Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Coron Artery Dis ; 24(1): 61-8, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23232250

ABSTRACT

OBJECTIVE: To report the final, cumulative, 5-year outcomes from the TAXUS ATLAS program, which studied the use of the TAXUS Liberté paclitaxel-eluting stent in de-novo coronary artery lesions. METHODS: TAXUS ATLAS Workhorse, Small Vessel, and Long Lesion are nonrandomized studies comparing TAXUS Liberté (N=871), TAXUS Liberté 2.25 mm (N=261), and TAXUS Liberté 38 mm (N=150) stents, respectively, with case-matched TAXUS Express historical controls. RESULTS: In the unadjusted analysis, TAXUS Liberté showed comparable 5-year rates of major adverse cardiac events (27.1% TAXUS Express vs. 26.2% TAXUS Liberté, P=0.70) in workhorse lesions and greater 5-year cumulative freedom from target lesion revascularization (78.4 vs. 87.3%, P=0.03) in small vessels. In addition, a lower periprocedural myocardial infarction rate (MI, 4.1 vs. 0.0%; P=0.01) was observed in long lesions versus TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on the 5-year rates of TLR in small vessels (17.9 vs. 13.3%, P=0.36) or MI in long lesions (9.1 vs. 7.0%, P=0.53) was found, although the rates remained numerically lower with TAXUS Liberté. CONCLUSION: Cumulative 5-year results of the TAXUS ATLAS studies suggest that the TAXUS Liberté stent provides similar safety and effectiveness in workhorse lesions, and may provide lower revascularization rates in small vessels and lower periprocedural MI rates in long lesions compared with the TAXUS Express stent, although no statistically significant differences were found following propensity adjustment.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Paclitaxel/administration & dosage , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Asia , Chi-Square Distribution , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Humans , Kaplan-Meier Estimate , Logistic Models , Myocardial Infarction/etiology , New Zealand , Propensity Score , Prospective Studies , Prosthesis Design , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , United States
2.
Circ J ; 75(5): 1120-9, 2011.
Article in English | MEDLINE | ID: mdl-21467655

ABSTRACT

BACKGROUND: The long-term impact of treating de novo coronary lesions in native vessels and challenging small vessel and long lesion subsets with TAXUS Liberté stents is unknown. This report examines the 3-year efficacy and safety from the TAXUS ATLAS program. METHODS AND RESULTS: TAXUS ATLAS WH, Small Vessel, and Long Lesion are non-randomized studies comparing TAXUS Liberté (n = 871), TAXUS Liberté 2.25 mm (n = 261), and TAXUS Liberté 38 mm (n = 150) stents, respectively, to case-matched TAXUS Express historical controls. TAXUS Liberté demonstrated comparable 3-year rates of major adverse cardiac events (19.0% vs. 20.2%, P = 0.51) in de novo lesions, reduced target lesion revascularization (TLR, 10.0% vs. 22.1%, P = 0.008) in small vessels, and reduced myocardial infarction (MI, 2.9% vs. 10.4%; P = 0.01) and stent thrombosis (ST, 0.0% vs. 3.9%, P = 0.03) in long lesions vs. TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on TLR (9.7% vs. 16.9%, P = 0.12) in small vessels or MI (2.9% vs. 7.9%, P = 0.05) in long lesions was noted, although reduced ST (0.0% vs. 2.7%, P = 0.02) remained in long lesions. Multivariate analyses demonstrated that TAXUS Liberté treatment significantly reduced TLR by 66% in small vessels, and MI by 75% in long lesions, vs. TAXUS Express. CONCLUSIONS: TAXUS Liberté suggests durable 3-year effectiveness in reducing restenosis and improved clinical outcomes in small vessels and long lesions compared with TAXUS Express.


Subject(s)
Stents , Humans , Taxus
3.
Cardiovasc Revasc Med ; 12(4): 247-57, 2011.
Article in English | MEDLINE | ID: mdl-21130708

ABSTRACT

BACKGROUND: The objective of this intravascular ultrasound (IVUS) analysis was to evaluate the vascular response of the thin-strut TAXUS Liberté stent compared with the otherwise identical TAXUS Express stent. METHODS AND MATERIALS: The TAXUS ATLAS and TAXUS ATLAS Long Lesion studies are nonrandomized trials comparing the thin-strut TAXUS Liberté stent to historical TAXUS Express controls from the TAXUS IV and TAXUS V trials. A total of 377 patients enrolled in the two TAXUS ATLAS studies were randomly selected for the IVUS subset and compared to 314 TAXUS Express IVUS controls. RESULTS: Despite increased lesion complexity in the TAXUS Liberté group, neointimal formation at 9 months was similar in both stents (TAXUS Liberté 13.8±11.0%; TAXUS Express 13.1±13.8%, P=.56). However, this neointima covered more of the overall stent in the TAXUS Liberté (67.9±32.5%) compared with the TAXUS Express (54.4±37.2%, P<.001), suggesting more uniform neointimal distribution. TAXUS Liberté also showed less pronounced negative remodeling at both stent edges and had significantly less (4.3% vs. 9.6%, P=.04) late incomplete stent apposition (ISA). CONCLUSIONS: Despite identical polymer and drug release characteristic, the thin-strut TAXUS Liberté stent demonstrates improved neointimal coverage, better edge remodeling, and less late ISA vs. TAXUS Express, hereby highlighting the importance of the platform design for drug-eluting stents.


Subject(s)
Coronary Restenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Prosthesis Design/methods , Cardiovascular Agents/administration & dosage , Coronary Restenosis/prevention & control , Coronary Stenosis/surgery , Coronary Vessels/drug effects , Coronary Vessels/surgery , Double-Blind Method , Female , Follow-Up Studies , Humans , Male , Middle Aged , Paclitaxel/administration & dosage , Prospective Studies , Stents , Treatment Outcome , Tunica Intima/diagnostic imaging , Tunica Intima/drug effects , Ultrasonography, Interventional/methods
4.
JACC Cardiovasc Interv ; 2(3): 240-52, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19463432

ABSTRACT

OBJECTIVES: The aim of this study was to assess the relative efficacy and safety of the second-generation TAXUS Liberté paclitaxel-eluting stent (PES) in patients with and without diabetes mellitus. BACKGROUND: Diabetic patients suffer from accelerated atherosclerosis and increased risk of restenosis after coronary interventions; however, prior data suggest that PES might blunt this effect, providing equal benefit in diabetic and nondiabetic patients. METHODS: A pooled analysis of all 4 TAXUS ATLAS studies was conducted that included 413 diabetic and 1,116 nondiabetic subjects treated with the TAXUS Liberté stent for de novo coronary lesions. Angiographic and intravascular ultrasound outcomes at 9 months and clinical outcomes at 9 and 12 months were compared in patients with and without diabetes. Propensity score and multivariate adjustments were performed to correct for baseline differences. RESULTS: In-stent angiographic restenosis (13.0% vs. 9.6%, p = 0.12), late luminal loss (0.40 mm vs. 0.38 mm, p = 0.58), and intimal hyperplasia (14.8% vs. 13.4%, p = 0.29) were similar for diabetic and nondiabetic subjects. After propensity adjustment, 12-month target lesion revascularization rates were similar for diabetic and nondiabetic subjects (6.4% vs. 4.7%, p = 0.18), with no differences in mortality, myocardial infarction, or stent thrombosis. However, the rate of target vessel revascularization (TVR) was higher for diabetic subjects due to increased TVR outside the target lesion (TVR Remote). CONCLUSIONS: Similar clinical, angiographic, and intravascular ultrasound outcomes were observed for both diabetic and nondiabetic subjects treated with TAXUS Liberté, suggesting that this PES attenuates the effect of diabetes on restenosis after percutaneous coronary intervention, yielding comparable efficacy and safety in diabetic and nondiabetic patients. (TAXUS ATLAS; NCT00371709, NCT00371423, NCT00371748, and NCT00371475).


