Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
Front Surg ; 10: 1167714, 2023.
Article in English | MEDLINE | ID: mdl-37260597

ABSTRACT

Objectives: We aimed to elucidate the perioperative and short-term clinical outcomes of the Najuta thoracic stent graft system with fenestrations for supra-aortic vessels. Methods: We retrospectively investigated the perioperative and short-term clinical outcomes of 20 patients treated for arch or distal arch aneurysms using the Najuta thoracic stent graft system during the period from May 2019 to February 2023. Results: The technical success rate of the Najuta thoracic stent graft system was 95%. Of the 20 patients, 17 patients (85.0%) underwent concomitant extra-anatomical supra-aortic bypass. Postoperative CT revealed type Ia (n = 2) and type II (n = 3) endoleaks which disappeared on follow-up. The postoperative complications were stroke (n = 2, 10.0%), paraplegia (n = 1, 5.0%), and paraparesis (n = 1, 5.0%). In a very old patient, a blood transfusion was performed from the common iliac artery using the retroperitoneal approach. There were no aorta-related complications such as retrograde type A dissection or distal stent graft-induced new entry. Conclusions: We treated arch or distal arch thoracic aneurysms by inserting a tube-type stent graft as a scaffold on the peripheral site and placing the Najuta thoracic stent graft on the proximal site. By extending the landing zone to Zone 0 and using a low radial force, which is a feature of the Najuta thoracic stent graft system, postoperative bird-beak and aorta-related complications were avoided. The treatment of arch and distal arch aortic aneurysms using the Najuta thoracic stent graft system showed acceptable perioperative and short-term clinical outcomes. Thoracic endovascular aortic repair using the Najuta thoracic stent graft system may be a potential treatment option for arch and distal arch aortic aneurysms, warranting further studies.

2.
Interact Cardiovasc Thorac Surg ; 34(2): 267-273, 2022 01 18.
Article in English | MEDLINE | ID: mdl-34632503

ABSTRACT

OBJECTIVES: The actual incidence of cerebral infarction (CI), including asymptomatic infarction, owing to thoracic endovascular aortic repair (TEVAR) has not been reported in detail. This study was performed to investigate the incidence of post-TEVAR CI by using diffusion-weighted magnetic resonance imaging (DW-MRI) and to determine the risk factors for both symptomatic and asymptomatic CI. METHODS: We examined 64 patients undergoing TEVAR at our institute between April 2017 and November 2020. Aortic atheroma was graded from 1 to 5 by preoperative computed tomography. Cerebral DW-MRIs were conducted 2 days after the procedure to diagnose postoperative CI. RESULTS: A total of 44 new foci were detected by post-interventional cerebral DW-MRI in 22 patients (34.4%). Only one patient developed a symptomatic stroke (1.6%), and TEVAR was successfully completed in all cases. Debranching of the aortic arch and left subclavian artery occlusion with a vascular plug was performed in 19 (29.7%) and 12 (18.8%) patients, respectively. The number of patients with proximal landing zones 0-2 was significantly higher in the CI group than in the non-CI group (68.2% vs 11.9%; P < 0.001). The following risk factors were identified for asymptomatic CI: aortic arch debranching (P < 0.001), left subclavian artery occlusion (P = 0.001) and grade 4/5 aortic arch atheroma (P = 0.048). CONCLUSIONS: Over one-third of the patients examined by cerebral DW-MRI after TEVAR were diagnosed with CI. High-grade atheroma and TEVAR landing in zone 0-2 were found to be positively associated with asymptomatic CI. CLINICAL TRIAL REGISTRATION: 02-014.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/epidemiology , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Cerebral Infarction/diagnostic imaging , Cerebral Infarction/epidemiology , Cerebral Infarction/etiology , Diffusion Magnetic Resonance Imaging/methods , Endovascular Procedures/adverse effects , Humans , Incidence , Retrospective Studies , Risk Factors , Treatment Outcome
3.
Vascular ; 30(1): 38-41, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33522457

