Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
JACC Cardiovasc Interv ; 14(15): 1704-1713, 2021 08 09.
Article in English | MEDLINE | ID: mdl-34274294

ABSTRACT

OBJECTIVES: Using French transcatheter aortic valve replacement (TAVR) registries linked with the nationwide administrative databases, the study compared the rates of long-term mortality, bleeding, and ischemic events after TAVR in patients requiring oral anticoagulation with direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs). BACKGROUND: The choice of optimal drug for anticoagulation after TAVR remains debated. METHODS: Data from the France-TAVI and FRANCE-2 registries were linked to the French national health single-payer claims database, from 2010 to 2017. Propensity score matching was used to reduce treatment-selection bias. Two primary endpoints were death from any cause (efficacy) and major bleeding (safety). RESULTS: A total of 24,581 patients who underwent TAVR were included and 8,962 (36.4%) were treated with OAC. Among anticoagulated patients, 2,180 (24.3%) were on DOACs. After propensity matching, at 3 years, mortality (hazard ratio [HR]: 1.37; 95% confidence interval [CI]: 1.12-1.67; P < 0.005) and major bleeding including hemorrhagic stroke (HR: 1.64; 95% CI: 1.17-2.29; P < 0.005) were lower in patients on DOACs compared with those on VKAs. The rates of ischemic stroke (HR: 1.32; 95% CI: 0.81-2.15; P = 0.27) and acute coronary syndrome (HR: 1.17; 95% CI: 0.68-1.99; P = 0.57) did not differ among groups. CONCLUSIONS: In these large multicenter French TAVR registries with an exhaustive clinical follow-up, the long-term mortality and major bleeding were lower with DOACs than VKAs at discharge. The present study supports preferential use of DOACs rather than VKAs in patients requiring oral anticoagulation therapy after TAVR.


Subject(s)
Atrial Fibrillation , Transcatheter Aortic Valve Replacement , Administration, Oral , Anticoagulants/adverse effects , Atrial Fibrillation/drug therapy , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Vitamin K
2.
Circulation ; 138(23): 2597-2607, 2018 12 04.
Article in English | MEDLINE | ID: mdl-30571260

ABSTRACT

BACKGROUND: The FRANCE-2 registry (French Aortic National Corevalve and Edwards) previously reported good early- and medium-term clinical and echocardiographic efficacy for transcatheter aortic valve replacement. We here report 5-year follow-up results from the registry. METHODS: The registry includes all consecutive patients undergoing transcatheter aortic valve replacement for severe aortic stenosis in France. Follow-up is scheduled at 30 days, 6 months, then annually from 1 to 5 years. Clinical events were defined according to the Valve Academic Research Consortium criteria, and hemodynamic structural valve deterioration (SVD) was defined according to the consensus statement by the European Association of Percutaneous Cardiovascular Interventions. RESULTS: Between January 2010 and January 2012, 4201 patients were enrolled in 34 centers. Five-year vital status was available for 95.5% of patients; 88.1% had clinical evaluation or died. Overall, at 5 years, all-cause mortality was 60.8% (n=2478; 95% CI, 59.3% to 62.3%). The majority of cardiovascular events occurred in the first month after valve implantation, and incidence remained low thereafter, at <2% per year up to 5 years, except for heart failure. The rate of heart failure was 14.3% at 1 year, then decreased over time to <5% per year. In cumulative incidence function, the rates of severe SVD and moderate/severe SVD at 5 years were 2.5% and 13.3%, respectively. Mortality did not differ between patients with or without severe SVD (hazard ratio, 0.71; 95% CI, 0.47-1.07; P=0.1). Finally, in the population of patients with severe SVD, 1 patient (1.7%) experienced a stroke, and 8 patients presented ≥1 heart failure event (13.3%). CONCLUSIONS: The 5-year follow-up results of the FRANCE-2 registry represent the largest long-term data set available in a high-risk population. In surviving patients, the low rate of clinical events and the low level of SVD after 1 year support the long-term efficacy of transcatheter aortic valve replacement in both types of transcatheter prosthesis featuring in the registry.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Equipment Failure , Female , Follow-Up Studies , Heart Failure/diagnosis , Heart Failure/epidemiology , Hemodynamics , Humans , Male , Proportional Hazards Models , Registries , Risk Factors , Stroke/diagnosis , Stroke/epidemiology , Survival Analysis , Time Factors , Treatment Outcome
3.
J Am Coll Cardiol ; 68(15): 1637-1647, 2016 10 11.
Article in English | MEDLINE | ID: mdl-27712776

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has revolutionized management of high-risk patients with severe aortic stenosis. However, survival and the incidence of severe complications have been assessed in relatively small populations and/or with limited follow-up. OBJECTIVES: This report details late clinical outcome and its determinants in the FRANCE-2 (FRench Aortic National CoreValve and Edwards) registry. METHODS: The FRANCE-2 registry prospectively included all TAVRs performed in France. Follow-up was scheduled at 30 days, at 6 months, and annually from 1 to 5 years. Standardized VARC (Valve Academic Research Consortium) outcome definitions were used. RESULTS: A total of 4,201 patients were enrolled between January 2010 and January 2012 in 34 centers. Approaches were transarterial (transfemoral 73%, transapical 18%, subclavian 6%, and transaortic or transcarotid 3%) or, in 18% of patients, transapical. Median follow-up was 3.8 years. Vital status was available for 97.2% of patients at 3 years. The 3-year all-cause mortality was 42.0% and cardiovascular mortality was 17.5%. In a multivariate model, predictors of 3-year all-cause mortality were male sex (p < 0.001), low body mass index, (p < 0.001), atrial fibrillation (p < 0.001), dialysis (p < 0.001), New York Heart Association functional class III or IV (p < 0.001), higher logistic EuroSCORE (p < 0.001), transapical or subclavian approach (p < 0.001 for both vs. transfemoral approach), need for permanent pacemaker implantation (p = 0.02), and post-implant periprosthetic aortic regurgitation grade ≥2 of 4 (p < 0.001). Severe events according to VARC criteria occurred mainly during the first month and subsequently in <2% of patients/year. Mean gradient, valve area, and residual aortic regurgitation were stable during follow-up. CONCLUSIONS: The FRANCE-2 registry represents the largest database available on late results of TAVR. Late mortality is largely related to noncardiac causes. Incidence rates of severe events are low after the first month. Valve performance remains stable over time.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Female , France , Humans , Male , Prospective Studies , Registries , Risk Assessment , Time Factors , Treatment Outcome
4.
Eur J Cardiothorac Surg ; 47(5): e206-12, 2015 May.
Article in English | MEDLINE | ID: mdl-25687453

ABSTRACT

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) has emerged as an effective treatment for high-risk patients with severe aortic stenosis (AS). The aim of our study was to compare the prevalence, characteristics and outcomes of high-risk patients treated prior to and after the availability of TAVI in our high-volume surgical institution. METHODS: Among 879 consecutive patients treated 2 years before ('pre-TAVI era') and after ('modern era') the availability of TAVI in our institution, 83 patients were at high risk [defined by logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) >20%]. RESULTS: Among all patients treated for severe AS, the prevalence of high-risk patients was higher in the modern era (12.7 vs 4.9%, P < 0.0001). In the modern era, high-risk patients were treated by TAVI in 89% of cases. Despite similar logistic EuroSCORE (34.9 vs 34%, P = 0.96), the clinical characteristics of these patients have evolved: high-risk patients in the modern era were older (85.3 ± 5.9 vs 78.5 ± 6.5 years, P = 0.0005) and presented more frequently with New York Heart Association class III-IV (92.3 vs 61.1%, P = 0.003), while high-risk patients treated by surgical aortic valve replacement in the pre-TAVI era presented more frequently with a critical preoperative status (33.3 vs 7.7%, P = 0.01), lower left ventricular ejection fraction (41 ± 14 vs 49 ± 15%, P = 0.05) and a history of recent myocardial infarction (27.8 vs 6.1%, P = 0.02). The overall 1-year survival was not different for high-risk patients treated in the pre-TAVI era or in the modern era (61 ± 11 vs 68 ± 6%, P = 0.52). CONCLUSIONS: The availability of TAVI has increased the prevalence of high-risk patients treated for severe AS and changed the clinical features of this kind of patients who were rarely surgically treated before. The 1-year survival was similar between pre-TAVI and modern eras.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Postoperative Complications/epidemiology , Risk Assessment , Adult , Age Factors , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Echocardiography , Female , France/epidemiology , Humans , Male , Middle Aged , Prevalence , Retrospective Studies , Risk Factors , Severity of Illness Index , Survival Rate/trends , Time Factors , Transcatheter Aortic Valve Replacement , Treatment Outcome
6.
N Engl J Med ; 366(18): 1705-15, 2012 May 03.
Article in English | MEDLINE | ID: mdl-22551129

ABSTRACT

BACKGROUND: Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. METHODS: All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. RESULTS: A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (±SD) age was 82.7±7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. CONCLUSIONS: This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.).


Subject(s)
Aortic Valve Stenosis/therapy , Cardiac Catheterization , Heart Valve Prosthesis Implantation/methods , Registries , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Cardiac Catheterization/methods , Female , France/epidemiology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Hemorrhage/epidemiology , Hemorrhage/etiology , Humans , Incidence , Male , Multivariate Analysis , Prospective Studies , Stroke/epidemiology , Stroke/etiology
7.
Circ Cardiovasc Interv ; 5(1): 69-76, S1, 2012 Feb 01.
Article in English | MEDLINE | ID: mdl-22319064

ABSTRACT

BACKGROUND: The value of prehospital initiation of glycoprotein IIb/IIIa inhibitors remains a controversial issue. We sought to investigate whether in-ambulance initiation of abciximab in patients with ST-segment elevation myocardial infarction (STEMI) improves ST-segment elevation resolution (STR) after primary percutaneous coronary intervention (PCI). METHODS AND RESULTS: MISTRAL (Myocardial Infarction with ST-elevation Treated by Primary Percutaneous Intervention Facilitated by Early Reopro Administration in Alsace) is a prospective, randomized, double-blind study. Two hundred and fifty-six patients with acute STEMI were allocated to receive abciximab either in the ambulance (ambulance group, n=127) or in the catheterization laboratory (hospital group, n=129). The primary end point was complete (>70%) STR after PCI. Complete STR was not significantly different between the 2 groups (before PCI, 21.6% versus 15.5%, P=0.28; after PCI, 70.3% versus 65.8%, P=0.49). Thrombolysis In Myocardial Infarction (TIMI) 2 to 3 flow rates before PCI tended to be higher in the ambulance group (46.8% versus 35%, P=0.08) but not after PCI (70.3% versus 65.8%, P=0.49). Slow flow tended to be lower (5.6% versus 13.4%, P=0.07), and distal embolization occurred significantly less often in the ambulance group (8.1% versus 21.1%, P=0.008). One- and 6-month major adverse cardiac event rates were low and similar in both groups. CONCLUSIONS: Early ambulance administration of abciximab in STEMI did not improve either STR or TIMI flow rate after PCI. However, it tended to improve TIMI flow pre-PCI and decreased distal embolization during procedure. Larger studies are needed to confirm these results.


Subject(s)
Angioplasty, Balloon, Coronary , Antibodies, Monoclonal/administration & dosage , Anticoagulants/administration & dosage , Emergency Medical Services , Immunoglobulin Fab Fragments/administration & dosage , Myocardial Infarction/drug therapy , Abciximab , Aged , Antibodies, Monoclonal/adverse effects , Anticoagulants/adverse effects , Double-Blind Method , Electrocardiography , Female , Humans , Immunoglobulin Fab Fragments/adverse effects , Male , Middle Aged , Myocardial Infarction/physiopathology , Myocardial Infarction/surgery , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Prospective Studies , Treatment Outcome
8.
EuroIntervention ; 3(5): 558-65, 2008 Mar.
Article in English | MEDLINE | ID: mdl-19608481

ABSTRACT

AIMS: To evaluate the safety and long-term efficacy of a true dedicated bifurcation bare metal stent (DBS) for the treatment of bifurcation coronary artery lesions. METHODS AND RESULTS: Thirty-four patients were enrolled in this prospective multicentre study. The majority of culprit lesions were located on the left anterior descending artery/diagonal bifurcation (n=19) followed by the distal protected left main (n=7), the left circumflex artery/obtuse marginal (n=4) and the distal right coronary artery/posterior descending artery (n=4). Successful delivery of the DBS stent at the bifurcation site was achieved in 32 patients (94%). Angiographic follow-up at six months was complete in 29 patients (91%). Clinical follow-up was achieved at five years in all DBS patients. There were no cardiac deaths or stent thrombosis. At six months, the MACE rate was 6/32 (19%) and the total binary restenosis rate was 10/29 (34%). MACE at 5 years consisted only in target vessel revascularisation and occurred in eight patients (25%). CONCLUSIONS: The DBS bare metal true bifurcated stent can be delivered successfully and safely in selected bifurcated lesions and has demonstrated long-term efficacy in most patients.