Subject(s)
Coronary Restenosis/therapy , Diabetes Mellitus/drug therapy , Drug-Eluting Stents , Paclitaxel/therapeutic use , Antineoplastic Agents, Phytogenic/adverse effects , Antineoplastic Agents, Phytogenic/therapeutic use , Case-Control Studies , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/prevention & control , Diabetes Mellitus/therapy , Female , Humans , Male , Middle Aged , Multivariate Analysis , Paclitaxel/adverse effects , Risk Assessment , Risk Factors , Ultrasonography, Interventional
5.
JACC Cardiovasc Interv ; 1(2): 150-60, 2008 Apr.
Article in English | MEDLINE | ID: mdl-19463293

ABSTRACT

OBJECTIVES: This study was conducted to determine whether direct stenting with TAXUS Liberté is noninferior to stenting after pre-dilation. BACKGROUND: Direct stenting is performed in approximately 30% of patients, but data on clinical and angiographic outcomes with drug-eluting stents are limited. METHODS: The TAXUS ATLAS DIRECT STENT is a single-arm, multicenter study that enrolled patients with de novo coronary lesions visually estimated to be 10 to 28 mm in length in vessels 2.5 to 4.0 mm in diameter. The control group is the quantitative coronary angiography (QCA) subset of the TAXUS ATLAS trial, which used identical inclusion and exclusion criteria but mandated pre-dilation. The primary end point is 9-month analysis-segment percent diameter stenosis (%DS). RESULTS: Baseline patient characteristics were similar between the groups. On QCA analysis, significantly shorter lesions with larger lumen diameter and less calcification were observed in the direct stent group. Direct stenting was successful in 97.6% of patients and was associated with a shorter procedure time and fewer complications. Follow-up %DS was noninferior for direct stent (26.41%) versus pre-dilation (29.14%) with a 1-sided 95% confidence interval of the difference between the groups (-0.34%) well below the pre-specified noninferiority margin (6.75%). Additionally, significantly lower restenosis (5.9% vs. 11.4%, p = 0.0229) and target lesion revascularization (TLR) 2.9% vs. 7.8%, p = 0.0087) rates were seen for direct stent versus pre-dilation. CONCLUSIONS: Direct stenting of TAXUS Liberté is feasible and highly successful in carefully selected lesions. Direct stenting is noninferior to stenting after pre-dilation on the basis of %DS and can significantly reduce procedural time, procedural complications, and possibly angiographic restenosis and TLR.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Stenosis/therapy , Drug-Eluting Stents , Paclitaxel/administration & dosage , Aged , Angioplasty, Balloon, Coronary/adverse effects , Coronary Angiography , Coronary Restenosis/etiology , Coronary Restenosis/prevention & control , Coronary Stenosis/diagnostic imaging , Feasibility Studies , Female , Humans , Male , Middle Aged , New Zealand , Prospective Studies , Prosthesis Design , Severity of Illness Index , Singapore , Thrombosis/etiology , Thrombosis/prevention & control , Time Factors , Treatment Outcome , United States
6.
JACC Cardiovasc Interv ; 1(6): 699-709, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19463387

