Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
2.
Med Phys ; 50(11): 7027-7038, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37245075

ABSTRACT

BACKGROUND: T2 * mapping can characterize tumor hypoxia, which may be associated with resistance to therapy. Acquiring T2 * maps during MR-guided radiotherapy could inform treatment adaptation by, for example, escalating the dose to resistant sub-volumes. PURPOSE: The purpose of this work is to demonstrate the feasibility of the accelerated T2 * mapping technique using model-based image reconstruction with integrated trajectory auto-correction (TrACR) for MR-guided radiotherapy on an MR-Linear accelerator (MR-Linac). MATERIALS AND METHODS: The proposed method was validated in a numerical phantom, where two T2 * mapping approaches (sequential and joint) were compared for different noise levels (0,0.1,0.5,1) and gradient delays ([1, -1] and [1, -2] in units of dwell time for x- and y-axis, respectively). Fully sampled k-space was retrospectively undersampled using two different undersampling patterns. Root mean square errors (RMSEs) were calculated between reconstructed T2 * maps and ground truth. In vivo data was acquired twice weekly in one prostate and one head and neck cancer patient undergoing treatment on a 1.5 T MR-Linac. Data were retrospectively undersampled and T2 * maps reconstructed, with and without trajectory corrections were compared. RESULTS: Numerical simulations demonstrated that, for all noise levels, T2 * maps reconstructed with a joint approach demonstrated less error compared to an uncorrected and sequential approach. For a noise level of 0.1, uniform undersampling and gradient delay [1, -1] (in units of dwell time for x- and y-axis, respectively), RMSEs for sequential and joint approaches were 13.01 and 9.32 ms, respectively, which reduced to 10.92 and 5.89 ms for a gradient delay of [1, 2]. Similarly, for alternate undersampling and gradient delay [1, -1], RMSEs for sequential and joint approaches were 9.80 and 8.90 ms, respectively, which reduced to 9.10 and 5.40 ms for gradient delay [1, 2]. For in vivo data, T2 * maps reconstructed with our proposed approach resulted in less artifacts and improved visual appearance compared to the uncorrected approach. For both prostate and head and neck cancer patients, T2 * maps reconstructed from different treatment fractions showed changes within the planning target volume (PTV). CONCLUSION: Using the proposed approach, a retrospective data-driven gradient delay correction can be performed, which is particularly relevant for hybrid devices, where full information on the machine configuration is not available for image reconstruction. T2 * maps were acquired in under 5 min and can be integrated into MR-guided radiotherapy treatment workflows, which minimizes patient burden and leaves time for additional imaging for online adaptive radiotherapy on an MR-Linac.


Subject(s)
Head and Neck Neoplasms , Magnetic Resonance Imaging , Male , Humans , Retrospective Studies , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Particle Accelerators
3.
Eur Radiol ; 33(9): 6204-6212, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37017702

ABSTRACT

OBJECTIVES: To investigate whether MRI-based measurements of fibro-glandular tissue volume, breast density (MRBD), and background parenchymal enhancement (BPE) could be used to stratify two cohorts of healthy women: BRCA carriers and women at population risk of breast cancer. METHODS: Pre-menopausal women aged 40-50 years old were scanned at 3 T, employing a standard breast protocol including a DCE-MRI (35 and 30 participants in high- and low-risk groups, respectively). The dynamic range of the DCE protocol was characterised and both breasts were masked and segmented with minimal user input to produce measurements of fibro-glandular tissue volume, MRBD, and voxelwise BPE. Statistical tests were performed to determine inter- and intra-user repeatability, evaluate the symmetry between metrics derived from left and right breasts, and investigate MRBD and BPE differences between the high- and low-risk cohorts. RESULTS: Intra- and inter-user reproducibility in estimates of fibro-glandular tissue volume, MRBD, and median BPE estimations were good, with coefficients of variation < 15%. Coefficients of variation between left and right breasts were also low (< 25%). There were no significant correlations between fibro-glandular tissue volume, MRBD, and BPE for either risk group. However, the high-risk group had higher BPE kurtosis, although linear regression analysis did not reveal significant associations between BPE kurtosis and breast cancer risk. CONCLUSIONS: This study found no significant differences or correlations in fibro-glandular tissue volume, MRBD, or BPE metrics between the two groups of women with different levels of breast cancer risk. However, the results support further investigation into the heterogeneity of parenchymal enhancement. KEY POINTS: • A semi-automated method enabled quantitative measurements of fibro-glandular tissue volume, breast density, and background parenchymal enhancement with minimal user intervention. • Background parenchymal enhancement was quantified over the entire parenchyma, segmented in pre-contrast images, thus avoiding region selection. • No significant differences and correlations in fibro-glandular tissue volume, breast density, and breast background parenchymal enhancement were found between two cohorts of women at high and low levels of breast cancer risk.


Subject(s)
Breast Neoplasms , Breast , Female , Humans , Adult , Middle Aged , Reproducibility of Results , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Breast Density , Magnetic Resonance Imaging/methods , Retrospective Studies
4.
Magn Reson Med ; 88(6): 2592-2608, 2022 12.
Article in English | MEDLINE | ID: mdl-36128894

ABSTRACT

Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain. In the treatment planning phase, radiological images are essential for defining target volumes and organs-at-risk, as well as providing elemental composition (e.g., electron density) information for radiation dose calculations. At treatment, onboard imaging informs patient setup and could be used to guide radiation dose placement for sites affected by motion. Imaging is also an important tool for treatment response assessment and treatment plan adaptation. MRI, with its excellent soft tissue contrast and capacity to probe functional tissue properties, holds great untapped potential for transforming treatment paradigms in radiation therapy. The MR in Radiation Therapy ISMRM Study Group was established to provide a forum within the MR community to discuss the unmet needs and fuel opportunities for further advancement of MRI for radiation therapy applications. During the summer of 2021, the study group organized its first virtual workshop, attended by a diverse international group of clinicians, scientists, and clinical physicists, to explore our predictions for the future of MRI in radiation therapy for the next 25 years. This article reviews the main findings from the event and considers the opportunities and challenges of reaching our vision for the future in this expanding field.


Subject(s)
Neoplasms , Radiotherapy Planning, Computer-Assisted , Humans , Magnetic Resonance Imaging/methods , Motion , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods
5.
Br J Radiol ; 93(1106): 20190639, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-31674798

ABSTRACT

OBJECTIVE: To present and evaluate an automated method to correct scaling between Dixon water/fat images used in breast density (BD) assessments. METHODS: Dixon images were acquired in 14 subjects with different T1 weightings (flip angles, FA, 4°/16°). Our method corrects intensity differences between water (W) and fat (F) images via the application of a uniform scaling factor (SF), determined subject-by-subject. Based on the postulation that optimal SFs yield relatively featureless summed fat/scaled-water (F+WSF) images, each SF was chosen as that which generated the lowest 95th-percentile in the absolute spatial-gradient image-volume of F+WSF . Water-fraction maps were calculated for data acquired with low/high FAs, and BD (%) was the total percentage water within each breast volume. RESULTS: Corrected/uncorrected BD ranged from, respectively, 10.9-71.8%/8.9-66.7% for low-FA data to 8.1-74.3%/5.6-54.3% for high-FA data. Corrected metrics had an average absolute increase in BD of 6.4% for low-FA data and 18.4% for high-FA data. BD values estimated from low- and high-FA data were closer following SF-correction. CONCLUSION: Our results demonstrate need for scaling in such BD assessments, where our method brought high-FA and low-FA data into closer agreement. ADVANCES IN KNOWLEDGE: We demonstrated a feasible method to address a main source of inaccuracy in Dixon-based BD measurements.


Subject(s)
Breast Density , Breast Neoplasms/pathology , Adipose Tissue , Female , Humans , Magnetic Resonance Imaging/methods , Water
6.
Magn Reson Med ; 83(6): 2243-2252, 2020 06.
Article in English | MEDLINE | ID: mdl-31737935

ABSTRACT

PURPOSE: To compare prostate diffusional kurtosis imaging (DKI) metrics generated using phase-corrected real data with those generated using magnitude data with and without noise compensation (NC). METHODS: Diffusion-weighted images were acquired at 3T in 16 prostate cancer patients, measuring 6 b-values (0-1500 s/mm2 ), each acquired with 6 signal averages along 3 diffusion directions, with noise-only images acquired to allow NC. In addition to conventional magnitude averaging, phase-corrected real data were averaged in an attempt to reduce rician noise-bias, with a range of phase-correction low-pass filter (LPF) sizes (8-128 pixels) tested. Each method was also tested using simulations. Pixelwise maps of apparent diffusion (D) and apparent kurtosis (K) were calculated for magnitude data with and without NC and phase-corrected real data. Average values were compared in tumor, normal transition zone (NTZ), and normal peripheral zone (NPZ). RESULTS: Simulations indicated LPF size can strongly affect K metrics, where 64-pixel LPFs produced accurate metrics. Relative to metrics estimated from magnitude data without NC, median NC K were lower (P < 0.0001) by 6/11/8% in tumor/NPZ/NTZ, 64-LPF real-data K were lower (P < 0.0001) by 4/10/7%, respectively. CONCLUSION: Compared with magnitude data with NC, phase-corrected real data can produce similar K, although the choice of phase-correction LPF should be chosen carefully.


Subject(s)
Diffusion Magnetic Resonance Imaging , Prostatic Neoplasms , Diffusion , Diffusion Tensor Imaging , Humans , Male , Prostatic Neoplasms/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL