Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 323
Filter
1.
World J Urol ; 42(1): 415, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39012490

ABSTRACT

PURPOSE: To experimentally measure renal pelvis pressure (PRP) in an ureteroscopic model when applying a simple hydrodynamic principle, the siphoning effect. METHODS: A 9.5Fr disposable ureteroscope was inserted into a silicone kidney-ureter model with its tip positioned at the renal pelvis. Irrigation was delivered through the ureteroscope at 100 cm above the renal pelvis. A Y-shaped adapter was fitted onto the model's renal pelvis port, accommodating a pressure sensor and a 4 Fr ureteral access catheter (UAC) through each limb. The drainage flowrate through the UAC tip was measured for 60 s each run. The distal tip of the UAC was placed at various heights below or above the center of the renal pelvis to create a siphoning effect. All trials were performed in triplicate for two lengths of 4Fr UACs: 100 cm and 70 cm (modified from 100 cm). RESULTS: PRP was linearly dependent on the height difference from the center of the renal pelvis to the UAC tip for both tested UAC lengths. In our experimental setting, PRP can be reduced by 10 cmH20 simply by lowering the distal tip of a 4 Fr 70 cm UAC positioned alongside the ureteroscope by 19.7 cm. When using a 4 Fr 100 cm UAC, PRP can drop 10 cmH20 by lowering the distal tip of the UAC 23.3 cm below the level of the renal pelvis. CONCLUSION: Implementing the siphoning effect for managing PRP during ureteroscopy could potentially enhance safety and effectiveness.


Subject(s)
Kidney Pelvis , Pressure , Ureter , Ureteroscopy , Ureteroscopy/methods , Ureter/physiology , Humans , Models, Anatomic , Ureteroscopes , In Vitro Techniques
2.
Article in English | MEDLINE | ID: mdl-38837932

ABSTRACT

Histotripsy is a non-invasive ablation technique that focuses ultrasound pulses into the body to destroy tissues via cavitation. Heterogeneous acoustic paths through tissue introduce phase errors that distort and weaken the focus, requiring additional power output from the histotripsy transducer to perform therapy. This effect, termed phase aberration, limits the safety and efficacy of histotripsy ablation. It has been shown in vitro that the phase errors from aberration can be corrected by receiving the acoustic signals emitted by cavitation. For transabdominal histotripsy in vivo, however, cavitation-based aberration correction is complicated by acoustic signal clutter and respiratory motion. This study develops a method that enables robust, effective cavitation-based aberration correction in vivo and evaluates its efficacy in the swine liver. The method begins with a high-speed pulsing procedure to minimize the effects of respiratory motion. Then, an optimal phase correction is obtained in the presence of acoustic clutter by filtering with the singular value decomposition. This aberration correction method reduced the power required to generate cavitation in the liver by 26% on average (range: 0% to 52%) and required ~2 s for signal acquisition and processing per focus location. These results suggest that the cavitation-based method could enable fast and effective aberration correction for transabdominal histotripsy.

3.
Ultrasound Med Biol ; 50(8): 1155-1166, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38789304

ABSTRACT

OBJECTIVE: The goal of the work described here was to develop the first neuronavigation-guided transcranial histotripsy (NaviTH) system and associated workflow for transcranial ablation. METHODS: The NaviTH system consists of a 360-element, 700 kHz transmitter-receiver-capable transcranial histotripsy array, a clinical neuronavigation system and associated equipment for patient-to-array co-registration and therapy planning and targeting software systems. A workflow for NaviTH treatments, including pre-treatment aberration correction, was developed. Targeting errors stemming from target registration errors (TREs) during the patient-to-array co-registration process, as well as focal shifts caused by skull-induced aberrations, were investigated and characterized. The NaviTH system was used in treatments of two <96 h post-mortem human cadavers and in experiments in two excised human skullcaps. RESULTS: The NaviTH was successfully used to create ablations in the cadaver brains as confirmed in post-treatment magnetic resonance imaging A total of three ablations were created in the cadaver brains, and targeting errors of 9, 3.4 and 4.4 mm were observed in corpus callosum, septum and thalamus targets, respectively. Errors were found to be caused primarily by TREs resulting from transducer tracking instrument design flaws and imperfections in the treatment workflow. Transducer tracking instrument design and workflow improvements reduced TREs to <2 mm, and skull-induced focal shifts, following pre-treatment aberration correction, were 0.3 mm. Total targeting errors of the NaviTH system following the noted improvements were 2.5 mm. CONCLUSIONS: The feasibility of using the first NaviTH system in a human cadaver model has been determined. Although accuracy still needs to be improved, the proposed system has the potential to allow for transcranial histotripsy therapies without requiring active magnetic resonance treatment guidance.


Subject(s)
Cadaver , Neuronavigation , Humans , Neuronavigation/methods , Brain/diagnostic imaging , Brain/surgery , Equipment Design , High-Intensity Focused Ultrasound Ablation/methods
4.
Ultrasound Med Biol ; 50(8): 1214-1223, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38797630

ABSTRACT

OBJECTIVE: Nanoparticle-mediated histotripsy (NMH) is a novel ablation method that combines nanoparticles as artificial cavitation nuclei with focused ultrasound pulsing to achieve targeted, non-invasive, and cell-selective tumor ablation. The study described here examined the effect of dual-frequency histotripsy pulsing on the cavitation threshold, bubble cloud characteristics, and ablative efficiency in NMH. High-speed optical imaging was used to analyze bubble cloud characteristics and to measure ablation efficiency for NMH inside agarose tissue phantoms containing perfluorohexane-filled nanocone clusters, which were previously developed to reduce the histotripsy cavitation threshold for NMH. METHODS: Dual-frequency histotripsy pulsing was applied at a 1:1 pressure ratio using a modular 500 kHz and 3 MHz dual-frequency array transducer. Optical imaging results revealed predictable, well-defined bubble clouds generated for all tested cases with similar reductions in the cavitation thresholds observed for single-frequency and dual-frequency pulsing. RESULTS: Dual-frequency pulsing was seen to nucleate small, dense clouds in agarose phantoms, intermediate in size of their component frequencies but closer in area to that of the higher component frequency. Red blood cell experiments revealed complete ablations were generated by dual-frequency NMH in all phantoms in <1500 pulses. This result was a significant increase in ablation efficiency compared with the ∼4000 pulses required in prior single-frequency NMH studies. CONCLUSION: Overall, this study indicates the potential for using dual-frequency histotripsy methods to increase the ablation efficacy of NMH.


Subject(s)
High-Intensity Focused Ultrasound Ablation , Nanoparticles , Phantoms, Imaging , High-Intensity Focused Ultrasound Ablation/methods
5.
Article in English | MEDLINE | ID: mdl-38758626

ABSTRACT

Since the late 1970s, the speckle interference patterns ubiquitous in pulse-echo ultrasound images have been used to characterize subresolution tissue structures. During this time, new models, estimation methods, and processing techniques have proliferated, offering a wealth of recommendations for the task of tissue characterization. A literature review was performed to draw attention to these various methods and to critically track assumptions and gaps in knowledge. A total of 388 articles were collected from a systematic search for first-order speckle statistics in diagnostic ultrasound in the NIH PubMed database and Elsevier's Scopus database. Articles were grouped by basic characteristics and evaluated for addressing fundamental assumptions. A sampling of models and methods is presented to reveal the state of the art in speckle statistics as well as sources of measurement error and other important considerations. While this body of literature emphasizes the value of speckle analysis in diagnostic ultrasound, it is shown that relatively little attention is devoted to basic assumptions such as the linearity of system response and scatterer geometry. Additionally, several areas of investigation are available to improve upon speckle statistics analysis, potentially leading to the advancement of this unique tool.


