Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
J Oral Rehabil ; 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38873742

ABSTRACT

BACKGROUND: Limited data exist on the mid- to long-term masticatory capacity of mandibular overdenture (IOD) wearers, particularly regarding the use of posterior implants to retention. OBJECTIVES: To periodically evaluate mastication of IOD wearers, comparing the effectiveness of two to four implants to retain the prosthesis. METHODS: In a randomised controlled clinical trial, 20 complete edentulous patients (14 women), aged 51-84 years (mean age 69.1 ± 9.6), received new bimaxillary complete dentures (CD). After adaptation, baseline measurements of masticatory performance (X50) and swallowing threshold were conducted using the sieving method. Patients were then randomly assigned to groups: control (two intra-foraminal regular implants) and experimental (two intra-foraminal regular implants and two extra-short posterior implants) (n = 10 each). After 4 months, implants were splinted, and a new mandibular IOD was fabricated with bar/clip retention. Mastication was reassessed after 6, 12, and 48 months, and data analysed with repeated measures ANOVA and Sidak's post hoc (α = 0.05). RESULTS: Despite a loss of two patients per group, masticatory performance significantly improved after mandibular IOD installation (p = .031) in both groups (p = .670). A second improvement was observed after 6 months (p = .027), with no subsequent changes (p > .05). Swallowing threshold improvements were noted with IOD, and no discernible differences between groups were observed (p > .05). CONCLUSION: Masticatory function significantly improved after mandibular IOD installation, with the number of implants demonstrating minimal influence. CLINICAL TRIAL REGISTRATION: The present study was not registered in a public database, as mandated. It is important to note that the recommendation for registration was initiated in 2017 by the Committee of Medical Journal Editors, while patient inclusion in the research took place in 2016. Given that the data presented in this manuscript cover a follow-up period of up to 4 years post-surgical intervention, delayed registration was not feasible.

2.
Dent Mater ; 40(1): 3-8, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37858419

ABSTRACT

OBJECTIVE: Inert surface of Polyetherketoneketone (PEKK) jeopardizes resin bonding. This study aimed to present a new adhesive protocol to improve PEKK bonding. METHODS: A total of 360 PEKK blocks were milled, polished (maximum roughness of 0.20 µm), and randomly assigned to groups. The new protocol was applied (n = 36) and compared to conventional treatments (no treatment; sandblasting (110-µm Al2O3 and silica); no adhesive; Visiolink (Bredent); and PEKKbond (AnaxDent)) (n = 36). For the new protocol, the surface was blasted (110 µm Al2O3 and 96% isopropyl alcohol at 60 psi), followed by 96% isopropyl alcohol washing, and air drying. PEKKbond was applied (dried for 3 min at 77 °C), followed by Visiolink (dried for 3 min at 60 °C); both light-cured for 3 min (800 mW/cm2). Preopaque (GC Europe) and Opaque (AnaxDent) were applied and light-cured (5 min). Morphological topography was analyzed, and flowable gingiva-colored composite (AnaxGum, AnaxDent) was bonded. All specimens were aged for 24 h and thermocycled (5000 cycles, 5-55 °C). Shear bond strength (SBS) was measured (MPa) and data were analyzed by two-way ANOVA, Tukey, and Weibull moduli estimation (α = 0.05). RESULTS: The highest SBS values were found in the new protocol (p < 0.05), regardless of aging. Thermocycling reduced SBS (p < 0.05), while Al2O3 and PEKKbond produced higher SBS values than silica and Visiolink, respectively (p < 0.05). SIGNIFICANCE: The new protocol strongly improves PEKK adhesiveness, and this can reflect in the longevity of prostheses.


Subject(s)
2-Propanol , Dental Bonding , Dental Bonding/methods , Resin Cements/chemistry , Dental Cements , Surface Properties , Shear Strength , Silicon Dioxide/chemistry , Materials Testing
3.
J Prosthet Dent ; 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38123418

ABSTRACT

A technique for fabricating lingual rest seats and indirect incisal restorations using a digital workflow is described. After intraoral scanning, the incisal edge position of the restoration and lingual rest seats for a subsequent removable partial denture (RPD) were designed digitally. Adaptation was evaluated with trial restorations, and definitive restorations were printed from a 3-dimensional resin (Varseo Smile Crown Plus Bego; Wilcos). The restorations were cemented with a heated composite resin (Tetric N; Ivoclar AG) polymerized for 40 seconds. The RPD was fabricated and delivered following a conventional technique. This standard, rapid, cost-effective, and straightforward approach allows a controlled and standardized process to obtain lingual rest seats and incisal restorations simultaneously, providing support for a successful Kennedy Class I RPD.

