Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
J Neurosurg ; : 1-8, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701528

ABSTRACT

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

2.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38483647

ABSTRACT

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Treatment Outcome , Intracranial Aneurysm/surgery , Intracranial Aneurysm/etiology , Embolization, Therapeutic/adverse effects , Propensity Score , Retrospective Studies , Cohort Studies , Endovascular Procedures/adverse effects
3.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37862717

ABSTRACT

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Treatment Outcome , Retrospective Studies , Stents
4.
Transl Stroke Res ; 2023 May 11.
Article in English | MEDLINE | ID: mdl-37165289

ABSTRACT

The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.

5.
J Neurointerv Surg ; 15(9): 844-850, 2023 Sep.
Article in English | MEDLINE | ID: mdl-35868856

ABSTRACT

BACKGROUND: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. METHODS: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. RESULTS: The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. CONCLUSION: There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Treatment Outcome , Endovascular Procedures/methods , Retrospective Studies , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/surgery , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Embolization, Therapeutic/methods
6.
J Neurointerv Surg ; 15(6): 558-565, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35483912

ABSTRACT

BACKGROUND: The Woven EndoBridge (WEB) device has Food and Drug Administration approval for treatment of wide-necked intracranial bifurcation aneurysms. The WEB device has been shown to result in adequate occlusion in bifurcation aneurysms overall, but its usefulness in the individual bifurcation locations has been evaluated separately only in few case series, which were limited by small sample sizes. OBJECTIVE: To compare angiographic and clinical outcomes after treatment of bifurcation aneurysms at various locations, including anterior communicating artery (AComA), anterior cerebral artery (ACA) bifurcation distal to AComA, basilar tip, internal carotid artery (ICA) bifurcation, and middle cerebral artery (MCA) bifurcation aneurysms using the WEB device. METHODS: A retrospective cohort analysis was conducted at 22 academic institutions worldwide to compare treatment outcomes of patients with intracranial bifurcation aneurysms using the WEB device. Data include patient and aneurysm characteristics, procedural details, angiographic and functional outcomes, and complications. RESULTS: A total of 572 aneurysms were included. MCA (36%), AComA (35.7%), and basilar tip (18.9%) aneurysms were most common. The rate of adequate aneurysm occlusion was significantly higher for basilar tip (91.6%) and ICA bifurcation (96.7%) aneurysms and lower for ACA bifurcation (71.4%) and AComA (80.6%) aneurysms (p=0.04). CONCLUSION: To our knowledge, this is the most extensive study to date that compares the treatment of different intracranial bifurcation aneurysms using the WEB device. Basilar tip and ICA bifurcation aneurysms showed significantly higher rates of aneurysm occlusion than other locations.


Subject(s)
Carotid Artery Diseases , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Retrospective Studies , Treatment Outcome , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Carotid Artery Diseases/therapy
7.
Transl Stroke Res ; 14(4): 455-464, 2023 08.
Article in English | MEDLINE | ID: mdl-36066701

ABSTRACT

Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011-2015 (N = 66), 2016-2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020-2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Female , Middle Aged , Male , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Treatment Outcome , Retrospective Studies
9.
Interv Neuroradiol ; : 15910199221149080, 2022 Dec 29.
Article in English | MEDLINE | ID: mdl-36579794

ABSTRACT

Background: First-pass efficacy (FPE) has been established as an important predictor of favorable functional outcomes after endovascular thrombectomy (ET) in anterior circulation strokes. In this retrospective cohort study, we investigate predictors and clinical outcomes of FPE in posterior circulation strokes (pcAIS). Methods: The Stroke Thrombectomy and Aneurysm Registry database was used to identify pcAIS patients who achieved FPE. Their baseline characteristics and outcomes were compared with the non-FPE group. The primary outcome was a 90-day modified Rankin Scale (mRS) of 0-3. Univariate (UVA) and multivariate (MVA) analyses were done to evaluate predictors of FPE. Safety outcomes included distal emboli, vessel rupture, symptomatic intracranial hemorrhage, and mortality. Results: Of 359 patients, 179 (50%) achieved FPE. Clot burden, occlusion site, and ET technique-related variables were similar between the two groups except for shorter procedure time with FPE. The primary outcome was significantly better with FPE (56.4% vs. 32.8%, p < 0.001). Complications were similar except for a higher rate of distal emboli in non-FPE group (11.1% vs. 3.2%, p = 0.032). Atrial fibrillation (Afib) had increased odds (aOR: 2.06, 95% CI; 1.24, 3.4, p = 0.005) and prior ischemic stroke had decreased odds (aOR: 0.524, 95% CI; 0.28, 0.97, p = 0.04) of FPE. Afib was the only independent predictor of FPE on MVA (1.94, 95% CI; 1.1, 3.43, p = 0.022). Conclusions: Higher rate of FPE in Afib-related pcAIS could possibly be explained by the differences in clot composition and degree of in-situ atherosclerotic disease burden. Future studies are warranted to explore the relationship of clot composition with ET outcomes.

