Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 110
Filter
1.
Interv Neuroradiol ; : 15910199241264871, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39091055

ABSTRACT

OBJECTIVE: The Contour Neurovascular System (CNS) is a novel intrasaccular flow disrupting device with a semi-3D cup-like shape for the treatment of intracranial aneurysms. This study investigates the potential and limitations of the CNS for embolization of aneurysm remnants after previous treatment. METHODS: Ten cases of aneurysm recurrence treatment with the CNS were analyzed from a single-center database. Technical success, procedural aspects, complications, and angiographic results were evaluated. RESULTS: The aneurysms (median width: 5.3 mm, median neck width: 3.8 mm) were located in the anterior communicating artery (4), basilar tip (3), internal carotid artery (1), middle cerebral artery (1), and superior cerebellar artery (1). The aneurysms were initially treated endovascularly (9) and by clipping (1). Retreatment failed in one case where the smallest available CNS proved to be too small and had to be removed. Adjunctive coiling was performed in two large remnants of partially thrombosed basilar tip aneurysms. There were no procedural complications or morbidity. At a median follow-up of nine months, 4/8 (50%) aneurysms were completely occluded, 2/8 (25%) had neck remnants, and 2/8 (25%) had aneurysm remnants. The two aneurysm remnants were retreated with coiling and stent-assisted coiling, respectively. CONCLUSIONS: CNS treatment of aneurysm remnants may be feasible, especially for shallow, wide-necked aneurysm geometries. Further studies are needed to identify aneurysm subsets that benefit from CNS retreatment and to define mid- and long-term occlusion rates.

2.
Article in English | MEDLINE | ID: mdl-39122468

ABSTRACT

BACKGROUND AND PURPOSE: The Pipeline Embolization Device is a safe and effective treatment option for intracranial aneurysms. The newer Pipeline generations have received structural refinements and a surface modification to improve deliverability, procedural safety, and angiographic outcomes. This multicenter study evaluated the clinical safety and efficacy of the 2 surface-modified Pipeline iterations, Pipeline Vantage and Pipeline Flex with Shield Technology (PFS). MATERIALS AND METHODS: Consecutive patients treated between 2017 and 2023 were retrospectively reviewed for aneurysm characteristics, procedural details, complications, and angiographic outcomes. The safety end point was the rate of procedural and postprocedural major neurologic events occurring during the hospital stay. The efficacy end point was the rate of complete occlusion at last follow-up. RESULTS: One hundred forty-one patients underwent 112 Pipeline Vantage procedures and 32 PFS procedures for 147 aneurysms with a mean size of 8.0 (SD, 5.9) mm (11% ruptured, 16% posterior circulation, 18% nonsaccular morphology). All procedures were technically successful with a mean of 1.2 devices implanted. Balloon angioplasty was required in 20/144 (13.9%) procedures. Major neurologic adverse events occurred in 6/144 (4.2%) procedures (all ischemic stroke), resulting in death in 2 (1.4%) patients. There were no hemorrhagic complications. At a mean of 11 months, complete occlusion was achieved in 85/112 (75.9%) aneurysms, 15/112 (13.4%) had an entry remnant, and 12/112 (10.7%) had an aneurysm remnant. CONCLUSIONS: The results demonstrate high feasibility, procedural safety, and efficacy of the surface-modified Pipeline flow diverters.

3.
J Neurosurg ; : 1-9, 2024 Aug 16.
Article in English | MEDLINE | ID: mdl-39151207

ABSTRACT

OBJECTIVE: The Contour Neurovascular System (CNS) is a novel intrasaccular flow-disrupting device for the treatment of intracranial aneurysms. This study presents the authors' institutional experience and midterm follow-up results with this device. METHODS: Seventy-six consecutive patients (mean ± SD age 58.9 ± 12.4 years) were treated with the CNS for 76 aneurysms (63 unruptured, 10 recurrent, and 3 ruptured). Aneurysm characteristics, procedural details, and clinical/angiographic outcomes were retrospectively evaluated. RESULTS: The most common aneurysm locations were the basilar tip in 25 (32.9%) cases and the anterior communicating artery in 22 (28.9%). There were 18 (23.7%) sidewall aneurysms. The mean ± SD aneurysm width was 5.6 ± 2.5 mm, and 68 (89.5%) aneurysms were wide-necked. The CNS was successfully implanted in 68 (89.5%) aneurysms, with 11 cases of additional coiling and 1 case each of additional stent and balloon. There were 3 (3.9%) thromboembolic events, of which 1 (1.3%) was symptomatic (a major ischemic stroke) and resulted in morbidity. There were no hemorrhagic events or deaths. At last available follow-up (mean 12 months), 32/56 (57.1%) aneurysms were completely occluded, 16/56 (28.6%) had neck remnants, and 8/56 (14.3%) had an aneurysm remnant. Three (5.4%) aneurysms were retreated. CONCLUSIONS: The use of the CNS was safe and feasible but proper aneurysm selection appears to be required, which may be facilitated with increasing operator experience and further study of this device. Similar to other intrasaccular flow disrupters, midterm complete occlusion rates are moderate but may increase with longer follow-up.

4.
J Cardiovasc Magn Reson ; : 101068, 2024 Jul 28.
Article in English | MEDLINE | ID: mdl-39079602

ABSTRACT

PURPOSE: Diagnosing myocarditis relies on multimodal data including magnetic resonance imaging (MRI), clinical symptoms, and blood values. The correct interpretation and integration of MRI findings requires radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis. METHODS: This retrospective study includes MRI reports from 396 patients with suspected myocarditis and eight centers, respectively. MRI reports and patient data including blood values, age, and further clinical information were provided to GPT-4 and to radiologists with 1 (Resident 1), 2 (Resident 2), and 4 years (Resident 3) of experience in cardiovascular MRI and knowledge of the 2018 Lake Louise Criteria. The final impression of the report regarding the radiological assessment of whether myocarditis is present or not was not provided. The performance of GPT-4 and of the human readers were compared to a consensus reading (two board-certified radiologists with 8 and 10 years of experience in cardiovascular MRI). Sensitivity, specificity, and accuracy were calculated. RESULTS: GPT-4 yielded an accuracy of 83%, sensitivity of 90%, and specificity of 78%, which was comparable to the physician with 1 year of experience (R1: 86%, 90%, 84%, p=.14) and lower than that of more experienced physicians (R2: 89%, 86%, 91%, p=.007 and R3: 91%, 85%, 96%, p<.001). GPT-4 and human readers showed a higher diagnostic performance when results from T1- and T2-mapping sequences were part of the reports, for Residents 1 and Resident 3 with statistical significance (p=.004 and p=.02, respectively). CONCLUSION: GPT-4 yielded good accuracy for diagnosing myocarditis based on MRI reports in a large dataset from multiple centers and therefore holds the potential to serve as a diagnostic decision supporting tool in this capacity, particularly for less experienced physicians. Further studies are required to explore the full potential and elucidate educational aspects of the integration of large language models in medical decision-making.

5.
Interv Neuroradiol ; : 15910199241264340, 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39051598

ABSTRACT

OBJECTIVE: The Pipeline Vantage Embolization Device (PVED) is a novel coated flow diverter with reduced wire diameters to improve neoendothelialization and stent porosity. This systematic review evaluates the safety and efficacy of the PVED based on the current literature. METHODS: Following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines, a thorough literature search was conducted using PubMed, EMBASE, and Cochrane. The random effects model was used to calculate estimates with major neurological complications within 30 days of treatment as the primary safety endpoint and ≤1-year complete occlusion rate as the primary efficacy endpoint. RESULTS: Six single-arm studies (5 retrospective, 1 prospective) with 392 patients and 439 aneurysms (6.8% ruptured) were included. Antiplatelet regimens varied, but dual antiplatelet therapy was administered in the majority. The pooled technical success rate was 99.0% (95%CI, 98.0%-100%) with an average of 1.2 devices implanted per procedure. Balloon angioplasty was performed in 17.0% (95%CI, 6.4-27.6%) and adjunctive coiling in 28.0% (95%CI, 17.8-38.2%), with significant heterogeneity for both variables. Pooled estimates for major neurological complications were 3.5% (95%CI, 1.7%-5.2%) with total ischemic events in 4.1% (95% CI, 1.6%-6.6%) and hemorrhagic events in 1.0% (95% CI, 0.0%-1.9%). The rate of complete angiographic occlusion was 75.7% (95%CI, 70.7%-80.6%) at a mean follow-up of 7 months, with in-stent stenoses in 8.1% (95%CI, 4.5%-11.8%). CONCLUSIONS: The safety and efficacy profile of the PVED appears comparable to competing devices, with potentially fewer complications than first-generation flow diverters. Long-term and comparative studies are needed to further confirm these results.