ABSTRACT

OBJECTIVES: The TAXUS ATLAS Small Vessel (SV) and Long Lesion (LL) multicenter studies compared the performance of the thin-strut (0.0038 inch) TAXUS Liberté 2.25-mm stent (Boston Scientific; Natick, Massachusetts) and the TAXUS Liberté 38-mm long stent (Boston Scientific; Natick, Massachusetts) with the earlier paclitaxel-eluting TAXUS Express (Boston Scientific) stent that has identical polymer, drug dosage, and release kinetics but different stent geometry and thicker struts (0.0052 inch). BACKGROUND: The TAXUS Liberté stent was designed with thinner and more even strut spacing to provide more uniform drug distribution, as well as increased flexibility and conformability. Clinical benefits of the new stent design have not been evaluated. METHODS: The TAXUS ATLAS SV and LL studies are nonrandomized studies comparing outcomes of the TAXUS Liberté 2.25 mm (N = 261) and TAXUS Liberté 38 mm (N = 150) stents to TAXUS Express historical control groups derived from the TAXUS IV and V trials. Inclusion/exclusion criteria for TAXUS Express and Liberté groups were similar in both studies. RESULTS: Each study met its primary end point of noninferiority of 9-month in-segment diameter stenosis. Furthermore, TAXUS Liberté 2.25 mm, when compared with TAXUS Express, significantly reduced the rate of both 9-month angiographic restenosis (18.5% vs. 32.7%, p = 0.0219) and 12-month target lesion revascularization (6.1% vs. 16.9%, p = 0.0039). In addition, TAXUS Liberté 38 mm significantly reduced the risk of 12-month myocardial infarction compared with TAXUS Express (1.4% vs. 6.5%, p = 0.0246). CONCLUSIONS: The thinner-strut TAXUS Liberté stent improved outcomes compared with the earlier TAXUS Express stent in both SVs and LLs (A Study of the TAXUS Liberté Stent for the Treatment of de Novo Coronary Artery Lesions in Small Vessels; NCT00371748; A Study of the TAXUS Liberté Stent for the Treatment of Long De Novo Coronary Artery Lesions; NCT00371475).


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Restenosis/prevention & control , Drug-Eluting Stents , Myocardial Infarction/prevention & control , Paclitaxel/administration & dosage , Aged , Angioplasty, Balloon, Coronary/mortality , Asia , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/mortality , Female , Humans , Linear Models , Logistic Models , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/etiology , Myocardial Infarction/mortality , North America , Platelet Aggregation Inhibitors/therapeutic use , Proportional Hazards Models , Prosthesis Design , Risk Assessment , Time Factors , Treatment Outcome
7.
J Am Coll Cardiol ; 49(16): 1676-83, 2007 Apr 24.
Article in English | MEDLINE | ID: mdl-17448368

ABSTRACT

OBJECTIVES: The goal of this research was to assess non-inferiority of the next-generation TAXUS Liberté stent (Boston Scientific Corp., Natick, Massachusetts) versus the TAXUS Express stent (Boston Scientific Corp.). BACKGROUND: The introduction of drug-eluting stents (DES) has shifted clinical practice towards more complex lesion subsets, prompting the need for more deliverable DES. TAXUS Liberté was designed to combine the established polymer-based, paclitaxel-elution TAXUS technology with the more advanced Liberté stent platform. METHODS: The TAXUS ATLAS study is a global, prospective, single-arm trial evaluating outcomes in de novo coronary lesions visually estimated to be 10 to 28 mm in length in vessels 2.5 to 4.0 mm in diameter. The control group is an entry-criteria-matched population of TAXUS Express patients from the TAXUS IV and V trials. The primary end point is non-inferiority of TAXUS Liberté versus TAXUS Express for 9-month target vessel revascularization. RESULTS: Despite similar inclusion criteria, quantitative coronary angiography-determined baseline lesion characteristics were significantly more complex for TAXUS Liberté than TAXUS Express. The primary non-inferiority end point was met with the 1-sided 95% confidence bound of 2.98% less than the pre-specified non-inferiority margin of 3% (p = 0.0487). CONCLUSIONS: Despite the treatment of more complex lesions with TAXUS Liberté, the primary end point was met, demonstrating that TAXUS Liberté is non-inferior to TAXUS Express. The successful transfer of the proven TAXUS technology to the more advanced TAXUS Liberté platform was demonstrated. (TAXUS ATLAS: TAXUS Liberté-SR Stent for the Treatment of De Novo Coronary Artery Lesions; http://www.clinicaltrials.gov/ct/show/NCT00371709?order=1; NCT00371709).


Subject(s)
Coronary Stenosis/drug therapy , Neovascularization, Physiologic/drug effects , Paclitaxel/administration & dosage , Stents , Tubulin Modulators/administration & dosage , Aged , Endpoint Determination , Equipment Design , Female , Humans , Male , Middle Aged , Polymers , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...