Braz Dent J ; 34(1): 39-44, 2023.
Article in English | MEDLINE | ID: mdl-36888843

ABSTRACT

The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Subject(s)
Radiography, Dental, Digital , Radiography, Dental, Digital/methods , Reproducibility of Results
2.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1420574

ABSTRACT

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

3.
Braz Oral Res ; 36: e130, 2022.
Article in English | MEDLINE | ID: mdl-36383836

ABSTRACT

This study aimed to assess the microstructure, chemical composition, and image quality of different photostimulable phosphor plates (PSP). Four PSP systems, Express®, Digora®, VistaScan®, and Apixia,® were assessed. Five radiographs of a homogeneous acrylic phantom were obtained with the PSP of each system, to acquire a total of 20 images. The images were objectively evaluated for uniformity using mean grey and standard deviation (SD) of their grey values. PSP receptors were analyzed using scanning electron microscopy (SEM) to determine the thickness of the granule layer and the size of the granules. The chemical composition of the PSP receptors was analyzed using total reflection X-ray fluorescence (TXRF). VistaScan showed more uniform and higher density images than the other tested systems (p < 0.05), as well as the lowest SD of grey values (p < 0.05). Regarding the microstructure of the receptors, Digora and VistaScan had thicker granule layers than Express and Apixia, and VistaScan had smaller granules than Digora and Express (p < 0.05). Fourteen chemical elements were detected in the receptors, with barium being the element with the highest concentration in all PSP systems. The microstructure, chemical composition, and image quality varied among all four PSP receptors studied. VistaScan receptors showed the smallest variation in granule size, one of the thickest granule layers, and the most uniform and least noisy images.


Subject(s)
Radiographic Image Enhancement , Radiography, Dental, Digital , Radiography, Dental, Digital/methods , Phantoms, Imaging , Radiographic Image Enhancement/methods
4.
Braz. oral res. (Online) ; 36: e130, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1403968

ABSTRACT

Abstract This study aimed to assess the microstructure, chemical composition, and image quality of different photostimulable phosphor plates (PSP). Four PSP systems, Express®, Digora®, VistaScan®, and Apixia,® were assessed. Five radiographs of a homogeneous acrylic phantom were obtained with the PSP of each system, to acquire a total of 20 images. The images were objectively evaluated for uniformity using mean grey and standard deviation (SD) of their grey values. PSP receptors were analyzed using scanning electron microscopy (SEM) to determine the thickness of the granule layer and the size of the granules. The chemical composition of the PSP receptors was analyzed using total reflection X-ray fluorescence (TXRF). VistaScan showed more uniform and higher density images than the other tested systems (p < 0.05), as well as the lowest SD of grey values (p < 0.05). Regarding the microstructure of the receptors, Digora and VistaScan had thicker granule layers than Express and Apixia, and VistaScan had smaller granules than Digora and Express (p < 0.05). Fourteen chemical elements were detected in the receptors, with barium being the element with the highest concentration in all PSP systems. The microstructure, chemical composition, and image quality varied among all four PSP receptors studied. VistaScan receptors showed the smallest variation in granule size, one of the thickest granule layers, and the most uniform and least noisy images.

6.
BMC Oral Health ; 21(1): 356, 2021 07 20.
Article in English | MEDLINE | ID: mdl-34284755

ABSTRACT

BACKGROUND: As the hard palate is a central structure of the skull, and its close relationship with the nasal cavity, oral cavity, and maxillary sinuses, it would be of interest to study if there is a relationship between this bone and other structures of the stomatognathic system. Thus, this study aimed to assess the dimensions of the hard palate and associate them with sex, and skeletal and breathing patterns. Also, to investigate if there is a relationship between these dimensions and the volumes of the upper airways and maxillary sinuses. METHODS: Two hundred and ninety-eight CBCT scans of patients were classified according to sex, and skeletal and breathing patterns. Then, the linear dimensions of width and height of the hard palate at the regions of the first premolars and first molars, and the volumes of the upper airways and maxillary sinuses were measured using the CS 3D Imaging and ITK-SNAP software, respectively. Data were submitted to multi-way analysis of variance and linear regression, with a significance level of 5% (α = 0.05). RESULTS: Sex and facial type influenced the hard palate dimensions (p < 0.05). Males had greater width and height of the hard palate than females (p < 0.0001). It was observed greater width for brachycephalics at the first premolars region (p = 0.0032), and greater height for dolichocephalics at the first premolars (p = 0.0154) and first molars (p = 0.0038) regions. Skeletal malocclusion and breathing pattern did not influence the measurements of the hard palate (p > 0.05). There was a significant relationship between the width and height of the hard palate at the premolar's region and the total volume of the upper airways (p = 0.018, and p = 0.038), and between both dimensions of the hard palate at the molar's region and the total volume of the maxillary sinuses (p < 0.0001). CONCLUSIONS: The hard palate dimensions are influenced by sex and facial type, but not by skeletal malocclusion or breathing pattern. Also, there is an association between these dimensions and the volumes of the upper airways and maxillary sinuses.


Subject(s)
Palate, Hard , Spiral Cone-Beam Computed Tomography , Cone-Beam Computed Tomography , Female , Humans , Male , Maxillary Sinus/diagnostic imaging , Palate, Hard/diagnostic imaging , Skull
7.
Int J Oral Maxillofac Implants ; 36(2): 307-312, 2021.
Article in English | MEDLINE | ID: mdl-33909720

ABSTRACT

PURPOSE: To evaluate the influence of low-dose protocols, with different numbers of basis images, on the precision of linear bone measurements in CBCT images. MATERIALS AND METHODS: Five polyurethane mandibles, with different levels of bone resorption, were used in this in vitro study. To obtain the reference standard, landmarks were made in the mandibular superior and buccal cortices, and then a digital caliper was used to measure the bone height and thickness at these regions. CBCT images were obtained with the PaX-i3D (Vatech) unit set at 50 kV, 4 mA, 0.2-mm voxel size and 50 × 50-mm field of view. Keeping these parameters fixed, each mandible was scanned twice, with different protocols: Low dose (L) had an acquisition time of 24 seconds and 720 basis images, and ultralow dose (UL) had an acquisition time of 15 seconds and 450 basis images. Then, measurements of bone height and thickness were performed on the images, using the previously determined landmarks as reference. The obtained data were submitted to statistical analysis, with a significance level of .05. Analysis of variance, Student t test, and intraclass correlation coefficient were employed. RESULTS: Regarding bone height, there were no significant differences between the measurements obtained with the L and UL protocols (P = .8648). Additionally, the L and UL protocols did not differ in relation to the reference standard (P = .8717 and P = .9928, respectively). Likewise, there were no significant differences between the measurements obtained with the L and UL protocols (P = .7969) for bone thickness, nor between these protocols and the gold standard (P = .7455). CONCLUSION: Considering the great demand for precise measurements in implantology, protocols of low-dose radiation can be used without compromising clinical planning.


Subject(s)
Dental Implants , Spiral Cone-Beam Computed Tomography , Cone-Beam Computed Tomography , Humans , Mandible/diagnostic imaging , Reproducibility of Results
8.
Braz Oral Res ; 35: e036, 2021.
Article in English | MEDLINE | ID: mdl-33909858

ABSTRACT

Evaluating factors that may influence the nose dimensions and, therefore, contribute to the singularity of a person, is important for obtaining a precise facial reconstruction (FR) in forensic anthropology. Thus, the aim in this study was to evaluate the influence of sex, skeletal class, and facial type on nose dimensions of Brazilian individuals using cone-beam computed tomography (CBCT) scans. CBCT images of 54 males and 67 females were classified according to skeletal class (class I, II, or III) and facial type (brachycephalic, dolichocephalic and mesocephalic). Linear and angular measurements of the nose were performed using the CS 3D Imaging software. The measurements obtained for males and females were compared by one-way ANOVA. Two-way ANOVA was used to compare the measurements in the different skeletal classes and facial types. Significance level was set at 5%. All linear measurements were greater in males (p < 0.05); the angular measurements, however, did not differ between sexes (p > 0.05). Linear and angular measurements of class III males were significantly different from the other classes; the same was observed for the angular measurements in females (p < 0.05). Regarding facial types, some linear measurements were significantly greater in dolichocephalics males (p < 0.05). For females, there was no influence of facial type (p > 0.05), except for the nasal convexity angle. Nose dimensions differed in specific points among different skeletal classes and facial types, and there was sexual dimorphism in all linear nose dimensions. This information may be applicable for nose reconstructions, allowing more reliable FR.


