Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Diabetes Sci Technol ; 10(4): 939-46, 2016 07.
Article in English | MEDLINE | ID: mdl-26989068

ABSTRACT

This study assesses and demonstrates that CONTOUR® XT-BGMS (CXT-BGMS) complies with the requirements of the German (RiliBÄK) and Swiss (QUALAB) quality control guidelines for point-of-care testing (POCT) and fulfills the ISO15197:2013 accuracy limits criteria under the routine conditions of a hospital point-of care setting. This single-center study was conducted in Switzerland using 105 venous blood samples from hospitalized patients. Each sample was tested in comparison to the hexokinase reference method. Compliance with POCT guidelines was assessed by daily BGMS measurements using control solutions. Accuracy of CXT-BGMS according to ISO limits was 98.41%. All control measurements were within the limits defined by RiliBÄK (within ± 11% of target values and root mean square error [RMSE] within RMSE limits), and QUALAB (within ± 10% of target values).


Subject(s)
Blood Glucose/analysis , Point-of-Care Testing , Humans , Product Surveillance, Postmarketing
2.
J Clin Virol ; 58(3): 535-40, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24041472

ABSTRACT

BACKGROUND: hepatitis C infections are detected by anti-HCV screening tests. Reactive anti-HCV results give no information about the presence or absence of hepatitis C viruses, or of unspecific reactivity. To obtain information about the viral load, HCV RNA measurements, following a reactive anti-HCV result, are performed in well equipped and specialised laboratories. Anti-HCV immunoblots are the only means to exclude non specific reactivity. The measurement of HCV core antigen (HCV-Ag), as an alternative to HCV RNA, is discussed, as it can be analysed on the same instrument as anti-HCV. OBJECTIVES: The detection limit of HCV-Ag is crucial to use it in lieu of HCV RNA, in regard of the different genotypes. A renewed algorithm is proposed to exclude unspecific reactivity of anti-HCV. STUDY DESIGNS: Samples were tested on Architect i2000SR (Abbott) for anti-HCV and HCV-Ag. HCV RNA measurements were obtained by Cobas Ampliprep/Taqman (Roche) or m2000rt(®) (Abbott). RESULTS AND CONCLUSIONS: Comparison between HCV-Ag and HCV RNA from 126 samples of 101 patients with chronic hepatitis C gave linear regression R(2) 0.89, slope 0.885 and intercept -2.258, which were independent of the genotypes. The detection limit of HCV-Ag was between 2.4 and 4.5 Log(10)IU/mL. A renewed algorithm for confirmation of reactive anti-HCV results is proposed: active or resolved hepatitis C infections or false reactivity can be differentiated by sequenced reflex testing due to HCV-Ag, anti-HCV immunoblot and HCV RNA.


Subject(s)
Antigens, Viral/blood , Hepacivirus/isolation & purification , Hepatitis C Antibodies/blood , Hepatitis C, Chronic/diagnosis , Hepatitis C, Chronic/virology , RNA, Viral/blood , Viral Load/methods , Algorithms , Humans , Limit of Detection