Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Microsc Microanal ; 25(6): 1297-1303, 2019 12.
Article in English | MEDLINE | ID: mdl-31407642

ABSTRACT

From simple averaging to more sophisticated registration and restoration strategies, such as super-resolution (SR), there exist different computational techniques that use a series of images of the same object to generate enhanced images where noise and other distortions have been reduced. In this work, we provide qualitative and quantitative measurements of this enhancement for high-angle annular dark-field scanning transmission electron microscopy imaging. These images are compared in two ways, qualitatively through visual inspection in real and reciprocal space, and quantitatively, through the calculation of objective measurements, such as signal-to-noise ratio and atom column roundness. Results show that these techniques improve the quality of the images. In this paper, we use an SR methodology that allows us to take advantage of the information present in the image frames and to reliably facilitate the analysis of more difficult regions of interest in experimental images, such as surfaces and interfaces. By acquiring a series of cross-sectional experimental images of magnetite (Fe3O4) thin films (111), we have generated interpolated images using averaging and SR, and reconstructed the atomic structure of the very top surface layer that consists of a full monolayer of Fe, with topmost Fe atoms in tetrahedrally coordinated sites.

2.
Micron ; 110: 18-27, 2018 07.
Article in English | MEDLINE | ID: mdl-29705338

ABSTRACT

During image acquisition of crystalline materials by high-resolution scanning transmission electron microscopy, the sample drift could lead to distortions and shears that hinder their quantitative analysis and characterization. In order to measure and correct this effect, several authors have proposed different methodologies making use of series of images. In this work, we introduce a methodology to determine the drift angle via Fourier analysis by using a single image based on the measurements between the angles of the second Fourier harmonics in different quadrants. Two different approaches, that are independent of the angle of acquisition of the image, are evaluated. In addition, our results demonstrate that the determination of the drift angle is more accurate by using the measurements of non-consecutive quadrants when the angle of acquisition is an odd multiple of 45°.

3.
Ultramicroscopy ; 182: 283-291, 2017 11.
Article in English | MEDLINE | ID: mdl-28783580

ABSTRACT

High-quality image reconstruction techniques allow the generation of high pixel density images from a set of low-resolution micrographs. In general, these techniques consist of two main steps, namely, accurate registration, and formulation of an appropriate forward image model via some restoration method. There exist a wide variety of algorithms to cope with both stages and depending on their practical applications, some methods can outperform others, since they can be sensitive to the assumed data model, noise, drift, etc. When dealing with images generated by Z-contrast scanning transmission electron microscopes, a current trend is based on non-rigid approximations in the registration stage. In our work we aimed at reaching similar accuracy but addressing the most complex calculations in the reconstruction stage, instead of in the registration stage (as the non-rigid approaches do), but using a much smaller number of images. We review some of the most significant methods and address their shortcomings when they are applied to the field of microscopy. Simulated images with known targets will be used to evaluate and compare the main approaches in terms of quality enhancement and computing time. In addition, a procedure to determine the reference image will be proposed to minimise the global drift on the series. The best registration and restoration strategies will be applied to experimental images in order to point up the enhanced capability of this high quality image reconstruction methodology in this field.

4.
J Microsc ; 262(1): 50-8, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26501744

ABSTRACT

Super-resolution (SR) software-based techniques aim at generating a final image by combining several noisy frames with lower resolution from the same scene. A comparative study on high-resolution high-angle annular dark field images of InAs/GaAs QDs has been carried out in order to evaluate the performance of the SR technique. The obtained SR images present enhanced resolution and higher signal-to-noise (SNR) ratio and sharpness regarding the experimental images. In addition, SR is also applied in the field of strain analysis using digital image processing applications such as geometrical phase analysis and peak pairs analysis. The precision of the strain mappings can be improved when SR methodologies are applied to experimental images.

5.
Phys Rev Lett ; 113(13): 135503, 2014 Sep 26.
Article in English | MEDLINE | ID: mdl-25302902

ABSTRACT

We demonstrate that the aberration-corrected scanning transmission electron microscope has a sufficiently small depth of field to observe depth-dependent atomic displacements in a crystal. The depth-dependent displacements associated with the Eshelby twist of dislocations in GaN normal to the foil with a screw component of the Burgers vector are directly imaged. We show that these displacements are observed as a rotation of the lattice between images taken in a focal series. From the sense of the rotation, the sign of the screw component can be determined.

SELECTION OF CITATIONS
SEARCH DETAIL
...