ABSTRACT

OBJECTIVES: We report a case of successful thoracic endovascular aortic repair (TEVAR) of chronic type B aortic dissection complicated by disseminated intravascular coagulopathy. METHODS: The patient suffered from chronic type B aortic dissection coexisting with a large false lumen and an intimal tear. He underwent TEVAR with left common carotid-left subclavian artery bypass. RESULTS: The following day, the patient exhibited a bleeding tendency and marked subcutaneous hemorrhage. He had a low fibrinogen level, a low platelet count, and high levels of fibrin dimer product and D-dimer. We diagnosed the condition as disseminated intravascular coagulopathy and administered recombinant human soluble thrombomodulin (rhTM). The patient recovered successfully from disseminated intravascular coagulopathy and was discharged on postoperative day 6. CONCLUSIONS: We successfully treated a patient with chronic type B aortic dissection with a large intimal tear complicated by postoperative disseminated intravascular coagulopathy using TEVAR followed by rhTM administration. rhTM may be considered in patients with large intimal tear and false lumen.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Humans , Male , Retrospective Studies , Thrombomodulin , Treatment Outcome
4.
J Artif Organs ; 25(2): 174-177, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34056668

ABSTRACT

The MitraClip system is used for patients with severe mitral regurgitation (MR) who are at high risk for open surgery. However, some patients need surgical revision for various complications. The acute outcome of MitraClip treatment for atrial functional MR (aFMR) is scarcely reported. Herein, we describe a rare case of an 80-year-old woman treated with a MitraClip for aFMR with mitral annular dilatation and failed leaflet adaptation. The patient suffered from single leaflet device attachment (SLDA) and posterior leaflet injury 3 days posttreatment. The patient successfully underwent mitral valve replacement. The postoperative pulmonary hypertension was markedly improved and the left atrial volume was reduced. A MitraClip should be carefully used for aFMR with mitral annular dilatation and failed leaflet adaptation as it may cause SLDA.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged, 80 and over , Female , Heart Atria , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Postoperative Complications/etiology , Reoperation , Treatment Outcome
5.
Gen Thorac Cardiovasc Surg ; 70(2): 201-203, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34826121

ABSTRACT

A 65-year-old man with unstable angina was transferred to our department for coronary artery bypass grafting (CABG). Preoperative computed tomography indicated a large thrombosis in the left coronary cusp (LCC). CABG concomitant thrombectomy was performed under cardiopulmonary bypass using unfractionated heparin. Although the LCC was filled with a large thrombus, the left coronary artery ostium was not obstructed. The platelet count decreased by 68%, 12 days after starting heparin in the previous hospital. There is a high probability that this patient had HIT which was not recognized before surgery.


Subject(s)
Thrombocytopenia , Thrombosis , Aged , Anticoagulants/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Coronary Artery Bypass , Heparin/adverse effects , Humans , Male , Thrombocytopenia/chemically induced , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/surgery
6.
Gen Thorac Cardiovasc Surg ; 69(7): 1144-1146, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33788168

ABSTRACT

Postcardiotomy cardiogenic shock (PCCS) is associated with considerably high rates of mortality. In PCCS, veno-arterial extracorporeal membrane oxygenation has been used despite the high rates of complications and poor outcome. Since the introduction of Impella CP (Abiomed, Danvers, MA, USA), effective left-ventricular unloading and systemic perfusion could be maintained even in patients with severe PCCS. Herein, we describe the successful treatment of PCCS following combined heart surgery in a patient by Impella CP insertion.


Subject(s)
Cardiac Surgical Procedures , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Cardiac Surgical Procedures/adverse effects , Heart Ventricles , Humans , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy
7.
Vascular ; 29(6): 826-831, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33478338

ABSTRACT

OBJECTIVE: We investigated the outcomes of extended coverage of the descending thoracic aorta by thoracic endovascular aortic repair (TEVAR) for residual chronic type B aortic dissection after type A aortic dissection (TAAD) repair. METHODS: From November 2015 to August 2020, 36 patients underwent extended TEVAR for residual intimal tear after TAAD repair. We specifically investigated the methods and outcomes of this procedure. RESULTS: TEVAR consisted of isolated TEVARs (n = 29), single-vessel debranching TEVAR (6), and two-vessel debranching TEVAR (1). The mean time from TAAD repair to TEVAR was 27 ± 33 months (2-86 months). The TEVAR devices used were Valiant (28 cases), GORETAG (4), Relay plus (2), and TX2 (2). Technical success of TEVAR was 100%. The distal ends of the stent grafts were T 8 (1 case), T 9 (5), T 10 (6), T 11 (9), and T 12 (15), with an average of T 11 ± 1. The average length of hospital stay after TEVAR was 9 ± 3 days (5-17 days). There were no surgical/hospital deaths or complications. The average postoperative follow-up period was 21 ± 15 months without death or reintervention. CONCLUSIONS: The short-term outcomes of extended TEVAR for residual chronic type B aortic dissection after TAAD repair were acceptable without perioperative SCI. Aggressive descending thoracic aorta coverage may prevent aortic events, and extended TEVAR may be a preemptive treatment for the downstream aorta. Mid- to long-term results should be clarified.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Adult , Aged , Aortic Dissection/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Chronic Disease , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Humans , Male , Middle Aged , Retrospective Studies , Stents , Time Factors , Treatment Outcome
8.
Ann Thorac Cardiovasc Surg ; 27(1): 68-70, 2021 Feb 20.
Article in English | MEDLINE | ID: mdl-29899177

