Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
AJR Am J Roentgenol ; 212(1): 84-93, 2019 01.
Article in English | MEDLINE | ID: mdl-30299999

ABSTRACT

OBJECTIVE: Previous studies have shown the possibility to reduce radiation dose in abdominal CT by 25-50% without negatively affecting detection of liver lesions. How radiation dose reduction affects characterization of liver metastases is not as well known. The objective of this study was to investigate how different levels of simulated dose reduction affect the detection and characterization of liver lesions, primarily hypovascular metastases. A secondary objective was to analyze the relationship between the lesion size and contrast-to-noise ratio (CNR) and the detection rate. MATERIALS AND METHODS: Thirty-nine patients (19 with metastases and 20 without) were retrospectively selected. The following radiation dose levels (DLs) were simulated: 100% (reference level), 75%, 50%, and 25%. Five readers were asked to mark liver lesions and rate the probability of malignancy on a 5-grade Likert scale. Noninferiority analysis using the jackknife free-response ROC (JAFROC) method was performed as well as direct comparison of detection rates and grades. RESULTS: JAFROC analysis showed noninferior detection and characterization of metastases at DL75 as compared with DL100. However, the number of benign lesions and false-positive localizations rated as "suspected malignancy" was significantly higher at DL75. CONCLUSION: Radiation dose can be reduced by 25% without negatively affecting diagnosis of hypovascular liver metastases. Characterization of benign lesions, however, is impaired at DL75, which may lead to unnecessary follow-up examinations. Finally, increased image noise seems to affect the detection of small lesions to a degree that cannot be explained solely by the reduction in CNR.


Subject(s)
Liver Neoplasms/diagnostic imaging , Radiation Dosage , Radiography, Abdominal/methods , Tomography, X-Ray Computed/methods , Aged , Contrast Media , Female , Humans , Liver Neoplasms/secondary , Male , Middle Aged , Neoplasm Grading , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Reference Standards , Reproducibility of Results , Retrospective Studies
3.
AJR Am J Roentgenol ; 200(2): 383-8, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23345361

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate an abdominal CT protocol in which radiation dose was reduced and i.v. contrast dose increased for young patients and radiation dose was increased and i.v. medium dose decreased for elderly patients. The hypothesis was that these adjustments would result in constant image quality and a reduction in age-specific risk. MATERIALS AND METHODS: Patients were divided into four age groups of 25 patients each: group 1, 16-25 years; group 2, 26-50 years; group 3, 51-75 years; and group 4, older than 75 years. The quality reference tube load ranged from 100 to 300 mAs, and the i.v. contrast dose ranged from 600 to 350 mg I/kg. Group 3 was the reference group. Signal-to-noise and contrast-to-noise ratios for a hypothetical hypovascular liver metastatic lesion were calculated. Subjective image quality was evaluated by visual grading characteristic analysis in which four readers assessed the reproduction of seven image-quality criteria. RESULTS: Radiation dose was reduced 57% in the youngest group, and the i.v. contrast dose was reduced 18% in elderly patients. There were no statistically significant differences between the groups with respect to signal-to-noise and contrast-to-noise ratios. Subjective image quality was graded significantly lower for four criteria in group 1 compared with group 3. No significant difference was found in comparisons of groups 2 (except for one criterion) and 4 with group 3. CONCLUSION: It is possible to balance radiation dose and contrast dose against each other and maintain signal-to-noise and contrast-to-noise ratios. Subjective image quality was affected by increased noise level on the images but was judged acceptable in all groups except the one with the lowest radiation dose.


Subject(s)
Radiation Dosage , Radiography, Abdominal/methods , Tomography, X-Ray Computed/methods , Adolescent , Adult , Age Factors , Aged , Contrast Media/administration & dosage , Female , Humans , Injections, Intravenous , Male , Middle Aged , Models, Theoretical , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL