Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Biomacromolecules ; 25(4): 2312-2322, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38456765

ABSTRACT

Local delivery of pain medication can be a beneficial strategy to address pain management after joint replacement, as it can decrease systemic opioid usage, leading to less side and long-term effects. In this study, we used ultrahigh molecular weight polyethylene (UHMWPE), commonly employed as a bearing material for joint implants, to deliver a wide set of analgesics and the nonsteroidal anti-inflammatory drug tolfenamic acid. We blended the drugs with UHMWPE and processed the blend by compression molding and sterilization by low-dose gamma irradiation. We studied the chemical stability of the eluted drugs, drug elution, tensile properties, and wear resistance of the polymer blends before and after sterilization. The incorporation of bupivacaine hydrochloride and tolfenamic acid in UHMWPE resulted in either single- or dual-drug loaded materials that can be sterilized by gamma irradiation. These compositions were found to be promising for the development of clinically relevant drug-eluting implants for joint replacement.


Subject(s)
Arthroplasty, Replacement , ortho-Aminobenzoates , Materials Testing , Polyethylenes/chemistry , Analgesics , Anti-Inflammatory Agents, Non-Steroidal
2.
Acta Biomater ; 93: 63-73, 2019 07 15.
Article in English | MEDLINE | ID: mdl-31173960

ABSTRACT

Total joint replacement is a widely used and successful surgical approach. Approximately 7 million US adults are currently living with a hip or knee replacement. However, the surgical procedures for total joint replacement are associated with significant postoperative pain, and current strategies do not adequately address this pain, which leads to patient dissatisfaction, reduced mobility, and increased risk of opioid addiction. We hypothesized that the ultra-high-molecular-weight polyethylene (UHMWPE) bearing surfaces used in total joint prosthetics could provide sustained release of the local anesthetic bupivacaine to provide relief from joint pain for an extended period of time after surgery. In this paper, we describe the production of bupivacaine-loaded UHMWPE (BPE) and measure the in vitro bupivacaine release kinetics of BPE. We found that bupivacaine could be released from BPE at clinically relevant rates for up to several days and that BPE possesses antibacterial effects. Therefore, bupivacaine-loaded UHMWPE is a promising material for joint replacement prostheses, and future studies will evaluate its safety and efficacy in in vivo models. STATEMENT OF SIGNIFICANCE: Total joint replacement is associated with significant pain and risk of infection. In our paper, we introduce bupivacaine-loaded ultra-high-molecular-weight polyethylene (BPE), which releases bupivacaine, a pain-treating drug, at doses comparable to currently used doses. Additionally, BPE inhibits the growth of infection-causing bacteria. Therefore, BPE may be able to reduce both postsurgical pain and risk of infection, potentially treating two of the most prominent complications associated with total joint replacement. To our knowledge, this is the first development of a material that can address both complications, and devices incorporating BPE would represent a significant advancement in joint arthroplasty prosthetics. More generally, the incorporation of therapeutic agents into ultra-high-molecular-weight polyethylene could impact many orthopedic procedures owing to its ubiquity.


Subject(s)
Anesthetics, Local/chemistry , Bupivacaine/chemistry , Pain, Postoperative/drug therapy , Polyethylenes/chemistry , Analgesia , Anesthetics, Local/pharmacokinetics , Arthroplasty, Replacement, Knee , Bupivacaine/pharmacokinetics , Coated Materials, Biocompatible/chemistry , Delayed-Action Preparations/chemistry , Dose-Response Relationship, Drug , Drug Delivery Systems , Drug Liberation , Humans , Pain Management , Staphylococcal Infections/drug therapy , Staphylococcal Infections/prevention & control , Staphylococcus aureus/drug effects , Tensile Strength , Treatment Outcome
3.
Article in English | MEDLINE | ID: mdl-30323945

ABSTRACT

Mucus is a biological gel that lines all wet epithelia in the body, including the mouth, lungs, and digestive tract, and has evolved to protect the body from pathogenic infection. However, microbial pathogenesis is often studied in mucus-free environments that lack the geometric constraints and microbial interactions in physiological three-dimensional mucus gels. We developed fluid-flow and static test systems based on purified mucin polymers, the major gel-forming constituents of the mucus barrier, to understand how the mucus barrier influences bacterial virulence, particularly the integrity of Pseudomonas aeruginosa biofilms, which can become resistant to immune clearance and antimicrobial agents. We found that mucins separate the cells in P. aeruginosa biofilms and disperse them into suspension. Other viscous polymer solutions did not match the biofilm disruption caused by mucins, suggesting that mucin-specific properties mediate the phenomenon. Cellular dispersion depended on functional flagella, indicating a role for swimming motility. Taken together, our observations support a model in which host mucins are key players in the regulation of microbial virulence. These mucins should be considered in studies of mucosal pathogenesis and during the development of novel strategies to treat biofilms.

4.
Biophys J ; 113(9): 2088-2099, 2017 Nov 07.
Article in English | MEDLINE | ID: mdl-29117531

ABSTRACT

The nuclear pore complex controls the passage of molecules via hydrophobic phenylalanine-glycine (FG) domains on nucleoporins. Such FG domains consist of repeating units of FxFG, FG, or GLFG sequences, many of which are interspersed with highly charged amino acid sequences. Despite the high density of charge in certain FG domains, if and how charge influences FG-domain self-assembly and selective binding of nuclear transport receptors is largely unexplored. Using rationally designed short peptide sequences, we determined that the charge type and identity of amino acids surrounding FG sequences impact the structure and selectivity of FG-based gels. Moreover, we showed that spatial localization of the charged amino acids with respect to the FG sequence determines the degree to which charge influences hydrophobic interactions. Taken together, our study highlights that charge type and placement of amino acids regulate FG-sequence function and are important considerations when studying the mechanism of nuclear pore complex transport in vivo.


Subject(s)
Hydrophobic and Hydrophilic Interactions , Nuclear Pore/chemistry , Nuclear Pore/metabolism , Amino Acid Sequence , Protein Binding , Protein Domains , Static Electricity
5.
Soft Matter ; 13(22): 4057-4065, 2017 Jun 07.
Article in English | MEDLINE | ID: mdl-28534049

ABSTRACT

Control over the viscoelastic mechanical properties of hydrogels intended for use as biomedical materials has long been a goal of soft matter scientists. Recent research has shown that materials made from polymers with reversibly associating transient crosslinks are a promising strategy for controlling viscoelasticity in hydrogels, for example leading to systems with precisely tunable mechanical energy-dissipation. We and others have shown that bio-inspired histidine:transition metal ion complexes allow highly precise and tunable control over the viscoelastic properties of transient network hydrogels. In this paper, we extend the design of these hydrogels such that their viscoelastic properties respond to longwave UV radiation. We show that careful selection of the histidine:transition metal ion crosslink mixtures allows unique control over pre- and post-UV viscoelastic properties. We anticipate that our strategy for controlling stimuli-responsive viscoelastic properties will aid biomedical materials scientists in the development of soft materials with specific stress-relaxing or energy-dissipating properties.

6.
Nat Mater ; 14(12): 1210-6, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26322715

ABSTRACT

In conventional polymer materials, mechanical performance is traditionally engineered via material structure, using motifs such as polymer molecular weight, polymer branching, or block copolymer design. Here, by means of a model system of 4-arm poly(ethylene glycol) hydrogels crosslinked with multiple, kinetically distinct dynamic metal-ligand coordinate complexes, we show that polymer materials with decoupled spatial structure and mechanical performance can be designed. By tuning the relative concentration of two types of metal-ligand crosslinks, we demonstrate control over the material's mechanical hierarchy of energy-dissipating modes under dynamic mechanical loading, and therefore the ability to engineer a priori the viscoelastic properties of these materials by controlling the types of crosslinks rather than by modifying the polymer itself. This strategy to decouple material mechanics from structure is general and may inform the design of soft materials for use in complex mechanical environments. Three examples that demonstrate this are provided.


Subject(s)
Metals/chemistry , Polymers/chemistry , Elasticity , Hydrogels/chemistry , Viscosity
7.
ACS Macro Lett ; 4(4): 458-461, 2015 Apr 21.
Article in English | MEDLINE | ID: mdl-35596313

ABSTRACT

The inverse-electron demand Diels-Alder cycloaddition of tetrazines and olefins has emerged as a powerful coupling reaction for the formation of polymer gels with diverse applications. Tetrazines are also excellent ligands for metal atoms. For example, 3,6-bis(2-pyridyl)-1,2,4,5-tetrazines (bptz) have been used to generate discrete supramolecular Mxbptzy metal clusters and extended 2D grid structures. We reasoned that both the Diels-Alder and the metal-coordination modes of reactivity of bptz derivatives could be leveraged in the context of hydrogel design to yield novel hybrid materials. Here we report on the formation of supramolecular hydrogels via substoichiometric Diels-Alder functionalization of bptz ligands bound to the ends of poly(ethylene glycol) (PEG) chains followed by metal-coordination-induced gelation in the presence of Ni2+ and Fe2+ salts. Our results show that simple bptz-based polymers are versatile precursors to a diverse range of novel functional materials.

SELECTION OF CITATIONS
SEARCH DETAIL
...