9.
Circulation ; 113(11): 1434-1441, 09 janeiro 2006. tab, graf
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062014

ABSTRACT

Background—The expanding indications for sirolimus-eluting stents (SES) include increasingly complex coronary lesions and populations with clinical profiles markedly different from those of early pivotal controlled studies. The e-Cypher registry monitored the safety and efficacy of SES currently implanted worldwide in daily practice. Methods and Results—Between April 2002 and September 2005, data were collected on 15 157 patients who underwent implantation of 1 SES at 279 medical centers from 41 countries. An independent endpoint review committee adjudicated all reported major adverse cardiovascular events, stent thromboses, and target-vessel revascularizations. Data were managed and analyzed by independent organizations. Predictors of adverse clinical events were identified by regression analysis. The mean age of the sample was 61.7 11.4 years; 77.7% were men, and 28.6% were diabetics. A total of 18 295 lesions were treated (20 503 SES) during the index procedure. The cumulative rates of major adverse cardiovascular events were 1.36% at 30 days, 3.38% at 6 months, and 5.80% at 1 year. The rates of acute, subacute, and late stent thrombosis were 0.13%, 0.56%, and 0.19% of patients, respectively, representing a 12-month actuarial incidence of 0.87%. Insulin-dependent diabetes, acute coronary syndrome at presentation, and advanced age were clinical predictors, whereas TIMI flow grade 3 after the index procedure, treatment of multiple lesions, a prominently calcified or totally occluded target lesion, and multivessel disease were the angiographic or procedural predictors of stent thrombosis at 12 months. Conclusions—This analysis of 1-year data collected by the e-Cypher registry suggests a high degree of safety of SES, with a rate of stent thrombosis similar to that observed in randomized trials.


Subject(s)
Directory/statistics & numerical data , Coronary Disease , Myocardial Revascularization , Stents , Coronary Thrombosis
10.
Circulation ; 113(11): 1434-1441, 09 janeiro 2006. ilus
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062015

ABSTRACT

Background—The expanding indications for sirolimus-eluting stents (SES) include increasingly complex coronary lesions and populations with clinical profiles markedly different from those of early pivotal controlled studies. The e-Cypher registry monitored the safety and efficacy of SES currently implanted worldwide in daily practice. Methods and Results—Between April 2002 and September 2005, data were collected on 15 157 patients who underwent implantation of 1 SES at 279 medical centers from 41 countries. An independent endpoint review committee adjudicated all reported major adverse cardiovascular events, stent thromboses, and target-vessel revascularizations. Data were managed and analyzed by independent organizations. Predictors of adverse clinical events were identified by regression analysis. The mean age of the sample was 61.7 11.4 years; 77.7% were men, and 28.6% were diabetics. A total of 18 295 lesions were treated (20 503 SES) during the index procedure. The cumulative rates of major adverse cardiovascular events were 1.36% at 30 days, 3.38% at 6 months, and 5.80% at 1 year. The rates of acute, subacute, and late stent thrombosis were 0.13%, 0.56%, and 0.19% of patients, respectively, representing a 12-month actuarial incidence of 0.87%. Insulin-dependent diabetes, acute coronary syndrome at presentation, and advanced age were clinical predictors, whereas TIMI flow grade 3 after the index procedure, treatment of multiple lesions, a prominently calcified or totally occluded target lesion, and multivessel disease were the angiographic or procedural predictors of stent thrombosis at 12 months. Conclusions—This analysis of 1-year data collected by the e-Cypher registry suggests a high degree of safety of SES, with a rate of stent thrombosis similar to that observed in randomized trials


Subject(s)
Coronary Artery Disease , Myocardial Revascularization , Stents , Thrombosis
11.
Circulation ; 113(11): 1434-41, 2006 Mar 21.
Article in English | MEDLINE | ID: mdl-16534015

ABSTRACT

BACKGROUND: The expanding indications for sirolimus-eluting stents (SES) include increasingly complex coronary lesions and populations with clinical profiles markedly different from those of early pivotal controlled studies. The e-Cypher registry monitored the safety and efficacy of SES currently implanted worldwide in daily practice. METHODS AND RESULTS: Between April 2002 and September 2005, data were collected on 15,157 patients who underwent implantation of > or =1 SES at 279 medical centers from 41 countries. An independent endpoint review committee adjudicated all reported major adverse cardiovascular events, stent thromboses, and target-vessel revascularizations. Data were managed and analyzed by independent organizations. Predictors of adverse clinical events were identified by regression analysis. The mean age of the sample was 61.7+/-11.4 years; 77.7% were men, and 28.6% were diabetics. A total of 18,295 lesions were treated (20,503 SES) during the index procedure. The cumulative rates of major adverse cardiovascular events were 1.36% at 30 days, 3.38% at 6 months, and 5.80% at 1 year. The rates of acute, subacute, and late stent thrombosis were 0.13%, 0.56%, and 0.19% of patients, respectively, representing a 12-month actuarial incidence of 0.87%. Insulin-dependent diabetes, acute coronary syndrome at presentation, and advanced age were clinical predictors, whereas TIMI flow grade <3 after the index procedure, treatment of multiple lesions, a prominently calcified or totally occluded target lesion, and multivessel disease were the angiographic or procedural predictors of stent thrombosis at 12 months. CONCLUSIONS: This analysis of 1-year data collected by the e-Cypher registry suggests a high degree of safety of SES, with a rate of stent thrombosis similar to that observed in randomized trials.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis/prevention & control , Coronary Stenosis/therapy , Sirolimus/adverse effects , Stents/adverse effects , Aged , Aspirin/therapeutic use , Cause of Death , Clopidogrel , Comorbidity , Coronary Disease/mortality , Coronary Restenosis/surgery , Coronary Restenosis/therapy , Diabetes Mellitus, Type 1/epidemiology , Diabetes Mellitus, Type 2/epidemiology , Drug Implants , Female , Fibrinolytic Agents/therapeutic use , Follow-Up Studies , Humans , Internet , Male , Middle Aged , Myocardial Infarction/epidemiology , Myocardial Infarction/prevention & control , Product Surveillance, Postmarketing , Registries , Risk Factors , Sirolimus/administration & dosage , Sirolimus/therapeutic use , Stents/statistics & numerical data , Thrombosis/epidemiology , Thrombosis/prevention & control , Ticlopidine/analogs & derivatives , Ticlopidine/therapeutic use , United States
12.
Catheter Cardiovasc Interv ; 55(4): 427-33, 2002 Apr.
Article in English | MEDLINE | ID: mdl-11948886

ABSTRACT

Treatment of bifurcation lesions remains a technical challenge. Among 13 stents previously tested in a bench study, the Bestent seemed of particular interest in this indication as it provided good access to the side branch after stent implantation in the main branch associated with a satisfactory coverage of the lesion after kissing balloon inflation. The use of Bestent implanted in the main branch or both branches for treatment of bifurcation lesions involving a side branch > or = 2.2 mm in diameter was prospectively evaluated in a dual-center prospective study with a prospective 6-month clinical follow-up. All angiographic documents were analyzed by an independent corelab (CORISIS). Between 11 September 1997 and 21 February 1998, 96 patients were consecutively included (mean age, 63.7 +/- 11.4 years; 81.3% male; 58.3% with unstable angina and 6.3% acute myocardial infarction). The lesion involved the left anterior descending-diagonal coronary bifurcation in 55% of cases, left circumflex-marginal 23%, posterior descending-postero-lateral 12%, distal left main 6%, and others 4%. The main branch (proximal reference diameter: 3.43 +/- 0.45 mm) was stented in 98% of cases and the side branch (2.72 +/- 0.38 mm) in 38% (both branches in 34% of cases). T-stenting or provisional T-stenting was used in 88% of cases and final kissing balloon inflation was performed in 78% of cases. Procedural success was obtained in 100% of cases in the main branch and 98% in both branches. Major cardiac and cerebral events (MACCE) during hospitalization occurred in 4.2% of cases, non-Q-wave myocardial infarction (MI) in 3.1%, Q-wave MI in 1.0%, repeat PTCA in 2.1%; there were no major access site complication, no emergency coronary artery bypass grafting operation, no death. At 6-month follow-up, total MACCE rate was 14.6% (Q-wave MI, 3.1%; non-Q-wave MI, 3.1%; target vessel revascularization, 9.4%; death, 2.1%). Patients with target vessel revascularization (TVR) had restenosis of both branches in 22.2% of cases, main branch in 22.2%, and side branch in 55.6%. This study shows that using a simple strategy of provisional T-stenting of the side branch in the majority of cases, the Bestent can be used for treating bifurcation lesions with a high rate of success and an acceptable rate of TVR at 6-month follow-up.


Subject(s)
Blood Vessel Prosthesis Implantation , Coronary Disease/surgery , Coronary Vessels/surgery , Stents , Aged , Coronary Angiography , Coronary Disease/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...