Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Publication year range
1.
Nephrol Ther ; 18(7): 634-642, 2022 Dec.
Article in French | MEDLINE | ID: mdl-36216731

ABSTRACT

BACKGROUND: The detection and correction of iron deficiency are essential for the treatment of anemia in chronic hemodialysis patients. The aim of our study was to assess the ability of serum iron to predict hemoglobin response to intravenous iron supplementation in hemodialysis patients. METHODS: It is a retrospective study in 91 hemodialysis patients during 2016 at Clermont-Ferrand University Hospital for whom intravenous iron supplementation had been started. A responder patient was defined as an increase in hemoglobin greater than or equal to 1 g/dL/month and/or a decrease in the dose of erythropoiesis stimulating agent after two months of iron supplementation. RESULTS: In responding patients, serum iron was significantly lower (6.7 ± 2.7 µmol/L) compared to non-responding patients (8.9±2.9 µmol/L; P<0.001). The positive response to iron supplementation was significantly associated with low serum iron (odds ratio = 0.58 [0.42-0.81]; P=0.002) in a logistic regression model taking into account ferritin, transferrin saturation coefficient, dose variation monthly iron and erythropoiesis stimulating agent and the duration of dialysis. The area under the receiver operating characteristic curve of serum iron, ferritin and transferrin saturation coefficient to predict the response to iron supplementation were 0.72, 0.51 and 0.64, respectively (serum iron versus ferritin [P=0.006] and serum iron versus transferrin saturation coefficient [P=0.04]). The sensitivity for serum iron below 7.5 µmol/L was better than that for ferritin below 86 ng/mL (P<0.001) and the specificity for serum iron below 7.5 µmol/L was better than that for TSC less than 19% (P=0.02). CONCLUSION: Serum iron below 7.5 µmol/L can predict the success of the response to iron supplementation in chronic hemodialysis patients.


Subject(s)
Anemia, Iron-Deficiency , Hematinics , Kidney Failure, Chronic , Humans , Hematinics/therapeutic use , Iron/therapeutic use , Retrospective Studies , Transferrin/analysis , Transferrin/therapeutic use , Renal Dialysis/adverse effects , Hemoglobins/analysis , Ferritins , Anemia, Iron-Deficiency/drug therapy , Anemia, Iron-Deficiency/etiology , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/therapy
3.
Kidney Int Rep ; 5(7): 1000-1006, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32647757

ABSTRACT

INTRODUCTION: The last decade has seen a steady increase worldwide in the prevalence of end-stage renal disease (ESRD). Hemodialysis is the major modality of renal replacement therapy (RRT) in 70% to 90% of patients, who require well-functioning vascular access for this procedure. The recommended access for hemodialysis is an arteriovenous fistula or a vascular graft. However, recourse to central venous catheters remains essential for patients whose chronic renal disease is diagnosed at the end stage or in whom an arteriovenous fistula cannot be created or maintained. Tunneled dialysis catheter (TDC) exposure can induce venous stenosis and occlusions and can result in superior vena cava syndrome and/or vascular access loss. Exhaustion of conventional vascular accesses is 1 of the greatest challenges that nephrologists and patients have to face. Several unconventional salvage-therapy routes for TDC placement in patients with exhausted upper body venous access have been reported in the literature. METHODS: We report 2 new cases of intra-atrial TDC placement for patients with exhausted vascular access and perform a meta-analysis of cases from the literature. RESULTS: A total of 51 patients were included. The TDC was inserted by a cardiovascular surgeon in all cases. At the end of follow-up, 75% patients were alive. The median survival time was 25 months. Survival time of hemodialysis patients with intra-atrial TDC was lower than that observed with conventional TDC. CONCLUSIONS: This unconventional technique is safe and functional for hemodialysis patients with exhausted venous access. Atrial vascular access for TDC placement is salvage therapy and is therefore potentially lifesaving.

SELECTION OF CITATIONS
SEARCH DETAIL