Subject(s)
Spiral Cone-Beam Computed Tomography , Brazil , Cone-Beam Computed Tomography , Face/diagnostic imaging , Female , Humans , Imaging, Three-Dimensional , Male , Nose/diagnostic imaging
9.
Gen Dent ; 69(1): 38-43, 2021.
Article in English | MEDLINE | ID: mdl-33350954

ABSTRACT

This study evaluated the influence of chewing-side preference on the volume of the mandibular condyle and coronoid process and the dynamic parameters of the temporomandibular joint (TMJ). Cone beam computed tomographic scans of both TMJs of 90 individuals with a chewing-side preference were obtained while the patients were in the closed-mouth and maximum mouth-opening positions (test power ≥ 0.80). The preferred chewing side was identified with a chewing gum test as well as by patient self-reports of preferred side and hemispheric dominance (ie, dominant side of the body). Two trained examiners assessed the volume of the mandibular condyle and coronoid process and the dynamic parameters of the TMJs on both sides. The volumes of the mandibular condyle on the 2 sides were compared using a paired t test (α = 0.05). McNemar and Bowker tests of symmetry (α = 0.05) were used for concordance analyses of the dynamic parameters of the TMJ on the chewing and nonchewing sides. No statistically significant difference was observed in the volume of the mandibular condyle (chewing gum test, P = 0.4548; interview, P = 0.7191; hemispheric dominance, P = 0.3471) or coronoid process (chewing gum test, P = 0.7718; interview, P = 0.8072; hemispheric dominance, P = 0.8301) on the chewing and nonchewing sides, regardless of the method used to identify chewing preference. The preferred chewing side also did not significantly affect the dynamic parameters of the mandibular condyle (P = 0.5538). Chewing-side preference does not influence the volume of the mandibular condyle or coronoid process or the dynamic parameters of the TMJ.


Subject(s)
Spiral Cone-Beam Computed Tomography , Temporomandibular Joint Disorders , Cone-Beam Computed Tomography , Humans , Mandibular Condyle/diagnostic imaging , Temporomandibular Joint/diagnostic imaging , Temporomandibular Joint Disorders/diagnostic imaging
10.
J Oral Maxillofac Surg ; 79(3): 695.e1-695.e13, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33358709

ABSTRACT

PURPOSE: As the hard palate is a central structure of the skull and is involved in orthodontic and surgical procedures, it would be of interest to study the morphological aspects of this bone and its possible variations as per different patterns of skeletal development. Thus, this study aimed to develop a classification for the different morphological characteristics of the hard palate and to evaluate the relationship between these characteristics and the different skeletal patterns, using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: This retrospective and cross-sectional study used CBCT scans of patients seen from January 2014 to December 2016. Carestream Dental 3D Imaging software was applied to classify each patient according to vertical and sagittal skeletal patterns, and to evaluate the 3 morphological characteristics of the hard palate: depth (flat, regular, or deep), inclination (superior, parallel, or inferior), and presence of a bony projection (S-shaped). χ2 and Fisher's exact tests evaluated the relationship between the hard palate characteristics and the different skeletal patterns. RESULTS: A total of 298 CBCT scans (144 males and 154 females) were evaluated. The depth of the hard palate was significantly related to both skeletal patterns in males (P < .05), with Class II and dolichocephalics presenting a greater amount of deep palates, while classes I and III and brachycephalics had a greater amount of regular palates. The inclination of the hard palate was significantly associated with the facial type in females (P < .05), with brachycephalics and mesocephalics presenting a greater amount of parallel palates, whereas dolichocephalics had a greater number of inferiorly inclined palates. Regarding the presence of the S-shape in the hard palate, there was a greater number of this projection in Class II males and brachycephalic females. CONCLUSIONS: A morphological classification for the hard palate was developed. The morphology of the hard palate varied among the different skeletal patterns.


