Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 277: 126317, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38810383

ABSTRACT

In this study, we present a novel biomarker detection platform employing a modified S-tapered fiber coated with gold nanoparticle/graphene oxide (GNP/GO) for quantifying human epidermal growth factor receptor-2 (HER2) concentrations, using antibodies as sensing elements. The fabrication of this device involves implementing an in-situ layer-by-layer technique coupled with a chemical adsorption step to achieve the self-assembly of GNP, GO, and antibodies on the STF surface. The detection mechanism relies on monitoring the refractive index changes induced by the adsorption of HER2 onto the immobilized antibodies. For comparative analysis, both monoclonal antibody (mAb) and the novel nanobody (Nb) were employed in constructing the STF immunosensor, referred to as the mAb immunosensor and Nb immunosensor, respectively. Spectral analysis results highlight that the Nb immunosensor exhibits twice the sensitivity of the mAb immunosensor. This enhanced sensitivity is attributed to the small size, high antigen affinity, strong specificity, and structural stability of Nb. The Nb immunosensor demonstrated an impressive detection limit of 0.001 nM for HER2, surpassing the detection limit of the mAb immunosensor. These findings underscore the potential of the proposed Nb immunosensor as a promising and sensitive tool for HER2 detection, contributing to the diagnosis and prognosis of breast cancer. Furthermore, the simplicity of production and excellent optical performance position the Nb immunosensor as a prospective real-time biosensor with minimal cytotoxicity.

2.
Opt Lett ; 49(6): 1616-1619, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38489465

ABSTRACT

The S fiber taper (SFT) aptasensor with a composite sensitive membrane of graphene oxide and gold nanoparticles was proposed for the rapid and highly sensitive detection of bisphenol A (BPA). The SFT was obtained using a fusion splicer; subsequently, the composite film was deposited on its surface, and the specific aptamer was covalently bonded to the surface of gold nanoparticles. The detection mechanism relies on monitoring changes in the external refractive index induced by the specific binding of BPA to the aptamer. The developed SFT aptasensor exhibited a remarkable sensitivity of 15.5 nm/nM and a limit of detection as low as 0.01 nM for BPA. These findings highlight the aptasensor's potential for diverse monitoring applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...