4.
J Prosthet Dent ; 130(2): 229-237, 2023 Aug.
Article in English | MEDLINE | ID: mdl-34756607

ABSTRACT

STATEMENT OF PROBLEM: The simplified technique has been recommended for the fabrication of removable complete dentures. However, a consensus regarding the performance of the simplified and the traditional techniques is lacking. PURPOSE: The purpose of this randomized clinical trial was to compare the performance of prostheses fabricated with the simplified and the traditional techniques. MATERIAL AND METHODS: Sixty participants were recruited and randomized into 2 groups: traditional technique (control group) and simplified technique (experimental group). The assessments were performed before treatment (baseline) and 2 and 4 months after adaptation to the new complete dentures. The variables evaluated were satisfaction, oral health-related quality of life (OHRQoL) by using the Brazilian version of the OHIP-EDENT, the quality of the prostheses, and, for the functional assessment, the masticatory performance and swallowing threshold. The data were analyzed by the Fisher exact test, the Mann-Whitney test, and the generalized equations estimating (GEE) method. RESULTS: At baseline, the mean ±standard deviation quality of the prostheses was 5.3 ±2.3 for the traditional technique and 4.9 ±2.3 for the simplified technique, and at 4 months, it was 9.3 ±0.9 and 9.1 ±0.9, respectively. For masticatory performance, the mean ±standard deviation X50 at baseline was 5.7 ±1.4 for the traditional technique and 5.7 ±0.9 for the simplified technique, and at 4 months, it was 3.8 ±1.2 and 3.7 ±0.9, respectively. The mean ±standard deviation OHRQoL at baseline was 14.1 ±8.6 for the traditional technique and 12.5 ±9.4 for the simplified technique, and at 4 months, it was 3.2 ±4.3 and 2.6 ±5.1, respectively. The mean ±standard deviation satisfaction at baseline was 9.5 ±3.9 for the traditional technique and 9.3 ±4.2 for the simplified technique; after 4 months, it was 14.8 ±2.0 for both techniques. There was a significant improvement (P<.05) for all variables in the study when comparing them at the baseline to those at the evaluation after provision of new complete dentures. There was no significant difference in all analyzed variables (P>.05) between the 2 techniques for prosthesis fabrication. CONCLUSIONS: The simplified technique appears to be a suitable alternative to the traditional technique for the fabrication of complete dentures, with similar performance.


Subject(s)
Patient Satisfaction , Quality of Life , Humans , Denture, Complete , Denture, Partial , Brazil , Mastication
5.
J Prosthet Dent ; 130(3): 351-361, 2023 Sep.
Article in English | MEDLINE | ID: mdl-34772484

ABSTRACT

STATEMENT OF PROBLEM: Denture adhesives improve the mastication of complete denture wearers. However, the impact of denture adhesives with different presentations on mastication remains unclear. PURPOSE: The purpose of this systematic review was to answer the focused question, "Do different presentations of denture adhesives affect the masticatory function of complete denture wearers?". MATERIAL AND METHODS: This review was guided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Six databases and the non-peer-reviewed literature were searched up to July 2021. Only clinical studies (randomized clinical trials and nonrandomized clinical trials) comparing the use of different denture adhesive presentations (cream, powder, or strips) were included, without language or follow-up restrictions. The risk of bias was assessed by using the Cochrane tools (RoB 2.0 and ROBINS-I). Masticatory performance, by using single and multiple sieves, masticatory performance with color-changing chewing gum (mixing ability), swallowing threshold (particle size and number of cycles), jaw kinematics, and occlusal force were considered. Meta-analyses were conducted to evaluate masticatory performance (single sieve) and occlusal force outcomes (α=.05), and the certainty of the evidence was determined with the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) evaluations. RESULTS: Nine studies (6 randomized and 3 nonrandomized clinical trials) were included. The risk of bias was considered moderate. Meta-analyses showed no differences between cream and powder denture adhesives for masticatory performance (standard mean difference=0.02; 95% CI=-0.46 to 0.50, P=.93) or between cream and strip denture adhesives for occlusal force (mean difference=14.35; 95% CI=-11.14 to 39.84, P=.27). Similarly, in qualitative analysis, cream and powder denture adhesives' performances were similar regarding masticatory performance with color-changing chewing gum (mixing ability), occlusal force, swallowing threshold (particle size and number of cycles), and jaw kinematics (P>.05). However, for resorbed ridges, cream denture adhesive resulted in a higher masticatory performance than strip (P<.05). When comparing powder to strip denture adhesives, the occlusal force was higher in the powder group (P<.05). The certainty of evidence was very low for all evaluated outcomes. CONCLUSIONS: Different presentations of denture adhesives seem to improve the masticatory function of complete denture wearers in a similar way. However, the qualitative analysis showed that, in patients with a resorbed ridge, a cream denture adhesive may be better than strips to improve mastication, although the certainty of evidence was very low.


