Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
J Patient Saf ; 17(8): e1465-e1471, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-30418425

ABSTRACT

ABSTRACT: Suboptimal exchange of information can have tragic consequences to patient's safety and survival. To this end, the Joint Commission lists communication error among the most common attributable causes of sentinel events. The risk management literature further supports this finding, ascribing communication error as a major factor (70%) in adverse events. Despite numerous strategies to improve patient safety, which are rooted in other high reliability industries (e.g., commercial aviation and naval aviation), communication remains an adaptive challenge that has proven difficult to overcome in the sociotechnical landscape that defines healthcare. Attributing a breakdown in information exchange to simply a generic "communication error" without further specification is ineffective and a gross oversimplification of a complex phenomenon. Further dissection of the communication error using root cause analysis, a failure modes and effects analysis, or through an event reporting system is needed. Generalizing rather than categorizing is an oversimplification that clouds clear pattern recognition and thereby prevents focused interventions to improve process reliability. We propose that being more precise when describing communication error is a valid mechanism to learn from these errors. We assert that by deconstructing communication in healthcare into its elemental parts, a more effective organizational learning strategy emerges to enable more focused patient safety improvement efforts. After defining the barriers to effective communication, we then map evidence-based recovery strategies and tools specific to each barrier as a tactic to enhance the reliability and validity of information exchange within healthcare.


Subject(s)
Communication , Patient Safety , Communication Barriers , Delivery of Health Care , Humans , Medical Errors/prevention & control , Reproducibility of Results , Safety Management
2.
Simul Healthc ; 15(1): 39-45, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32028446

ABSTRACT

STATEMENT: Psychological stress arises from a stressor placed on an individual that leads to both emotional and physiological responses. The latter is referred to as psychophysiological stress. Healthcare simulation provides a platform to investigate stress psychobiology and its effects on learning and performance. However, psychophysiological stress measures may be underused in healthcare simulation research. The inclusion of such measures with subjective measures of stress in healthcare simulation research provides a more complete picture of the stress response, thereby furthering the understanding of stress and its impact on learning and performance. The goals of this article were to review 2 commonly used psychophysiological stress measures involving heart rate variability and electrodermal activity reflecting sweat gland activity and to demonstrate their utility in an example pilot study in healthcare simulation research.


Subject(s)
Galvanic Skin Response/physiology , Heart Rate/physiology , Simulation Training/organization & administration , Stress, Psychological/physiopathology , Adult , Female , Humans , Male , Reproducibility of Results , Simulation Training/standards
3.
Am J Surg ; 219(1): 33-37, 2020 01.
Article in English | MEDLINE | ID: mdl-30898304

ABSTRACT

INTRODUCTION: Our simulation center, supported by four departments (Surgery, OB/GYN, Urology, and Anesthesiology), is accredited as a comprehensive Accredited Educational Institute (AEI) and is now expanding to accommodate all departments on campus. METHODS: A 61-point questionnaire was administered to 44 stakeholders, representing all of UME and GME. Data were compared for AEI vs. non-AEI activities. RESULTS: Responses were collected from all 44 groups (100% response rate). Overall, 43 simulation activities were hosted within the AEI and 40 were hosted by non-AEI stakeholders. AEI activities were more likely to be mandatory (93% vs. 75%, p = 0.02), have written learning objectives (79% vs 43%, p < 0.001), and use validated assessment metrics (33% vs. 13%, p = 0.03). CONCLUSION: These data suggest that the AEI courses are more robust in terms of structured learning and assessment compared to non-AEI courses. Campus-wide application of uniform quality standards is anticipated to require significant faculty, course, and program development.


Subject(s)
Academies and Institutes , Accreditation , Health Resources , Internship and Residency/methods , Simulation Training/standards , Specialties, Surgical/education , Surveys and Questionnaires , United States
4.
Simul Healthc ; 14(2): 96-103, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30908420

ABSTRACT

INTRODUCTION: The American Society of Anesthesiologists (ASA) difficult airway algorithm and the Vortex approach are difficult airway aids. Our objective was to demonstrate that a simpler cognitive model would facilitate improved decision-making during a process such as difficult airway management. We hypothesized the simpler Vortex approach would be associated with less anxiety and task load. METHODS: Medical students were randomized to the ASA algorithm (n = 33) or Vortex approach (n = 34). All learned basic airway techniques on day 1 of their rotation. Next, they watched a video of their respective aid then managed a simulated airway crisis. We assessed decision-making using a seven-point airway management score and a completeness score. Completeness was at least one attempt at each of four techniques (mask ventilation, supraglottic airway, intubation, and cricothyrotomy). Two validated tools, the State-Trait Anxiety Inventory Form Y and the National Aeronautics and Space Administration Task Load Index, were used to assess anxiety and task load. RESULTS: Students in the Vortex group had higher airway management scores [4.0 (interquartile range = 4.0 to 5.0) vs. 4.0 (3.0 to 4.0), P = 0.0003] and completeness (94.1% vs. 63.6%, P = 0.003). In the ASA group, the means (SD) of National Aeronautics and Space Administration Task Load Index scores of 55 or higher were observed in mental [61.4 (14.4)], temporal [62.3 (22.9)], and effort [57.1 (15.6)] domains. In the Vortex group, only the temporal load domain was 55 or higher [mean (SD) = 57.8 (25.4)]. There was no difference in anxiety. CONCLUSIONS: Medical students perform better in a simulated airway crisis after training in the simpler Vortex approach to guide decision-making. Students in the ASA group had task load scores indicative of high cognitive load.


Subject(s)
Airway Management/methods , Clinical Decision-Making/methods , Clinical Protocols/standards , Education, Medical/methods , Workload , Adult , Anesthesiology/education , Anxiety/epidemiology , Clinical Competence , Female , Humans , Male , Simulation Training/methods
5.
Pain Pract ; 9(4): 308-11, 2009.
Article in English | MEDLINE | ID: mdl-19496960

ABSTRACT

Spinal cord stimulation (SCS) offers new hope for patients with neuropathic pain. SCS "neuromodulates" the transmission and response to "painful" stimuli. The efficacy of SCS has been established in the treatment of a variety of neuropathic pain conditions and more recently in refractory angina pectoris, peripheral vascular disease, and failed back surgery syndrome. Recent publications suggest that visceral pain could be successfully treated with SCS. We report the first successful use of a spinal cord stimulator in the treatment of refractory neuropathic mediastinal, esophageal, and anterior neck pain following esophagogastrectomy.


Subject(s)
Electric Stimulation Therapy/methods , Mediastinum/physiopathology , Pain, Intractable/therapy , Peripheral Nervous System Diseases/therapy , Spinal Cord/physiology , Afferent Pathways/physiology , Barrett Esophagus/complications , Barrett Esophagus/etiology , Barrett Esophagus/physiopathology , Chest Pain/etiology , Chest Pain/physiopathology , Chest Pain/therapy , Chronic Disease/therapy , Digestive System Surgical Procedures/adverse effects , Digestive System Surgical Procedures/methods , Electric Stimulation Therapy/instrumentation , Electrodes/standards , Humans , Male , Mediastinum/innervation , Middle Aged , Neck Pain/etiology , Neck Pain/physiopathology , Neck Pain/therapy , Pain Measurement , Pain, Intractable/etiology , Pain, Intractable/physiopathology , Pain, Postoperative/therapy , Peptic Ulcer/complications , Peptic Ulcer/surgery , Peripheral Nervous System Diseases/etiology , Peripheral Nervous System Diseases/physiopathology , Posterior Horn Cells/physiology , Treatment Outcome , Visceral Afferents/physiopathology
6.
Pain Pract ; 8(2): 133-7, 2008.
Article in English | MEDLINE | ID: mdl-18194349

ABSTRACT

PURPOSE: Median arcuate ligament syndrome, which presents with intractable visceral pain, is difficult to both diagnose and treat. This case report describes the first use of an intrathecal morphine pump as an effective therapeutic intervention. CLINICAL FEATURES: We describe a 39-year-old female who presented with a four-year history of misdiagnosed debilitating abdominal pain. After multiple failed attempts at medical management and surgeries, a trial of intrathecal narcotics provided significant relief. Six months after insertion of an intrathecal morphine pump, the patient was pain-free and had resumed all activities of daily living. CONCLUSION: The use of an intrathecal narcotic pump should be considered for treatment of patients with intractable visceral pain secondary to median arcuate ligament syndrome.


Subject(s)
Abdominal Pain/therapy , Analgesics, Opioid/administration & dosage , Morphine/administration & dosage , Pain, Intractable/therapy , Adult , Electric Stimulation/methods , Female , Humans , Infusion Pumps, Implantable , Pain Measurement , Spinal Cord/physiology , Spinal Cord/radiation effects
7.
Pain Pract ; 8(1): 62-4, 2008.
Article in English | MEDLINE | ID: mdl-17986160

ABSTRACT

Providing complete anesthesia to the entire upper extremity remains challenging. We present the use of a novel, updated, regional anesthetic technique-an ultrasound-guided supraclavicular-interscalene block (UGSCIS)-to provide anesthesia and analgesia to a patient with end-stage liver disease who required fixation of a pathologic fracture of the humerus.


Subject(s)
Autonomic Nerve Block/methods , Brachial Plexus , Ultrasonography, Interventional , Aged , Anesthetics, Local/administration & dosage , Arm/innervation , Carcinoma, Hepatocellular/surgery , Fracture Fixation, Internal , Fractures, Spontaneous/surgery , Hepatitis C, Chronic/complications , Humans , Humeral Fractures/surgery , Injections , Liver Failure/complications , Liver Neoplasms/complications , Male , Mepivacaine/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL