Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 270
Filter
1.
Abdom Radiol (NY) ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38916617

ABSTRACT

OBJECTIVE: To assess the value of material density (MD) images generated from a rapid kilovoltage-switching dual-energy CT (rsDECT) in early detection of peritoneal carcinomatosis (PC). MATERIALS AND METHODS: Thirty patients (60 ± 13 years; 24 women) with PC detected on multiple abdominal DECT scans were included. Four separate DECTs with varying findings of PC from each patient were used for qualitative/quantitative analysis, resulting in a total of 120 DECT scans (n = 30 × 4). Three radiologists independently reviewed DECT images (65 keV alone and 65 keV + MD) for diagnosis of PC (diagnostic confidence, lesion conspicuity, sharpness/delineation and image quality) using a 5-point Likert scale. Quantitative estimation of contrast-to-noise ratio (CNR) was done. Wilcoxon signed-rank test and Odds ratio calculation were used to compare between the two protocols. Inter-observer agreement was evaluated using Kappa coefficient analysis. P values < 0.05 were considered statistically significant. RESULTS: 65 keV + MD images showed a slightly higher sensitivity (89%[95%CI:84,92]) for PC detection compared with 65 keV images alone without statistical significance (84%[95%CI:78,88], p = 0.11) with the experienced reader showing significant improvement (98%[95%CI:93,100] vs. 90%[95%CI:83,94], p = 0.02). On a per-patient basis, use of MD images allowed earlier diagnosis for PC in an additional 13-23% of patients. On sub-group analysis, earlier diagnosis of PC was particularly beneficial in patients with BMI ≤ 29.9 kg/m2. 65 keV + MD images showed higher diagnostic confidence, lesion conspicuity, and lesion sharpness for the experienced reader (p < 0.001). CNR was higher in MD images (1.7 ± 0.5) than 65 keV images (0.1 ± 0.02, p < 0.001). All readers showed moderate interobserver agreement for determining PC by both protocols (κ = 0.58 and κ = 0.47). CONCLUSION: MD images allow earlier and improved detection of PC with the degree of benefit varying based on reader experience and patient body habitus.

2.
Dtsch Arztebl Int ; 121(6): 205, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38666682
3.
Eur Radiol ; 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38189979

ABSTRACT

OBJECTIVES: To investigate intra-patient variability of iodine concentration (IC) between three different dual-energy CT (DECT) platforms and to test different normalization approaches. METHODS: Forty-four patients who underwent portal venous phase abdominal DECT on a dual-source (dsDECT), a rapid kVp switching (rsDECT), and a dual-layer detector platform (dlDECT) during cancer follow-up were retrospectively included. IC in the liver, pancreas, and kidneys and different normalized ICs (NICPV:portal vein; NICAA:abdominal aorta; NICALL:overall iodine load) were compared between the three DECT scanners for each patient. A longitudinal mixed effects analysis was conducted to elucidate the effect of the scanner type, scan order, inter-scan time, and contrast media amount on normalized iodine concentration. RESULTS: Variability of IC was highest in the liver (dsDECT vs. dlDECT 28.96 (14.28-46.87) %, dsDECT vs. rsDECT 29.08 (16.59-62.55) %, rsDECT vs. dlDECT 22.85 (7.52-33.49) %), and lowest in the kidneys (dsDECT vs. dlDECT 15.76 (7.03-26.1) %, dsDECT vs. rsDECT 15.67 (8.86-25.56) %, rsDECT vs. dlDECT 10.92 (4.92-22.79) %). NICALL yielded the best reduction of IC variability throughout all tissues and inter-scanner comparisons, yet did not reduce the variability between dsDECT vs. dlDECT and rsDECT, respectively, in the liver. The scanner type remained a significant determinant for NICALL in the pancreas and the liver (F-values, 12.26 and 23.78; both, p < 0.0001). CONCLUSIONS: We found tissue-specific intra-patient variability of IC across different DECT scanner types. Normalization mitigated variability by reducing physiological fluctuations in iodine distribution. After normalization, the scanner type still had a significant effect on iodine variability in the pancreas and liver. CLINICAL RELEVANCE STATEMENT: Differences in iodine quantification between dual-energy CT scanners can partly be mitigated by normalization, yet remain relevant for specific tissues and inter-scanner comparisons, which should be taken into account at clinical routine imaging. KEY POINTS: • Iodine concentration showed the least variability between scanner types in the kidneys (range 10.92-15.76%) and highest variability in the liver (range 22.85-29.08%). • Normalizing tissue-specific iodine concentrations against the overall iodine load yielded the greatest reduction of variability between scanner types for 2/3 inter-scanner comparisons in the liver and for all (3/3) inter-scanner comparisons in the kidneys and pancreas, respectively. • However, even after normalization, the dual-energy CT scanner type was found to be the factor significantly influencing variability of iodine concentration in the liver and pancreas.

4.
Fam Pract ; 41(2): 86-91, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-37672297

ABSTRACT

BACKGROUND: The burden of documentation in the electronic medical record has been cited as a major factor in provider burnout. The aim of this study was to evaluate the association between ambient voice technology, coupled with natural language processing and artificial intelligence (DAX™), on primary care provider documentation burden and burnout. METHODS: An observational study of 110 primary care providers within a community teaching health system. The primary objectives were to determine the association between DAX™ usage and provider burnout scores on the Oldenburg Burnout Inventory (OLBI) as well as the effect on documentation time per patient encounter (minutes). RESULTS: The completion rate for the survey was 75% (83/110) and high DAX™ use (>60% of encounters) was seen in 28% of providers (23/83). High DAX™ use was associated with significantly less burnout on the OLBI disengagement sub-score (MD [Mean Difference] -2.1; 95% confidence interval [CI] -3.8 to -0.4) but not the OLBI disengagement sub-score (-1.0; 95% CI -2.9 to 1.0) or total score (MD -3.0; 95% CI -6.4 to 0.3). Nineteen providers with high implementation of DAX™ had pre and postimplementation data on documentation time per encounter. After DAX™ implementation average documentation time in notes per encounter was significantly reduced by 28.8% (1.8 min; 95% CI 1.4-2.2). CONCLUSIONS: The use of ambient voice technology during patient encounters was associated with significantly reduced documentation burden and primary care provider disengagement but not total provider burnout scores.


Subject(s)
Artificial Intelligence , Burnout, Professional , Humans , Burnout, Psychological , Documentation , Primary Health Care
5.
Curr Protoc ; 3(5): e753, 2023 May.
Article in English | MEDLINE | ID: mdl-37166214

ABSTRACT

Whole genome and whole transcriptome sequencing require orders of magnitude more of starting nucleic acid than what is found in single cells or other extremely limited samples. High fidelity amplification of this minute amount of nucleic acids is essential to overcome the limitations caused by the low input, degradation and contamination, and to ensure a sufficient amount of DNA for preparation of high complex and high quality next-generation sequencing (NGS) libraries. Recent technical advances in multiple displacement amplification (MDA) enable studies of rare cell types, heterogeneity of body fluids, tissues, environmental samples, and organisms that cannot be cultured. Several strategies for amplification of limiting amounts of nucleic acid have been described, with PCR being popular. However, PCR-based methods result in high error rates, lower library complexity, and lower coverage uniformity. In this article, a HiFi MDA is used to accurately amplify the limited material and to allow library preparation starting from high input, while reducing PCR cycling to achieve sufficient library yields. This article describes a complete workflow from cells and small quantities of DNA or RNA to NGS libraries for Illumina sequencing instruments. © 2023 QIAGEN GmbH. Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Whole genome amplification from single cells Support Protocol 1: PicoGreen™ quantification of MDA amplified DNA Support Protocol 2: Purification of amplified DNA after MDA Basic Protocol 2: Whole transcriptome amplification from single cells Alternate Protocol: Whole transcriptome amplification from purified RNA Basic Protocol 3: Enrichment of complete small genomes using target-specific primers in MDA Basic Protocol 4: Complete viral RNA amplification using target-specific primers in MDA Basic Protocol 5: Enzymatic fragmentation and adapter ligation of MDA amplified material Basic Protocol 6: Normalization of library concentration using magnetic beads.