ABSTRACT

Spontaneous rupture of the thoracic aorta is rare. We present a 76-year-old man who developed spontaneous rupture of the aortic arch associated with massive periaortic hematoma and hypovolemic shock. Because the site of rupture could not be identified, emergency hybrid endovascular aortic repair to shield a long segment of the aorta was performed according to the extent and density of periaortic hematoma on axial CT scans. His blood pressure improved just after deployment of the endograft. Rapid diagnosis by CT and prompt control of aortic hemorrhage by endografting salvaged this patient. Three-dimensional (3D) volume-rendered CT images are useful for identifying the site of aortic rupture, but may not be available in an emergency.


Subject(s)
Aorta, Thoracic/surgery , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortic Rupture/diagnostic imaging , Aortic Rupture/physiopathology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Emergencies , Endovascular Procedures/instrumentation , Humans , Male , Rupture, Spontaneous , Stents , Treatment Outcome
9.
Ann Vasc Dis ; 12(4): 519-523, 2019 Dec 25.
Article in English | MEDLINE | ID: mdl-31942211

ABSTRACT

Objective: Endograft limb occlusion (ELO) is a complication of endovascular aneurysm repair (EVAR). In this study, we investigated the mechanism and anatomical features of ELO. Materials and Methods: We retrospectively reviewed 227 consecutive patients with abdominal aortic aneurysm who underwent EVAR between 2007 and 2017. We then analyzed the preoperative risk factors and anatomical features of patients with ELO. Results: A total of nine patients had ELO (4.0%). The diameter of the terminal aorta was significantly smaller in patients with ELO than in patients without ELO (18.0 mm vs. 22.3 mm, p=0.039). We measured the diameter of each limb near the terminal aorta. The smaller limb (SL) was occluded in all patients with occlusion. The difference between the larger limb (LL) and the SL (LL-SL) was significantly larger in patients with ELO than in patients without ELO (4.0 mm vs. 1.7 mm, p<0.001). The following were considered risk factors for ELO: younger age, narrow terminal aorta, severe calcification at the terminal aorta, and use of an Endurant device. Conclusion: ELO occurs when the diameter of one side of the stent graft limb is small compared with the diameter of the other side owing to the narrow terminal aorta and calcification.

10.
Article in English | MEDLINE | ID: mdl-29468987

ABSTRACT

Backgroud and Objective: Antithyroid drugs (ATDs) [methylmercaptoimidazole (MMI) and propylthiouracil (PTU) ] are used to treat hyperthyroidism in Graves' disease. The effect of ATDs and reducing agents (mercaptoethanol, dithiothreitol and cysteine) on bovine (b) TSH binding to human (h) and porcine (p) TSH receptor (R) was examined. METHODS AND RESULTS: (1) ATDs was pre-incubated with hTSHR coated tube for 1- 4 h, washed free of ATDs, and then 125I-bTSH binding to hTSHR after 1 h incubation was examined. MMI (10-40 mM) decreased 125I-bTSH binding in a dose-dependent manner and binding decreased proportionally as preincubation time increased from 1 to 4 h. PTU (10mM) slightly decreased binding, When reducing agents were pre-incubated with hTSHR for 2 h, 125I-bTSH binding similarly decreased. (2) Porcine thyroid membrane was pre-incubated with both agents for 2 h. Then, the washed or unwashed membrane was incubated with 125I-bTSH for 1 h. 125I-bTSH binding in both methods decreased. (3) When the effect of ATDs or reducing agents on the biological activity of 125I-bTSH and thyroid stimulating antibody (TSAb) was examined after gel-filtration of 125I-bTSH- and TSAb- treated with both reagents for 1 h, no inactivation was observed. (4) ATDs showed similar reducing action as reducing agents because iodine (I+) was reduced to I- by ATDs. CONCLUSION: ATDs inactivate the TSH-binding site of TSHR by reduction, although ATDs do not inactivate bTSH and TSAb activity. This suggests that TSAb would not stimulate the thyroid due to the inactivation of the TSHR when ATDs are administered to patients with Graves' disease.


Subject(s)
Antithyroid Agents/pharmacology , Methimazole/pharmacology , Propylthiouracil/pharmacology , Receptors, Thyrotropin/antagonists & inhibitors , Thyroid Gland/drug effects , Thyrotropin/antagonists & inhibitors , Animals , Antithyroid Agents/metabolism , Binding Sites , Humans , Immunoglobulins, Thyroid-Stimulating/metabolism , Methimazole/metabolism , Oxidation-Reduction , Propylthiouracil/metabolism , Protein Binding , Receptors, Thyrotropin/metabolism , Sus scrofa , Thyroid Gland/metabolism , Thyrotropin/metabolism
11.
Ann Thorac Cardiovasc Surg ; 24(3): 157-160, 2018 Jun 20.
Article in English | MEDLINE | ID: mdl-29249769

ABSTRACT

An 83-year-old man with aortic arch aneurysm underwent zone 0 thoracic endovascular aortic repair (TEVAR) by the chimney graft technique with two supra-aortic arch debranching grafts and developed subacute type A ascending aortic dissection. We performed emergency open conversion with circulatory arrest under deep hypothermia. The tip of the chimney graft (around the sino-tubular junction in the ascending aorta) was stiff, making it difficult to inspect the lumen and perform anastomosis. Deep hypothermic circulatory arrest and cutting the endograft stents to mobilize the graft were necessary for secure anastomosis.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/etiology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/methods , Circulatory Arrest, Deep Hypothermia Induced , Computed Tomography Angiography , Emergencies , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Humans , Male , Prosthesis Design , Stents , Treatment Outcome
12.
Ann Vasc Dis ; 10(2): 149-151, 2017 Jun 25.
Article in English | MEDLINE | ID: mdl-29034043

ABSTRACT

A 68-year-old man with Marfan syndrome developed de-novo leakage after endovascular aneurysm repair of a Dacron graft. Findings at subsequent reoperation suggested that the rebound force on the endograft generated by marked longitudinal deformation in the Dacron graft may have placed stress on the suture line, leading to partial dehiscence. The Dacron graft seemed to provide a stable proximal landing zone. However, the strong tendency of some endograft devices to return to their original shape may apply stress that affected weakened regions of the native aorta.

13.
J Cardiothorac Surg ; 12(1): 77, 2017 Sep 05.
Article in English | MEDLINE | ID: mdl-28870223

ABSTRACT

BACKGROUND: The original 'candy-plug' technique has been reported to be beneficial for the treatment of residual perfused false lumen in patients with aortic dissection. However, this technique is also associated with several problems, such as narrowing of the true lumen and damage to the flap or vessel wall. Therefore, we modified the procedure to overcome these problems. Here we report a case in which the patient was successfully treated using the modified procedure. CASE PRESENTATION: A 59-year-old man presented with chronic type B aortic dissection with aneurysmal dilatation. The patient had undergone prosthetic graft replacement of the ascending aorta for acute type A aortic dissection 3 years previously and replacement of the descending aorta for residual type B aortic dissection with aneurysmal dilatation 1 year previously. After these procedures, the residual false lumen aneurysm of the distal descending aorta expanded to 57-mm in diameter. Endovascular stent grafting was successfully performed using the modified 'candy-plug' technique with relining of the true lumen and occlusion of the false lumen. The patient was discharged 10 days after the procedure. Follow-up imaging at 1 year showed a completely thrombosed false lumen aneurysm. CONCLUSION: The modified 'candy-plug' technique is useful for treatment of residual type B aortic dissection with aneurysmal dilatation.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Endovascular Procedures/methods , Aortic Dissection/diagnosis , Aortic Aneurysm, Thoracic/diagnosis , Blood Vessel Prosthesis , Chronic Disease , Computed Tomography Angiography , Humans , Imaging, Three-Dimensional , Male , Middle Aged
14.
Ann Thorac Surg ; 104(2): e123-e125, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28734431