10.
Front Pediatr ; 10: 976060, 2022.
Article in English | MEDLINE | ID: mdl-36245731

ABSTRACT

Introduction: Understanding outcomes after Vein of Galen malformation (VOGM) embolization has been limited by small sample size in reported series and predominantly single center studies. To address these limitations, we perform an individual-participant meta-analysis (IPMA) to identify risk factors associated with all-cause mortality and clinical outcome after VOGM endovascular embolization. Methods: We performed a systematic review and IPMA of VOGM endovascular outcomes according to PRISMA guidelines. Individual patient characteristics including demographic, intra/post-operative adverse events, treatment efficacy (partial or complete occlusion), and clinical outcome were collected. Mixed-effects logistic regression with random effects modeling and Bonferroni correction was used (p ≤ 0.003 threshold for statistical significance). The primary and secondary outcomes were all-cause mortality and poor clinical outcome (moderate/severe developmental delay or permanent disabling injury), respectively. Data are expressed as (mean ± standard deviation (SD)) or (odds ratio (OR), 95% confidence interval (CI), I 2, p-value). Results: Thirty-five studies totaling 307 participants quantifying outcomes after endovascular embolization for VOGM were included. Follow up time was 42 (±57) months. Our analysis contained 42% neonates (<1 month) at first embolization, 45% infants (1 month ≤2 years), and 13% children (>2 years). Complete occlusion was reported in 48% of participants. Overall all-cause mortality was 16%. Overall, good clinical outcome was achieved in 68% of participants. First embolization as a neonate [OR = 6.93; 95% CI (1.99-24.08); I 2 < 0.01; p < 0.001] and incomplete embolization [OR = 10.87; 95% CI (1.86-63.55); I 2 < 0.01; p < 0.001] were associated with mortality. First embolization as a neonate [OR = 3.24; 95% CI (1.47-7.15); I 2 < 0.01; p < 0.001], incomplete embolization [OR = 5.26; 95% CI (2.06-13.43); I 2 < 0.01; p < 0.001], and heart failure at presentation [OR = 3.10; 95% CI (1.03-9.33); I 2 < 0.01; p = 0.002] were associated with poor clinical outcomes. Sex, angioarchitecture of lesion, embolization approach (transvenous vs. transarterial), and single or multistage embolization were not associated with mortality or clinical outcome. Conclusions: We identify incomplete VOGM embolization independently associated with mortality and poor clinical outcome. While this study provides the highest level of evidence for VOGM embolization to date, prospective multicenter studies are needed to understand the optimal treatment strategies, outcomes, and natural history after VOGM embolization.

11.
Radiology ; 304(2): 372-382, 2022 08.
Article in English | MEDLINE | ID: mdl-35438564

ABSTRACT

Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the treatment of sidewall aneurysms, with promising outcomes. Purpose To compare the angiographic and clinical outcomes of the WEB device for the treatment of sidewall aneurysms compared with the treatment of bifurcation aneurysms. Materials and Methods A retrospective review of the WorldWideWEB Consortium, a synthesis of retrospective databases spanning from January 2011 to June 2021 at 22 academic institutions in North America, South America, and Europe, was performed to identify patients with intracranial aneurysms treated with the WEB device. Characteristics and outcomes were compared between bifurcation and sidewall aneurysms. Propensity score matching (PSM) was used to match by age, pretreatment ordinal modified Rankin Scale score, ruptured aneurysms, location of aneurysm, multiple aneurysms, prior treatment, neck, height, dome width, daughter sac, and incorporated branch. Results A total of 683 intracranial aneurysms were treated using the WEB device in 671 patients (median age, 61 years [IQR, 53-68 years]; male-to-female ratio, 1:2.5). Of those, 572 were bifurcation aneurysms and 111 were sidewall aneurysms. PSM was performed, resulting in 91 bifurcation and sidewall aneurysms pairs. No significant difference was observed in occlusion status at last follow-up, deployment success, or complication rates between the two groups. Conclusion No significantly different outcomes were observed following the off-label use of the Woven EndoBridge, or WEB, device for treatment of sidewall aneurysms compared with bifurcation aneurysms. The correct characterization of the sidewall aneurysm location, neck angle, and size is crucial for successful treatment and lower retreatment rate. © RSNA, 2022 See also the editorial by Hetts in this issue.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Aneurysm, Ruptured/therapy , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Female , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Male , Middle Aged , Retrospective Studies , Treatment Outcome
12.
J Neurosurg ; : 1-8, 2022 Feb 04.
Article in English | MEDLINE | ID: mdl-35120326

ABSTRACT

OBJECTIVE: Transradial access (TRA) is commonly utilized in neurointerventional procedures. This study compared the technical and clinical outcomes of the use of TRA versus those of transfemoral access (TFA) for intracranial aneurysm embolization with the Woven EndoBridge (WEB) device. METHODS: This is a secondary analysis of the Worldwide WEB Consortium, which comprises multicenter data related to adult patients with intracranial aneurysms who were managed with the WEB device. These aneurysms were categorized into two groups: those who were treated with TRA or TFA. Patient and aneurysm characteristics and technical and clinical outcomes were compared between groups. Propensity score matching (PSM) was used to match groups according to the following baseline characteristics: age, sex, subarachnoid hemorrhage, aneurysm location, bifurcation aneurysm, aneurysm with incorporated branch, neck width, aspect ratio, dome width, and elapsed time since the last follow-up imaging evaluation. RESULTS: This study included 682 intracranial aneurysms (median [interquartile range] age 61.3 [53.0-68.0] years), of which 561 were treated with TFA and 121 with TRA. PSM resulted in 65 matched pairs. After PSM, both groups had similar characteristics, angiographic and functional outcomes, and rates of retreatment, thromboembolic and hemorrhagic complications, and death. TFA was associated with longer procedure length (median 96.5 minutes vs 72.0 minutes, p = 0.006) and fluoroscopy time (28.2 minutes vs 24.8 minutes, p = 0.037) as compared with TRA. On the other hand, deployment issues were more common in those treated with TRA, but none resulted in permanent complications. CONCLUSIONS: TRA has comparable outcomes, with shorter procedure and fluoroscopy time, to TFA for aneurysm embolization with the WEB device.

13.
Stroke ; 53(2): e47-e49, 2022 02.
Article in English | MEDLINE | ID: mdl-34915737
14.
Neurosurgery ; 89(6): 1112-1121, 2021 11 18.
Article in English | MEDLINE | ID: mdl-34624100

ABSTRACT

BACKGROUND: Open surgery has traditionally been preferred for the management of bifurcation middle cerebral artery (MCA) aneurysms. Flow diverting stents present a novel endovascular strategy for aneurysm treatment. OBJECTIVE: To add to the limited literature describing the outcomes and complications in the use of flow diverters for the treatment of these complex aneurysms. METHODS: This is a multicenter retrospective review of MCA bifurcation aneurysms undergoing flow diversion. We assessed post-treatment radiological outcomes and both thromboembolic and hemorrhagic complications. RESULTS: We reviewed the outcomes of 54 aneurysms treated with flow diversion. Four (7.4%) of the aneurysms had a history of rupture (3 remote and 1 acute). Fourteen (25.9%) of the aneurysms already underwent either open surgery or coiling prior to flow diversion. A total of 36 out of the 45 aneurysms (80%) with available follow-up data had adequate aneurysm occlusion with a median follow-up time of 12 mo. There were no hemorrhagic complications but 16.7% (9/54) had thromboembolic complications. CONCLUSION: Flow diverting stents may be a viable option for the endovascular treatment of complex bifurcation MCA aneurysms. However, compared to published series on the open surgical treatment of this subset of aneurysms, flow diversion has inferior outcomes and are associated with a higher rate of complications.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Cerebral Angiography , Cohort Studies , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Retrospective Studies , Stents , Treatment Outcome
15.
World Neurosurg ; 122: 613-619, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30481628

ABSTRACT

BACKGROUND: Chronic subdural hematoma is a very common neurosurgical condition. Although conventional surgical methods, such as burr hole irrigation, have been the mainstay of treatment, middle meningeal artery (MMA) embolization has emerged as a promising adjunctive or alternative treatment. The aim of this article was to present a meta-analysis and systematic review of this topic. METHODS: A literature search using keywords "chronic subdural hematoma," "chronic subdural hemorrhage," "refractory subdural hematoma," "refractory subdural hemorrhage," and "middle meningeal artery embolization" was conducted through October 2018. Outcome variables of hematoma recurrence, surgical complications, and modified Rankin Scale score were analyzed and compared between MMA embolization and conventional surgery cohorts. RESULTS: Three double-arm studies comparing embolization and conventional surgery groups and 6 single-arm case series were identified and analyzed. Hematoma recurrence rate was significantly lower in the embolization group compared with conventional treatment group (2.1% vs. 27.7%; odds ratio = 0.087; 95% confidence interval, 0.026-0.292; P < 0.001; I2 = 0%); surgical complication rates were similar between groups (2.1% vs. 4.4%; odds ratio = 0.563; 95% confidence interval, 0.107-2.96; P = 0.497; I2 = 27.5%). Number of patients with modified Rankin Scale score >2 in the embolization (12.5%) versus conventional treatment (9.1%) group showed no statistical difference (P = 0.689). A composite hematoma recurrence rate of 3.6% was found after summing the 6 case series. Composite recurrence and complication rates in the embolization cohorts of the double-arm studies and the case series were lower than literature values for conventional surgical treatments. CONCLUSIONS: MMA embolization is a promising treatment for chronic subdural hematoma. Future randomized clinical trials are needed.


Subject(s)
Antifibrinolytic Agents/administration & dosage , Embolization, Therapeutic/methods , Hematoma, Subdural, Chronic/therapy , Meningeal Arteries , Craniotomy/methods , Hematoma, Subdural, Chronic/diagnostic imaging , Humans , Meningeal Arteries/diagnostic imaging , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...