Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Immunol Invest ; 51(2): 233-245, 2022 Feb.
Article in English | MEDLINE | ID: mdl-32945214

ABSTRACT

Coronavirus disease (COVID-19) is challenging many health, economic, and social systems. RT-PCR assays are diagnosis gold standard; however, they can lead to false-negative results. Therefore, anti-SARS-CoV-2 IgG, IgM, and IgA investigation can play a complementary role in assessing the individuals immune status. Majority of serological tests focus on IgM and IgG although IgA are the main immunoglobulins involved in mucosal immunity. It has been reported that digestive symptoms may occur in the absence of any typical respiratory symptom. Thus, a complete screening, comprising IgA, IgM, and IgG detection could be more consistent and useful in patients with atypical symptoms or in paucisymptomatic cases. Current literature describes over 200 immunoassays available worldwide, pointing out a great results variability, depending on methodology or antigens' nature. In our study we evaluated anti-SARS-CoV-2 IgA, IgM, and IgG trend on a control group and on two COVID-19 patient groups (early and late infection time) with a lateral-flow combined immunoassay (LFIA) and an enzyme-linked immunosorbent assay (ELISA). Dissimilar antibodies time kinetics have been described in COVID-19 (decreasing IgM concentration with IgA/IgG persistence for a longer time; as well as persistent IgA, IgG, and IgM concentration); our results confirmed both of them depending on the methodology; therefore, it is difficult to compare different studies outcomes, suggesting the importance of a serological tests international standardization. Nevertheless, we propose a flowchart with combined anti-SARS-CoV-2 IgG/IgM/IgA detection as a screening on general population, where serological positivity should be considered as an "alert," to avoid and contain possible new outbreaks.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Humans , Immunoglobulin A , Immunoglobulin G , Immunoglobulin M , Sensitivity and Specificity
2.
Int Immunopharmacol ; 99: 108013, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34339963

ABSTRACT

The antibody response to SARS-CoV-2 has not yet fully defined, but the availability of sensitive and specific serological assays is crucial to observe the presence of specific antibodies against the human receptor binding domain (S-RBD) and high specificity ACE-2-binding antibodies or neutralizing antibodies (NT) in response to vaccines. Indeed, these peculiar antibodies should prevent viral interaction between RBD and Angiotensin-Converting Enzyme 2 (ACE2) receptor, located on surface of host cells. In this study, 72 samples from 37 hospitalized COVID-19 patients and 35 not-hospitalized patients were analyzed longitudinally. The detection of S-RBD and NT antibodies was carried out using CLIA tests. Hospitalized patients showed elevated serum levels of S-RBD (97.22%) and NT (77.78%) antibodies, differently, not-hospitalized, who were paucisymptomatic or asymptomatic patients, showed lower serum levels of S-RBD (65.71%) and NT (38.14%) antibodies. The results suggest that the NT serum level is strongly related to disease severity (p < 0.001) and to the serum level of S-RBD antibodies (p < 0.0001).


Subject(s)
Angiotensin-Converting Enzyme 2/immunology , Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19/immunology , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/blood , Female , Humans , Immunity , Longitudinal Studies , Male , Middle Aged , SARS-CoV-2/immunology , Serologic Tests
3.
Int Immunopharmacol ; 92: 107330, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33412393

ABSTRACT

In addition to molecular testing, there is evolving interest for anti-SARS-CoV-2 antibodies serologic assays. Majority of them focus on IgM/IgG despite IgA important role in mucosal immunity. A simultaneous anti-SARS-CoV-2 IgA/IgG/IgM immunoassay, performed on an automated instrument by ELISA kit coated with native inactivated SARS-CoV-2, was detected on two control groups (negative swab healthcare workers; pre-pandemic healthy or with other viral infections individuals) and on two COVID-19 patient groups (early and late infection). Specificities were 100% in all groups, indicating no cross-reactivity with other infectious or pre-pandemic sera. Sensitivities were 94% in early infection group and 97% in total positive patient group, reaching 100% in late infection group. To our knowledge, this is the first technique based on native SARS-CoV-2. It is able to identify more positive samples than kits using recombinant antigens, therefore virus native epitopes as well as simultaneous anti-SARS-CoV-2 IgA/IgM/IgG detection could help to contain COVID-19 spreading.


Subject(s)
Antibodies, Viral/blood , COVID-19/blood , Immunoglobulin A/blood , Immunoglobulin G/blood , Immunoglobulin M/blood , SARS-CoV-2 , Antibodies, Viral/immunology , Antibody Specificity , COVID-19/immunology , COVID-19/virology , Humans , Immunoassay/methods , SARS-CoV-2/immunology , Sensitivity and Specificity , Serologic Tests/methods