6.
Clin Neuroradiol ; 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38896270

ABSTRACT

PURPOSE: The WEB 17 system represents the fifth generation of Woven Endobridge (WEB) flow disruptors and features a low profile with fewer wires than its predecessor, the WEB 21. The present study compares the safety and efficacy of the WEB 17 and WEB 21 for the treatment of unruptured cerebral aneurysms with 4-7 mm device sizes, which were available for both systems. METHODS: Patient and aneurysm characteristics, complications, clinical outcome and angiographic results were retrospectively analysed. 1:1 propensity score matching was performed to adjust for minor baseline differences between the groups. RESULTS: Sixty aneurysms treated with WEB 21 and 90 with WEB 17 were included. The overall failure rate (deployment failure and adjunctive stent) was significantly higher with WEB 21 (16.7%) than with WEB 17 (3.3%, p < 0.01). The rates of neurological events between WEB 21 (6.7%) and WEB 17 treatment (1.1%) were not significantly different (p = 0.08). Also, procedural morbidity was comparably low in both groups (WEB 21: 3.3%, WEB 17: 0%, p = 0.16). The rates of complete/adequate occlusion at follow up were 69.7%/86.4% for WEB 17 vs. 80.4%/91.3% for WEB 21 at short-term (p = 0.27), and 64.5%/83.9% vs. 75.9%/86.2% at mid-term (p = 0.41), respectively. Propensity score matching confirmed the results of the unmatched series. CONCLUSION: WEB 17 and WEB 21 had a similar safety and efficacy profile, but WEB 17 was associated with an improved feasibility. Prospective studies with long-term follow-up will define the full potential of the WEB 17 system.

7.
Neurointervention ; 19(2): 92-101, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38880639

ABSTRACT

PURPOSE: Multi-sac aneurysms (MSAs) are not uncommon, but studies on their management are scarce. This study aims to evaluate and compare the feasibility, safety, and efficacy of MSAs treated with either clipping or coiling after interdisciplinary case discussion at our center. MATERIALS AND METHODS: We retrospectively analyzed MSAs treated by microsurgical clipping, coiling, or stent-assisted coiling (SAC). Treatment modalities, complications, angiographic results, and clinical outcomes were evaluated. Major neurological events were defined as a safety endpoint and complete occlusion as an efficacy endpoint. RESULTS: Ninety patients (mean age, 53.2±11.0 years; 73 [81.1%] females) with MSAs met our inclusion criteria (clipping, 50; coiling, 19; SAC, 21). Most aneurysms were located in the middle cerebral artery (48.9%). All clipping procedures were technically successful, but endovascular treatment failed in 1 coiling case, and a switch from coiling to SAC was required in 2 cases. The major event rates were 4.0% after clipping (1 major stroke and 1 intracranial hemorrhage) and 0% after endovascular therapy (P=0.667). At mid-term angiographic follow-up (mean 12.0±8.9 months), all 37 followed clipped aneurysms were completely occluded, compared to 8/17 (41.7%) after coiling and 11/15 (73.3%) after SAC (P<0.001). Coiling was significantly associated with incomplete occlusion in the adjusted analysis (odds ratio, 11.7; 95% confidence interval, 2.7-52.6; P=0.001). CONCLUSION: Both endovascular and surgical treatment were feasible and safe for MSAs. As coiling was associated with comparatively high recanalization rates, endovascular treatment may be preferred with stent support.

9.
Clin Neuroradiol ; 2024 May 30.
Article in English | MEDLINE | ID: mdl-38814452

ABSTRACT

PURPOSE: This study analyzes the long-term clinical and angiographic outcomes of the Derivo Embolization Device (DED), an advanced flow diverter device with an electropolished surface, for the treatment of intracranial aneurysms. METHODS: A consecutive series of 101 patients (mean age: 58 years, 72% female) treated with the DED for 122 aneurysms at a single center between 2017 and 2023 was retrospectively analyzed for major (change in National Institutes of Health Stroke Scale [NIHSS] score ≥ 4 points) and minor (change in NIHSS score < 4 points) neurological events, procedural morbidity (increase of at least one point on the modified Rankin Scale), and angiographic results. RESULTS: There were 14 (11%) recurrent aneurysms, 15 (12%) ruptured aneurysms, 26 (21%) posterior circulation aneurysms and 16 (13%) fusiform or dissecting aneurysms. Device deployment failed in 1 case (1%). Procedure-related symptomatic procedural complications consisted of 2 (2%) major events (1 major stroke and 1 vessel perforation with intracranial hemorrhage and infarction) and 6 minor events (6 minor strokes). Procedural morbidity was 5%. There were no late ischemic or hemorrhagic events during follow-up. Complete and favorable aneurysm occlusion was achieved in 54% (40/74) and 62% (46/74) at a mean of 5 months, 71% (27/38) and 87% (33/38) at a mean of 12 months, and 76% (25/33) and 97% (32/33) at a mean of 35 months, respectively. CONCLUSION: The results demonstrate progressive aneurysm occlusion beyond 12 months after DED implantation with an almost 100% favorable occlusion rate. Procedural morbidity was low and there were no late complications.

10.
Interv Neuroradiol ; : 15910199241248479, 2024 May 05.
Article in English | MEDLINE | ID: mdl-38706147

ABSTRACT

OBJECTIVE: There are few studies on flow diverters with diameters >5 mm. We present our preliminary experience with the 5.5-8 mm Derivo Embolization Device (DED) implants for the treatment of cerebral aneurysms. METHODS: A consecutive series of 26 patients (median age: 60 years) treated for 32 aneurysms in 26 procedures was retrospectively analyzed for procedural characteristics, complications, and mid-term angiographic results. RESULTS: The median aneurysm size was 10.5 mm, 2 of 30 (6%) aneurysms were ruptured and 9 (28%) had a fusiform or dissecting morphology. DED implantation was performed in the internal carotid artery in 18 of 26 (69%) procedures and in the vertebrobasilar artery in 8 (31%). Device deployment failed in 1 (4%) procedure. The 7 and 8 mm implants were successfully deployed in 5 cases. Additional balloon angioplasty or stent implantation was performed in 3 (12%) cases to improve wall apposition. Complications included 1 (4%) major stroke and 2 (8%) minor strokes. Angiographic follow up at a mean of 6 months showed complete occlusion in 8 of30 (27%) aneurysms and favorable occlusion in 14 (47%). CONCLUSIONS: The use of large diameter DEDs was safe and feasible. The mid-term occlusion rates are acceptable considering the complex subset of aneurysms studied. Further studies are warranted to define the indications for large-diameter DEDs and to evaluate their long-term efficacy.

11.
Magn Reson Imaging ; 112: 27-37, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38599503

ABSTRACT

BACKGROUND AND PURPOSE: Long acquisition times limit the feasibility of established non-contrast-enhanced MRA (non-CE-MRA) techniques. The purpose of this study was to evaluate a highly accelerated flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering [REACT]) for imaging of the extracranial arteries in acute ischemic stroke (AIS). MATERIALS AND METHODS: Compressed SENSE (CS) accelerated (factor 7) 3D isotropic REACT (fixed scan time: 01:22 min, reconstructed voxel size 0.625 × 0.625 × 0.75 mm3) and CE-MRA (CS factor 6, scan time: 1:08 min, reconstructed voxel size 0.5 mm3) were acquired in 76 AIS patients (69.4 ± 14.3 years, 33 females) at 3 Tesla. Two radiologists assessed scans for the presence of internal carotid artery (ICA) stenosis and stated their diagnostic confidence using a 5-point scale (5 = excellent). Vessel quality of cervical arteries as well as the impact of artifacts and image noise were scored on 5-point scales (5 = excellent/none). Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery (CCA) and ICA (C1-segment). RESULTS: REACT provided a sensitivity of 88.5% and specificity of 100% for clinically relevant (≥50%) ICA stenosis with substantial concordance to CE-MRA regarding stenosis grading (Cohen's kappa 0.778) and similar diagnostic confidence (REACT: mean 4.5 ± 0.4 vs. CE-MRA: 4.5 ± 0.6; P = 0.674). Presence of artifacts (3.6 ± 0.5 vs. 3.5 ± 0.7; P = 0.985) and vessel quality (all segments: 3.6 ± 0.7 vs. 3.8 ± 0.7; P = 0.004) were comparable between both techniques with REACT showing higher scores at the CCA (4.3 ± 0.6 vs. 3.8 ± 0.9; P < 0.001) and CE-MRA at V2- (3.3 ± 0.5 vs. 3.9 ± 0.8; P < 0.001) and V3-segments (3.3 ± 0.5 vs. 4.0 ± 0.8; P < 0.001). For all vessels, REACT showed a lower impact of image noise (3.8 ± 0.6 vs. 3.6 ± 0.7; P = 0.024) while yielding higher aSNR (52.5 ± 15.1 vs. 37.9 ± 12.5; P < 0.001) and aCNR (49.4 ± 15.0 vs. 34.7 ± 12.3; P < 0.001) for all vessels combined. CONCLUSIONS: In patients with acute ischemic stroke, highly accelerated REACT provides an accurate detection of ICA stenosis with vessel quality and scan time comparable to CE-MRA.


Subject(s)
Ischemic Stroke , Magnetic Resonance Angiography , Humans , Female , Male , Magnetic Resonance Angiography/methods , Aged , Ischemic Stroke/diagnostic imaging , Middle Aged , Neck/diagnostic imaging , Neck/blood supply , Contrast Media , Aged, 80 and over , Signal-To-Noise Ratio , Image Processing, Computer-Assisted/methods , Artifacts , Imaging, Three-Dimensional/methods , Reproducibility of Results , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods
12.
J Am Heart Assoc ; 13(9): e031816, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639365

ABSTRACT

BACKGROUND: Data on impact of COVID-19 vaccination and outcomes of patients with COVID-19 and acute ischemic stroke undergoing mechanical thrombectomy are scarce. Addressing this subject, we report our multicenter experience. METHODS AND RESULTS: This was a retrospective analysis of patients with COVID-19 and known vaccination status treated with mechanical thrombectomy for acute ischemic stroke at 20 tertiary care centers between January 2020 and January 2023. Baseline demographics, angiographic outcome, and clinical outcome evaluated by the modified Rankin Scale score at discharge were noted. A multivariate analysis was conducted to test whether these variables were associated with an unfavorable outcome, defined as modified Rankin Scale score >3. A total of 137 patients with acute ischemic stroke (48 vaccinated and 89 unvaccinated) with acute or subsided COVID-19 infection who underwent mechanical thrombectomy attributable to vessel occlusion were included in the study. Angiographic outcomes between vaccinated and unvaccinated patients were similar (modified Thrombolysis in Cerebral Infarction ≥2b: 85.4% in vaccinated patients versus 86.5% in unvaccinated patients; P=0.859). The rate of functional independence (modified Rankin Scale score, ≤2) was 23.3% in the vaccinated group and 20.9% in the unvaccinated group (P=0.763). The mortality rate was 30% in both groups. In the multivariable analysis, vaccination status was not a significant predictor for an unfavorable outcome (P=0.957). However, acute COVID-19 infection remained significant (odds ratio, 1.197 [95% CI, 1.007-1.417]; P=0.041). CONCLUSIONS: Our study demonstrated no impact of COVID-19 vaccination on angiographic or clinical outcome of COVID-19-positive patients with acute ischemic stroke undergoing mechanical thrombectomy, whereas worsening attributable to COVID-19 was confirmed.


Subject(s)
COVID-19 Vaccines , COVID-19 , Ischemic Stroke , Thrombectomy , Vaccination , Humans , COVID-19/complications , COVID-19/therapy , COVID-19/mortality , Male , Female , Ischemic Stroke/mortality , Ischemic Stroke/surgery , Retrospective Studies , Aged , Middle Aged , Treatment Outcome , COVID-19 Vaccines/adverse effects , SARS-CoV-2 , Aged, 80 and over
13.
J Neurointerv Surg ; 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38569886