Subject(s)
Image Processing, Computer-Assisted , Ultrasonography , Humans , Algorithms , Image Processing, Computer-Assisted/methods , Ultrasonography/methods
6.
AJR Am J Roentgenol ; 222(6): e2330775, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38506537

ABSTRACT

BACKGROUND. Metabolic dysfunction-associated steatotic liver disease is a growing global public health concern. Quantitative ultrasound measurements, such as ultrasound-derived fat fraction (UDFF), could provide noninvasive, cost-effective, and portable steatosis evaluation. OBJECTIVE. The purpose of this article was to evaluate utility of UDFF for steatosis assessment using proton density fat fraction (PDFF) as reference in patients undergoing liver MRI for heterogeneous indications and to assess UDFF variability. METHODS. This prospective study included a primary analysis of 187 patients (mean age, 53.8 years; 112 men, 75 women) who underwent 3-T liver MRI for any clinical indication from December 2020 to July 2021. Patients underwent investigational PDFF measurement, including determination of PDFFwhole-liver (mean PDFF of entire liver), and PDFFvoxel (PDFF in single voxel within right lobe, measured by MR spectroscopy), as well as investigational ultrasound with UDFF calculation (mean of five inter-costal measurements) within 1 hour after MRI. In a subanalysis, 21 of these patients underwent additional UDFF measurements 1, 3, and 5 hours after meal consumption. The study also included repeatability and reproducibility analysis of 30 patients (mean age, 26.3 years; 10 men, 20 women) who underwent clinical abdominal ultrasound between November 2022 and January 2023; in these patients, three operators sequentially performed UDFF measurements. RESULTS. In primary analysis, UDFF and PDFFwhole-liver measurements showed intra-class correlation coefficient (ICC) of 0.79. In Bland-Altman analysis, UDFF and PDFFvoxel measurements showed mean difference of 1.5% (95% CI, 0.6-2.4%), with 95% limits of agreement from -11.0% to 14.0%. UDFF measurements exhibited AUC for detecting PDFFvoxel at historic thresholds of 6.5% and greater, 17.4% and greater, and 22.1% and greater of 0.90, 0.95, and 0.95, respectively. In subanalysis, mean UDFF was not significantly different across time points with respect to meal consumption (p = .21). In repeatability and reproducibility analysis, ICC for intraoperator repeatability ranged from 0.98 to 0.99 and for interoperator reproducibility from 0.90 to 0.96. Visual assessment of patient-level data plots indicated increasing variability of mean UDFF measurements across operators and of intercostal measurements within individual patients with increasing steatosis. CONCLUSION. UDFF showed robust agreement with PDFF, diagnostic performance for steatosis grades, and intraoperator repeatability and interoperator reproducibility. Nonetheless, UDFF exhibited bias toward slightly larger values versus PDFF; intraoperator and interoperator variation increased with increasing steatosis. CLINICAL IMPACT. UDFF shows promise for steatosis assessment across diverse populations, although continued optimization remains warranted.


Subject(s)
Magnetic Resonance Imaging , Ultrasonography , Humans , Male , Female , Prospective Studies , Middle Aged , Magnetic Resonance Imaging/methods , Ultrasonography/methods , Fatty Liver/diagnostic imaging , Adult , Reproducibility of Results , Liver/diagnostic imaging , Aged , Adipose Tissue/diagnostic imaging
7.
World J Urol ; 42(1): 197, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38530484

ABSTRACT

INTRODUCTION: High fluid temperatures have been seen in both in vitro and in vivo studies with laser lithotripsy, yet the thermal distribution within the renal parenchyma has not been well characterized. Additionally, the heat-sink effect of vascular perfusion remains uncertain. Our objectives were twofold: first, to measure renal tissue temperatures in response to laser activation in a calyx, and second, to assess the effect of vascular perfusion on renal tissue temperatures. METHODS: Ureteroscopy was performed in three porcine subjects with a prototype ureteroscope containing a temperature sensor at its tip. A needle with four thermocouples was introduced percutaneously into a kidney with ultrasound guidance to allow temperature measurement in the renal medulla and cortex. Three trials of laser activation (40W) for 60 s were conducted with an irrigation rate of 8 ml/min at room temperature in each subject. After euthanasia, three trials were repeated without vascular perfusion in each subject. RESULTS: Substantial temperature elevation was observed in the renal medulla with thermal dose in two of nine trials exceeding threshold for tissue injury. The temperature decay time (t½) of the non-perfused trials was longer than in the perfused trials. The ratio of t½ between them was greater in the cortex than the medulla. CONCLUSION: High-power laser settings (40W) can induce potentially injurious temperatures in the in vivo porcine kidney, particularly in the medullary region adjacent to the collecting system. Additionally, the influence of vascular perfusion in mitigating thermal risk in this susceptible area appears to be limited.


