1.
Braz. dent. j ; 33(3): 38-46, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1384033

ABSTRACT

Abstract This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.


Resumo Este estudo avaliou os instrumentos Reciproc R25 e Pro-R 25 sem uso, após um primeiro e um segundo uso em retratamento endodôntico com perfilômetro 3D por interferometria de luz sem contato, microscópio eletrônico de varredura (MEV) e testes de fadiga cíclica. Vinte dentes unirradiculares foram instrumentados com Reciproc R25 e obturados com guta-percha e cimento endodôntico. Um perfilômetro 3D com uma objetiva 20x usando o software Mx ™ foi usado para avaliar as superfícies da lâmina de corte do Reciproc e Pro-R (n = 5 por grupo) na condição sem uso, após o primeiro e após um segundo uso em procedimentos de retratamento. Após retratamento, o MEV foi usado para avaliar as características topográficas dos instrumentos utilizados. Testes de fadiga cíclica foram realizados para comparar instrumentos novos com instrumentos usados. O teste One-way ANOVA seguido pelo teste de Tukey foi usado para comparar os instrumentos testados nos diferentes estágios. Para comparar os diferentes instrumentos e para avaliação de fadiga cílcica, foi utilizado o Student t-test. Não foram observadas diferenças estatisticamente significantes nas superfícies das lâminas de corte dos instrumentos Reciproc e Pro-R antes e após um e dois usos (p> 0,05). O Reciproc na condição sem uso apresentou maior Sa e Sq quando comparado ao Pro-R (p <0,05). Não foram observadas diferenças entre Reciproc e Pro-R após um e dois usos (p> 0,05). O Reciproc sem uso apresentou maior tempo de fratura do que os instrumentos Pro-R (p<0,05), e apenas o Pro-R apresentou diferenças entre instrumentos novos e usados (p<0,05). Os procedimentos de retratamento com Reciproc e Pro-R não alteraram a topografia da superfície dos instrumentos. Reciproc apresentou maior resistência à fadiga cíclica em comparação com o Pro-R.

2.
Braz Dent J ; 33(3): 38-46, 2022.
Article in English | MEDLINE | ID: mdl-35766715

ABSTRACT

This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.


Subject(s)
Dental Instruments , Root Canal Preparation , Equipment Design , Gutta-Percha , Humans , Retreatment , Titanium
3.
Arch Oral Biol ; 115: 104737, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32387743

ABSTRACT

OBJECTIVE: Different studies in the last decade have proposed that gene expression alterations that are independent of the DNA sequence may also play an important role in periapical disease. The present study aimed to assess the available evidence supporting a relationship between these alterations and apical periodontitis through a scoping review. DESIGN: Specific strategies were developed for different databases (MEDLINE via PubMed, Cochrane Library, Scopus, Web of Science, and Virtual Health Library) and a search performed by March 1st, 2019. The evidence sources were selected according to the eligibility criteria and underwent a critical appraisal of methodological quality. RESULTS: The initial search retrieved 212 references, with eight eligible articles after the removal of replicates and application of exclusion criteria. Five studies identified altered DNA methylation on inflammatory response genes (FOXP3, CXCL3, FADD, MMP2, MMP9, IFNG, IL4, IL12) on AP patients. Three others identified the alterations on the expression of several microRNAs (miR-29b, 106b, 125b, 143, 146a, 155, 198) during AP. No evidence was identified regarding mechanisms of histone methylation, or of epigenetic heritability or stability. CONCLUSIONS: There is available evidence for the involvement of different genetic regulatory mechanisms independent of changes in DNA sequence in the development or severity of apical periodontitis. However, due to methodological limitations, further research must be performed before novel therapies and diagnostic tools for AP may arise from these data.


Subject(s)
Gene Expression Regulation , MicroRNAs , Periapical Periodontitis , Base Sequence , DNA Methylation , Humans , MicroRNAs/genetics , Periapical Periodontitis/genetics
4.
Iran Endod J ; 15(3): 124-139, 2020.
Article in English | MEDLINE | ID: mdl-36703804

ABSTRACT

Introduction: Irregularities and defects on NiTi endodontic instruments originating from the manufacturing process can lead to the structural collapse and fracture of these instruments during treatment. To assess the cause of instrument wear and fracture, as well as increasing fracture incidence, destructive and non-destructive methods have been used for the analysis of surfaces and internal structures of new and used NiTi instruments. The aim of this systematic review was to undertake a detailed analysis of the methods used to evaluate the surface and internal microstructure of endodontic instruments. Methods and Materials: The scientific literature was comprehensively and systematically searched in the MEDLINE (PubMed), Web of Science, Cochrane Library, Scopus, and LILACS/BBO databases for studies published up to June 9, 2019. The eligibility criteria was based on the PICO (Patient, Intervention, Comparison, and Outcome) strategy with the question "What is the best method for structural analysis of endodontic files?" Two aspects were considered for inclusion in this study: (i) endodontic instruments and (ii) methods for structural analysis of NiTi instruments. . The systematic review was performed according to the PRISMA statement. Results: Based on the inclusion criteria, 94 articles were selected. The results showed that although specific methods have been used for qualitative and/or quantitative structural analysis of NiTi instruments, no study addressed both the surface and internal structure of the instruments at the same time. According to this review, the need to compare the methodologies used in the selected articles has been identified; however, each type of method used has its own limitation on the analysis of both the surface and the internal structure of the instruments. Conclusions: The comparison between the different types of methodologies used in the studies revealed the reliability and the limitations of the methods employed for structural analysis of endodontic instruments; thus assisting us in determining their validity.

5.
Braz Dent J ; 27(5): 492-496, 2016.
Article in English | MEDLINE | ID: mdl-27982223

ABSTRACT

Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.


Subject(s)
Composite Resins , Gingiva/cytology , Fibroblasts/cytology , Humans
6.
Braz. dent. j ; 27(5): 492-496, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-828031

ABSTRACT

Abstract Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.


Resumo Resinas bisacrílicas são usadas em restaurações dentárias provisórias e têm mostrado vantagens em relação a outros materiais. O objetivo deste trabalho foi avaliar a citotoxicidade in vitro de duas resinas compostas bisacrílicas (Protemp 4 e Luxatemp Star), obtidas após 1, 7 e 40 dias da mistura com os componentes da resina, usando um ensaio padronizado empregando células primárias humanas fortemente relacionadas aos tecidos orais. Culturas de células de fibroblastos gengivais humanos foram expostas por 24 h aos extratos das resinas bisacrílicas, esferas de poliestireno (controle negativo) e látex (controle positivo), obtidos após diferentes períodos de incubação, a 37 °C e com 5% CO2. A viabilidade celular foi avaliada usando procedimentos multiparamétricos que envolvem a avaliação sequencial (usando as mesmas células) da atividade mitocondrial (ensaio XTT), a integridade de membrana (teste do vermelho neutro) e a densidade celular total (teste de exclusão do corante cristal violeta). As células expostas aos extratos mostraram viabilidade celular acima de 75% depois de 24 h. Mesmo quando as células foram expostas aos extratos com aumento do tempo de condicionamento, as resinas bisacrílicas não apresentaram efeitos citotóxicos significativos (p<0,05), comparadas ao grupo controle ou em relação às primeiras 24 h de contato com os produtos. Não houve diferença entre os resultados obtidos para as resinas bisacrílicas avaliadas entre as 24 h, 7 e 40 dias depois da mistura. Concluímos que as resinas bisacrílicas Protemp 4 e Luxatemp Star foram citocompatíveis com os fibroblastos gengivais humanos, sugerindo que ambos materiais são adequados para uso em contato com tecidos humanos.


Subject(s)
Humans , Composite Resins , Gingiva/cytology , Fibroblasts/cytology