Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
J Extracell Vesicles ; 8(1): 1596016, 2019.
Article in English | MEDLINE | ID: mdl-30988894

ABSTRACT

The expanding field of extracellular vesicle (EV) research needs reproducible and accurate methods to characterize single EVs. Nanoparticle Tracking Analysis (NTA) is commonly used to determine EV concentration and diameter. As the EV field is lacking methods to easily confirm and validate NTA data, questioning the reliability of measurements remains highly important. In this regard, a comparison addressing measurement quality between different NTA devices such as Malvern's NanoSight NS300 or Particle Metrix' ZetaView has not yet been conducted. To evaluate the accuracy and repeatability of size and concentration determinations of both devices, we employed comparative methods including transmission electron microscopy (TEM) and single particle interferometric reflectance imaging sensing (SP-IRIS) by ExoView. Multiple test measurements with nanospheres, liposomes and ultracentrifuged EVs from human serum and cell culture supernatant were performed. Additionally, serial dilutions and freeze-thaw cycle-dependent EV decrease were measured to determine the robustness of each system. Strikingly, NanoSight NS300 exhibited a 2.0-2.1-fold overestimation of polystyrene and silica nanosphere concentration. By measuring serial dilutions of EV samples, we demonstrated higher accuracy in concentration determination by ZetaView (% BIAS range: 2.7-8.5) in comparison with NanoSight NS300 (% BIAS range: 32.9-36.8). The concentration measurements by ZetaView were also more precise (% CV range: 0.0-4.7) than measurements by NanoSight NS300 (% CV range: 5.4-10.7). On the contrary, quantitative TEM imaging indicated more accurate EV sizing by NanoSight NS300 (% DTEM range: 79.5-134.3) compared to ZetaView (% DTEM range: 111.8-205.7), while being equally repeatable (NanoSight NS300% CV range: 0.8-6.7; ZetaView: 1.4-7.8). However, both devices failed to report a peak EV diameter below 60 nm compared to TEM and SP-IRIS. Taken together, NTA devices differ strongly in their hardware and software affecting measuring results. ZetaView provided a more accurate and repeatable depiction of EV concentration, whereas NanoSight NS300 supplied size measurements of higher resolution.

2.
Nephrology (Carlton) ; 24(11): 1179-1188, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30891898

ABSTRACT

AIM: Focal segmental glomerulosclerosis recurs in up to 30% and up to 80% of adult and pediatric kidney transplant recipients, respectively. There is no standard of care treatment. The purpose of this study was to evaluate clinical characteristics, treatments and outcomes of patients with focal segmental glomerulosclerosis recurrence (FSGSr). METHODS: This was a retrospective single-center cohort study including FSGSr patients treated with plasmapheresis (PP) and combinations of high dose steroids, cyclosporine and rituximab. RESULTS: Among 61 patients included in this analysis the median time to diagnosis was 19 days. The incidence of first biopsy-confirmed FSGSr was 18% reaching 52.4% with follow-up biopsies. During PP treatment 54% of the patients developed infectious complications. PP was discontinued in 37% of patients due to treatment failure (no remission or graft loss) and in 26% due to an adverse event. All patients who discontinued PP due to adverse event did not show clinical response or lost the allograft. The incidence of acute rejection was 34.4%. The incidences of partial and complete remissions were 16.4% and 27.8%, respectively. Overall 6-years patient and graft survivals were 90.7% and 64.5%, respectively. CONCLUSION: This analysis confirms the low, variable and unpredictable rate of FSGSr remission, inconsistencies among available therapeutic options and its high rate of adverse events, and the negative impact on graft survival.


Subject(s)
Glomerulosclerosis, Focal Segmental/epidemiology , Kidney Transplantation , Adolescent , Adult , Child , Female , Glomerulosclerosis, Focal Segmental/therapy , Graft Rejection/epidemiology , Graft Survival , Humans , Kidney Transplantation/adverse effects , Male , Middle Aged , Plasmapheresis/adverse effects , Recurrence , Retrospective Studies , Young Adult
3.
Oncotarget ; 7(21): 30523-35, 2016 May 24.
Article in English | MEDLINE | ID: mdl-27105521