Subject(s)
Chewing Gum , Denture, Complete , Humans , Powders , Bite Force , Mastication , Adhesives/therapeutic use
6.
J Prosthet Dent ; 2022 Apr 11.
Article in English | MEDLINE | ID: mdl-35422333

ABSTRACT

STATEMENT OF PROBLEM: High-performance polymers including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) have been used as substitutes for metal frameworks in dental prostheses. However, the clinical performance of polymer-based frameworks is still uncertain. PURPOSE: The purpose of this systematic review was to compare the clinical performance of PEEK and PEKK with that of metal frameworks for different dental prostheses. MATERIAL AND METHODS: This review follows the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Six databases and non-peer-reviewed literature (without language or follow-up restrictions) were searched for studies conducted before February 2022. Only clinical studies, either randomized clinical trials (RCTs) or nonrandomized clinical trials (N-RCTs), comparing the clinical performance of polymer and metal frameworks were included. The risk of bias and certainty of the evidence were assessed with the RoB 2.0, ROBINS-I, and GRADE. Biologic (plaque and gingival indices, probing depth, bleeding scores, implant stability quotient, marginal bone loss) and mechanical outcomes (ridge base relation, prosthetic marginal gap, and fracture) were assessed. RESULTS: Only 9 studies (7 RCTs and 2 N-RCTs) were included, all with moderate to serious risk of bias and low to very low certainty of evidence. No meta-analysis was possible, but qualitative analysis revealed lower plaque and gingival indices, probing depth, and marginal bone loss, with higher survival rates for implant-supported fixed prostheses and overdentures fabricated with PEEK than for metal frameworks. No significant differences were found between groups for removable partial dentures. The marginal fit of PEEK frameworks was also better for single crowns. Three fractures were reported in the 3 PEKK fixed dental prostheses with cantilevers. CONCLUSIONS: PEEK and PEKK seem to be promising materials for dental prostheses, with acceptable response from the periodontal tissue. However, further well-designed studies are necessary to better understand their clinical and long-term limitations.

7.
Clin Nutr ; 40(5): 3235-3249, 2021 05.
Article in English | MEDLINE | ID: mdl-33676775

ABSTRACT

BACKGROUND & AIMS: Debate still exists about the impact of dental implant-supported prostheses on nutritional status of partially and complete edentulous patients. This review aims to answer the focused question: "Do complete and partial edentulous patients, using implant-supported prostheses, present better nutritional and masticatory functions when compared to those using conventional rehabilitations?". A possible cause-effect relationship between masticatory improvements and nutritional gain was also evaluated. METHODS: Literature search included 6 databases (PubMed/Medline, Embase, LILACS, Scopus, Web of Science, and The Cochrane Library - CENTRAL), grey literature (Google Scholar, Proquest Dissertations and Thesis and Open Grey databases) and manual search (last update June 2020), without language, publication time and follow-up restrictions. We included only studies evaluating both masticatory and nutritional outcomes. The PICO question comprised complete and partial edentulous patients (Population), submitted to implant-supported prostheses (Intervention), in comparison to conventional dental prosthetic rehabilitation, evaluating masticatory function and nutrition parameters (outcomes). Risk of bias was assessed by using Cochrane Collaboration's tool (randomized clinical trials), Joanna Briggs Institute critical appraisal checklist (paired clinical trials), and Meta-Analysis of Statistics Assessment and Review Instrument" (JBI - MAStARI) critical appraisal tools (cohort studies). All meta-analyses were conducted at 5% level of significance. This report followed the PRISMA guidelines. (Review registration PROSPERO - CRD42019135744). RESULTS: We identified 1199 articles while searching databases. Fourteen articles met eligibility criteria, including 817 prostheses installed in 660 patients (mean age = 66.8 years-old). Patients wearing implant overdentures (IOD) presented better masticatory function in comparison to conventional complete denture (CD) wearers (p < 0.05). However, bioavailability of several nutrients remained within the same range, except for serum folate that was lower in IOD patients after 6 (mean difference 3.51 nmol/L; p = 0.01) and 12 months of rehabilitation (mean difference 3.69 nmol/L; p = 0.003). When comparing the effects of CD and IOD rehabilitations along time (for the same patient), serum albumin and vitamin B12 levels also decreased for both groups after 12 months-follow-up, but still within the reference range. The additional retention of the implants did not interfere in body weight, but reduced the risk of malnutrition (using the Mini Nutritional Assessment). Implant-supported partial prostheses also improved mastication in comparison to the conventional ones, increasing short-term daily intake of carbohydrates, protein, calcium, fiber, and iron, whereas decreasing the consumption of cholesterol. However, no long-term changes on bioavailability of most nutrients were observed, expect for a slight increase in ferritin and cholinesterase, and a small reduction in folate and Vitamin A. CONCLUSION: Current evidence indicates significant masticatory improvements for dental fixed implant-supported prostheses in comparison to conventional removable prostheses. However, bioavailability remained stable for most of the nutrients, especially for complete edentulous patients. These results indicate the importance of a multidisciplinary approach during oral rehabilitation (nutrient specialist), in order to enhance food choices and promote health benefits to the patients.


Subject(s)
Dental Implants , Mouth, Edentulous/physiopathology , Mouth, Edentulous/therapy , Nutrients/metabolism , Nutritional Status/physiology , Biological Availability , Humans , Mastication/physiology
8.
J Oral Rehabil ; 48(6): 745-761, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33638156

ABSTRACT

A large number of methodological procedures and experimental conditions are reported to describe the masticatory process. However, similar terms are sometimes employed to describe different methodologies. Standardisation of terms is essential to allow comparisons among different studies. This article was aimed to provide a consensus concerning the terms, definitions and technical methods generally reported when evaluating masticatory function objectively and subjectively. The consensus is based on the results from discussions and consultations among world-leading researchers in the related research areas. Advantages, limitations and relevance of each method are also discussed. The present consensus provides a revised framework of standardised terms to improve the consistent use of masticatory terminology and facilitate further investigations on masticatory function analysis. In addition, this article also outlines various methods used to evaluate the masticatory process and their advantages and disadvantages in order to help researchers to design their experiments.


Subject(s)
Mastication , Consensus , Humans
9.
Dent Mater ; 36(4): e93-e108, 2020 04.
Article in English | MEDLINE | ID: mdl-32035670

ABSTRACT

OBJECTIVE: The aim of this systemic review, conducted in accordance with the PRISMA statement, was to investigate the impact of surface pretreatments on the bonding strength of high performance polymers (HPPs). METHODS: Eight databases were searched through March 2019. Risk of bias was assessed and random effects meta-analyses were applied to analyze mean differences in shear bond strength (SBS) and tensile bond strength (TBS), considering surface pretreatments and bonding agents after 24h and thermocycling. RESULTS: A total of 235 relevant titles and abstracts were found, yielding 11 final selections. Low risk of bias was observed in most studies. For polyetheretherketone (PEEK) specimens, random-effect models showed that, compared to non-treated controls, pretreatments associated with Visio.link® (Bredent, Senden, GE) increased TBS by 26.72MPa (95% confidence interval (CI), 19.69-33.76; p<0.00001) and increased SBS by 4.86MPa (95% CI, 2.61-7.10; p<0.00001). Air abrasion improved SBS by 4.90MPa (95% CI, 3.90-5.90; p<0.00001) (50µm alumina) and 4.51MPa (95% CI, 1.85-7.18; p=0.0009) (silica-coated CoJet). In comparison to non-treated controls, Visio.link® and Signum PEEK Bond® (Heraeus Kulzer, Hanau, GE) increased SBS by 33.76MPa (95% CI, 18.72-48.81; p<0.00001) and 33.28MPa (95% CI, 17.48-49.07; p<0.00001), respectively. No differences were found between Visio.link® and Signum PEEK Bond® or Monobond Plus/Heliobond® (Ivoclar Vivadent, Schaan, LH) (p>0.05). Similar results were observed for polyetherketoneketone (PEKK) specimens. SIGNIFICANCE: This review shows improved HPP bonding following the application of various surface pretreatments, including air abrasion and bonding agents.


Subject(s)
Dental Bonding , Polymers , Resin Cements , Air Abrasion, Dental , Materials Testing , Shear Strength , Surface Properties , Tensile Strength
10.
Int J Oral Maxillofac Implants ; 34(6): 1347­1358, 2019.
Article in English | MEDLINE | ID: mdl-30934032

ABSTRACT

PURPOSE: Implants in the anterior region are challenging, and literature reporting outcomes of narrow-diameter implants (NDIs) in anterior sites is scarce. This systematic review summarized evidence of functional and esthetic performance of anterior single crowns supported by NDIs. MATERIALS AND METHODS: Ten databases were searched to find studies evaluating anterior single crowns supported by NDIs. Risk of bias was assessed, and random-effects meta-analyses were applied to analyze mean differences in survival, success, and marginal bone level (MBL). The review was registered in the PROSPERO database (CRD42018089886). RESULTS: Twenty-one studies meeting the screening criteria were included for qualitative analysis, and three for meta-analysis. A total of 892 NDIs, placed in 736 patients, were analyzed. Follow-up duration varied from 12 months to 14 years (mean: 40 months), and 16 failures (implant loss) were recorded. Fixed-effect meta-analysis (I2 = 0%) of survival rate revealed a risk difference of 0.02 (95% CI: -0.03 to 0.08), between NDIs and controls (regular-diameter implants), without differences between groups (P = .39). Success rates ranged from 84.2% to 100% (mean: 95.2%). Random-effects meta-analysis (I2 = 56%) of MBL indicated a mean difference of 0.02 mm (95% CI: -0.21 to 0.25), without differences between groups (P = .87). CONCLUSION: Single crowns supported by NDIs are a predictable treatment, since their survival rate and MBL are comparable to those supported by regular-diameter implants. Due to data shortage reporting esthetic outcomes, more studies are needed to evaluate the long-term performance of the single crowns supported by NDIs in the anterior region.


Subject(s)
Alveolar Bone Loss , Dental Implants , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Crowns , Dental Restoration Failure , Esthetics, Dental , Follow-Up Studies , Humans
11.
J Oral Rehabil ; 46(7): 640-646, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30868605

ABSTRACT

BACKGROUND: Spherical shape and connecting bypass screw of the OT Equator abutment (Rhein83, Italy) provides several retentive possibilities, even in non-parallel implants. OBJECTIVE: This study assessed the long-term survival of standard-length and short implants receiving this multifunctional abutment. METHODS: Partially, edentulous patients (44 males and 64 females) (mean age 58.2 ± 10.5 years) rehabilitated with a fixed implant-supported prosthesis where the OT Equator abutments (Rhein83) were applied. Follow-up evaluations were performed up to 5 years following prosthesis delivery. Kaplan-Meier survival analysis and Cox regression analysis were used to determine whether the distribution of time to failure differed based on implant characteristics (length and region), adjusting for sex (α = 0.05). RESULTS: In total, 216 implants (5 × 8 mm, n = 126; 5 × 6 mm, n = 90) (Betwice, Mech & Human, Italy) were installed. The average follow-up period was 25.3 months (±19.3 months). Eight failures occurred, with most observed before loading (n = 6). Cumulative survival rates (CSR) at implant and abutment levels were 94.3% and 97.1%, respectively. Regarding implant length, CSRs were 97.8% and 90.6% for short and standard-length implants, respectively, with no difference between subgroups (logrank: χ2  = 1.34, df = 1, P = 0.25). No significant difference was also found between implants of maxilla (CSR = 92.2%) and mandible (CSR = 95.5%; logrank: χ2  = 0.08, df = 1, P = 0.78). CONCLUSION: The OT Equator abutment (Rhein83) showed a stable clinical performance, with continuous and predictable survival.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Aged , Dental Abutments , Dental Prosthesis Design , Dental Restoration Failure , Female , Follow-Up Studies , Humans , Italy , Male , Middle Aged , Survival Analysis , Treatment Outcome
12.
Int J Oral Maxillofac Implants ; 34(4): 873­885, 2019.
Article in English | MEDLINE | ID: mdl-30768659

ABSTRACT

PURPOSE: To evaluate, through a systematic review of the literature, the published data regarding marginal bone loss, implant failure proportion, biologic and prosthetic complications, and risk factors associated with short (≤ 8-mm) implants supporting fixed or removable full-arch restorations in the edentulous mandible. MATERIALS AND METHODS: Two reviewers performed a search of five databases, with handsearching through the reference lists and grey literature. Controlled clinical trials and prospective cohort studies were selected in a two-phase process. The data were independently gathered for the same two reviewers. Quality assessment of the studies was done using the Cochrane Handbook for Systematic Reviews of Interventions for Randomized Clinical Trials and the Newcastle-Ottawa Scale for Prospective Cohort Studies. Marginal bone loss and Implant failure proportion were meta-analyzed using random (R-Em) and fixed-effects models (FEm), respectively, with a 95% confidence interval. A descriptive analysis was performed of the prevalence of biologic and prosthetic complications. Meta-regression analysis was run as fixed-effect models for risk factors. RESULTS: Six studies met the eligibility criteria and had data extracted. A total of 291 short implants (lengths 5 to 8 mm) were placed in 122 patients (82 females; mean age, 64.7 ± 10.8) supporting 23 fixed and 99 removable full-arch restorations. The pooled marginal bone loss overall was 0.12 mm (0.07 to 0.17 mm). Marginal bone loss for fixed full-arch restorations was 0.11 mm (0.01 to 0.21 mm) and for removable full-arch restorations was 0.14 mm (0.07 to 0.21 mm). The pooled implant failure proportion was 2.0% (1.0% to 5.0%) for the overall studies. Implant failure proportion for fixed and removable restorations was 2.0% with a confidence interval of (0.0% to 9%) and (0.0% to 6%), respectively. The prevalence of prosthetic complications was 34.5% for fixed restorations and 2.6% for removable restorations. No biologic complications were found for fixed restorations, while 13.1% of removable restorations did have biologic complications. Risk factors did not demonstrate statistical differences regarding Implant failure proportion and marginal bone loss. All included studies demonstrated a high methodological quality. CONCLUSION: Findings from this systematic review and meta-analysis suggest that full-arch restorations supported by short implants in atrophic edentulous mandibles might be a viable treatment option, presenting minimal marginal bone loss and implant failure in the short-term. However, further well-performed prospective clinical trials with long-term observation are needed.


Subject(s)
Dental Implants , Aged , Dental Implantation, Endosseous , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Female , Humans , Male , Mandible , Middle Aged , Prospective Studies
13.
J Oral Rehabil ; 46(2): 127-133, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30307639

ABSTRACT

BACKGROUND: Edentulism can reduce mastication, leading to changes in food pattern, with possible consequences to masticatory muscle thickness. OBJECTIVES: This study verified masticatory function and oral perception in subjects who did not use lower CDs, and whether the insertion of new upper and lower CDs would improve such variables. METHODS: Fifteen edentulous elderly who wore only the upper CD were selected and received new upper and lower CD. Volunteers were evaluated at baseline and after 1, 3 and 6 months of new prosthesis use. Masticatory performance (MP) was assessed by the sieving method (X50 values). Masseter thickness (MT) was evaluated by ultrasonography. Oral sensorial ability (OSA) was assessed by oral stereognosis test and maximum tongue pressure (MTP) was verified by pressure sensors. Data were submitted to repeated measures ANOVA and Tukey-Kramer posthoc tests (α = 0.05). Correlation between OSA and MTP was verified by Person's correlation. RESULTS: X50 and MTP decreased (P < 0.05) after 1 month and remained stable (P > 0.05) for next assessments. After 3 months, MT in rest position was increased (P < 0.05), while during maximum voluntary contraction 1 month was enough to increase MT (P < 0.05). There were no differences for OSA (P > 0.05) and no correlation between OSA and MTP. CONCLUSION: Masticatory performance and masseter thickness of elderly who did not use the lower dentures were improved after 2 months using new upper and lower CDs. However, new CDs in both dental arch decreased MTP. Brazilian Registry of Clinical Trials (ReBEC #RBR-37gdst).


Subject(s)
Denture, Complete, Lower , Masseter Muscle/physiology , Mastication/physiology , Mouth, Edentulous/rehabilitation , Aged , Analysis of Variance , Bite Force , Female , Humans , Longitudinal Studies , Male , Prospective Studies , Treatment Outcome
14.
Am J Dent ; 31(4): 199-204, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30106536

ABSTRACT

PURPOSE: To evaluate the in vitro effects of the Composite Primer and different surface treatments on the shear bond strength (SBS) of acrylic and bis-acryl repairs with resin composite (RC). METHODS: Acrylic (Alike) and bis-acryl (Protemp 4) blocks were prepared. Surface roughness was standardized (0.16 µm) and grit blasting was applied to half of the samples. Blocks were divided randomly into groups according to surface treatment [methyl methacrylate monomer (MMA) for 180 seconds or bonding agents (Composite Primer and Scotchbond Multi Purpose), applied alone or following MMA]. Two consistencies of RC [ regular (Filtek Z350XT and Solare composite) or flowable (Filtek Z350XT flowable and G-aenial flowable composite) ] were used to test bond repair. Cylinders (2 mm diameter) of each RC (n= 10/group) were attached to the block surface, and SBS was measured using a universal testing machine at 0.5 mm/minute. Failure (adhesive, cohesive or mixed) was assessed under ×3.5 magnification. SBS data were analyzed using factorial ANOVA, followed by Tukey post-hoc, and Weibull moduli estimation (α = 0.05). RESULTS: The highest SBS, Weibull modulus (m) and scale parameter (σ0) were found in combined use of MMA and bonding agents (P< 0.001), regardless of the substrate, RC consistency or brand. The use of the Composite Primer and flowable RC also increased SBS (P< 0.001). Significant interaction between surface treatment and RC consistency was observed for the PMMA substrate (P< 0.001). Sandblasting did not influence SBS (P> 0.05). Adhesive failure was most prevalent (93.5%) and SBS values were significantly higher in mixed fractures (19.2± 3.8 MPa) compared to the adhesive ones (9.7± 6.0 MPa) (P< 0.001). No cohesive fracture was observed. CLINICAL SIGNIFICANCE: Composite Primer improved the adhesion of acrylic and bis-acryl repairs, especially when a flowable composite was used. When such product is not available, the combined use of MMA and a bonding agent is necessary, increasing the number of clinical steps, cost, and time required.


Subject(s)
Acrylic Resins , Dental Bonding , Resin Cements , Composite Resins , Dental Stress Analysis , Materials Testing , Polymethyl Methacrylate , Random Allocation , Shear Strength , Surface Properties
15.
Prosthes. Lab. Sci ; 6(23): 13-18, abr.-jun. 2017. ilus
Article in Portuguese | BBO - Dentistry | ID: biblio-877254

ABSTRACT

A utilização da fotografia digital em Odontologia, para diagnóstico e tratamento de casos complexos, aumenta a previsibilidade dos desfechos, a compreensão por parte do paciente frente às possibilidades de resolução e diminui a incorporação de erros ao processo.


The use of the digital photography in Dentistry, for both diagnosis and treatment planning of complex cases, increases the predictability of the outcomes, and patients' understanding about the possibilities of resolution, as well as reduces the occurrence of errors along the process.


Subject(s)
Humans , Computer-Aided Design , Dental Prosthesis Design , Denture, Complete , Photography, Dental , Technology, Dental
16.
Braz Dent J ; 26(5): 463-7, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26647929

ABSTRACT

This study aimed to evaluate oral health-related quality of life (OHRQoL) in partially dentate subjects, presenting extreme tooth loss in posterior region with missing post-canines, comparing the use of conventional removable partial dentures (RPDs) and implant-supported RPDs. OHRQoL was measured using the Brazilian version of the Oral Health Impact Profile. Twelve subjects presenting maxillary total and mandibular Kennedy Class I edentulism (mean age 62.6±7.8 years) first received complete maxillary dentures and conventional mandibular free-end RPDs. After two months, the subjects had their OHRQoL assessed. Osseointegrated implants were inserted bilaterally in the mandibular first molar regions, and after four months ball abutments were placed to support the free-end RPD. Two months later, the patients had their OHRQoL reassessed. Wilcoxon signed-rank test was used to evaluate differences in OHRQoL (α=0.05). Results showed improvement in all OHIP-49 domains (p<0.05) after associating implants to the RPD. The mandibular implant-supported free-end RPD significantly improved OHRQoL.


