Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Sci Rep ; 14(1): 6888, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38519582

ABSTRACT

The transition to sustainable power infrastructure necessitates integrating various renewable energy sources efficiently. Our study introduces the deterministic balanced method (DBM) for optimizing hybrid energy systems, with a particular focus on using hydrogen for energy balance. The DBM translates the sizing optimization problem into a deterministic one, significantly reducing the number of iterations compared to state-of-the-art methods. Comparative analysis with HOMER Pro demonstrates a strong alignment of results, with deviations limited to a 5% margin, confirming the precision of our method in sizing determinations. Utilizing solar and wind data, our research includes a case study of Cairo International Airport, applying the DBM to actual energy demands.

2.
Sensors (Basel) ; 24(4)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38400214

ABSTRACT

Earlier protection methods mainly focused on using communication channels to transmit trip signals between the protective devices (PDs), with no solutions provided in the case of communication failure. Therefore, this paper introduces a dual-layer protection system to ensure secure protection against fault events in the Distribution Systems (DSs), particularly in light of communication failures. The initial layer uses the Total Harmonic Distortion (THD), the estimates of the amplitude voltages, and the zero-sequence grid voltage components, functioning as a fault sensor, to formulate an adaptive algorithm based on a Finite State Machine (FSM) for the detection and isolation of faults within the grid. This layer primarily relies on communication protocols for effective coordination. A Second-Order Generalized Integrator (SOGI) expedites the derivation of the estimated variables, ensuring fast detection with minimal computational overhead. The second layer uses the behavior of the positive- and negative-sequence components of the grid voltages during fault events to locate and isolate these faults. In the event that the first layer exposes a communication failure, the second layer will automatically be activated to ensure secure protection as it operates, using the local information of the Protective devices (PDs), without the need for communication channels to transmit trip signals between the PDs. The proposed protection system has been assessed using simulations with MATLAB/Simulink and providing experimental results considering an IEEE 9-bus standard radial system. The obtained results confirm the capability of the system for identifying and isolating different types of faults, varying conditions, and modifications to the grid configuration. The results show good behavior of the initial THD-based layer, with fast time responses ranging from 6 to 8.5 ms in all the examined scenarios. In contrast, the sequence-based layer exhibits a protection time response of approximately 150 ms, making it a viable backup option in the event of a communication failure.

3.
PLoS One ; 18(12): e0295941, 2023.
Article in English | MEDLINE | ID: mdl-38134013

ABSTRACT

This work analyzes the stability and performance of an offshore solar-concentrated ocean thermal energy conversion system (SC-OTEC) tied to an onshore AC grid. The OTEC is a system where electricity is generated using small temperature differences between the warm surface and deep cold ocean water. Existing control methods for SC-OTEC systems lack coordination, hindering dynamic stability and effective damping for the synchronous generator (SG). These methods struggle to quickly adapt to sudden disturbances and lack the capability to adequately reject or compensate for such disturbances due to complex control constraints and computational demands. To this regard, a control strategy combining sliding mode control (SMC) and a power system stabilizer (PSS) to improve the SC-OTEC dynamic stability and damping features for the SG. Moreover, an auxiliary secondary automatic voltage regulator is assembled with a non-linear exciter system to provide damping features. The proposed PID-PSS and secondary AVR controller gains are adaptively tuned using a modified whale optimization algorithm with the balloon effect modulation. The studied SC-OTEC is tested through MATLAB/Simulink under a severe 3ϕ short-circuit fault, solar radiation variations, and a change in surface seawater temperature as well as changes in local loads. The final findings approved that the proposed control strategy preserves a strong performance and can mimic effectively the proposed SC-OTEC damping compared to the conventional system.


Subject(s)
Aircraft , Algorithms , Animals , Cetacea , Computer Systems , Electricity , Excipients , Water
4.
Sensors (Basel) ; 23(10)2023 May 18.
Article in English | MEDLINE | ID: mdl-37430787

ABSTRACT

The integration of Distributed Generators (DGs) into distribution systems (DSs) leads to more reliable and efficient power delivery for customers. However, the possibility of bi-directional power flow creates new technical problems for protection schemes. This poses a threat to conventional strategies because the relay settings have to be adjusted depending on the network topology and operational mode. As a solution, it is important to develop novel fault protection techniques to ensure reliable protection and avoid unnecessary tripping. In this regard, Total Harmonic Distortion (THD) can be used as a key parameter for evaluating the grid's waveform quality during fault events. This paper presents a comparison between two DS protection strategies that employ THD levels, estimated amplitude voltages, and zero-sequence components as instantaneous indicators during the faults that function as a kind of fault sensor to detect, identify, and isolate faults. The first method uses a Multiple Second Order Generalized Integrator (MSOGI) to obtain the estimated variables, whereas the second method uses a single SOGI for the same purpose (SOGI-THD). Both methods rely on communication lines between protective devices (PDs) to facilitate coordinated protection. The effectiveness of these methods is assessed by using simulations in MATLAB/Simulink considering various factors such as different types of faults and DG penetrations, different fault resistances and fault locations in the proposed network. Moreover, the performance of these methods is compared with conventional overcurrent and differential protections. The results show that the SOGI-THD method is highly effective in detecting and isolating faults with a time interval of 6-8.5 ms using only three SOGIs while requiring only 447 processor cycles for execution. In comparison to other protection methods, the SOGI-THD method exhibits a faster response time and a lower computational burden. Furthermore, the SOGI-THD method is robust to harmonic distortion, as it considers pre-existing harmonic content before the fault and avoids interference with the fault detection process.

