Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Neurosurg Rev ; 47(1): 217, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38736006

ABSTRACT

Dural Arteriovenous Fistulas (dAVFs) of the anterior cranial fossa (ACF) are uncommon but carry a high risk of hemorrhage and pose substantial treatment challenges. Recent advancements in endovascular treatment (EVT), including the introduction of novel liquid embolic agents, have markedly bolstered EVT's role in managing ACF-dAVFs, with notable series published in the last five years. We aimed to assess the feasibility, safety, and efficacy of EVT for ACF-dAVFs. We searched Medline, Scopus, Web of Science, and Cochrane Library databases following PRISMA guidelines. Eligible studies included those with ≥ 5 patients undergoing embolization of ACF-dAVFs, detailing both angiographic and clinical outcomes. We used single proportion analysis with 95% confidence intervals under a random-effects model, I2 to assess heterogeneity, and Baujat and sensitivity analysis to address high heterogeneity. Publication bias was assessed by funnel-plot analysis and Egger's test. Outcomes included complete occlusion following embolization, unsuccessful endovascular embolization attempts, incomplete occlusion following embolization, symptom resolution or clinical improvement following embolization, recurrence; procedure-related complications, morbidity, and mortality. Additionally, a subanalysis for studies exclusively utilizing Onyx™ embolic system was done. Eighteen studies comprising 231 ACF-dAVF were included. Unsuccessful endovascular embolization attempts rate was 2%. Complete occlusion rate was 85%, with 4% of complications. Incomplete occlusion rate was 10%. Successfully embolized patients experienced either symptom resolution or clinical improvement in 94% of cases. Morbidity and mortality rates were 1% and 0%, respectively. Onyx subanalyses showed an overall rate of 0% for unsuccessful attempts, 95% for complete occlusion, and 5% for incomplete occlusion. Symptom resolution or clinical improvement was 98% and recurrence rate was 0%. EVT for ACF-dAVF is highly feasible, effective, and safe, with a low rate of complications, morbidity, and mortality. The subanalyses focusing on Onyx embolizations revealed superior efficacy and safety outcomes compared to the findings of the primary analyses involving all included studies.


Subject(s)
Central Nervous System Vascular Malformations , Cranial Fossa, Anterior , Embolization, Therapeutic , Endovascular Procedures , Polyvinyls , Humans , Central Nervous System Vascular Malformations/therapy , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Polyvinyls/therapeutic use , Treatment Outcome , Dimethyl Sulfoxide/therapeutic use , Feasibility Studies
2.
Neuroradiol J ; : 19714009241247462, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622821

ABSTRACT

INTRODUCTION: Wide-necked bifurcation aneurysms pose significant challenges for endovascular treatment. A recent innovation, the stent plus balloon-assisted coiling technique, combines a stent and a balloon to address these aneurysms effectively. PURPOSE: To evaluate the safety and efficacy of the stent plus balloon-assisted coiling for the treatment of wide-necked bifurcation aneurysms. METHODS: We conducted a retrospective review of our endovascular database to identify patients who were treated with this technique and had a satisfactory angiographic follow-up of at least 24 months. Technical success, initial clinical and angiographic outcomes, procedural complications, and follow-up results were analyzed. Angiographic and clinical outcomes were assessed using Modified Raymond-Roy Classification and Modified Rankin Scale, respectively. RESULTS: Our study included 37 aneurysms in 36 patients (26 females) with a mean age of 56.6 years. Mean aneurysm and neck sizes were 7.3 ± 3.5 mm and 3.7 ± 1.0 mm, respectively. Technical success reached 97.2%, with an immediate occlusion rate of 65.7%. At a mean follow-up of 36.5 ± 9.7 months, final angiographic follow-up showed a 91.9% complete occlusion rate. Three aneurysms did not achieve complete occlusion; however, none required retreatment. Complications developed in 32.4% of the procedures. Mortality and morbidity rates were 5.4% and 2.7%, respectively. A good clinical outcome was observed in 91.9% of patients. CONCLUSION: Our results showed that stent plus balloon-assisted coiling technique allows good angiographic outcomes for wide-necked bifurcation aneurysms. However, overall complication rate is high. Subgroup analysis indicated promising safety and efficacy for MCA bifurcation aneurysms, suggesting this technique could be a valuable option for select aneurysms.

3.
Neurosurg Rev ; 47(1): 123, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38503965

ABSTRACT

Low-profile stents may provide significant advantages in Y-stent-assisted coiling due to their miniaturized design and capability to be delivered through a 0.0165-inch microcatheter. We aim to investigate the safety and efficacy of using these newer versions of stents in Y-stent-assisted coiling for the treatment of wide-necked bifurcation aneurysms. We conducted a systematic review of the PubMed, Embase, Cochrane Library, and Web of Science databases up to September 2023, following the PRISMA guidelines. Eligible studies included ≥ 5 patients with intracranial wide-necked bifurcation aneurysms treated with Y-stent-assisted coiling using low-profile stents, providing angiographic and clinical outcomes. Two authors independently handled the search and selection. Primary outcomes were immediate and follow-up aneurysm occlusion, procedure-related complications, aneurysm recanalization, and retreatment. Secondary outcomes included technical success, procedure-related morbidity, procedure-related mortality, procedure-related stroke, and in-stent stenosis at follow-up. We analyzed the data using random-effects meta-analysis. In total, 19 studies including 507 patients with 509 aneurysms were included. 95% of the treated aneurysms were managed using the crossing Y-configuration. Technical success rate was 99%. Immediate adequate aneurysm occlusion was 90%. Follow-up angiographies were available for 443 aneurysms. The mean angiographic follow-up duration was 15.6 ± 1.9 months. The rates for follow-up adequate aneurysm occlusion and complete occlusion were 98% and 89%, respectively. After a mean clinical follow-up of 15 ± 2.4 months, a good clinical outcome was observed in 98% of patients. Overall, procedure-related morbidity and mortality rates were 1.3%, and 0.4%, respectively. Low-profile stents in Y-stent-assisted coiling outperform previous stent versions in terms of safety, efficacy, and technical success rates.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm , Humans , Treatment Outcome , Retrospective Studies , Stents , Intracranial Aneurysm/complications , Cerebral Angiography
SELECTION OF CITATIONS
SEARCH DETAIL
...