ABSTRACT

BACKGROUND: This multicenter study evaluated the safety and efficacy of coated flow diverters (cFDs) for the treatment of ruptured intracranial aneurysms. METHODS: Consecutive patients treated with different cFDs for ruptured aneurysms under tirofiban at eight neurovascular centers between 2016 and 2023 were retrospectively analyzed. The majority of patients were loaded with dual antiplatelet therapy after the treatment. Aneurysm occlusion was determined using the O'Kelly-Marotta (OKM) grading scale. Primary outcome measures were major procedural complications and aneurysmal rebleeding during hospitalization. RESULTS: The study included 60 aneurysms (posterior circulation: 28 (47%)) with a mean size of 5.8±4.7 mm. Aneurysm morphology was saccular in 28 (47%), blister-like in 12 (20%), dissecting in 13 (22%), and fusiform in 7 (12%). Technical success was 100% with a mean of 1.1 cFDs implanted per aneurysm. Adjunctive coiling was performed in 11 (18%) aneurysms. Immediate contrast retention was observed in 45 (75%) aneurysms. There was 1 (2%) major procedural complication (a major stroke, eventually leading to death) and no aneurysmal rebleeding. A good outcome (modified Rankin Scale 0-2) was achieved in 40 (67%) patients. At a mean follow-up of 6 months, 27/34 (79%) aneurysms were completely occluded (OKM D), 3/34 (9%) had an entry remnant (OKM C), and 4/34 (12%) had residual filling (OKM A or B). There was 1 (3%) severe in-stent stenosis during follow-up that was treated with balloon angioplasty. CONCLUSIONS: Treatment of ruptured aneurysms with cFDs was reasonably safe and efficient and thus represents a valid treatment option, especially for complex cases.

14.
J Clin Neurosci ; 124: 94-101, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38678972

ABSTRACT

OBJECTIVE: Overdrainage and frequent reprogramming are common problems with programmable valves after ventriculoperitoneal shunt surgery for idiopathic normal pressure hydrocephalus (iNPH). Non-adjustable, flow-regulated valves offer a potential solution to these problems, but there is limited data on their efficacy. This study will evaluate neurological improvement and overdrainage rates within one year of treatment with a flow-regulated valve. PATIENTS AND METHODS: This prospective study analyzes 45 iNPH patients (median age: 73 years) treated with a flow-regulated valve. Clinical evaluations were performed at baseline, postoperatively, and at 3, 6, and 12 months after surgery. The primary efficacy endpoint was improvement of at least 5 points on the iNPH grading scale at follow-up. The safety endpoint was radiographic evidence of overdrainage. RESULTS: All patients presented with gait disturbance, 35 (78 %) had cognitive impairment, and 35 (78 %) had urinary incontinence. The median duration of symptoms was 24 months. The total iNPH score improved in 33/41 (81 %) at 3 months, in 29/34 (85 %) at 6 months, and in 22/29 (64 %) at 12 months. Overall, 40/45 (89 %) patients had a significant improvement on the iNPH scale. Secondary worsening of symptoms after initial improvement was observed in 5 (11 %) patients. Overdrainage occurred in one patient (2 %) requiring surgical evacuation. CONCLUSION: Treatment of iNPH patients with flow-regulated valves resulted in a good neurological outcome with minimal rates of overdrainage. These results are encouraging and justify the clinical use of these valve types.


Subject(s)
Hydrocephalus, Normal Pressure , Ventriculoperitoneal Shunt , Humans , Hydrocephalus, Normal Pressure/surgery , Aged , Female , Male , Prospective Studies , Aged, 80 and over , Ventriculoperitoneal Shunt/methods , Treatment Outcome , Middle Aged , Follow-Up Studies
15.
Cureus ; 16(3): e56469, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38638787

ABSTRACT

We report the case of an 81-year-old patient with no pre-existing medical conditions who presented with a one-week history of progressive horizontal diplopia. Contrast-enhanced brain magnetic resonance imaging showed a heterogeneous sellar mass with the infiltration of the cavernous sinus and sella. Hormone levels were within normal limits. Considering an endocrine inactive pituitary adenoma, the patient underwent transsphenoidal resection. After surgery, the preoperative symptoms completely resolved. Histopathologic examination of the tumor specimen revealed melanoma. Since the patient had no history of cancer, an extensive staging workup was performed, which revealed multiple lung metastases. However, no primary tumor was found. We recommended adjuvant brain irradiation and chemo- and immunotherapy, but the patient refused further oncological treatment and died five months after surgery. Reported cases of sellar melanoma are rare, and the combination of sellar melanoma and lung metastasis without a cutaneous primary is unique. Although rare, malignant lesions of the sella must be considered in the differential diagnosis, especially in cases with rapid onset of symptoms.

16.
Radiologie (Heidelb) ; 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38607391

ABSTRACT

OBJECTIVE: Mobile head computed tomography (CT) scanners can reduce transport-related complications in neurointensive care unit (NICU) patients and decrease the burden on NICU staff; however, the initial investment cost and reduced image quality of early mobile scanners have prevented their widespread clinical use. Here, we report our initial experience with a novel 32-row mobile CT scanner for use in NICUs. METHODS: Over a 2-year period, 107 patients received a mobile head CT scan. The technical characteristics of the scanner and the organizational procedures are described in detail. Patient characteristics were retrospectively collected and image quality was subjectively evaluated on a Likert scale ranging from 0 to 5 and compared with a stationary CT scanner. RESULTS: Mobile head CT was used for follow-up of intracranial hemorrhage in 51%, routine postoperative imaging in 28%, evaluation of neurological deterioration in 14%, bedside monitoring after external ventricular drain placement in 4%, and follow-up of ischemic stroke in 3% of cases. Diagnostic imaging quality was achieved in all cases, eliminating the need for stationary CT scanning. The overall image quality of mobile CT (median 4 points) was inferior to that of conventional stationary CT (median 5 points, p < 0.01), but was rated with 4 or 5 points in the majority of cases. CONCLUSIONS: State-of-the-art mobile CT was found to be easy to use and maneuver and has the potential to expedite the diagnosis of NICU patients and reduce staff workload. Image quality was adequate for common NICU issues.

17.
Interv Neuroradiol ; : 15910199241246018, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38651292

ABSTRACT

OBJECTIVE: The flow re-direction endoluminal device (FRED) is a safe and effective treatment option for intracranial aneurysms. The novel FRED X features an antithrombotic surface coating ("X Technology") on an otherwise unmodified stent design. This two-center study evaluates the clinical safety and efficacy of FRED X and compares it to the literature. METHODS: Consecutive patients treated between 2020 and 2023 were retrospectively reviewed for aneurysm characteristics, procedural details and complications, and angiographic outcomes. A mini-review of the literature for FRED X clinical trials was performed and results were pooled using a random effects model. RESULTS: Thirty-four patients (mean age 56 years) were treated for 34 aneurysms. The mean aneurysm size was 7.7 ± 5.0 mm, 7 (21%) were ruptured, 6 (18%) were recurrent after previous treatment, 11 (32.3%) were located in the posterior circulation, and 4 (12.5%) had non-saccular morphology. All procedures were technically successful and no balloon angioplasty was required. There was 1 (2.9%) symptomatic complication (a transient ischemic attack) and no procedural morbidity or mortality. Technical asymptomatic events included 1 procedural stent occlusion that was reopened with thrombectomy and 3 cases of vasospasm. Complete and adequate occlusion rates were 68% (19/28) and 89% (25/28) at a mean follow-up time of 6 months, respectively. The results of this study are comparable to previous FRED X studies. CONCLUSIONS: The results demonstrate a high feasibility and procedural safety of the FRED X with adequate mid-term occlusion rates. Long-term and comparative studies are needed to evaluate the full potential of the FRED X.

18.
Sci Rep ; 14(1): 6393, 2024 03 16.
Article in English | MEDLINE | ID: mdl-38493258

ABSTRACT

The use of mobile head CT scanners in the neurointensive care unit (NICU) saves time for patients and NICU staff and can reduce transport-related mishaps, but the reduced image quality of previous mobile scanners has prevented their widespread clinical use. This study compares the image quality of SOMATOM On.Site (Siemens Healthineers, Erlangen, Germany), a state-of-the-art mobile head CT scanner, and a conventional 64-slice stationary CT scanner. The study included 40 patients who underwent head scans with both mobile and stationary scanners. Gray and white matter signal and noise were measured at predefined locations on axial slices, and signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated. Artifacts below the cranial calvaria and in the posterior fossa were also measured. In addition, image quality was subjectively assessed by two radiologists in terms of corticomedullary differentiation, subcalvarial space, skull artifacts, and image noise. Quantitative measurements showed significantly higher image quality of the stationary CT scanner in terms of noise, SNR and CNR of gray and white matter. Artifacts measured in the posterior fossa were higher with the mobile CT scanner, but subcalvarial artifacts were comparable. Subjective image quality was rated similarly by two radiologists for both scanners in all domains except image noise, which was better for stationary CT scans. The image quality of the SOMATOM On.Site for brain scans is inferior to that of the conventional stationary scanner, but appears to be adequate for daily use in a clinical setting based on subjective ratings.


Subject(s)
Tomography, X-Ray Computed , White Matter , Humans , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods , Head/diagnostic imaging , Skull/diagnostic imaging , Radiation Dosage
19.
Sci Rep ; 14(1): 6154, 2024 03 14.
Article in English | MEDLINE | ID: mdl-38486099

ABSTRACT

Intra-arterial nimodipine administration is a widely used rescue therapy for cerebral vasospasm. Although it is known that its effect sets in with delay, there is little evidence in current literature. Our aim was to prove that the maximal vasodilatory effect is underestimated in direct angiographic controls. We reviewed all cases of intra-arterial nimodipine treatment for subarachnoid hemorrhage-related cerebral vasospasm between January 2021 and December 2022. Inclusion criteria were availability of digital subtraction angiography runs before and after nimodipine administration and a delayed run for the most affected vessel at the end of the procedure to decide on further escalation of therapy. We evaluated nimodipine dose, timing of administration and vessel diameters. Delayed runs were performed in 32 cases (19 patients) with a mean delay of 37.6 (± 16.6) min after nimodipine administration and a mean total nimodipine dose of 4.7 (± 1.2) mg. Vessel dilation was more pronounced in delayed vs. immediate controls, with greater changes in spastic vessel segments (n = 31: 113.5 (± 78.5%) vs. 32.2% (± 27.9%), p < 0.0001) vs. non-spastic vessel segments (n = 32: 23.1% (± 13.5%) vs. 13.3% (± 10.7%), p < 0.0001). In conclusion intra-arterially administered nimodipine seems to exert a delayed vasodilatory effect, which should be considered before escalation of therapy.


Subject(s)
Subarachnoid Hemorrhage , Vasospasm, Intracranial , Humans , Nimodipine/pharmacology , Vasodilator Agents/therapeutic use , Vasospasm, Intracranial/diagnostic imaging , Vasospasm, Intracranial/drug therapy , Subarachnoid Hemorrhage/diagnostic imaging , Subarachnoid Hemorrhage/drug therapy , Angiography, Digital Subtraction
20.
Cureus ; 16(1): e52474, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38371129

ABSTRACT

INTRODUCTION: Seizures are a common symptom of supratentorial meningiomas with pre- and postoperative seizure rates of approximately 30% and 12%, respectively, especially in parasagittal and convexity meningiomas. Less is known about the association between seizures and posterior fossa meningiomas. This study evaluates the prevalence, potential causes, and outcomes of seizures in patients who have undergone surgery for posterior fossa meningioma. METHODS: This is a retrospective, observational, single-center study of consecutive patients who underwent surgical resection of posterior fossa meningiomas between 2009 and 2017. We retrospectively identified patients with seizures and analyzed patient demographics, tumor characteristics, and procedural characteristics. RESULTS: A total of 44 patients (mean age: 59.8 ± 13.5 years) were included. Twenty-six tumors were located at the cerebellar convexity and tentorium (59.1%), 12 at the cerebellopontine angle (27.3%), four at the clivus (9.1%), and two at the foramen magnum (4.5%). Seizures were the presenting symptom of cerebellar meningioma in two patients. Patients were seizure-free after surgery. Three patients had their first seizure after surgery (interval between surgery and first seizure: two days to 17 months). Analysis of these three patients revealed possible causes of postoperative seizures: radiation necrosis and edema, hyponatremia, and preoperative hydrocephalus. In all patients with postoperative seizures, long-term seizure control was achieved with the administration of antiepileptic drugs. CONCLUSIONS: The incidence of seizures in patients with posterior fossa meningiomas is relatively low. Antiepileptic drugs can help to achieve seizure control.

SELECTION OF CITATIONS
SEARCH DETAIL