Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

2.
Sci Rep ; 14(1): 10409, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710782

ABSTRACT

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Transcatheter Aortic Valve Replacement/methods , Humans , Male , Female , Aged, 80 and over , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Aorta/diagnostic imaging , Aorta/surgery , Treatment Outcome , Heart Valve Prosthesis , Retrospective Studies
3.
Catheter Cardiovasc Interv ; 102(6): 1122-1131, 2023 11.
Article in English | MEDLINE | ID: mdl-37794734

ABSTRACT

BACKGROUND: The incidence and predictors of 30-day stroke after transcatheter aortic valve replacement (TAVR) were derived from early studies investigating first-generation devices. The incidence of 6-month stroke and its related predictors are unknown. AIMS: To investigate the incidence and to identify procedural and patient-related predictors of 30-day and 6-month stroke after TAVR. METHODS: Data from 2753 consecutive patients with severe aortic stenosis undergoing TAVR were obtained from the OBSERVANT-II study, an observational, prospective, multicenter cohort study. The study endpoints were symptomatic 30-day and 6-month stroke after TAVR. RESULTS: The occurrence of a 30-day and 6-month stroke was low (1.3% and 2.4%, respectively) but with significant impact on survival. Aortic valve predilatation (odds ratio [OR]: 2.28, 95% confidence interval [CI]: 1.12-4.65, p = 0.023), diabetes (OR: 3.10, 95% CI: 1.56-6.18, p = 0.001), and left ventricle ejection fraction < 50% (OR: 2.15, 95% CI: 1.04-4.47, p = 0.04) were independent predictors of 30-day stroke, whereas diabetes (sub-distribution hazard ratio [SHR]: 2.07, 95% CI: 1.25-3.42, p = 0.004), pre-existing neurological dysfunction (SHR: 3.92, 95% CI: 1.54-10, p = 0.004), bicuspid valve (SHR: 4.75, 95% CI: 1.44-15.7, p = 0.011), and critical status (SHR: 3.05, 95% CI: 1.21-7.72, p = 0.018) were predictive of 6-month stroke. Conversely, antiplatelet therapy and anticoagulation were protective factors at both 30 days and 6 months. CONCLUSIONS: Stroke after TAVR was rare. Predilatation was the only procedural factor predictive of 30-day stroke, whereas the remaining were patient-related risk factors, suggesting appropriate risk stratification preoperatively.


Subject(s)
Aortic Valve Stenosis , Diabetes Mellitus , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cohort Studies , Incidence , Prospective Studies , Risk Factors , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Treatment Outcome
4.
Int J Cardiol ; 389: 131236, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37532153

ABSTRACT

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Prosthesis Design , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Registries
5.
Comput Biol Med ; 163: 107147, 2023 09.
Article in English | MEDLINE | ID: mdl-37329622

ABSTRACT

Accurate planning of transcatheter aortic valve implantation (TAVI) is important to minimize complications, and it requires anatomic evaluation of the aortic root (AR), commonly performed through 3D computed tomography (CT) image analysis. Currently, there is no standard automated solution for this process. Two convolutional neural networks with 3D U-Net architectures (model 1 and model 2) were trained on 310 CT scans for AR analysis. Model 1 performs AR segmentation and model 2 identifies the aortic annulus and sinotubular junction (STJ) contours. After training, the two models were integrated into a fully automated pipeline for geometric analysis of the AR. Results were validated against manual measurements of 178 TAVI candidates. The trained CNNs segmented the AR, annulus, and STJ effectively, resulting in mean Dice scores of 0.93 for the AR, and mean surface distances of 0.73 mm and 0.99 mm for the annulus and STJ, respectively. Automatic measurements were in good agreement with manual annotations, yielding annulus diameters that differed by 0.52 [-2.96, 4.00] mm (bias and 95% limits of agreement for manual minus algorithm). Evaluating the area-derived diameter, bias, and limits of agreement were 0.07 [-0.25, 0.39] mm. STJ and sinuses diameters computed by the automatic method yielded differences of 0.16 [-2.03, 2.34] and 0.1 [-2.93, 3.13] mm, respectively. The proposed tool is a fully automatic solution to quantify morphological biomarkers for pre-TAVI planning. The method was validated against manual annotation from clinical experts and showed to be quick and effective in assessing AR anatomy, with potential for time and cost savings.


Subject(s)
Aortic Valve Stenosis , Deep Learning , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aorta, Thoracic , Tomography, X-Ray Computed/methods
6.
Eur Heart J Cardiovasc Imaging ; 24(8): 1052-1061, 2023 07 24.
Article in English | MEDLINE | ID: mdl-36752044

ABSTRACT

AIMS: The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. METHODS AND RESULTS: Patients were categorized according to SVi (<35 mL/m2) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). CONCLUSION: Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Stroke Volume , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Retrospective Studies , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Severity of Illness Index
7.
J Am Heart Assoc ; 11(19): e024589, 2022 10 04.
Article in English | MEDLINE | ID: mdl-36172945

ABSTRACT

Background Acute kidney injury (AKI) after transcatheter aortic valve replacement (TAVR) is associated with increased mortality. However, it is controversial whether AKI affects prognosis per se, being linked to baseline chronic kidney disease (CKD) and bleeding complications. The aim of this study was to disentangle, applying mediation analysis, the association between AKI and clinical outcome, considering CKD and bleedings. Methods and Results Consecutive patients undergoing TAVR were prospectively enrolled at 5 high-volume centers in Italy. AKI was defined according to Valve Academic Research Consortium-3 consensus, whereas bleeding with Bleeding Academic Research Consortium. Primary outcome was all-cause mortality after 1-year follow-up. Among 2621 patients undergoing TAVR, AKI occurrence was associated with 1-year mortality. This association of AKI with the primary end points remained significant after adjusting for baseline risk estimators, either Society of Thoracic Surgeons score (hazard ratio [HR], 2.78 [95% CI, 1.95-3.80], P<0.001) or EuroSCORE-II (HR, 1.85 [95% CI, 1.35-2.56], P<0.001). Both AKI and CKD significantly and independently affected primary outcome (HR, 3.06 [95% CI, 2.01-4.64], P<0.001 and HR, 1.82 [95% CI 1.27-2.65], P<0.01, respectively). The estimated proportion of the total effect of CKD mediated via AKI was, on average, 15%, 95% CI, 4%-29%, P<0.001. The significant effect of Bleeding Academic Research Consortium 2-5 bleedings on the primary outcome was not mediated by AKI. Conclusions AKI occurs in 1 out of 6 patients and significantly mediates one fifth of the effect of baseline CKD on all-cause mortality after TAVR. Our analysis supports a systematic effort to prevent AKI during TAVR, which may potentially translate into improved patients' 1-year survival.


Subject(s)
Acute Kidney Injury , Aortic Valve Stenosis , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Acute Kidney Injury/diagnosis , Acute Kidney Injury/epidemiology , Acute Kidney Injury/etiology , Aortic Valve/surgery , Humans , Prognosis , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/epidemiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
8.
EuroIntervention ; 18(11): e933-e939, 2022 Dec 02.
Article in English | MEDLINE | ID: mdl-35734824

ABSTRACT

Myocardial infarction with non-obstructive coronary arteries (MINOCA) represents about 6-8% of patients presenting with myocardial infarction (MI), and it is associated with a significant risk of mortality, rehospitalisation, and angina burden, with high associated socioeconomic costs. It is important to note that multiple mechanisms may be responsible for MINOCA. However, to date, there are few prospective clinical trials on MINOCA and the treatment of these patients is still not defined, most likely because of the multiple underlying pathogenic mechanisms. The PROMISE trial is a randomised, multicentre, prospective, superiority, phase IV trial that will include 180 MINOCA patients randomised 1:1 to a "precision-medicine approach", consisting of a comprehensive diagnostic workup and pharmacological treatment specific for the underlying cause, versus a "standard of care" approach, consisting of routine diagnostic workup and standard medical treatment for acute coronary syndrome. The aim of this study is to evaluate if the "precision-medicine approach" will improve the angina status, evaluated using the Seattle Angina Questionnaire summary score, at 12 months (primary endpoint). Secondary endpoints include the rate of major adverse cardiovascular events at 12-month follow-up, the related primary and secondary healthcare costs, and the ability of cardiac magnetic resonance to evaluate the different mechanisms of MINOCA. Of importance, the results derived from this trial may pave the way for a new pathophysiology-driven approach with cause-target therapies personalised for the mechanisms of MINOCA (ClinicalTrials.gov: NCT05122780).


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Humans , Coronary Angiography/methods , Prospective Studies , Precision Medicine/adverse effects , MINOCA , Risk Factors , Coronary Vessels/pathology , Coronary Artery Disease/diagnosis
9.
J Cardiovasc Med (Hagerstown) ; 23(7): 454-462, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35763766

ABSTRACT

AIMS: The aim of this study was to minimize the procedure, and reduce the length of hospital stay (LoS) is the future objective for transcatheter aortic valve replacement (TAVI).Aims of the study are to identify procedural and electrocardiographical predictors of fast-track discharge in patients who underwent TAVI. METHODS: Patients treated with TAVI included in the One Hospital ClinicalService project were categorized according to the LoS. 'Fast-Track' population, with a postprocedural LoS less than or equal to 3 days, was compared with the 'Slow-Track' population with a postprocedural LoS greater than 3 days. RESULTS: One thousand five hundred and one patients were collected. Despite single baseline characteristics being almost similar between the two groups, Slow-Track group showed a higher surgical risk (P < 0.001). Patients in the Slow-Track group were more frequently treated with general anaesthesia (P = 0.002) and less frequently predilated (P < 0.001) and received a lower amount of contrast media. No difference between Slow-Track and Fast-Track patients was observed at 30 days in death and in cardiovascular rehospitalization.In the multivariable analysis, STS score of at least 4% [odds ratio (OR): 1.64; P = 0.01], general anaesthesia (OR: 2.80; P = 0.03), predilation (OR: 0.45; P < 001), NYHA 3-4 at baseline (OR: 1.65; P = 0.01), AVB I/LBBB/RBBB onset (OR: 2.41; P < 0.001) and in-hospital new PM (OR: 2.63; P < 0.001) were independently associated with a higher probability of Slow-Track. CONCLUSION: Fast-Track patients were safely discharged home showing no difference in clinical outcomes after discharge up to 30 days compared with the Slow-Track group. The STS score, general anaesthesia, NYHA 3--4 at baseline, in-hospital onset of conduction disturbances and new PM implantation after TAVI turned out to be predictors of Slow-Track.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Electrocardiography , Fluoroscopy , Humans , Patient Discharge , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods
10.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Article in English | MEDLINE | ID: mdl-35595675

ABSTRACT

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Hemodynamics , Humans , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
Cardiovasc Revasc Med ; 35: 19-26, 2022 02.
Article in English | MEDLINE | ID: mdl-33933374

ABSTRACT

PURPOSE: To compare in-hospital outcome of Evolut-R 34 mm vs. smaller Evolut-R devices and to identify predictors of paravalvular leak (PVL) and deep implantation specific for Evolut-R 34 mm. METHODS: This single-center retrospective study included 359 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with Evolut-R 34 mm (N = 84,23.4%) and Evolut-R 23/26/29 mm (N = 275,76.6%) between 2016 and 2019. RESULTS: Patients in Evolut-R 34 mm group were more frequently males, had lower STS score, ejection fraction, and mean aortic gradient compared to the Evolut-R 23/26/29 mm group. Horizontal aorta and large LVOT were more frequent findings in the Evolut-R 34 mm group, whereas calcium volume was comparable among the groups. During TAVR, mean implantation depth and contrast volume were greater in the Evolut-R 34 mm group, compared to the Evolut 23/26/29 mm group. Post-procedurally, 30-day mortality, ≥moderate PVL, device success and pacemaker implantation (PM) rates were comparable between groups. Among independent predictors of ≥moderate PVL, calcium volume (OR:1.04; p < 0.001) was predictive with different thresholds in both groups, whereas aortic angulation (OR:1.40; p = 0.005) was predictive only in Evolut-R 34 mm group at a cutoff of 60° (AUC:0.73; p = 0.043). Body weight (OR:1.03; p = 0.027), left ventricular outflow tract (LVOT) diameter (OR:1.34; p = 0.001), and mean aortic gradient (OR:0.96; p = 0.006) were independent predictors of deep implantation (mean depth ≥ 6 mm), with LVOT>27 mm being predictive specifically for Evolut-R 34 mm (AUC:0.66; p = 0.024). CONCLUSIONS: TAVR with Evolut-R 34 mm and Evolut-R 23/26/29 mm showed comparable in-hospital outcome. Aortic angulation >60° and LVOT >27 mm were predictive respectively of ≥moderate PVL and deep implantation specifically in Evolut-R 34 mm patients.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Hospitals , Humans , Male , Postoperative Complications/surgery , Prosthesis Design , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Article in English | MEDLINE | ID: mdl-34939726

ABSTRACT

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Subject(s)
Heart Failure , Mitral Valve Insufficiency , Ventricular Dysfunction, Right , Heart Ventricles , Humans , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prognosis , Pulmonary Artery/diagnostic imaging , Treatment Outcome , Ventricular Function, Right
14.
Aorta (Stamford) ; 9(6): 201-214, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34963160

ABSTRACT

Over the years, the cardiovascular department of Johannes Gutenberg University in Mainz-West-German Heart Centre in Essen (Germany) designed and implemented the hybrid operating room (2003) along with advanced endovascular and surgical procedures, including the frozen elephant trunk technique. For the study purpose, the Mainz-Essen experience on acute aortic syndromes was summarized by considering original articles from single-center or multicenter studies performed at West German Heart Centre, Essen, Germany, or at the cardiovascular department of Johannes Gutenberg University, Mainz, Germany. We present the 35-year-long Mainz-Essen research, education, and patient management journey in creating an integrated multidisciplinary "Aortic Center" in the heart of Europe.

15.
Aorta (Stamford) ; 9(4): 127-138, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34749408

ABSTRACT

Acute aortic syndromes (AAS) encompass a group of life-threatening medical conditions (acute aortic dissection [AAD], intramural hematoma, and penetrating aortic ulcer) with a common pathophysiological pathway. Due to overlapping symptoms and signs with other cardiovascular emergencies, the diagnosis remains challenging resulting in time delays and related increased in-hospital and long-term morbidity and mortality. The Cardiovascular Department of Johannes Gutenberg University in Mainz at West-German Heart Centre in Essen (Germany) first described (in 1984) AAD by transesophageal echocardiography, AAD diagnostic features, and furtherly explored the implementation of "invasive" imaging techniques, namely, intravascular ultrasound and intraluminal phased-array imaging. Furthermore, pioneer studies were undertaken on the biomarker and imaging interplay, namely, D-dimer and F-fluorodeoxyglucose positron emission tomography/computed tomography. We discuss the unique 35-year-long Mainz-Essen experience on the diagnostic and prognostic role of serological and imaging biomarkers in AAS.

16.
J Mech Behav Biomed Mater ; 123: 104772, 2021 11.
Article in English | MEDLINE | ID: mdl-34481297

ABSTRACT

Computational simulations of Transcatheter Aortic Valve Implantation (TAVI) have reached a high level of complexity and accuracy for the prediction of possible implantation scenarios during the decision-making process. However, when focusing on the prosthetic device, currently different devices are available on the market which not only have different geometries, but also different material properties. The present work focuses on the calibration of Nitinol constitutive parameters of four self-expandable devices starting from experimental radial force tests on the prosthetic samples. Beside providing optimal material properties for each specific device, we also perform a patient-specific simulation, comparing the results obtained using both "literature" and calibrated parameters with the aim of investigating the impact of metallic frame parameters choice on simulation results.


Subject(s)
Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve , Computer Simulation , Finite Element Analysis , Humans , Mechanical Phenomena , Prosthesis Design , Treatment Outcome
18.
Med Eng Phys ; 89: 42-50, 2021 03.
Article in English | MEDLINE | ID: mdl-33608124

ABSTRACT

OBJECTIVE: Transcatheter Aortic Valve Implantation (TAVI) is a consolidated procedure showing a low operative risk and excellent long-term outcomes in patients with aortic stenosis. Patients presenting a bicuspid aortic valve (BAV) often require valve replacement due to the highly calcific nature of the aortic leaflets. However, BAV patients have usually been contraindicated for TAVI due to their complex valve anatomy. The aim of this work was to compare the performance of devices featuring high conformability (HC) against those with high radial force (HRF). METHODS: Four BAV patients undergoing TAVI were retrospectively selected. The aortic roots including the native leaflets and calcifications were reconstructed from pre-operative Computed Tomography scans. In each patient, both HC and HRF devices were virtually implanted using Finite Element Analysis simulations. After implantation, paravalvular orifice area, von Mises stress distribution, root contact area, and device eccentricity were calculated. RESULTS: Simulations showed good agreement with intraoperative imaging. In 3 out of 4 patients, the HRF device resulted in a lower paravalvular area than the HC. Stress distribution was also more homogeneously distributed in the HRF group as compared with the HC group. Despite their lower adaptability, HRF devices showed consistently higher stent-root contact area. CONCLUSION: HRF devices showed improved results with respect to HC valves after being deployed in BAV anatomies. We hypothesize that the ability to reshape the annulus is the major determinant of success in this subgroup of patients featuring highly calcified leaflets.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Humans , Retrospective Studies , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 97(1): E135-E145, 2021 01 01.
Article in English | MEDLINE | ID: mdl-32400068