5.
Sensors (Basel) ; 23(2)2023 Jan 14.
Article in English | MEDLINE | ID: mdl-36679778

ABSTRACT

The rapid growth of the distributed generators (DGs) integration into the distribution systems (DSs) creates new technical issues; conventional relay settings need to be updated depending on the network topology and operational mode as fault protection a major challenge. This emphasizes the need for new fault protection methods to ensure secure protection and prevent undesirable tripping. Total harmonic distortion (THD) is an important indicator for assessing the quality of the grid. Here, a new protection system based on the THD of the grid voltages is proposed to address fault events in the electrical distribution network. The proposed protection system combines the THD with the estimates of the amplitude voltages and the zero-sequence component for defining an algorithm based on a finite state machine (FSM) for the detection, identification, and isolation of faults in the grid. The algorithm employs communication lines between all the protective devices (PDs) of the system to transmit tripping signals, allowing PDs to be coordinated. A second order generalized integrator (SOGI) and multiple SOGI (MSOGI) are used to obtain the THDs, estimated amplitude voltages, and zero-sequence component, which allows for fast detection with a low computational burden. The protection algorithm performance is evaluated through simulations in MATLAB/Simulink and a comparative study is developed between the proposed protection method and a differential relay (DR) protection system. The proposed method shows its capability to detect and isolate faults during different fault types with different fault resistances in different locations in the proposed network. In all the tested scenarios, the detection time of the faults has been between 7-10 ms. Moreover, this method gave the best solution as it has a higher accuracy and faster response than the conventional DR protection system.


Subject(s)
Algorithms , Communication , Physical Phenomena , Computer Systems , Electricity
6.
ISA Trans ; 132: 557-572, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35778111

ABSTRACT

This paper proposes a discrete-time fuzzy fractional-order sliding-mode control (Fuzzy-FOSMC) dual loop current controller for a three-phase LCL-type grid-connected converter (GCC) with reduced order. Conventional sliding-mode control (SMC) has been widely used in GCC due to its robustness to disturbances. However, the chattering in SMC may reduce the tracking performance of the controller, and even lead to system instability. To solve this problem, a Fuzzy-FOSMC controller is proposed in this paper. The introduced fractional-order term can suppress the chattering, and the fractional-order of FOSMC is further adjusted by the fuzzy controller to improve the overall system performance. In addition, the inner loop is implemented by a Fuzzy-FOSMC controller to ensure the tracking of the converter-side current, making the LCL-GCC converter behave like a controllable current source converter with a capacitive-inductive filter, the grid current control problem falls from a third-order to a reduced order system, which solves some difficulties on the design of most controller types. The stability of the two-stage PV system is analyzed. Finally, the effectiveness of the proposed controller is verified by experiments.

7.
Front Plant Sci ; 13: 970410, 2022.
Article in English | MEDLINE | ID: mdl-36340344

ABSTRACT

Modelling higher plant growth is of strategic interest for modern agriculture as well as for the development of bioregenerative life support systems for space applications, where crop growth is expected to play an essential role. The capability of constraint-based metabolic models to cope the diel dynamics of plants growth is integrated into a multilevel modelling approach including mass and energy transfer and enzyme kinetics. Lactuca sativa is used as an exemplary crop to validate, with experimental data, the approach presented as well as to design a novel model-based predictive control strategy embedding metabolic information. The proposed modelling strategy predicts with high accuracy the dynamics of gas exchange and the distribution of fluxes in the metabolic network whereas the control architecture presented can be useful to manage higher plants chambers and open new ways of merging metabolome and control algorithms.

8.
Sensors (Basel) ; 22(16)2022 Aug 11.
Article in English | MEDLINE | ID: mdl-36015769

ABSTRACT

A Microgrid (MG), like any other smart and interoperable power system, requires device-to-device (D2D) communication structures in order to function effectively. This communication system, however, is not immune to intentional or unintentional failures. This paper discusses the effects of communication link failures on MG control and management and proposes solutions based on enhancing message content to mitigate their detritus impact. In order to achieve this goal, generation and consumption forecasting using deep learning (DL) methods at the next time steps is used. The architecture of an energy management system (EMS) and an energy storage system (ESS) that are able to operate in coordination is introduced and evaluated by simulation tests, which show promising results and illustrate the efficacy of the proposed methods. It is important to mention that, in this paper, three dissimilar topics namely MG control/management, DL-based forecasting, and D2D communication architectures are employed and this combination is proven to be capable of achieving the aforesaid objective.


Subject(s)
Deep Learning , Communication , Computer Simulation , Forecasting
9.
Micromachines (Basel) ; 13(6)2022 Jun 07.
Article in English | MEDLINE | ID: mdl-35744516

ABSTRACT

In view of the frequent safety problems of electric vehicles, the research on accurately obtaining the rotor position of the motor through the resolver is an important means to improve the functional safety of the system. The commonly used resolver decoding method involves the resolver decoding chip method and software decoding method, but few studies integrate the two decoding methods. A single method of motor rotor position acquisition cannot meet the requirements of system functional safety. To fill this gap, this paper proposes a method to simultaneously integrate hardware decoding and software decoding in the motor control system. The decoding chip and software decoding obtain the angle data at the same time, and they provide redundancy to improve the functional safety of the electronic control system. Finally, the effectiveness of the proposed simultaneous operation of hardware decoding and software decoding is verified by experiments.

10.
Article in English | MEDLINE | ID: mdl-34360439

ABSTRACT

The increasing integration of Renewable Energy Resources (RERs) in distribution networks forms the Networked Renewable Energy Resources (NRERs). The cooperative Peer-to-Peer (P2P) control architecture is able to fully exploit the resilience and flexibility of NRERs. This study proposes a multi-agent system to achieve P2P control of NRERs based Internet of Things (IoT). The control system is fully distributed and contains two control layers operated in the agent of each RER. For primary control, a droop control is adopted by each RER-agent for localized power sharing. For secondary control, a distributed diffusion algorithm is proposed for arbitrary power sharing among RERs. The proposed levels communication system is implemented to explain the data exchange between the distribution network system and the cloud server. The local communication level utilizes the Internet Protocol (IP)/Transmission Control Protocol (TCP), and Message Queuing Telemetry Transport (MQTT) is used as the protocol for the global communication level. The effectiveness of the proposed system is validated by numerical simulation with the modified IEEE 9 node test feeder. The controller proposed in this paper achieved savings of 20.65% for the system, 25.99% for photovoltaic, 35.52 for diesel generator, 24.59 for batteries, and 52.34% for power loss.


Subject(s)
Internet of Things , Renewable Energy , Algorithms , Computer Simulation , Software
11.
Entropy (Basel) ; 23(4)2021 Apr 20.
Article in English | MEDLINE | ID: mdl-33924067

ABSTRACT

Optimization seeks to find inputs for an objective function that result in a maximum or minimum. Optimization methods are divided into exact and approximate (algorithms). Several optimization algorithms imitate natural phenomena, laws of physics, and behavior of living organisms. Optimization based on algorithms is the challenge that underlies machine learning, from logistic regression to training neural networks for artificial intelligence. In this paper, a new algorithm called two-stage optimization (TSO) is proposed. The TSO algorithm updates population members in two steps at each iteration. For this purpose, a group of good population members is selected and then two members of this group are randomly used to update the position of each of them. This update is based on the first selected good member at the first stage, and on the second selected good member at the second stage. We describe the stages of the TSO algorithm and model them mathematically. Performance of the TSO algorithm is evaluated for twenty-three standard objective functions. In order to compare the optimization results of the TSO algorithm, eight other competing algorithms are considered, including genetic, gravitational search, grey wolf, marine predators, particle swarm, teaching-learning-based, tunicate swarm, and whale approaches. The numerical results show that the new algorithm is superior and more competitive in solving optimization problems when compared with other algorithms.

12.
Sci Rep ; 10(1): 15335, 2020 09 18.
Article in English | MEDLINE | ID: mdl-32948807

ABSTRACT

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

13.
Sci Rep ; 10(1): 12176, 2020 Jul 22.
Article in English | MEDLINE | ID: mdl-32699210

ABSTRACT

The static synchronous series compensator (SSSC) can add a series reactance to the transmission line, and when it is fed using auxiliary signals, it can participate in damping inter-area oscillations by changing the series reactance. In this paper, the effect of the SSSC on small-signal stability is investigated. The design of a controller for damping oscillations is designed and discussed. Moreover, using the firefly and the harmony search algorithms, the optimal parameters controlling SSSC are addressed. The effectiveness of these two algorithms and the rate of SSSC participation in damping inter-area oscillation are also discussed. MATLAB software was used to analyse the models and to perform simulations in the time domain. The simulation results on the sample system, in two areas, indicated the optimal accuracy and precision of the proposed controller.

14.
PLoS One ; 12(2): e0164856, 2017.
Article in English | MEDLINE | ID: mdl-28192436

ABSTRACT

In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method.


Subject(s)
Algorithms , Electric Power Supplies , Equipment Design/instrumentation , Renewable Energy , Signal Processing, Computer-Assisted/instrumentation , Electricity , Electrodes
SELECTION OF CITATIONS
SEARCH DETAIL
...