary fixations. The two most common causes of revision surgeries were screws pullout (57 cases) and rod breakage (53 cases). SVA, PT, LL, PI-LL and TPA differed significantly between the two groups (P = .021 for LL, P < .0001 for all the others). The interaction between the two groups and the pre-operative and post-operative conditions was significant for PT, SS, LL, TK, PI-LL and TPA (P < .005). Sex and BMI did not affect the failure onset. CONCLUSIONS: Mechanical failure is more likely to occur in patients older than 40 years with a thoraco-lumbar fixation where PT, PI-LL and TPA were not properly restored.

7.
Bioengineering (Basel) ; 10(7)2023 Jul 23.
Article in English | MEDLINE | ID: mdl-37508899

ABSTRACT

CFR-PEEK is gaining popularity in spinal oncological applications due to its reduction of imaging artifacts and radiation scattering compared with titanium, which allows for better oncological follow-up and efficacy of radiotherapy. We evaluated the use of these materials for the treatment of lumbar degenerative diseases (DDs) and considered the biomechanical potential of the carbon fiber in relation to its modulus of elasticity being similar to that of bone. Twenty-eight patients with DDs were treated using CRF-PEEK instrumentation. The clinical and radiographic outcomes were collected at a 12-month FU. Spinal fusion was evaluated in the CT scans using Brantigan scores, while the clinical outcomes were evaluated using VAS, SF-12, and EQ-5D scores. Out of the patients evaluated at the 12-month FU, 89% showed complete or almost certain fusion (Brantigan score D and E) and presented a significant improvement in all clinical parameters; the patients also presented VAS scores ranging from 6.81 ± 2.01 to 0.85 ± 1.32, EQ-5D scores ranging from 53.4 ± 19.3 to 85.0 ± 13.7, SF-12 physical component scores (PCSs) ranging from 29.35 ± 7.04 to 51.36 ± 9.75, and SF-12 mental component scores (MCSs) ranging from 39.89 ± 11.70 to 53.24 ± 9.24. No mechanical complications related to the implant were detected, and the patients reported a better tolerance of the instrumentation compared with titanium. No other series of patients affected by DD that was stabilized using carbon fiber implants have been reported in the literature. The results of this pilot study indicate the efficacy and safety of these implants and support their use also for spinal degenerative diseases.

8.
Diagnostics (Basel) ; 13(12)2023 Jun 16.
Article in English | MEDLINE | ID: mdl-37370988

ABSTRACT

Lung cancer is the second most frequently diagnosed cancer in the world, and surgery is an integral part of the treatment for spinal metastases. The aims of this retrospective study were to assess the overall survival of surgically treated patients affected by lung cancer spinal metastases and identify any factors related to a better survival rate. We recruited 56 consecutive patients (34 male and 22 female) surgically treated for metastatic lung cancer in the spine from 2009 to 2019. Surgical indications were based on a previously published and validated flow chart following a multidisciplinary evaluation. We assessed the localization of vertebral metastases, the presence of other bone or visceral metastases, neurological status according to the Frankel score, ambulatory autonomy, and general status, measured with the Karnofsky performance scale. The expected prognosis was retrospectively assessed according to the revised Tokuhashi score. The median survival was 8.1 months, with over a third of patients surviving more than 1 year. We observed a global improvement in all clinical parameters after surgical treatment. The Tokuhashi predictive score did not correlate with survival after surgery. The results of this study suggest that the surgical treatment of symptomatic spinal metastases from lung cancer can improve quality of life, even in patients with a shorter life expectancy, by controlling pain and improving autonomy.

9.
Materials (Basel) ; 16(2)2023 Jan 14.
Article in English | MEDLINE | ID: mdl-36676560

ABSTRACT

Radiotherapy is now recognized as a pillar in the fight against cancer. Two different types are currently used in clinical practice: (1) external beam radiotherapy, using high-energy X-rays or electron beams, both in the MeV-range, and (2) intraoperative radiotherapy, using low-energy X-rays (up to 50 keV) and MeV-range electron beams. Versatile detectors able to measure the radiation dose independently from the radiation nature and energy are therefore extremely appealing to medical physicists. In this work, a dosimeter based on a high-quality single-crystal synthetic diamond sample was designed, fabricated and characterized under low-energy X-rays, as well as under high-energy pulsed X-rays and electron beams, demonstrating excellent linearity with radiation dose and dose-rate. Detector sensitivity was measured to be 0.299 ± 0.002 µC/Gy under 6 MeV X-ray photons, and 0.298 ± 0.004 µC/Gy under 6 MeV electrons, highlighting that the response of the diamond dosimeter is independent of the radiation nature. Moreover, in the case of low-energy X-rays, an extremely low limit of detection (23 nGy/s) was evaluated, pointing out the suitability of the device to radiation protection dosimetry.