Subject(s)
RNA , Transcriptome , Transcriptome/genetics , Workflow , DNA , High-Throughput Nucleotide Sequencing/methods
6.
Abdom Radiol (NY) ; 48(6): 2167-2195, 2023 06.
Article in English | MEDLINE | ID: mdl-36933024

ABSTRACT

Infarcts and ischemia of abdominal organs may present with acute abdominal pain, and early diagnosis is crucial to prevent morbidity and mortality. Unfortunately, some of these patients present in poor clinical conditions to the emergency department, and imaging specialists are crucial for optimal outcomes. Although the radiological diagnosis of abdominal infarcts is often straightforward, it is vital to use the appropriate imaging modalities and correct imaging techniques for their detection. Additionally, some non-infarct-related abdominal pathologies may mimic infarcts, cause diagnostic confusion, and result in delayed diagnosis or misdiagnosis. In this article, we aimed to outline the general imaging approach, present cross-sectional imaging findings of infarcts and ischemia in several abdominal organs, including but not limited to, liver, spleen, kidneys, adrenals, omentum, and intestinal segments with relevant vascular anatomy, discuss possible differential diagnoses and emphasize important clinical/radiological clues that may assist radiologists in the diagnostic process.


Subject(s)
Abdomen, Acute , Abdomen , Humans , Abdomen, Acute/diagnostic imaging , Abdomen, Acute/etiology , Diagnostic Imaging/adverse effects , Abdominal Pain , Infarction/diagnostic imaging , Ischemia/diagnostic imaging , Ischemia/complications
7.
Cureus ; 15(1): e33837, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36819383

ABSTRACT

Background Currently, there are no tests that have been proven to be capable of rating an individual's grip force measurement as sincere or insincere. However, different parameters have been found to vary in grip force testing for maximal versus submaximal effort. A novel data analysis and processing approach might be key to improving these measurements. This study explores the use of a machine learning (ML) algorithm as a means to more accurately determine the sincerity or insincerity of grip force testing. The ML algorithm compares the hand's load distribution pattern with the information generated using conventional statistical methods. Methodology This study uses manugraphy data collected as part of a previous investigation that analyzed load distribution patterns of the right and left hands of 54 healthy subjects. The subjects underwent grip force testing using maximal or submaximal effort, and the percentage contributions of each of the seven defined anatomical areas of the hand were calculated with respect to the total load applied. The predictions based on the load distribution and its use for rating individual grip force measurements as sincere or insincere were compared with the results of conventional statistical methods (thresholds for a bi-manual area-to-area comparison) and an ML algorithm. Results Based on an area-to-area comparison, our method achieved a sensitivity of 54% and a specificity of 78% to detect insincere effort. A predictive ML model developed using these data was capable of recognizing submaximal effort based on the hand's load distribution pattern, determining a sensitivity of 94% and a specificity of 99%. Conclusions Compared to conventional methods, the use of an ML algorithm considerably improved the validity of manugraphy results in discerning the sincerity or insincerity of grip effort.

8.
Ann Surg ; 277(4): e893-e899, 2023 04 01.
Article in English | MEDLINE | ID: mdl-35185121

ABSTRACT

OBJECTIVE: To compare positron emission tomography (PET)/magnetic resonance imaging (MRI) to the standard of care imaging (SCI) for the diagnosis of peritoneal carcinomatosis (PC) in primary abdominopelvic malignancies. SUMMARY BACKGROUND DATA: Identifying PC impacts prognosis and management of multiple cancer types. METHODS: Adult subjects were prospectively and consecutively enrolled from April 2019 to January 2021. Inclusion criteria were: 1) acquisition of whole-body contrast-enhanced (CE) 18F-fluorodeoxyglucose PET/MRI, 2) pathologically confirmed primary abdominopelvic malignancies. Exclusion criteria were: 1) greater than 4 weeks interval between SCI and PET/MRI, 2) unavailable follow-up. SCI consisted of whole-body CE PET/computed tomography (CT) with diagnostic quality CT, and/or CE-CT of the abdomen and pelvis, and/or CE-MRI of the abdomen±pelvis. If available, pathology or surgical findings served as the reference standard, otherwise, imaging followup was used. When SCI and PET/MRI results disagreed, medical records were checked for management changes. Follow-up data were collected until August 2021. RESULTS: One hundred sixty-four subjects were included, 85 (52%) were female, and the median age was 60 years (interquartile range 50-69). At a subject level, PET/MRI had higher sensitivity (0.97, 95% CI 0.86-1.00) than SCI (0.54, 95% CI 0.37-0.71), P < 0.001, without a difference in specificity, of 0.95 (95% CI 0.90-0.98) for PET/MRI and 0.98 (95% CI 0.93-1.00) for SCI, P » 0.250. PET/MRI and SCI results disagreed in 19 cases. In 5/19 (26%) of the discordant cases, PET/MRI findings consistent with PC missed on SCI led to management changes. CONCLUSION: PET/MRI improves detection of PC compared with SCI which frequently changes management.


Subject(s)
Peritoneal Neoplasms , Adult , Humans , Female , Middle Aged , Male , Peritoneal Neoplasms/diagnostic imaging , Standard of Care , Fluorodeoxyglucose F18 , Sensitivity and Specificity , Magnetic Resonance Imaging/methods , Positron-Emission Tomography/methods , Radiopharmaceuticals , Positron Emission Tomography Computed Tomography/methods
9.
J Immunol ; 210(1): 61-71, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36445376

ABSTRACT

γδ T cells reside at mucosal and epithelial barriers, and they often accumulate at sites of inflammation, both infectious and autoimmune, as well as in certain tumors. However, progress in understanding their function is considerably hampered by a lack of full understanding of the ligands recognized by TCR-γδ and how expression of these ligands is regulated. We recently developed a soluble human TCR-γδ (Vγ9Vδ1) tetramer from a synovial γδ T cell clone of a Lyme arthritis patient and observed that it stains monocytes activated by Borrelia burgdorferi. Those findings are extended in the current study to further examine the physiological regulation of ligand expression on monocytes. The TCR-γδ ligand is induced by a variety of TLR agonists and requires NF-κB activation. Of particular interest is that ligand expression also requires caspase activation of the inflammasome and is dependent on active metabolism, mitochondrial reactive oxygen species, and activation of gasdermin-D. Consistent with these observations, the TCR-γδ ligand is expressed by a subset of metabolically active CD14+CD16+ monocytes and colocalizes intracellularly with mitochondria. The findings suggest a model in which synovial γδ T cell ligand is a self-antigen whose surface expression is increased by inflammatory conditions and mitochondrial stress.


Subject(s)
Gasdermins , Receptors, Antigen, T-Cell, gamma-delta , Humans , Ligands , Reactive Oxygen Species/metabolism , Signal Transduction
10.
Eur Radiol ; 33(2): 1318-1328, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36074261

ABSTRACT

OBJECTIVES: To assess the impact of dual-energy CT (DECT) utilization in practice by measuring the readers' confidence, the need for additional image requests, and diagnostic performance in renal lesion assessment, compared to single-energy CT (SECT) using contrast-enhanced MRI to establish the reference standard. MATERIALS AND METHODS: Sixty-nine patients (M/F = 47/22) who underwent a dual-phase renal SECT (n = 34) or DECT (n = 35) and had a contrast-enhanced MRI within 180 days were retrospectively collected. Three radiologists assessed images on different sessions (SECT, DECT, and MRI) for (1) likely diagnosis (enhancing/non-enhancing); (2) diagnostic confidence (5-point Likert scale); (3) need for additional imaging test (yes/no); and (4) need for follow-up imaging (yes/no). Diagnostic accuracy was compared using AUC; p value < 0.05 was considered significant. RESULTS: One hundred fifty-six lesions consisting of 18% enhancing (n = 28/156, mean size: 30.37 mm, range: 9.9-94 mm) and 82% non-enhancing (n = 128/156, mean size: 23.91 mm, range: 5.0-94.2 mm) were included. The confidence level was significantly lower for SECT than their MRI (4.50 vs. 4.80, p value < 0.05) but not significantly different for DECT and the corresponding MRI (4.78 vs. 4.78, p > 0.05). There were significantly more requests for additional imaging in the SECT session than the corresponding MRI (20% vs. 4%), which was not significantly different between DECT and their MRI counterpart session (5.7% vs. 4.9%). Inter-reader agreement was almost perfect for DECT and MRI (kappa: 0.8-1) and substantial in SECT sessions (kappa: 0.6-0.8) with comparable diagnostic accuracy between SECT, DECT, and MRI (p value > 0.05). CONCLUSION: Single-phase DECT allows confident and reproducible characterization of renal masses with fewer recommendation for additional and follow-up imaging tests than dual-phase SECT and a performance similar to MRI. KEY POINTS: • DECT utilization leads to similar additional image requests to MRI (5.7% vs. 4.9%, p value > 0.05), whereas single-energy CT utilization leads to significantly higher image requests (20% vs. 4%, p value < 0.05). • DECT and MRI utilization bring highly reproducible results with almost perfect inter-reader agreement (kappa: 0.8-1), better than the inter-reader agreement in SECT utilization (kappa: 0.6-0.8). • Readers' confidence was not significantly altered between DECT and their MRI readout session (p value > 0.05). In contrast, confidence in the diagnosis was significantly lower in the SECT session than their MRI readout (p value < 0.05).


Subject(s)
Radiography, Dual-Energy Scanned Projection , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Contrast Media , Radiography, Dual-Energy Scanned Projection/methods , Retrospective Studies , Radiation Dosage , Magnetic Resonance Imaging
11.
J Int Med Res ; 50(11): 3000605221135446, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36324277

ABSTRACT

OBJECTIVE: To determine the incidence and significance of ventilator avoidance in patients with critical coronavirus disease 2019 (COVID-19). METHODS: This prospective observational cohort study evaluated hospital mortality and 1-year functional outcome among critically ill patients with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-associated acute respiratory distress syndrome (ARDS). The explanatory variable was ventilator avoidance, modeled as 'initial refusal' of intubation (yes/no). Modified Rankin Scale (mRS) scores were obtained from surviving patients (or their surrogates) via phone or email questionnaire. RESULTS: Among patients for whom intubation was recommended (n = 102), 40 (39%) initially refused (95% confidence interval [CI] 30%, 49%). The risk of death was 79.3% (49/62) in those who did not initially refuse intubation compared with 77.5% (31/40) in those who initially refused, with an adjusted odds ratio for death of 1.27 (95% CI 0.47, 3.48). The distribution of 1-year mRS scores was not significantly different between groups. CONCLUSION: Among critically ill patients with COVID-19-associated ARDS, ventilator avoidance was common, but was not associated with increased in-hospital mortality or 1-year functional outcome.


Subject(s)
COVID-19 , Respiratory Distress Syndrome , Humans , SARS-CoV-2 , Critical Illness , Prospective Studies , Respiratory Distress Syndrome/therapy , Ventilators, Mechanical
13.
Schizophr Bull ; 48(3): 551-562, 2022 05 07.
Article in English | MEDLINE | ID: mdl-35137221

ABSTRACT

INTRODUCTION: Illuminating neurobiological mechanisms underlying the protective effect of recently discovered common genetic resilience variants for schizophrenia is crucial for more effective prevention efforts. Current models implicate adaptive neuroplastic changes in the visual system and their pro-cognitive effects as a schizophrenia resilience mechanism. We investigated whether common genetic resilience variants might affect brain structure in similar neural circuits. METHOD: Using structural magnetic resonance imaging, we measured the impact of an established schizophrenia polygenic resilience score (PRSResilience) on cortical volume, thickness, and surface area in 101 healthy subjects and in a replication sample of 33 224 healthy subjects (UK Biobank). FINDING: We observed a significant positive whole-brain correlation between PRSResilience and cortical volume in the right fusiform gyrus (FFG) (r = 0.35; P = .0004). Post-hoc analyses in this cluster revealed an impact of PRSResilience on cortical surface area. The replication sample showed a positive correlation between PRSResilience and global cortical volume and surface area in the left FFG. CONCLUSION: Our findings represent the first evidence of a neurobiological correlate of a genetic resilience factor for schizophrenia. They support the view that schizophrenia resilience emerges from strengthening neural circuits in the ventral visual pathway and an increased capacity for the disambiguation of social and nonsocial visual information. This may aid psychosocial functioning, ameliorate the detrimental effects of subtle perceptual and cognitive disturbances in at-risk individuals, and facilitate coping with the cognitive and psychosocial consequences of stressors. Our results thus provide a novel link between visual cognition, the vulnerability-stress concept, and schizophrenia resilience models.


Subject(s)
Schizophrenia , Brain/metabolism , Humans , Magnetic Resonance Imaging , Multifactorial Inheritance , Schizophrenia/diagnostic imaging , Schizophrenia/genetics , Schizophrenia/metabolism , Visual Pathways/diagnostic imaging , Visual Pathways/pathology
15.
Infect Control Hosp Epidemiol ; 43(4): 490-496, 2022 04.
Article in English | MEDLINE | ID: mdl-33853694

ABSTRACT

OBJECTIVE: We hypothesized that healthcare workers (HCWs) with high-risk exposures outside the healthcare system would have less asymptomatic coronavirus 2019 (COVID-19) disease and more symptoms than those without such exposures. DESIGN: A longitudinal point prevalence study was conducted during August 17-September 4, 2020 (period 1) and during December 2-23, 2020 (period 2). SETTING: Community based teaching health system. PARTICIPANTS: All HCWs were invited to participate. Among HCWs who acquired COVID-19, logistic regression models were used to evaluate the adjusted odds of asymptomatic disease using high-risk exposure outside the healthcare system as the explanatory variable. The number of symptoms between exposure groups was evaluated with the Wilcoxon rank-sum test. The risk of seropositivity among all HCS by work exposure was evaluated during both periods. INTERVENTIONS: Survey and serological testing. RESULT: Seroprevalence increased from 1.9% (95% confidence interval [CI], 1.2%-2.6%) to 13.7% (95% CI, 11.9%-15.5%) during the study. Only during period 2 did HCWs with the highest work exposure (versus low exposure) have an increased risk of seropositivity (risk difference [RD], 7%; 95% CI, 1%-13%). Participants who had a high-risk exposure outside of work (compared to those without) had a decreased probability of asymptomatic disease (odds ratio [OR], 0.38; 95% CI, 0.16-0.86) and demonstrated more symptoms (median 3 [IQR, 2-6] vs 1 [IQR, 0-4]; P = .001). CONCLUSIONS: Healthcare-acquired COVID-19 increases the probability of asymptomatic or mild COVID-19 disease compared to community-acquired disease. This finding suggests that infection prevention strategies (including masks and eye protection) may be mitigating inoculum and supports the variolation theory in COVID-19.


Subject(s)
COVID-19 , Asymptomatic Diseases , COVID-19/epidemiology , Delivery of Health Care , Health Personnel , Humans , SARS-CoV-2 , Seroepidemiologic Studies
16.
Invest Radiol ; 57(1): 52-61, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34162795

ABSTRACT

MATERIALS AND METHODS: Forty-four patients with clinical contrast-enhanced abdominal examinations on each of the 3 DECT scanner types and a phantom scanned with the same protocols were included in this retrospective study. Qualitative and quantitative assessment was performed on VUE images. Quantitative evaluation included measurement of attenuation and image noise for various tissues and the phantom. Virtual unenhanced image attenuation and noise were compared between scanner types, and intrapatient interscanner reproducibility of virtual unenhanced image attenuation was calculated as the percentage of measurement pairs with an interscanner difference ≤ 10 HU. Image quality, noise, sharpness, and iodine elimination were assessed qualitatively by 2 radiologists. RESULTS: Significant interscanner differences in VUE attenuation and noise were found in all tissues. dlDECT and rsDECT showed significantly higher VUE attenuation than dsDECT in the aorta, portal vein, and kidneys (P < 0.05). Conversely, VUE attenuation in dsDECT was significantly higher than in dlDECT/rsDECT for subcutaneous and retroperitoneal fat (both P < 0.05). A total of 91.9% (385/419) of measurements were reproducible between rsDECT and dlDECT, 70.9% (297/419) between dsDECT and rsDECT, and 66.8% (280/419) between dsDECT and dlDECT. Virtual unenhanced image attenuation in the contrast media-filled phantom cavity was 12.7 ± 4.7 HU in dlDECT, -5.3 ± 4.2 HU in rsDECT, and -4.0 ± 10.7 HU in dsDECT with significant differences between dlDECT and rsDECT/dsDECT, respectively (P < 0.05), between which attenuation was comparable in the unenhanced extraluminal phantom component (P = 0.11-0.62). Qualitatively, dsDECT yielded best iodine elimination, whereas sharpness, image noise, and overall image quality were rated higher in dlDECT and rsDECT. CONCLUSIONS: There are significant interscanner differences in the attenuation measurements and qualitative assessment of VUE images, which should be acknowledged when using these images in patients that are being scanned on different DECT scanner types during imaging follow-up.


