Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Am Coll Cardiol ; 79(7): 651-661, 2022 02 22.
Article in English | MEDLINE | ID: mdl-35177194

ABSTRACT

BACKGROUND: Detection of ≥50% diameter stenosis left main coronary artery disease (LMD) has prognostic and therapeutic implications. Noninvasive stress imaging or an exercise tolerance test (ETT) are the most common methods to detect obstructive coronary artery disease, though stress test markers of LMD remain ill-defined. OBJECTIVES: The authors sought to identify markers of LMD as detected on coronary computed tomography angiography (CTA), using clinical and stress testing parameters. METHODS: This was a post hoc analysis of ISCHEMIA (International Study of Comparative Health Effectiveness With Medical and Invasive Approaches), including randomized and nonrandomized participants who had locally determined moderate or severe ischemia on nonimaging ETT, stress nuclear myocardial perfusion imaging, or stress echocardiography followed by CTA to exclude LMD. Stress tests were read by core laboratories. Prior coronary artery bypass grafting was an exclusion. In a stepped multivariate model, the authors identified predictors of LMD, first without and then with stress testing parameters. RESULTS: Among 5,146 participants (mean age 63 years, 74% male), 414 (8%) had LMD. Predictors of LMD were older age (P < 0.001), male sex (P < 0.01), absence of prior myocardial infarction (P < 0.009), transient ischemic dilation of the left ventricle on stress echocardiography (P = 0.05), magnitude of ST-segment depression on ETT (P = 0.004), and peak metabolic equivalents achieved on ETT (P = 0.001). The models were weakly predictive of LMD (C-index 0.643 and 0.684). CONCLUSIONS: In patients with moderate or severe ischemia, clinical and stress testing parameters were weakly predictive of LMD on CTA. For most patients with moderate or severe ischemia, anatomical imaging is needed to rule out LMD. (International Study of Comparative Health Effectiveness With Medical and Invasive Approaches [ISCHEMIA]; NCT01471522).


Subject(s)
Computed Tomography Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/metabolism , Internationality , Single Photon Emission Computed Tomography Computed Tomography/methods , Aged , Cohort Studies , Coronary Vessels/diagnostic imaging , Coronary Vessels/metabolism , Female , Humans , Male , Middle Aged , Myocardial Perfusion Imaging/methods , Positron-Emission Tomography/methods , Predictive Value of Tests
2.
JACC Cardiovasc Interv ; 15(1): 93-104, 2022 01 10.
Article in English | MEDLINE | ID: mdl-34991828

ABSTRACT

OBJECTIVES: This study sought to evaluate the 30-day and 1-year safety and performance of the Hydra transcatheter aortic valve (THV) (in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk. BACKGROUND: The Hydra THV is a novel repositionable self-expanding system with supra-annular bovine pericardial leaflets. METHODS: The Hydra CE study was a premarket, prospective, multicenter, single-arm study conducted across 18 study centers in Europe and Asia-Pacific countries. The primary endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee. RESULTS: A total of 157 patients (79.2 ± 7.1 years of age, 58.6% female; Society of Thoracic Surgeons score 4.7 ± 3.4%) were enrolled. Successful implantation was achieved in 94.3% cases. At 30 days, there were 11 (7.0%) deaths, including 9 (5.7%) cardiovascular deaths, of which 5 (3.2%) were device related. At 1 year, there were 23 (14.6%) deaths, including 13 (8.3%) cardiovascular deaths. At 30 days, there were significant improvement of effective orifice area (from 0.7 ± 0.2 cm2 to 1.9 ± 0.6 cm2) and mean aortic valve gradient (from 49.5 ± 18.5 mm Hg to 8.1 ± 3.7 mm Hg), which were sustained up to 1 year. Moderate or severe paravalvular leak was observed in 6.3% of patients at 30 days and 6.9% of patients at 1 year. The rate of new permanent pacemaker implantation was 11.7% at 30 days and 12.4% at 1 year. CONCLUSIONS: The Hydra CE study demonstrated that transcatheter aortic valve replacement with Hydra THV offered favorable efficacy at 1 year, providing large effective orifice area and low transvalvular gradient as well as acceptable complication rates with regard to new permanent pacemaker and paravalvular leak. (A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve; NCT02434263).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Animals , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cattle , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 98(2): 371-379, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33876881

ABSTRACT

OBJECTIVES: To evaluate the safety and performance of the Hydra transcatheter aortic valve (THV) in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk. BACKGROUND: The Hydra THV (Vascular Innovations Co. Ltd., Nonthaburi, Thailand) is a novel flexible repositionable self-expanding system with supra-annular bovine pericardial leaflets, available in three sizes, covering aortic annuli between 17 and 27 mm. METHODS: The GENESIS trial was a prospective, multi-center, single-arm, 6 month follow-up study conducted in India. The primary performance endpoint was device success defined as per VARC-II criteria at 30 days. The primary safety endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee. RESULTS: Forty high-risk patients (74.5 ± 6.7 years, 60% men; STS Score:5.6 ± 4.2%) were enrolled in 11 centres. Device success was achieved in 92.5%. The effective orifice area improved from 0.7 ± 0.2 to 2.3 ± 0.6 cm2 at 30 days and to 2.2 ± 0.7 cm2 at 6 months (p < .0001). Mean aortic valve gradient decreased from 53.5 ± 18.1 to 8.9 ± 4.9 mmHg at 30 days and to 7.6 ± 2.7 mmHg at 6 months (p < .0001). The rate of new permanent pacemaker implantation was 7.5% at 30 days, and no patient had more than mild paravalvular leak at 6 months. The 30 days and 6 month all-cause mortality was 10.0 and 17.5%, cardiovascular mortality 7.5 and 7.5%, device-related mortality 5.0 and 5.0%, respectively. No patients had stroke up to 6 months. CONCLUSIONS: The GENESIS trial demonstrated high efficacy of the self-expanding Hydra THV. The cardiovascular mortality rate of 7.5% may partly be explained by the inclusion of some centres with no or limited previous experience in transcatheter aortic valve implantation.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Hydra , Transcatheter Aortic Valve Replacement , Animals , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cattle , Female , Follow-Up Studies , Humans , Male , Prospective Studies , Prosthesis Design , Risk Factors , Thailand , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
4.
Circ Cardiovasc Qual Outcomes ; 12(11): e006002, 2019 11.
Article in English | MEDLINE | ID: mdl-31718297

ABSTRACT

BACKGROUND: Risk factor control is the cornerstone of managing stable ischemic heart disease but is often not achieved. Predictors of risk factor control in a randomized clinical trial have not been described. METHODS AND RESULTS: The ISCHEMIA trial (International Study of Comparative Health Effectiveness with Medical and Invasive Approaches) randomized individuals with at least moderate inducible ischemia and obstructive coronary artery disease to an initial invasive or conservative strategy in addition to optimal medical therapy. The primary aim of this analysis was to determine predictors of meeting trial goals for LDL-C (low-density lipoprotein cholesterol, goal <70 mg/dL) or systolic blood pressure (SBP, goal <140 mm Hg) at 1 year post-randomization. We included all randomized participants in the ISCHEMIA trial with baseline and 1-year LDL-C and SBP values by January 28, 2019. Among the 3984 ISCHEMIA participants (78% of 5179 randomized) with available data, 35% were at goal for LDL-C, and 65% were at goal for SBP at baseline. At 1 year, the percent at goal increased to 52% for LDL-C and 75% for SBP. Adjusted odds of 1-year LDL-C goal attainment were greater with older age (odds ratio [OR], 1.11 [95% CI, 1.03-1.20] per 10 years), lower baseline LDL-C (OR, 1.19 [95% CI, 1.17-1.22] per 10 mg/dL), high-intensity statin use (OR, 1.30 [95% CI, 1.12-1.51]), nonwhite race (OR, 1.32 [95% CI, 1.07-1.63]), and North American enrollment compared with other regions (OR, 1.32 [95% CI, 1.06-1.66]). Women were less likely than men to achieve 1-year LDL-C goal (OR, 0.68 [95% CI, 0.58-0.80]). Adjusted odds of 1-year SBP goal attainment were greater with lower baseline SBP (OR, 1.27 [95% CI, 1.22-1.33] per 10 mm Hg) and with North American enrollment (OR, 1.35 [95% CI, 1.04-1.76]). CONCLUSIONS: In ISCHEMIA, older age, male sex, high-intensity statin use, lower baseline LDL-C, and North American location predicted 1-year LDL-C goal attainment, whereas lower baseline SBP and North American location predicted 1-year SBP goal attainment. Future studies should examine the effects of sex disparities, international practice patterns, and provider behavior on risk factor control.


Subject(s)
Antihypertensive Agents/therapeutic use , Blood Pressure/drug effects , Cholesterol, LDL/blood , Coronary Artery Disease/drug therapy , Dyslipidemias/drug therapy , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Hypertension/drug therapy , Age Factors , Aged , Antihypertensive Agents/adverse effects , Biomarkers/blood , Clinical Protocols , Coronary Artery Disease/blood , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Dyslipidemias/blood , Dyslipidemias/mortality , Female , Health Status Disparities , Healthcare Disparities , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/adverse effects , Hypertension/mortality , Hypertension/physiopathology , Male , Middle Aged , Randomized Controlled Trials as Topic , Risk Factors , Sex Factors , Time Factors
5.
Cardiol Young ; 28(1): 147-149, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28835313

ABSTRACT

Kawasaki disease is a febrile vasculitis affecting young children, which may lead to coronary aneurysms. Echocardiography, although sensitive in detecting coronary aneurysms, has a limited role in diagnosing coronary thrombus. Here we report the case of a 10-year-old boy who presented with typical features of Kawasaki disease with giant coronary aneurysms. His follow-up echocardiogram revealed coronary arterial thrombus.


Subject(s)
Coronary Aneurysm/diagnostic imaging , Mucocutaneous Lymph Node Syndrome/complications , Mucocutaneous Lymph Node Syndrome/diagnosis , Thrombosis/diagnostic imaging , Child , Coronary Angiography , Coronary Vessels/diagnostic imaging , Echocardiography , Fever/etiology , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...