10.
Nanomaterials (Basel) ; 13(2)2023 Jan 05.
Article in English | MEDLINE | ID: mdl-36677993

ABSTRACT

A recent innovation in diamond technology has been the development of the "black diamond" (BD), a material with very high optical absorption generated by processing the diamond surface with a femtosecond laser. In this work, we investigate the optical behavior of the BD samples to prove a near to zero dielectric permittivity in the high electric field condition, where the Frenkel-Poole (FP) effect takes place. Zero-epsilon materials (ENZ), which represent a singularity in optical materials, are expected to lead to remarkable developments in the fields of integrated photonic devices and optical interconnections. Such a result opens the route to the development of BD-based, novel, functional photonic devices.

11.
Nanomaterials (Basel) ; 12(21)2022 Oct 27.
Article in English | MEDLINE | ID: mdl-36364560

ABSTRACT

In this study, we theoretically investigate the response of a germanium thin film under femtosecond pulsed laser irradiation. Electron and lattice temperatures, as well as material-specific optical properties such as dielectric function and reflectivity, were calculated during the irradiation using an extended two-temperature model coupled with the carrier density rate equation and the Drude model. Melting and ablation fluence thresholds were also predicted, resulting in 0.14 J cm-2 and 0.35 J cm-2, respectively. An ultrafast change in both optical and thermal properties was detected upon laser irradiation. Results also indicate that thermal melting occurs after germanium takes on a metallic character during irradiation, and that the impact ionization process may have a critical role in the laser-induced thermal effect. Therefore, we suggest that the origin of the thermal modification of germanium surface under femtosecond laser irradiation is mostly due the impact ionization process and that its effect becomes more important when increasing the laser fluence.

12.
Diagnostics (Basel) ; 12(10)2022 Oct 09.
Article in English | MEDLINE | ID: mdl-36292130

ABSTRACT

Clear cell renal cell carcinoma (ccRCC) usually spreads in the spinal region causing instability or spinal cord compression leading to neurological deficits. Therefore, surgical treatment is required for improving the outcome of patients. The aim of this study is to identify which prognostic factors could affect overall survival in patients affected by ccRCC. Methods: Retrospective cohort study of patients with ccRCC spinal metastases, surgically treated from November 2009 to April 2019. Demographic and clinical data were collected. The Kaplan−Meier method was used to estimate overall survival, and the log-rank test was used to evaluate differences in survival among potentially prognostic factors. Results: A total of 69 patients were surgically treated and followed up for a median period of 65 months. The average age at the time of surgery was 62.6 years old. The median overall survival (OS) was 34.7 months (95% CI 20.8−51.9) and 5-year OS was 31.2% (95% CI 19.2−44.1). A high Tokuhashi score (p = 0.0217), the presence of visceral metastases (p < 0.001), other bone metastases (p = 0.02012) and the kind of surgical treatment (p = 0.0395) are the main prognostic factors that influence the OS. Moreover, 3-year progression-free survival (PFS) was analyzed: the median PFS was 53.1 months and the % 3-year PFS was 62.9% (45.2−76.3). In the multivariate analysis, only pre-operative radiation therapy had a significant impact on 3-year PFS (95% CI 0.929−12.994, p = 0.0643). Conclusion: The results of this study suggest that the absence of visceral metastases and an aggressive surgery as en-bloc, when feasible, could prolong the survival rate and improve quality of life for patients.

13.
J Clin Med ; 11(20)2022 Oct 13.
Article in English | MEDLINE | ID: mdl-36294379

ABSTRACT

The use of three-dimensional (3D)-printed custom-made implants is spreading in the orthopedics field for the reconstruction of bone losses or for joint replacement, thanks to their unparalleled versatility. In particular, this novel technology opens new perspectives to formulate custom-made fixation strategies for the upper cervical region, sacrum and pelvis, where reconstruction is challenging. We report and analyze the literature concerning upper cervical reconstruction with 3D-printed personalized implants after tumor surgery, and discuss two cases of patients where this technology was used to reconstruct the anterior column after extracapsular debulking of C2 recurrent chordoma at our institution.

14.
Nutrients ; 14(20)2022 Oct 13.
Article in English | MEDLINE | ID: mdl-36296959

ABSTRACT

In CKD and in the elderly, Vascular Calcifications (VC) are associated to cardiovascular events and bone fractures. VC scores at the abdominal aorta (AA) from lateral spine radiographs are widely applied (the 0-24 semiquantitative discrete visual score (SV) being the most used). We hypothesised that a novel continuum score based on quantitative computer-assisted tracking of calcifications (QC score) can improve the precision of the SV score. This study tested the repeatability and reproducibility of QC score and SV score. In forty-four patients with VC from an earlier study, five experts from four specialties evaluated the data twice using a dedicated software. Test-retest was performed on eight subjects. QC results were reported in a 0-24 scale to readily compare with SV. The QC score showed higher intra-operator repeatability: the 95% CI of Bland-Altman differences was almost halved in QC; intra-operator R2 improved from 0.67 for SV to 0.79 for QC. Inter-observer repeatability was higher for QC score in the first (Intraclass Correlation Coefficient 0.78 vs. 0.64), but not in the second evaluation (0.84 vs. 0.82), indicating a possible heavier learning artefact for SV. The Minimum Detectable Difference (MDD) was smaller for QC (2.98 vs. 4 for SV, in the 0-24 range). Both scores were insensitive to test-retest procedure. Notably, QC and SV scores were discordant: SV showed generally higher values, and an increasing trend of differences with VC severity. In summary, the new QC score improved the precision of lateral spine radiograph scores in estimating VC. We reported for the first time an estimate of MDD in VC assessment that was 25% lower for the new QC score with respect to the usual SV score. An ongoing study will determine whether this lower MDD may reduce follow-up times to check for VC progression.


Subject(s)
Aorta, Abdominal , Vascular Calcification , Humans , Aged , Aorta, Abdominal/diagnostic imaging , Reproducibility of Results , Tomography, X-Ray Computed/methods , Vascular Calcification/diagnostic imaging , Computers
15.
Curr Oncol ; 29(10): 7842-7857, 2022 10 17.
Article in English | MEDLINE | ID: mdl-36290897

ABSTRACT

En bloc resection consists in the surgical removal of a vertebral tumor in a single piece with a sufficient margin, to improve survival and reduce recurrence rate. This procedure is technically demanding and correlates with a high complication rate. The purpose of this study is to investigate the risk factors for complications in en bloc resection and evaluate if benefits overcome the risks in term of overall survival. We retrospectively analyzed prospectively collected data of patients treated with en bloc resection between 1980 and 2021. Complications were classified according to SAVES-V2. Overall Survival was estimated using Kaplan-Meier method. A total of 149 patients out of 298 (50%) suffered from at least one complication. Moreover, 220 adverse events were collected (67 intraoperative, 82 early post-operative, 71 late post-operative), 54% of these were classified as grade 3 (in a severity scale from 1 to 6). Ten years overall survival was 67% (95% CI 59-74). The occurrence of relapses was associated to an increased risk of mortality with OR 3.4 (95% CI 2.1-5.5), while complications did not affect the overall survival. Despite a high complication rate, en bloc resection allows for a better control of disease and should be performed in selected patients by specialized surgeons.


Subject(s)
Spinal Neoplasms , Humans , Spinal Neoplasms/surgery , Spinal Neoplasms/pathology , Retrospective Studies , Neoplasm Recurrence, Local , Risk Factors
16.
Sensors (Basel) ; 22(14)2022 Jul 18.
Article in English | MEDLINE | ID: mdl-35891039

ABSTRACT

This paper describes a compact electronic system employing a synchronous demodulation measurement method for the acquisition of pulsed-current signals. The fabricated prototype shows superior performance in terms of signal-to-noise ratio in comparison to conventional instrumentation performing free-running measurements, especially when extremely narrow pulses are concerned. It shows a reading error around 0.1% independently of the signal duty cycle (D) in the investigated D = 10−4−10−3 range. Conversely, high-precision electrometers display reading errors as high as 30% for a D = 10−4, which reduces to less than 1% only for D > 3 × 10−3. Field tests demonstrate that the developed front-end/readout electronics is particularly effective when coupled to dosimeters irradiated with the X-rays sourced by a medical linear accelerator. Therefore, it may surely be exploited for the real-time monitoring of the dosimeter output current, as required in modern radiotherapy techniques employing ultra-narrow pulses of high-energy photons or nuclear particles.


Subject(s)
Electronics , Photons , Radiometry , Signal-To-Noise Ratio , X-Rays
17.
Nanomaterials (Basel) ; 12(13)2022 Jun 30.
Article in English | MEDLINE | ID: mdl-35808088

ABSTRACT

Black diamond is an emerging material for solar applications. The femtosecond laser surface treatment of pristine transparent diamond allows the solar absorptance to be increased to values greater than 90% from semi-transparency conditions. In addition, the defects introduced by fs-laser treatment strongly increase the diamond surface electrical conductivity and a very-low activation energy is observed at room temperature. In this work, the investigation of electronic transport mechanisms of a fs-laser nanotextured diamond surface is reported. The charge transport was studied down to cryogenic temperatures, in the 30−300 K range. The samples show an activation energy of a few tens of meV in the highest temperature interval and for T < 50 K, the activation energy diminishes to a few meV. Moreover, thanks to fast cycles of measurement, we noticed that the black-diamond samples also seem to show a behavior close to ferromagnetic materials, suggesting electron spin influence over the transport properties. The mentioned properties open a new perspective in designing novel diamond-based biosensors and a deep knowledge of the charge-carrier transport in black diamond becomes fundamental.

18.
Materials (Basel) ; 15(4)2022 Feb 13.
Article in English | MEDLINE | ID: mdl-35207919

ABSTRACT

With the aim of presenting the processes governing the Laser-Induced Periodic Surface Structures (LIPSS), its main theoretical models have been reported. More emphasis is given to those suitable for clarifying the experimental structures observed on the surface of wide bandgap semiconductors (WBS) and dielectric materials. The role played by radiation surface electromagnetic waves as well as Surface Plasmon Polaritons in determining both Low and High Spatial Frequency LIPSS is briefly discussed, together with some experimental evidence. Non-conventional techniques for LIPSS formation are concisely introduced to point out the high technical possibility of enhancing the homogeneity of surface structures as well as tuning the electronic properties driven by point defects induced in WBS. Among these, double- or multiple-fs-pulse irradiations are shown to be suitable for providing further insight into the LIPSS process together with fine control on the formed surface structures. Modifications occurring by LIPSS on surfaces of WBS and dielectrics display high potentialities for their cross-cutting technological features and wide applications in which the main surface and electronic properties can be engineered. By these assessments, the employment of such nanostructured materials in innovative devices could be envisaged.

19.
Pathol Res Pract ; 229: 153722, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34952421

ABSTRACT

PURPOSE: We retrospectively analyzed a cohort of patients treated at our Centre with bone marrow concentrated (BMC) injection for aneurysmal bone cyst (ABC) of the spine, in order to propose this treatment as a valid alternative for the management of ABCs. METHODS: Fourteen patients (6 male, 8 female) were treated between June 2014 to December 2019 with BMC injection for ABC of the spine. The mean age was 15.5 years. The mean follow up was 37.4 months (range 12-60 months). The dimension of the cyst and the degree of ossification were measured by Computed Tomography (CT) scans before the treatment and during follow-up visits. RESULTS: Six patients received a single dose of BMC, five patients received two doses and in three patients three doses of BMC were administered. The mean ossification of the cyst (expressed in Hounsfield units) increased statistically from 43.48 ± 2.36 HU to 161.71 ± 23.48 HU during follow-up time and the ossification was associated to an improvement of the clinical outcomes. The mean ossification over time was significantly higher in patients treated with a single injection compared to patients treated with multiple injections. No significant difference in ossification was found between cervical and non-cervical localization of the cyst. Moreover, the initial size of the cyst was not statistically associated with the degree of ossification during follow-up CONCLUSIONS: Results of this paper reinforce our previous evidence on the use of BMC as a valid alternative for spinal ABC management when SAE treatment is contraindicated or ineffective.


Subject(s)
Bone Cysts, Aneurysmal/surgery , Mesenchymal Stem Cell Transplantation , Spinal Diseases/surgery , Adolescent , Adult , Child , Female , Humans , Male , Retrospective Studies , Transplantation, Autologous , Young Adult
20.
Curr Med Imaging ; 18(2): 231-241, 2022.
Article in English | MEDLINE | ID: mdl-34789140

ABSTRACT

Spinal Infection (SI) is an infection of vertebral bodies, intervening disc, and/or adjoining para-spinal tissue. It represents less than 10% of all skeletal infections. There are numerous factors that predispose to developing a SI. Due to the low specificity of signs, delayed diagnosis is common. Hence, SI may be associated with poor outcomes. Diagnosis of SI must be supported by clinicopathological and radiological findings. MRI is a reliable modality of choice. Treatment options vary according to the site of the infection, disease progression, neurology, presence of instability, and general condition of the subject. Conservative treatment (orthosis/ bed-rest + antibiotics) is recommended during the early course with no/ lesser degree of neurological involvement and to medically unfit patients. Nevertheless, when conservative measures alone fail, surgical interventions must be considered. The use of concomitant antimicrobial drugs intravenously during initial duration followed by oral administration is a necessity. Controversies exist regarding the optimal duration of antimicrobial therapy, yet never given less than six weeks. Heterogeneity in clinical picture and associated co-morbidities with a range of treatment modalities are available; however, a common applicable guideline for SI does not exist. Managing SI must be tailored on a case-to-case basis.


Subject(s)
Anti-Bacterial Agents , Magnetic Resonance Imaging , Anti-Bacterial Agents/therapeutic use , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...