Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 15(22): 14530-8, 2007 Oct 29.
Article in English | MEDLINE | ID: mdl-19550732

ABSTRACT

A recent advancement was achieved in the integration and miniaturization of a binocular head-worn projection display (HWPD) conceived for fully mobile users. The devised display, referred to as Mobile HWPD (M-HWPD), offers see-through capability through custom-designed, light-weight projection optics and an integrated commercial-off-the-shelf (COTS) retro-reflective screen to display full color stereoscopic rendered images augmenting the real world. Moreover, the light-weight optical device (i.e., approximately 8g per eye) has the ability to project clear images at three different locations within near- or far-field observation depths without loss of image quality. In this paper, we first demonstrate the miniaturization of the optics, the optical performance, and the integration of these components with the retro-reflective screen to produce an M-HWPD prototype. We then show results that demonstrate the feasibility of superimposing computer-generated images on a real outdoor scene with the M-HWPD.

2.
J Opt Soc Am A Opt Image Sci Vis ; 21(6): 901-12, 2004 Jun.
Article in English | MEDLINE | ID: mdl-15191170

ABSTRACT

A theoretical investigation of rendered depth and angular errors, or Albertian errors, linked to natural eye movements in binocular head-mounted displays (HMDs) is presented for three possible eye-point locations: the center of the entrance pupil, the nodal point, and the center of rotation of the eye. A numerical quantification was conducted for both the pupil and the center of rotation of the eye under the assumption that the user will operate solely in either the near field under an associated instrumentation setting or the far field under a different setting. Under these conditions, the eyes are taken to gaze in the plane of the stereoscopic images. Across conditions, results show that the center of the entrance pupil minimizes rendered angular errors, while the center of rotation minimizes rendered position errors. Significantly, this investigation quantifies that under proper setting of the HMD and correct choice of the eye points, rendered depth and angular errors can be brought to be either negligible or within specification of even the most stringent applications in performance of tasks in either the near field or the far field.


Subject(s)
Data Display , Depth Perception/physiology , Equipment Failure Analysis/methods , Fixation, Ocular/physiology , Imaging, Three-Dimensional/instrumentation , Models, Biological , User-Computer Interface , Computer Simulation , Environment , Eye Movements/physiology , Head Protective Devices , Imaging, Three-Dimensional/methods , Online Systems , Reproducibility of Results , Sensitivity and Specificity , Video Recording/instrumentation , Video Recording/methods , Vision, Ocular/physiology
3.
Appl Opt ; 42(1): 97-107, 2003 Jan 01.
Article in English | MEDLINE | ID: mdl-12518828

ABSTRACT

Driven by the need for lightweight head-mounted displays, we present the design of an ultralight and compact projection lens for a head-mounted projective display (HMPD). An HMPD consists of a pair of miniature projection lenses, beam splitters, and miniature displays mounted on the helmet and retroreflective sheeting materials placed strategically in the environment. The HMPD has been proposed recently as an alternative modality for three-dimensional visualization. After demonstrating the concept, building a first-generation custom-designed prototype, and investigating perception issues and application potentials, we designed an ultralight and compact projective lens with a diffractive optical element (DOE), plastic components, and aspheric surfaces for the next-generation prototype. The key contribution here lies in the conception, optimization, and assessment of the projection optics. Thus a brief review of the HMPD technology and related research is followed by a detail discussion of the conception and optimization of the ultralight and high-performance projection optics. The design of the DOE will be particularly described in detail. Finally, the diffraction efficiency of the DOE will be evaluated, and the overall performance of the optics will be assessed in both object space for the optical designer and visual space for possible end-users of the technology.


Subject(s)
Lenses , Equipment Design , Humans , Light , Models, Theoretical , Optics and Photonics , Scattering, Radiation
4.
Stud Health Technol Inform ; 94: 288-94, 2003.
Article in English | MEDLINE | ID: mdl-15455910

ABSTRACT

The authors introduce a tool referred to as the Ultimate Intubation Head (UIH) to train medical practitioners' hand-eye coordination in performing endotracheal intubation with the help of augmented reality methods. In this paper we describe the integration of a deployable UIH and present methods for augmented reality registration of real and virtual anatomical models. The assessment of the 52 degrees field of view optics of the custom-designed and built head-mounted display is less than 1.5 arc minutes in the amount of blur and astigmatism, the two limiting optical aberrations. Distortion is less than 2.5%. Preliminary results of the registration of a physical phantom mandible on its virtual counterpart yields less than 3mm rms. in registration. Finally we describe an approach to distributed visualization where a given training procedure may be visualized and shared at various remote locations. Basic assessments of delays within two scenarios of data distribution were conducted and reported.


Subject(s)
Computer Simulation , Health Personnel/education , Intubation, Intratracheal , Manikins , User-Computer Interface
5.
Appl Opt ; 41(25): 5282-9, 2002 Sep 01.
Article in English | MEDLINE | ID: mdl-12211555

ABSTRACT

The optics of head-mounted displays (HMDs) is designed from the pupil of the eye to the miniature display, and the optics is thus commonly solely assessed in the plane of the miniature display. Such assessment does not provide information that usefully interfaces with task-based performance metrics. We present a comprehensive framework for the assessment of the optics of HMDs in visual space, which applies to nonrotationally symmetric systems as well. Four key measures of visual performance are presented, and macro files were implemented to validate the framework. We illustrate the methods using an Erfle eyepiece.


Subject(s)
Data Display , Head , Optics and Photonics , Space Perception/physiology , User-Computer Interface , Humans , Models, Theoretical
6.
Stud Health Technol Inform ; 85: 121-6, 2002.
Article in English | MEDLINE | ID: mdl-15458071

ABSTRACT

Augmented reality is often used for interactive, three-dimensional visualization within the medical community. To this end, we present the integration of an augmented reality system that will be used to train military medics in airway management. The system demonstrates how a head-mounted projective display can be integrated with a desktop PC to create an augmented reality visualization. Furthermore, the system, which uses a lightweight optical tracker, demonstrates the low cost and the portability of the application.


Subject(s)
Allied Health Personnel/education , Intubation, Intratracheal , Military Medicine/education , Models, Anatomic , User-Computer Interface , Cardiopulmonary Resuscitation/education , Emergency Medical Services , Humans , Microcomputers
SELECTION OF CITATIONS
SEARCH DETAIL