Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
J Chromatogr A ; 1371: 204-19, 2014 Dec 05.
Article in English | MEDLINE | ID: mdl-25456599

ABSTRACT

In hydrophobic interaction chromatography (HIC), interactions between buried hydrophobic residues and HIC surfaces can cause conformational changes that interfere with separations and cause yield losses. This paper extends our previous investigations of protein unfolding in HIC chromatography by identifying protein structures on HIC surfaces under denaturing conditions and relating them to solution behavior. The thermal unfolding of three model multidomain proteins on three HIC surfaces of differing hydrophobicities was investigated with hydrogen exchange mass spectrometry (HXMS). The data were analyzed to obtain unfolding rates and Gibbs free energies for unfolding of adsorbed proteins. The melting temperatures of the proteins were lowered, but by different amounts, on the different surfaces. In addition, the structures of the proteins on the chromatographic surfaces were similar to the partially unfolded structures produced in the absence of a surface by temperature as well as by chemical denaturants. Finally, it was found that patterns of residue exposure to solvent on different surfaces at different temperatures can be largely superimposed. These findings suggest that protein unfolding on various HIC surfaces might be quantitatively related to protein unfolding in solution and that details of surface unfolding behavior might be generalized.


Subject(s)
Hydrophobic and Hydrophilic Interactions , Mass Spectrometry/methods , Proteins/chemistry , Adsorption , Animals , Cattle , Humans , Models, Molecular , Protein Structure, Tertiary , Protein Unfolding , Solvents , Surface Properties
2.
J Chromatogr A ; 1355: 238-52, 2014 Aug 15.
Article in English | MEDLINE | ID: mdl-24997510

ABSTRACT

Recent studies with proteins indicate that conformational changes and aggregation can occur during ion exchange chromatography (IEC). Such behavior is not usually expected, but could lead to decreased yield and product degradation from both IEC and multi mode chromatography (MMC) that has ligands of both hydrophobic and charged functionalities. In this study, we used hydrogen exchange mass spectrometry to investigate unfolding of the model protein BSA on IEC and MMC surfaces under different solution conditions at 25°C. Increased solvent exposure, indicating greater unfolding relative to that in solution, was found for protein adsorbed on cationic IEC and MMC surfaces in the pH range of 3.0 to 4.5, where BSA has decreased stability in solution. There was no effect of anionic surfaces at pH values in the range from 6.0 to 9.0. Differences of solvent exposure of whole molecules when adsorbed and in solution suggest that adsorbed BSA unfolds at lower pH values and may show aggregation, depending upon pH and the surface type. Measurements on digested peptides showed that classifications of stability can be made for various regions; these are generally retained as pH is changed. When salt was added to MMC systems, where electrostatic interactions would be minimized, less solvent exposure was seen, implying that it is the cationic moieties, rather than the hydrophobic ligands, which cause greater surface unfolding at low salt concentrations. These results suggest that proteins of lower stability may exhibit unfolding and aggregation during IEC and MMC separations, as they can with hydrophobic interaction chromatography.


Subject(s)
Chromatography, Ion Exchange/methods , Protein Unfolding , Serum Albumin, Bovine/analysis , Animals , Cattle , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Models, Molecular , Protein Structure, Tertiary , Serum Albumin, Bovine/chemistry , Serum Albumin, Bovine/metabolism , Surface Properties
3.
Langmuir ; 27(1): 286-95, 2011 Jan 04.
Article in English | MEDLINE | ID: mdl-21117672

ABSTRACT

Hydrogen exchange mass spectrometry (HXMS) coupled to proteolytic digestion has been used to probe the conformation of bovine ß-lactoglobulin (BLG), bovine α-lactalbumin (BLA), and human serum albumin (HSA) in solution and while adsorbed to the hydrophobic interaction chromatography media Phenyl Sepharose 6FF. All three proteins show evidence of EX1 exchange kinetics, indicating a loss of stability on the surface. HX protection patterns for all three proteins also indicate that the unfolded form is only partially solvent exposed. The hydrogen-deuterium exchange patterns of BLG and BLA on the surface suggest a structure that resembles each protein's respective solution phase molten globule state. The low stability of Domain II of HSA observed on Phenyl Sepharose 6FF also suggests a link to solution stability because Domain II is frequently cited as the least stable domain in solution unfolding pathways. COREX, an algorithm used to compute protein folding stabilities, correctly predicts solution hydrogen-deuterium exchange patterns for BLG and offers insight into its adsorbed phase stabilities but is unreliable for BLA predictions. The results of this work demonstrate a link between solution-phase local stability patterns and the nature of partially unfolded states that proteins can adopt on HIC surfaces.


Subject(s)
Algorithms , Chromatography/methods , Deuterium Exchange Measurement/methods , Hydrophobic and Hydrophilic Interactions , Proteins/chemistry , Adsorption , Amino Acid Sequence , Animals , Cattle , Humans , Lactalbumin/chemistry , Lactoglobulins/chemistry , Mass Spectrometry , Molecular Sequence Data , Protein Stability , Serum Albumin/chemistry , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL