Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 94(3): 033512, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-37012776

ABSTRACT

Filamentary structures, also known as blobs, are a prominent feature of turbulence and transport at the edge of magnetically confined plasmas. They cause cross-field particle and energy transport and are, therefore, of interest in tokamak physics and, more generally, nuclear fusion research. Several experimental techniques have been developed to study their properties. Among these, measurements are routinely performed with stationary probes, passive imaging, and, in more recent years, Gas Puff Imaging (GPI). In this work, we present different analysis techniques developed and used on 2D data from the suite of GPI diagnostics in the Tokamak à Configuration Variable, featuring different temporal and spatial resolutions. Although specifically developed to be used on GPI data, these techniques can be employed to analyze 2D turbulence data presenting intermittent, coherent structures. We focus on size, velocity, and appearance frequency evaluation with, among other methods, conditional averaging sampling, individual structure tracking, and a recently developed machine learning algorithm. We describe in detail the implementation of these techniques, compare them against each other, and comment on the scenarios to which these techniques are best applied and on the requirements that the data must fulfill in order to yield meaningful results.

2.
Rev Sci Instrum ; 93(12): 123504, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36586925

ABSTRACT

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

3.
Rev Sci Instrum ; 92(10): 103502, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34717421

ABSTRACT

For the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I-V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I-V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field (f̃ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

4.
Rev Sci Instrum ; 92(3): 033522, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33820112

ABSTRACT

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

5.
Rev Sci Instrum ; 90(8): 083504, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31472602

ABSTRACT

High bandwidth, high spatial resolution measurements of electron temperature, density, and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements, either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimized for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customizable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g., real-time control outputs and more voltage states) and scalability through collaboration.

6.
Phys Rev Lett ; 112(11): 115001, 2014 Mar 21.
Article in English | MEDLINE | ID: mdl-24702380

ABSTRACT

With fusion device performance hinging on the edge pedestal pressure, it is imperative to experimentally understand the physical mechanism dictating the pedestal characteristics and to validate and improve pedestal predictive models. This Letter reports direct evidence of density and magnetic fluctuations showing the stiff onset of an edge instability leading to the saturation of the pedestal on the Alcator C-Mod tokamak. Edge stability analyses indicate that the pedestal is unstable to both ballooning mode and kinetic ballooning mode in agreement with observations.

SELECTION OF CITATIONS
SEARCH DETAIL