Subject(s)
Cone-Beam Computed Tomography , Palate, Hard , Cross-Sectional Studies , Female , Humans , Male , Palate , Palate, Hard/diagnostic imaging , Retrospective Studies , Skull
11.
Braz Dent J ; 31(5): 505-510, 2020.
Article in English | MEDLINE | ID: mdl-33146334

ABSTRACT

The present study used microcomputed tomography (micro-CT) images to assess the prevalence, number, and location of apical ramifications (ARs) in the root canals of different dental groups in a Brazilian population. Three hundred and sixty-seven extracted human teeth, totaling 475 roots, were scanned by micro-CT at 19.6 µm spatial resolution. The obtained images were evaluated by two observers in consensus, and a descriptive analysis was performed to verify the prevalence, number, and location of ARs in each dental group. Chi-square test was used to compare the prevalence of ARs in different types of roots, and one-way analysis of variance compared the number of ARs in the apical 1 mm, 2 mm, and 3 mm of the root. Significance level was established at 5% (α=0.05). ARs were present in 253 (53.3%) of the 475 roots evaluated. A total of 607 ARs were detected, with the vast majority (530) located at one and two millimeters from the main foramen. The highest prevalence of ARs was observed in maxillary canines (65%); maxillary premolars - single-rooted (83.3%), buccal root (80%), and palatine root (73.3%); mandibular premolars (64.2%); mesiobuccal root of maxillary molars (76.6%); and mesial root of mandibular molars (66.6%). For the Brazilian population, most of the ARs are located in the apical 1 and 2 mm of the root, with greater prevalence in the posterior teeth and maxillary canines. These findings suggest the need for additional attention while planning endodontic treatments, including strategies to effectively clean and fill the apical region.


Subject(s)
Dental Pulp Cavity , Tooth Root , Brazil , Dental Pulp Cavity/diagnostic imaging , Humans , Molar , X-Ray Microtomography
13.
Clin Oral Investig ; 24(9): 3299-3305, 2020 Sep.
Article in English | MEDLINE | ID: mdl-31965283

ABSTRACT

OBJECTIVES: To assess C-shaped root canal configuration by identifying its prevalence and each configuration type proportion, according to tooth (mandibular first or second molar) and demographic characteristics in a Brazilian population, using cone-beam computed tomography (CBCT). Moreover, it was verified if there is a relationship between root canal configuration observed in two-dimensional reconstructions of CBCT and presence of C-shape. METHODS: Mandibular jaw CBCT scans (184 males and 220 females, aged 15 to 80 years), which presented 1464 mandibular molars (710 first molars and 754 second molars), were assessed. Teeth were evaluated for the presence and type of C-shaped root canals by observing the roots at five levels in CBCT axial reconstructions. Root canal configuration was assessed in panoramic reconstructions. Data were statistically analyzed at a significance level of 5%. RESULTS: Of the 1464 mandibular molars, 125 (8.5%) were classified as C-shaped. This variation was more prevalent in females (n = 107, 85.6%) and in second molars (n = 108, 86.4%). C1 (uninterrupted C-shaped canal) was the most prevalent type of C-shaped configuration (41.76%), while C5 (no canal lumen) was the least prevalent type (0.96%). Single root with single canal in panoramic reconstructions was the most predominant configuration for C-shaped teeth (n = 54, 43.2%). Fused roots presented 17.2 higher odds of being associated with C-shaped root canals than non-fused roots. CONCLUSIONS: C-shaped root canals were more prevalent in mandibular second molars and in females. Additionally, clinicians should bear in mind the greater possibility of C-shaped configuration in mandibular molars with fused roots. CLINICAL RELEVANCE: Mandibular molars with C-shaped canals present a clinical challenge. A higher C-shaped proportion was noted in radiographic fused root types, which had 17.2 higher odds of presenting such anatomy when compared to radiographic non-fused roots. Root radiographic features may help in diagnosis of complex C-shaped morphologies.


Subject(s)
Cone-Beam Computed Tomography , Dental Pulp Cavity , Tooth Root , Brazil , Dental Pulp Cavity/diagnostic imaging , Female , Humans , Male , Mandible/diagnostic imaging , Molar/diagnostic imaging , Prevalence , Tooth Root/diagnostic imaging
14.
Oral Radiol ; 36(2): 183-189, 2020 04.
Article in English | MEDLINE | ID: mdl-31267257

ABSTRACT

OBJECTIVES: To evaluate the accuracy of ITK-SNAP software for measuring volumes of a non-regular shape structure, using cone beam computed tomography (CBCT) scans, besides for developing a mathematical model to correct the software measurement error in case it existed. METHODS: A phantom made by moulding a rubber duck's head was filled with total (38,000 mm3) and partial volumes of water (7000 mm3, 14,000 mm3, 21,000 mm3, 28,000 mm3 and 35,000 mm3), which constituted the gold standards. The sound phantom and the phantom filled with different volumes of water were scanned in a Picasso Trio CBCT unit set at 80 kVp, 3.7 mA, 0.2 mm3 voxel and 12 × 8.5 cm field of view. Semi-automatic segmentation was performed with ITK-SNAP 3.0 software by two trained oral radiologists. Linear regression analyzed the relation between ITK-SNAP calculated volumes and the gold standard. Intraclass correlation coefficient was applied to analyze the reproducibility of the method. Significance level was set at 5%. RESULTS: Linear regression analysis showed a significant relationship between ITK-SNAP volumes and the gold standard (F = 22,537.3, p < 0.0001), with an R2 of 0.9993. The average error found was 4.7 (± 4.3) %. To minimize this error, a mathematical model was developed and provided a reduction of it. ICC revealed excellent intra-examiner agreements for both examiners 1 (ICC = 0.9991, p < 0.0001) and 2 (ICC = 0.9989, p < 0.0001). Likewise, inter-examiner agreement was excellent (ICC = 0.9991, p < 0.0001). CONCLUSION: The software showed to be accurate for evaluating non-regular shape structures. The mathematical model developed reduced an already small error on the software's measurements.


Subject(s)
Cone-Beam Computed Tomography , Imaging, Three-Dimensional , Phantoms, Imaging , Reproducibility of Results , Software
15.
Spec Care Dentist ; 40(1): 84-89, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31799710

ABSTRACT

AIMS: To assess the prevalence of degenerative bone changes in the temporomandibular joint (TMJ) of older adults using cone-beam computed tomography (CBCT), and to verify possible associations between these findings and patient health history. METHODS: CBCT scans comprising both TMJs were acquired for 137 patients aged 65+, regardless of TMD status. Images were assessed by two oral radiologists and evaluated for the presence of flattening, erosion, sclerosis, subchondral cysts, and osteophytes in the TMJ bony components, and self-reported patient systemic health histories were retrieved from records. RESULTS: There were 59 males, and the mean age was 73.35 ± 6.28. A total of 31.4% had bone changes in both TMJs, and 65.7% had bone changes in at least one side. Bone changes were more prevalent in females, with subchondral cysts (63.3%) and osteophytes (60%) the most common findings. There was a higher prevalence of osteoporosis/osteopenia (38.5%) and connective tissue disorders (39.8%) in patients with TMJ bone changes than in those with normal TMJs. CONCLUSION: Degenerative bone changes of TMJ were prevalent among older adults, and females were more affected. There was a greater prevalence of osteoporosis/osteopenia and connective tissue disorders in patients with TMJ bone changes than in subjects with normal TMJs.


Subject(s)
Osteoarthritis , Osteophyte , Temporomandibular Joint Disorders , Aged , Cone-Beam Computed Tomography , Female , Humans , Male , Temporomandibular Joint
16.
Eur Endod J ; 4(3): 133-138, 2019.
Article in English | MEDLINE | ID: mdl-32161900

ABSTRACT

OBJECTIVE: To assess the detection of simulated periapical lesions in digital intraoral radiography with different levels of brightness and contrast combinations, and to investigate the observers' preference of image quality for this diagnostic task. METHODS: Digital radiographs were acquired prior to periapical lesion simulation and after each one of four defects enlargement. Original images were adjusted in 4 brightness and contrast combinations. Five observers evaluated the images according to the presence of periapical lesion on a 5-point scale. In a second moment, the observers ordinated the images subjectively, according to quality, from the best to the worst to detect the bone defect. The area under the receiver operating characteristic curve was calculated for the diagnostic values and compared by two-way ANOVA. The significance level was set at 5% (P<0.05). RESULTS: No differences were found between the diagnostic values of the five combinations of brightness and contrast (P>0.05). The overall results showed low values of area under the Receiver Operating Characteristic (ROC) curve and sensitivity of the periapical radiography in the detection of periapical lesions of sizes from 1 to 3, which rose substantially in size 4. For image quality, combinations with the lowest brightness and highest contrast were preferred by the observers in 58% of the cases. CONCLUSION: Brightness and contrast adjustments do not influence the detection of simulated periapical lesions in digital intraoral radiography. Lower brightness and higher contrast images were preferred for this diagnostic task.

17.
Dent Traumatol ; 32(3): 180-4, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26542421

ABSTRACT

AIM: Line pairs are the unit for measurement of resolution and are related to the spatial quality of the system. Thus, the objective of this study was to evaluate the influence of number of line pairs in digital intra-oral radiography on the detection accuracy of horizontal root fractures. MATERIALS AND METHODS: Sixty-four extracted single-root human teeth were used. Thirty-two had horizontal root fractures created and were mounted in dry human mandibles. The teeth were radiographed with two digital receptors: the Digora Optime (14.3 lp mm-1) and the Digora Toto (26.3 lp mm-1). Images were viewed under standardized conditions by 3 calibrated examiners using the respective dedicated software (Digora for Windows 2.6(®) and Scanora(®) ). Digora Toto(®) images were also evaluated through the Digora for Windows 2.6(®) software. The results were statistically analyzed based on the area under the ROC curve for each examiner. RESULTS: Pairing Digora Toto(®) with Scanora(®) allowed for greater accuracy in horizontal root fractures diagnosis, while images acquired with that same system seem to lose accuracy when visualized with Digora for Windows 2.6(®) . Pairing Digora Optime(®) with Digora for Windows 2.6(®) resulted in the lowest accuracy for horizontal root fractures diagnosis. CONCLUSIONS: The higher number of line pairs and the consequent higher image resolution provided by the Digora Toto(®) system and its dedicated software seem to enhance the accuracy of horizontal root fractures diagnostic imaging.


Subject(s)
Radiography, Dental, Digital , Tooth Fractures/diagnostic imaging , Tooth Root/injuries , Humans , Reproducibility of Results , Sensitivity and Specificity
18.
J Oral Maxillofac Surg ; 73(7): 1395.e1-5, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25976692

ABSTRACT

PURPOSE: To determine the height and volume of the mandibular coronoid process (CP) by cone-beam computed tomography (CBCT) and to identify the presence of any correlations of these measurements with age, gender, facial type, and skeletal class. MATERIALS AND METHODS: The sample consisted of 132 patients from a departmental routine patient base. After CBCT, CP height was determined using OnDemand 3D software (CyberMed, Seoul, Republic of Korea), and CP volume was obtained using ITK-SNAP 3.0 software (Cognitica, Philadelphia, PA). Measurements were subjected to analysis of covariance against facial type, skeletal class, gender, and age, with a significance level of 5%. RESULTS: CP height and volume were similar regardless of age, facial type, and skeletal class. However, the 2 measurements were statistically different regarding gender, with larger values for men than for women. CONCLUSIONS: These observations suggest that gender is the only factor influencing the height and volume of the CP.


Subject(s)
Cephalometry/methods , Cone-Beam Computed Tomography/methods , Face/diagnostic imaging , Malocclusion/diagnostic imaging , Mandible/diagnostic imaging , Adult , Age Factors , Aged , Aged, 80 and over , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Malocclusion, Angle Class I/diagnostic imaging , Malocclusion, Angle Class II/diagnostic imaging , Malocclusion, Angle Class III/diagnostic imaging , Maxilla/diagnostic imaging , Middle Aged , Nasal Bone/diagnostic imaging , Prospective Studies , Sella Turcica/diagnostic imaging , Sex Factors , Young Adult
SELECTION OF CITATIONS