ABSTRACT
PURPOSE: To demonstrate the feasibility of Robotically Assisted Sonic Therapy (RAST)-a noninvasive and nonthermal focused ultrasound therapy based on histotripsy-for renal ablation in a live porcine model. MATERIALS AND METHODS: RAST ablations (n = 11) were performed in 7 female swine: 3 evaluated at 1 week (acute) and 4 evaluated at 4 weeks (chronic). Treatment groups were acute bilateral (3 swine, 6 ablations with immediate computed tomography [CT] and sacrifice); chronic single kidney (3 swine, 3 ablations; CT at day 0, week 1, and week 4 after treatment, followed by sacrifice); and chronic bilateral (1 swine, 2 ablations). Treatments were performed using a prototype system (VortxRx; HistoSonics, Inc) and targeted a 2.5-cm-diameter sphere in the lower pole of each kidney, intentionally including the central collecting system. RESULTS: Mean treatment time was 26.4 minutes. Ablations had a mean diameter of 2.4 ± 0.3 cm, volume of 8.5 ± 2.4 cm3, and sphericity index of 1.00. Median ablation volume decreased by 96.1% over 4 weeks. Histology demonstrated complete lysis with residual blood products inside the ablation zone. Temporary collecting system obstruction by thrombus was observed in 4/11 kidneys (2 acute and 2 chronic) and resolved by 1 week. There were no urinary leaks, main vessel thromboses, or adjacent organ injuries on imaging or necropsy. CONCLUSIONS: In this normal porcine model, renal RAST demonstrated complete histologic destruction of the target renal tissue while sparing the urothelium.
Subject(s)
High-Intensity Focused Ultrasound Ablation , Kidney/surgery , Robotic Surgical Procedures , Animals , Feasibility Studies , High-Intensity Focused Ultrasound Ablation/adverse effects , Kidney/diagnostic imaging , Kidney/pathology , Models, Animal , Multidetector Computed Tomography , Operative Time , Robotic Surgical Procedures/adverse effects , Sus scrofa , Time FactorsABSTRACT
PURPOSE: To quantify the effect of transarterial embolization on microwave (MW) ablations in an in vivo porcine liver model. MATERIALS AND METHODS: Hepatic arteriography and cone-beam computed tomography (CT) scans were performed in 6 female domestic swine. Two lobes were embolized to an endpoint of substasis with 100-300-µm microspheres. MW ablations (65 W, 5 min) were created in embolized (n = 15) and nonembolized (n = 12) liver by using a 2.45-GHz system and single antenna. Cone-beam CT scans were obtained to monitor the ablations, document gas formation, and characterize arterial flow. Ablation zones were excised and sectioned. A mixed-effects model was used to compare ablation zone diameter, length, area, and circularity. RESULTS: Combined transarterial embolization and MW ablation zones had significantly greater area (mean ± standard deviation, 11.8 cm2 ± 2.5), length (4.8 cm ± 0.5), and diameter (3.1 cm ± 0.6) compared with MW only (7.1 cm2 ± 1.9, 3.7 cm ± 0.6, and 2.4 cm ± 0.3, respectively; P = .0085, P = .0077, and P = .0267, respectively). Ablation zone circularity was similar between groups (P = .9291). The larger size of the combined ablation zones was predominantly the result of an increase in size of the peripheral noncharred zone of coagulation (1.3 cm ± 0.4 vs 0.8 cm ± 0.2; P = .0104). Cone-beam CT scans demonstrated greater gas formation during combined ablations (1.8 cm vs 1.1 cm, respectively). Mean maximum temperatures 1 cm from the MW antennas were 86.6°C and 68.7°C for the combined embolization/ablation and MW-only groups, respectively. CONCLUSIONS: Combining transarterial embolization and MW ablation increased ablation zone diameter and area by approximately 27% and 66%, respectively, in an in vivo non-tumor-bearing porcine liver model. This is largely the result of an increase in the size of the peripheral ablation zone, which is most susceptible to local blood flow.