Subject(s)
Dental Implants , Denture, Partial , Mouth, Edentulous/rehabilitation , Quality of Life , Aged , Humans , Middle Aged , Mouth, Edentulous/physiopathology
17.
Braz. dent. j ; 26(5): 463-467, Oct. 2015. tab
Article in English | LILACS | ID: lil-767633

ABSTRACT

Abstract: This study aimed to evaluate oral health-related quality of life (OHRQoL) in partially dentate subjects, presenting extreme tooth loss in posterior region with missing post-canines, comparing the use of conventional removable partial dentures (RPDs) and implant-supported RPDs. OHRQoL was measured using the Brazilian version of the Oral Health Impact Profile. Twelve subjects presenting maxillary total and mandibular Kennedy Class I edentulism (mean age 62.6±7.8 years) first received complete maxillary dentures and conventional mandibular free-end RPDs. After two months, the subjects had their OHRQoL assessed. Osseointegrated implants were inserted bilaterally in the mandibular first molar regions, and after four months ball abutments were placed to support the free-end RPD. Two months later, the patients had their OHRQoL reassessed. Wilcoxon signed-rank test was used to evaluate differences in OHRQoL (α=0.05). Results showed improvement in all OHIP-49 domains (p<0.05) after associating implants to the RPD. The mandibular implant-supported free-end RPD significantly improved OHRQoL.


Resumo: Este estudo avaliou a qualidade de vida relacionada à saúde bucal (QVRSB) em indivíduos parcialmente dentados, apresentando perda extrema de dentes na região posterior com ausência de dentes pós-caninos, comparando a reabilitação por meio de próteses parciais removíveis convencionais (PPRs) e PPRs implanto-suportadas. A QVRSB foi mensurada utilizando a versão brasileira do Oral Health Impact Profile (OHIP-49). Doze indivíduos apresentando edentulismo total maxilar e Classe I de Kennedy mandibular (idade média 62,6±7,8 anos) receberam primeiramente próteses totais maxilares e PPRs mandibulares convencionais de extremidade livre. Após dois meses de uso destas próteses, a QVRSB dos voluntários foi avaliada. Implantes osseointegrados foram bilateralmente instalados na região de primeiros molares inferiores e, após quatro meses, pilares do tipo bola foram instalados para suportar a extremidade livre da PPR. Após dois meses a QVRSB dos voluntários foi reavaliada. O teste pareado de Wilcoxon foi utilizado para avaliar as diferenças de QVRSB (α=0,05). Os resultados mostraram melhora em todos os domínios do OHIP-49 (p<0,05) após a associação dos implantes à PPR. PPRs de extremidade livre mandibulares implanto-suportadas melhorou significativamente a QVRSB.


Subject(s)
Humans , Middle Aged , Aged , Dental Implants , Denture, Partial , Mouth, Edentulous/rehabilitation , Mouth, Edentulous/physiopathology , Quality of Life
18.
Braz Dent J ; 26(4): 325-36, 2015.
Article in English | MEDLINE | ID: mdl-26312967

ABSTRACT

Lack of standard criteria in the outcome assessment makes it difficult to draw conclusions on the clinical performance of short implants and, under these circumstances, determine the reasons for implant failure. This study evaluated, through a systematic review of the literature and meta-analysis, the essential parameters required to assess the long-term clinical performance of short and extra-short implants. Electronic databases (Pubmed-MEDLINE, Cochrane Library Database, Embase, and Lilacs) were searched by two independent reviewers, without language limitation, to identify eligible papers. References from the selected articles were also reviewed. The review included clinical trials involving short dental implants placed in humans, published between January 2000 and March 2014, which described the parameters applied for outcome's measurements and provided data on survival rates. Thirteen methodologically acceptable studies were selected and 24 parameters were identified. The most frequent parameters assessed were the marginal bone loss and the cumulative implant survival rate, followed by implant failure rate and biological complications such as bleeding on probing and probing pocket depths. Only cumulative implant survival rate data allows meta-analysis revealing a positive effect size (from 0.052 (fixed) to 0.042 (random)), which means that short implant appears to be a successful treatment option. Mechanical complications and crown-to-implant (C/I) ratio measurement were also commonly described, however, considering the available evidence; no strong conclusions could be drawn since different methods were used to assess each parameter. By means of this literature review, a standard evaluation scheme is proposed, being helpful to regiment further investigations and comparisons on future studies.


Subject(s)
Dental Implants , Clinical Trials as Topic , Humans
19.
Braz. dent. j ; 26(4): 325-336, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-756393

ABSTRACT

Lack of standard criteria in the outcome assessment makes it difficult to draw conclusions on the clinical performance of short implants and, under these circumstances, determine the reasons for implant failure. This study evaluated, through a systematic review of the literature and meta-analysis, the essential parameters required to assess the long-term clinical performance of short and extra-short implants. Electronic databases (Pubmed-MEDLINE, Cochrane Library Database, Embase, and Lilacs) were searched by two independent reviewers, without language limitation, to identify eligible papers. References from the selected articles were also reviewed. The review included clinical trials involving short dental implants placed in humans, published between January 2000 and March 2014, which described the parameters applied for outcome's measurements and provided data on survival rates. Thirteen methodologically acceptable studies were selected and 24 parameters were identified. The most frequent parameters assessed were the marginal bone loss and the cumulative implant survival rate, followed by implant failure rate and biological complications such as bleeding on probing and probing pocket depths. Only cumulative implant survival rate data allows meta-analysis revealing a positive effect size (from 0.052 (fixed) to 0.042 (random)), which means that short implant appears to be a successful treatment option. Mechanical complications and crown-to-implant (C/I) ratio measurement were also commonly described, however, considering the available evidence; no strong conclusions could be drawn since different methods were used to assess each parameter. By means of this literature review, a standard evaluation scheme is proposed, being helpful to regiment further investigations and comparisons on future studies.

.

A falta de critérios padronizados para a avaliação dos resultados faz com que seja difícil tirar conclusões sobre o desempenho clínico dos implantes curtos e, nestas circunstâncias, determinar as razões para o fracasso do implante. Este estudo avaliou, através de uma revisão sistemática da literatura, os parâmetros essenciais necessários para avaliar o desempenho clínico em longo prazo de implantes curtos e extra-curtos. Bases de dados eletrônicas (PubMed-MEDLINE, Base de dados da Biblioteca Cochrane, Embase e Lilacs) foram avaliadas por dois revisores independentes, sem limitação da linguagem, de modo a identificar artigos elegíveis. As referências dos artigos selecionados foram também analisadas. A revisão incluiu estudos clínicos, publicados entre janeiro de 2000 e março de 2014, envolvendo implantes dentais curtos, instalados em seres humanos, nos quais foram descritos os parâmetros utilizados para mensuração dos resultados e fornecidos dados sobre as taxas de sobrevivência. Treze estudos metodologicamente aceitáveis foram selecionados, sendo identificados 24 parâmetros. Os parâmetros avaliados com maior frequencia foram a perda óssea marginal e a taxa cumulativa de sobrevivência do implante, seguida pela taxa de falha dos implantes e complicações biológicas, tais como sangramento à sondagem e profundidade de sondagem. Apenas a taxa cumulativa de sobrevivência dos implantes permitiu a meta-análise revelando efeito positivo (variação de 0.052 (efeito fixo) até 0.042 (efeito aleatório)), demonstrando que os implantes curtos parecem ser uma opção de tratamento bem sucedida. Complicações mecânicas e a mensuração da proporção coroa-implante foram também referidas, entretanto, considerando-se as evidências disponíveis, não se pode chegar a fortes conclusões, pois diferentes métodos foram utilizados para avaliar cada parâmetro. Por meio desta revisão da literatura, um esquema padronizado de avaliação é proposto, sendo útil para arregimentar ...


Subject(s)
Humans , Dental Implants , Clinical Trials as Topic
20.
Int J Oral Maxillofac Implants ; 30(2): 391-6, 2015.
Article in English | MEDLINE | ID: mdl-25830400

ABSTRACT

PURPOSE: This study evaluated the effects of different implant-based prostheses on swallowing threshold, dietary intake, and oral health-related quality of life (OHRQoL). MATERIALS AND METHODS: This prospective paired controlled clinical trial followed partially edentulous subjects, who sequentially used implant-supported removable partial dentures and implant-supported fixed partial dentures (IFPDs). Swallowing threshold was assessed by counting the masticatory cycles and median particle size (X50) calculation. Nutritional intake was verified by a 3-day food record. OHRQoL was measured with the Oral Health Impact Profile (OHIP-49). Data were evaluated with repeated-measures analysis of variance. RESULTS: Twelve subjects (mean age 62.6 ± 7.8 years; range, 55 to 87) took part in the study. IFPD treatment significantly reduced X50 values and the number of chewing cycles. Higher intake of fiber, calcium, and iron and lower consumption of cholesterol-rich food were observed after IFPD use. OHIP summary score and OHIP physical pain domain were lower with the IFPD. CONCLUSION: IFPD use leads to more efficient mastication and improves dietary intake and OHRQoL. This information will guide dentists to better clinical management of partially edentulous patients.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Denture, Partial, Removable , Mastication , Mouth, Edentulous/surgery , Adult , Aged , Aged, 80 and over , Eating , Female , Humans , Male , Middle Aged , Nutritional Status , Oral Health , Prospective Studies , Quality of Life , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...