ABSTRACT

A 94-year-old woman with rupture of a thoracic aortic aneurysm (rTAA) was referred to us. She previously underwent thoracic endovascular aortic repair and was considered to be at high risk for a conventional open operation. Therefore an endovascular procedure was planned. The proximal landing zone needed to be placed at the ascending aorta to seal a type 1a endoleak. A hybrid operation consisting of supraaortic total debranching on the common femoral artery and endovascular repair was performed. All debranched bypasses were patent and the aneurysm was excluded. The patient regained sufficient ambulatory strength and showed no symptoms of syncope.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis , Endovascular Procedures/methods , Femoral Artery/surgery , Stents , Aged, 80 and over , Aortic Dissection/diagnosis , Aortic Aneurysm, Thoracic/diagnosis , Female , Femoral Artery/diagnostic imaging , Humans , Prosthesis Design , Tomography, X-Ray Computed
15.
Kyobu Geka ; 69(13): 1102-1105, 2016 Dec.
Article in Japanese | MEDLINE | ID: mdl-27909280

ABSTRACT

We report a rare case of cardiac failure for intrapericardial hematoma 11 years after coronary artery bypass grafting. A 59-year-old man was admitted to our hospital with cardiac tamponade. Echocardiography and computed tomography scan showed severe compression of the left ventricle(LV) by a large mass sized about 5×8 cm. Coronary angiography showed total occlusion at circumflex branch (Cx) #11. The mass was diagnosed with intrapericardial hematoma. We performed removal of hematoma in the pericardial cavity, and removed hematoma had 126 g. Considering that the patient had suffered from diabetes mellitus, the localized collection of the hematoma might be explained by possible slow oozing from LV free wall rupture after asymptomatic myocardial infarction at Cx area.


Subject(s)
Cardiac Tamponade/surgery , Coronary Artery Bypass/adverse effects , Heart Failure/surgery , Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/etiology , Heart Failure/diagnostic imaging , Heart Failure/etiology , Humans , Male , Middle Aged , Tomography, X-Ray Computed , Treatment Outcome
16.
Ann Vasc Surg ; 36: 132-138, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27401834

ABSTRACT

OBJECTIVES: This study aimed to analyze the perioperative stroke rate, stroke lesions, outcome, risk factors, and stroke prevention following debranching with thoracic endovascular aortic repair (TEVAR). DESIGN: Retrospective study. METHODS: Between February 2011 and February 2015, 74 consecutive patients underwent debranching with TEVAR at our institution. Of these, the TEVAR proximal landing zone was "zone 0" in 23 patients, "zone 1" in 28, and "zone 2" in 23. Left subclavian artery (LSA) occlusion with coil embolization, balloon occlusion, or vascular plugging was performed in 27 patients. Mean follow-up time was 19.2 months (range 2-52 months). RESULTS: The in-hospital mortality rate was 4.1%. Stroke developed in 7 patients (9.5%), zone 0 in 4 patients, zone 1 in 2, and zone 2 in 1. Six of these patients had stroke lesions arising from the vertebral/basilar artery. Univariate analysis revealed a significant increase in the risk of postoperative stroke in patients with intraluminal atheroma (P = 0.001), those who underwent prior percutaneous transluminal coronary angioplasty or coronary artery bypass graft (P = 0.002), and those with a long operative duration (P = 0.001). Additionally, LSA occlusion significantly decreased the incidence of stroke (P = 0.041). The postsurgical 1- and 2-year cumulative survival rates were 87.3% and 77.0%, respectively, in those without stroke, and 68.6% and 22.9%, respectively, in those with stroke (P = 0.012). CONCLUSIONS: Stroke after debranching with TEVAR was associated with a high mortality. To prevent stroke, careful patient selection and protection of the vertebral artery are important. Prophylactic LSA occlusion at the time of stent-graft deployment might reduce the risk of perioperative stroke.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Stroke/etiology , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Aortic Diseases/physiopathology , Balloon Occlusion , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Embolization, Therapeutic , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Hospital Mortality , Humans , Japan , Male , Middle Aged , Patient Selection , Retrospective Studies , Risk Factors , Stents , Stroke/diagnosis , Stroke/mortality , Stroke/prevention & control , Subclavian Artery/diagnostic imaging , Subclavian Artery/physiopathology , Treatment Outcome
17.
Ann Vasc Surg ; 30: 308.e1-4, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26524134

ABSTRACT

We report a case of hemolytic anemia caused initially by narrowing of a proximal anastomotic site and subsequently by a kinked prosthetic graft after total aortic arch replacement. A 55-year-old man was diagnosed with acute type A aortic dissection by computed tomography (CT). After total aortic arch replacement, hemolytic anemia and renal dysfunction developed. CT detected narrowing of proximal anastomotic site of the graft. Removing the graft and ascending aortic replacement resolved the signs of hemolytic anemia. However, 50 days after the surgery, severe hemolytic anemia developed again. CT revealed a sharply kinked graft. Total arch replacement was again performed to resect the kinked graft. He was discharged on the 24th postoperative day without hemodialysis.


Subject(s)
Anemia, Hemolytic/etiology , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Graft Occlusion, Vascular/complications , Anemia, Hemolytic/diagnosis , Humans , Male , Middle Aged , Reoperation
18.
Ann Vasc Dis ; 8(3): 252-4, 2015.
Article in English | MEDLINE | ID: mdl-26421077

ABSTRACT

An 88-year-old man with severe chest pain and syncope was admitted to our hospital. Contrast-enhanced computed tomography (CT) revealed acute type B aortic dissection with rupture. Considering age and operative risk, we performed emergency thoracic aortic endovascular repair with two-debranching of the left common carotid and left subclavian arteries. To prevent type II endoleak, we used Amplatzer Vascular Plug (AVP) II for left subclavian artery embolization. Postoperative contrast-enhanced CT showed no type II endoleak and rupture site exclusion. As postoperative persistent blood flow to the primary entry or rupture site causes re-rupture, AVP II was crucial in preventing type II endoleak.

19.
Article in English | MEDLINE | ID: mdl-26299889

ABSTRACT

We reported a conversion assay in which thyroid blocking antibody (TBAb) function as thyroid stimulating antibody (TSAb). TBAb-bound porcine thyroid cells (PTC) were made by incubating TBAb(+) serum and PTC for 1 hour. When these TBAb-bound PTC were incubated 4 h with rabbit anti-human (h) IgG antibody (Ab), cAMP production was high, but when incubated with normal rabbit serum (NRS) cAMP production was low. TBAb-Mnoclonal Ab (MoAb) (KI-70) showed similar conversion. However, when TSAb-MoAb(M22) was assayed, anti-hIgG Ab-produced cAMP was lower than NRS-produced cAMP. When a mixture of M22 and KI-70 was assayed, anti-hIgG Ab-produced cAMP was higher than NRS. Thus, it is possible to determine existence of TBAb in TSAb(+)serum when anti-IgG Ab-produced cAMP is higher than NRS-produced cAMP. In this assay TBAb activity in TSAb(+)serum was scored as positive, gray zone and negative when the difference [anti-hIgG Ab-produced cAMP(%)-NRS-produced cAMP(%)] was >100%, 50-100% and <±50%, respectively. In TSAb(+)sera of Graves' patients with no treatment or anti-thyroid therapy, positive TBAb was 9% (3/33 )and 6.9% (5/72), and gray zone was 18 % (6/33) and 25% (18/72), respectively. A low prevelance of TBAb and low TBAb activity (<200% as cAMP) was found in these Graves' patients. A radioisotope treated Graves' patient showed existence of both TSAb and TBAb at 5 months (NRS, 800% cAMP and anti-IgGAb,1,350% cAMP), and highly positive TBAb (NRS, 180% cAMP and anti-hIgG Ab, 3,200% cAMP) at 30 months. This conversion assay is useful principally for TBAb determination but is also useful for TBAb determination in TSAb(+)serum.


Subject(s)
Graves Disease/blood , Hypothyroidism/blood , Immunoglobulins, Thyroid-Stimulating/blood , Animals , Antibodies, Monoclonal/analysis , Antibodies, Monoclonal/metabolism , Autoimmunity , Cells, Cultured , Cyclic AMP/metabolism , Disease Progression , Female , Graves Disease/immunology , Graves Disease/metabolism , Graves Disease/physiopathology , Humans , Hypothyroidism/immunology , Hypothyroidism/metabolism , Hypothyroidism/physiopathology , Immunoglobulins, Thyroid-Stimulating/analysis , Immunoglobulins, Thyroid-Stimulating/biosynthesis , Indicators and Reagents/analysis , Indicators and Reagents/metabolism , Middle Aged , Reproducibility of Results , Sus scrofa , Thyroid Gland/cytology , Thyroid Gland/immunology , Thyroid Gland/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...