ABSTRACT

OBJECTIVES: To investigate paravalvular leak (PVL) and devices success rates according to aortic angle (AA) in patients undergoing transcatheter aortic valve implantation (TAVI) with three new-generation self-expanding devices. BACKGROUND: The impact of aortic angle (AA) on TAVI device success and PVL rates is controversial. METHODS: This retrospective study included 392 patients submitted to TAVI for severe aortic stenosis with Portico, Evolut-R and Acurate-NEO, and available AA measurements at computed tomography (CT) angiography. AA was calculated from the implantation projection and was defined as the angle between the plane of aortic annulus and an ideal horizontal plane. Aorta was defined horizontal if AA>57° (75th percentile). RESULTS: In the horizontal group, the rates of moderate/severe PVL was higher in the Evolut-R group (20.8%), which was also characterized by a lower implant compared to that of Acurate-NEO, whereas device success was comparable among the three devices. AA was a significant predictor of moderate/severe PVLs (AUC 0.72, p = .002) only in the Evolut-R population. On multivariate analysis, calcium volume 850HU, bicuspid aortic valve, and implantation depth at the level of left coronary cusp were independent predictors of moderate/severe PVL. On univariate analysis in the horizontal aorta population, implantation depth was confirmed among the most significant predictors of moderate/severe PVL. CONCLUSIONS: Despite comparable device success rates, horizontal aorta represented a technical challenge only in the Evolut-R subgroup, which showed higher rates of moderate/severe PVL than Portico and Acurate-NEO, and was associated with a low implant.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aorta , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Postoperative Complications , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
20.
Interact Cardiovasc Thorac Surg ; 32(1): 20-28, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33201993

ABSTRACT

OBJECTIVES: To compare device success and paravalvular leak rates of 3 new-generation transcatheter aortic valve replacement devices in patients with bicuspid aortic valve stenosis and to test their biomechanical performance in a computer-based simulation model of aortic root with increasing ellipticity. METHODS: This retrospective multicentre study included 56 bicuspid aortic valve patients undergoing transcatheter aortic valve replacement with new-generation devices: Lotus/Lotus Edge (N = 15; 27%), Evolut-R (N = 20; 36%) and ACURATE neo (N = 21; 37%). Three virtual simulation models of aortic root with increasing index of eccentricity (0-0.25-0.5) were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed. RESULTS: Device success was achieved in 43/56 patients (77%) with comparable rates among Lotus (87%), Evolut-R (60%) and ACURATE neo (86%; P = 0.085). Moderate paravalvular leak rate was significantly lower in the Lotus group as compared to Evolut-R group (0% vs 30%; P = 0.027) and comparable to the ACURATE neo group (0% vs 10%; P = 0.33). By index of eccentricity = 0.5, Lotus showed a uniform and symmetric pattern of stress distribution with absent paravalvular orifice area, ACURATE neo showed a mild asymmetry with small paravalvular orifice area (1.1 mm2), whereas a severely asymmetric pattern was evident with Evolut-R, resulting in a large paravalvular orifice area (12.0 mm2). CONCLUSIONS: Transcatheter aortic valve replacement in bicuspid aortic valve patients with new-generation devices showed comparable device success rates. Lotus showed moderate paravalvular leak rate comparable to that of ACURATE neo and significantly lower than Evolut-R. On simulation, Lotus and ACURATE neo showed optimal adaptability to elliptic anatomies as compared to Evolut-R.


Subject(s)
Bicuspid Aortic Valve Disease/surgery , Constriction, Pathologic/surgery , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aorta/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Humans , Male , Retrospective Studies , Stents , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...