Subject(s)
Radiography, Dual-Energy Scanned Projection , Contrast Media , Humans , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
17.
J Child Orthop ; 15(3): 298-303, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-34211607

ABSTRACT

PURPOSE: The purpose of this study was to define the incidence of trochlear dysplasia in an infant cohort being screened for developmental dysplasia of the hip (DDH). METHODS: Newborns screened for DDH that were evaluated with ultrasound for the presence of trochlear dysplasia were retrospectively reviewed. The sulcus angle and trochlear depth were measured. Based on previous work, trochlear dysplasia was defined as a sulcus angle of > 159°. Our newborn cohort was then analyzed to identify potential risk factors for trochlear dysplasia. RESULTS: A total of 383 knees in 196 infants were studied. In total, 52% were referred for breech intrauterine positioning and 21% were ultimately diagnosed with DDH and had treatment initiated with a Pavlik harness. Of the entire cohort, 8% of knees were deemed to have trochlear dysplasia. Breech patients were found to have a flatter sulcus angle than those that were not breech (149.5° (sd 7.2°) versus 147.9° (sd 7.5°); p = 0.028). Similarly, a shallower trochlear depth was identified in breech patients versus non-breech patients (1.6 mm (sd 0.4) versus 1.8 mm (sd 0.4); p = 0.019). Those with trochlear dysplasia (as defined by sulcus angle > 159°) did show a smaller alpha angle (i.e. more dysplastic hip) as compared with those without trochlear dysplasia (59.2° (sd 10.2°) versus 65.9° (sd 7.5°); p < 0.001). Hips with DDH were 2.4-times more likely to have knees with trochlear dysplasia (95% confidence interval 1.1 to 5.3). CONCLUSION: Ultrasound screening of newborn knees reveals that trochlear dysplasia is relatively common in breech babies with DDH. LEVEL OF EVIDENCE: III.

18.
Insights Imaging ; 12(1): 95, 2021 Jul 07.
Article in English | MEDLINE | ID: mdl-34232414

ABSTRACT

Tumors of the genital system are common and imaging is of crucial importance for their detection and diagnosis. Several non-neoplastic diseases may mimic these tumors and differential diagnosis may be difficult in certain cases. Misdiagnosing non-neoplastic diseases as tumor may prompt unnecessary medical treatment or surgical interventions. In this article, we aimed to present the imaging characteristics of non-neoplastic diseases of the male and female genital systems that may mimic neoplastic processes. Increasing awareness of the imaging specialists to these entities may have a severe positive impact on the management of these patients.

20.
Abdom Radiol (NY) ; 46(10): 4828-4852, 2021 10.
Article in English | MEDLINE | ID: mdl-34047800

ABSTRACT

The spleen plays an important role in the immunological homeostasis of the body. Several neoplastic and non-neoplastic diseases may affect this organ, and imaging is of fundamental importance for diagnosis. Infectious diseases of the spleen can be encountered in daily radiology practice, and differential diagnosis may sometimes be challenging. Infectious involvement of the spleen can be primary or secondary to a different source outside the spleen. Despite the fact that different infectious diseases may cause similar imaging findings, we believe that differential diagnosis between different causes may also be possible in certain patients with imaging. Early diagnosis may potentially enhance patients' treatment and outcome. In this review, we aimed to increase imaging specialists' awareness of splenic infections by describing the multimodality imaging features of common and atypical infections of the spleen with their differential diagnoses.


Subject(s)
Splenic Diseases , Diagnosis, Differential , Humans , Multimodal Imaging , Radiography , Splenic Diseases/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...