ABSTRACT

The goal of targeted immunotherapy in cancer is to damage both malignant and tumor-supporting cells of the microenvironment but spare unaffected tissue. The malignant cells in classical Hodgkin lymphoma (cHL) selectively express CD30. They release this receptor on extracellular vesicles (EVs) for the tumor-supporting communication with CD30 ligand (CD30L)-positive bystander cells. Here, we investigated how CD30-positive EVs influence the efficacy of the CD30 antibody drug conjugate (ADC) Brentuximab Vedotin (SGN-35). The malignant cells and the EVs expressed the active sheddase ADAM10. ADAM10 cleaved and released the CD30 ectodomain (sCD30), causing a gradual depletion of SGN-35 binding sites on EVs and creating a soluble competitor of the ADC therapy. In a 3D semi-solid tumor microenvironment model, the EVs were retained in the matrix whereas sCD30 penetrated readily into the surrounding culture medium. This resulted in a lowered ratio of EV-associated CD30 (CD30EV) to sCD30 in the surrounding medium in comparison to non-embedded cultures. A low percentage of CD30EV was also detected in the plasma of cHL patients, supporting the clinical relevance of the model. The adherence of CD30EV but not sCD30 to CD30-/CD30L+ mast cells and eosinophils allowed the indirect binding of SGN-35. Moreover, SGN-35 damaged CD30-negative cells, provided they were loaded with CD30+ EVs.


Subject(s)
Bystander Effect/drug effects , CD30 Ligand/metabolism , Extracellular Vesicles/metabolism , Immunoconjugates/pharmacology , Ki-1 Antigen/metabolism , ADAM10 Protein/metabolism , Blotting, Western , Brentuximab Vedotin , Cell Communication/drug effects , Cell Line, Tumor , Hodgkin Disease/metabolism , Hodgkin Disease/pathology , Humans , Tumor Microenvironment/drug effects
4.
Transpl Immunol ; 32(2): 61-5, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25698648

ABSTRACT

Several studies have shown association of high pre- or post-transplant levels of soluble CD30 (sCD30) with acute rejection and poor late kidney transplant outcome. Our goal was to investigate whether sCD30 levels at month-3 post-transplant are associated with subclinical rejection, presence of CD30(+) cells within the graft, and expression of immune response genes in peripheral blood mononuclear cells. The study comprised 118 adult first kidney graft recipients, transplanted at a single center, receiving tacrolimus in low concentration. All were submitted to a protocol biopsy at month-3. Subclinical rejection was identified in 10 biopsies and sCD30 levels ≥ 61.88 ng/mL (P = 0.004), younger recipient age (P = 0.030) and non-Caucasian ethnicity (P = 0.011) were independently associated with this outcome. Rare CD30(+) cells were present in only two biopsies. There was a correlation between sCD30 levels and CD30 gene expression in peripheral blood mononuclear cells (r = 0.385, P = 0.043). These results show that high sCD30 levels are independent predictors of graft dysfunction and may contribute to patient selection protocols by indicating those who could benefit from a more thorough evaluation.


Subject(s)
Gene Expression Regulation , Graft Rejection/blood , Ki-1 Antigen/blood , Kidney Transplantation , Leukocytes, Mononuclear/metabolism , Adult , Age Factors , Aged , Female , Graft Rejection/immunology , Graft Rejection/pathology , Humans , Ki-1 Antigen/immunology , Leukocytes, Mononuclear/immunology , Leukocytes, Mononuclear/pathology , Male , Middle Aged , Postoperative Period , Time Factors
5.
Transpl Immunol ; 29(1-4): 34-8, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23928467

ABSTRACT

The purpose of this study was to evaluate the association of post-transplant soluble CD30 (sCD30) levels, isolated or in combination with of anti-HLA class II antibodies and of serum creatinine levels, with kidney graft loss due to chronic allograft nephropathy (CAN), and type of lesions in graft biopsies for cause. The study comprised 511 first kidney graft recipients, transplanted at a single center, with a graft functioning for at least 2.8 years. A single blood sample was collected from each patient. sCD30 levels were determined by ELISA, and HLA antibodies by Luminex assay. The minimum follow-up after testing was 9.3 years. High sCD30 levels, set at sCD30 ≥ 34.15 ng/mL, the presence of HLA class II antibodies, and serum creatinine ≥ 1.9 mg/dL were independently associated with CAN-graft loss (P values <0.0001, 0.05, <0.0001, respectively), and the combined hazard ratio for CAN-graft loss was 20.2. Analyses of 166 biopsies for cause showed that high sCD30 levels and creatinine were independently associated with interstitial lesions. Post-transplant sCD30 serum levels, especially in conjunction with information regarding HLA class II antibodies and serum creatinine levels, provide valuable information regarding graft outcome and could be useful for the management of kidney transplant recipients.


Subject(s)
Graft Rejection/blood , Isoantibodies/blood , Ki-1 Antigen/blood , Kidney Diseases/blood , Kidney Transplantation , Adolescent , Adult , Aged , Child , Child, Preschool , Creatinine/blood , Creatinine/immunology , Female , Follow-Up Studies , Graft Rejection/immunology , Histocompatibility Antigens Class II/immunology , Histocompatibility Antigens Class II/metabolism , Humans , Isoantibodies/immunology , Ki-1 Antigen/immunology , Kidney Diseases/etiology , Kidney Diseases/immunology , Kidney Diseases/prevention & control , Male , Middle Aged , Retrospective Studies
6.
Hum Immunol ; 74(10): 1300-3, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23831256

ABSTRACT

False-positive anti-HLA reactions may occur in Luminex-single antigen (SA) beads assays, and it is important to recognize them to correctly interpret the test. The purpose of this report is to describe a peculiar pattern of reactivity, characterized by positivity with beads coated with HLA-DRB1*09:01, DRB3*01:01, DRB3*02:02, DRB3*03:01, DPB1*02:01, DPB1*20:01 and DPB1*28:01, that was observed in 141 of 8121 serum samples tested in our laboratory with three different lots of the same kit (LABScreen(®) SA, One Lambda). These 141 serum samples came from 56 different patients on the kidney transplant waiting list, corresponding to 1% of the patients. Of these, 10 males had never been transfused or transplanted. About 66% of the patients had positive reactions against self-antigen HLA-DRB3 alleles. No reactions against native HLA-DRB1*09:01 were observed in flow cytometry crossmatch and in absorption/elution experiments, leading to the conclusion that the reactivity was due to antibodies against epitopes present in denatured forms of HLA-class II antigens. The occurrence of this reactivity pattern was associated with female gender and systemic lupus erythematosus (SLE).


Subject(s)
Antibodies/immunology , Histocompatibility Antigens Class II/immunology , Immunoassay , Antibodies/blood , Case-Control Studies , Female , Flow Cytometry , Gene Frequency , Histocompatibility Antigens Class II/chemistry , Histocompatibility Antigens Class II/genetics , Histocompatibility Testing , Humans , Immunoassay/methods , Kidney Transplantation , Male , Protein Denaturation , Reagent Kits, Diagnostic
7.
Transplantation ; 94(6): 589-95, 2012 Sep 27.
Article in English | MEDLINE | ID: mdl-22892989

ABSTRACT

BACKGROUND: The participation of Toll-like receptor (TLR) 4, an innate immunity receptor, has been previously demonstrated in the pathogenesis of acute renal injury. We aimed to investigate whether messenger RNA (mRNA) levels of TLR4 and its adapter molecule, myeloid differentiation primary response gene (MYD) 88, are associated with delayed graft function (DGF) and could be used as biomarkers of its occurrence. METHODS: TLR4 and MYD88 gene mRNA levels were evaluated with real-time polymerase chain reaction, in preimplantation biopsies (n=89) and first day posttransplantation samples of urine (n=67) and blood (n=80) from graft recipients and analyzed according to donor type (living or deceased) and DGF occurrence. RESULTS: Expression levels of both genes were higher in biopsies from deceased donors than from living donors (P<0.001 for both) but did not differ between deceased-donor kidney transplants with and without DGF; in urine, TLR4 expression levels were higher in patients with prolonged DGF (DGF lasting >14 days) (P=0.05, compared with cases without DGF); in blood, lower mRNA levels of TLR4 and MYD88 predicted pDGF occurrence with an accuracy of 86% and 87%, respectively. CONCLUSION: The expression levels of TLR4 and MYD88 were higher in kidneys from deceased donors than from living donors. Lower levels of expression of both genes in blood were associated with DGF occurrence. The prediction of prolonged DGF by low TLR4 and MYD88 expression levels in blood with a greater the 85% accuracy was the most important finding of this study.


Subject(s)
Delayed Graft Function/genetics , Kidney Transplantation/adverse effects , Kidney/metabolism , RNA, Messenger/metabolism , Toll-Like Receptor 4/genetics , Adult , Aged , Biomarkers/metabolism , Biopsy , Delayed Graft Function/diagnosis , Delayed Graft Function/etiology , Delayed Graft Function/immunology , Delayed Graft Function/metabolism , Humans , Immunity, Innate , Kidney/immunology , Kidney Transplantation/immunology , Living Donors , Middle Aged , Myeloid Differentiation Factor 88/genetics , Predictive Value of Tests , RNA, Messenger/blood , RNA, Messenger/urine , Real-Time Polymerase Chain Reaction , Risk Assessment , Risk Factors , Sensitivity and Specificity , Time Factors , Toll-Like Receptor 4/blood , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL