Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Hand Surg Glob Online ; 6(4): 583-589, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39166213

ABSTRACT

Carpal giant cell tumor of bone spanning multiple bones is a rare condition. We present a case of a man in his fifth decade with wrist pain who was found to have giant cell tumor of bone involving his capitate and hamate bones. This condition was successfully treated with intralesional curettage, argon beam coagulation, chemical cauterization and a cemented limited carpal fusion with satisfactory outcomes and no recurrence at 1-year postoperative follow-up.

2.
Skeletal Radiol ; 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38653786

ABSTRACT

OBJECTIVE: To prospectively evaluate a deep learning-based denoising reconstruction (DLR) for improved resolution and image quality in musculoskeletal (MSK) magnetic resonance imaging (MRI). METHODS: Images from 137 contrast-weighted sequences in 40 MSK patients were evaluated. Each sequence was performed twice, first with the routine parameters and reconstructed with a routine reconstruction filter (REF), then with higher resolution and reconstructed with DLR, and with three conventional reconstruction filters (NL2, GA43, GA53). The five reconstructions (REF, DLR, NL2, GA43, and GA53) were de-identified, randomized, and blindly reviewed by three MSK radiologists using eight scoring criteria and a forced ranking. Quantitative SNR, CNR, and structure's full width at half maximum (FWHM) for resolution assessment were measured and compared. To account for repeated measures, Generalized Estimating Equations (GEE) with Bonferroni adjustment was used to compare the reader's scores, SNR, CNR, and FWHM between DLR vs. NL2, GA43, GA53, and REF. RESULTS: Compared to the routine REF images, the resolution was improved by 47.61% with DLR from 0.39 ± 0.15 mm2 to 0.20 ± 0.06 mm2 (p < 0.001). Per-sequence average scan time was shortened by 7.93% with DLR from 165.58 ± 21.86 s to 152.45 ± 25.65 s (p < 0.001). Based on the average scores, DLR images were rated significantly higher in all image quality criteria and the forced ranking (p < 0.001). CONCLUSION: This prospective clinical evaluation demonstrated that DLR allows approximately two times finer resolution and improved image quality compared to the standard-of-care images.

SELECTION OF CITATIONS
SEARCH DETAIL