1.
Anesth Analg ; 134(1): 141-148, 2022 01 01.
Article in English | MEDLINE | ID: mdl-33929346

ABSTRACT

BACKGROUND: The respiratory volume monitor (RVM) (ExSpiron, Respiratory Motion Inc, Watertown, MA) uses thoracic impedance technology to noninvasively and continuously measure tidal volume (TV), respiratory rate (RR), and minute ventilation (MV). We aimed to validate the accuracy of the RVM to assess ventilation in neonates and infants by comparing it to spirometry. METHODS: We used the RVM and Respironics NM3 spirometer (Respironics NM3 Respiratory Profile Monitor, Philips Healthcare, Amsterdam, the Netherlands) to record simultaneous and continuous measurements of MV, TV, and RR. The RVM measurements, with and without external calibration, were compared to the Respironics NM3 spirometer using Bland-Altman analysis. The relative errors (Bland-Altman) between RVM and Respironics NM3 were calculated and used to compute individual patient bias, precision, and accuracy as the mean error, the standard deviation (SD) of the error, and the root mean square error. Bland-Altman limits of agreement (LoA) were computed, and equivalence tests were performed. RESULTS: Forty patients were studied to compare the RVM and Respironics NM3 measurements. The mean difference (ie, bias) for MV was 1.8% with 95% LoA, defined as mean ± 1.96 SD, in the range of -12.1% to 15.7%. Similarly, the mean difference (ie, bias) for TV and RR was 1.2% (95% LoA, -11.0% to 13.5%) and 0.6% (95% LoA, -3.7% to 5.0%), respectively. The mean measurement precision of the RVM relative to the Respironics NM3 for MV, TV, and RR was 10.8%, 8.9%, and 8.4%, respectively. The mean measurement accuracy for MV, TV, and RR across patients was 11.0%, 9.7%, and 7.1%, respectively. CONCLUSIONS: The data demonstrate that the RVM measures TV and MV in this cohort with an average relative error of 11% when using patient calibration and 16.9% without patient calibration. The average relative error of RR was 7.1%. The RVM provides accurate measurement of RR, TV, and MV in mechanically ventilated neonates and infants.


Subject(s)
Monitoring, Intraoperative/instrumentation , Monitoring, Physiologic/instrumentation , Respiration, Artificial/methods , Calibration , Cohort Studies , Female , Humans , Infant , Infant, Newborn , Intensive Care Units , Lung Volume Measurements , Male , Monitoring, Intraoperative/methods , Monitoring, Physiologic/methods , Pilot Projects , Prospective Studies , Reproducibility of Results , Respiration , Respiratory Rate , Spirometry/methods , Tidal Volume , Ventilators, Mechanical
4.
Anesth Analg ; 125(6): 1913-1919, 2017 12.
Article in English | MEDLINE | ID: mdl-28759491

ABSTRACT

BACKGROUND: Pediatric patients following surgery are at risk for respiratory compromise such as hypoventilation and hypoxemia depending on their age, comorbidities, and type of surgery. Quantitative measurement of ventilation in nonintubated infants/children is a difficult and inexact undertaking. Current respiratory assessment in nonintubated patients relies on oximetry data, respiratory rate (RR) monitors, and subjective clinical assessment, but there is no objective measure of respiratory parameters that could be utilized to predict early respiratory compromise. New advances in technology and digital signal processing have led to the development of an impedance-based respiratory volume monitor (RVM, ExSpiron, Respiratory Motion, Inc, Waltham, MA). The RVM has been shown to provide accurate real-time, continuous, noninvasive measurements of tidal volume (TV), minute ventilation (MV), and RR in adult patients.In this prospective observational study, our primary aim was to determine whether the RVM accurately measures TV, RR, and MV in pediatric patients. METHODS: A total of 72 pediatric patients (27 females, 45 males), ASA I to III, undergoing general anesthesia with endotracheal intubation were enrolled. After endotracheal intubation, continuous data of MV, TV, and RR were recorded from the RVM and an in-line monitoring spirometer (NM3 monitor, Phillips Healthcare). RVM and NM3 measurements of MV, TV, and RR were compared during a 10-minute period prior to the incision ("Presurgery") and a 10-minute period after the end of surgery ("Postsurgery"). Relative errors were calculated over 1-minute segment within each 10-minute period. Bias, precision, and accuracy were calculated using Bland-Altman analyses and paired-difference equivalence tests were performed. RESULTS: Combined across the Presurgery and Postsurgery periods, the RVM's mean measurement bias (RVM - NM3 measurement) for MV was -3.8% (95% limits of agreement) (±1.96 SD): (-19.9% to 12.2%), for TV it was -4.9 (-21.0% to 11.3%), and for RR it was 1.1% (-4.1% to 6.2%). The mean measurement accuracies for MV, TV, and RR were 11.9%, 12.0%, and 4.2% (0.6 breaths/min), respectively. Note that lower accuracy numbers correspond to more accurate RVM measurements. The equivalence tests rejected the null hypothesis that the RVM and NM3 have different mean values and conclude with 90% power that the measurements of MV, TV, and RR from the RVM and NM3 are equivalent within ±10%. CONCLUSIONS: Our data indicate acceptable agreement between RVM and NM3 measurements in pediatric mechanically-ventilated patients. Future studies assessing the capability of the RVM to detect respiratory compromise in other clinical settings are needed.


Subject(s)
Anesthesia, General/methods , Anesthesia, General/standards , Drug Monitoring/methods , Drug Monitoring/standards , Lung Volume Measurements/methods , Respiration, Artificial/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Prospective Studies , Respiration, Artificial/standards