Subject(s)
Lasers, Solid-State , Lithotripsy, Laser , Swine , Animals , Humans , Temperature , Hot Temperature , Kidney , Ureteroscopy , Perfusion
8.
J Acoust Soc Am ; 155(2): 1406-1421, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38364040

ABSTRACT

Quantitative analysis of radio frequency (RF) signals obtained from ultrasound scanners can yield objective parameters that are gaining clinical relevance as imaging biomarkers. These include the backscatter coefficient (BSC) and the effective scatterer diameter (ESD). Biomarker validation is typically performed in phantoms which do not provide the flexibility of systematic variation of scattering properties. Computer simulations, such as those from the ultrasound simulator Field II, can allow more flexibility. However, Field II does not allow simulation of RF data from a distribution of scatterers with finite size. In this work, a simulation method is presented which builds upon previous work by including Faran theory models representative of distributions of scatterer size. These are systematically applied to RF data simulated in Field II. The method is validated by measuring the root mean square error of the estimated BSC and percent bias of the ESD and comparing to experimental results. The results indicate the method accurately simulates distributions of scatterer sizes and provides scattering similar to that seen in data from clinical scanners. Because Field II is widely used by the ultrasound community, this method can be adopted to aid in validation of quantitative ultrasound imaging biomarkers.

9.
J Biomech Eng ; 146(8)2024 08 01.
Article in English | MEDLINE | ID: mdl-38270929

ABSTRACT

Cervical remodeling is critical for a healthy pregnancy. Premature tissue changes can lead to preterm birth (PTB), and the absence of remodeling can lead to post-term birth, causing significant morbidity. Comprehensive characterization of cervical material properties is necessary to uncover the mechanisms behind abnormal cervical softening. Quantifying cervical material properties during gestation is challenging in humans. Thus, a nonhuman primate (NHP) model is employed for this study. In this study, cervical tissue samples were collected from Rhesus macaques before pregnancy and at three gestational time points. Indentation and tension mechanical tests were conducted, coupled with digital image correlation (DIC), constitutive material modeling, and inverse finite element analysis (IFEA) to characterize the equilibrium material response of the macaque cervix during pregnancy. Results show, as gestation progresses: (1) the cervical fiber network becomes more extensible (nonpregnant versus pregnant locking stretch: 2.03 ± 1.09 versus 2.99 ± 1.39) and less stiff (nonpregnant versus pregnant initial stiffness: 272 ± 252 kPa versus 43 ± 43 kPa); (2) the ground substance compressibility does not change much (nonpregnant versus pregnant bulk modulus: 1.37 ± 0.82 kPa versus 2.81 ± 2.81 kPa); (3) fiber network dispersion increases, moving from aligned to randomly oriented (nonpregnant versus pregnant concentration coefficient: 1.03 ± 0.46 versus 0.50 ± 0.20); and (4) the largest change in fiber stiffness and dispersion happen during the second trimester. These results, for the first time, reveal the remodeling process of a nonhuman primate cervix and its distinct regimes throughout the entire pregnancy.


Subject(s)
Cervix Uteri , Premature Birth , Animals , Female , Pregnancy , Extracellular Matrix , Finite Element Analysis , Macaca mulatta
10.
Int J Hyperthermia ; 41(1): 2297650, 2024.
Article in English | MEDLINE | ID: mdl-38214171

ABSTRACT

Histotripsy is the first noninvasive, non-ionizing, and non-thermal ablation technique that mechanically fractionates target tissue into acellular homogenate via controlled acoustic cavitation. Histotripsy has been evaluated for various preclinical applications requiring noninvasive tissue removal including cancer, brain surgery, blood clot and hematoma liquefaction, and correction of neonatal congenital heart defects. Promising preclinical results including local tumor suppression, improved survival outcomes, local and systemic anti-tumor immune responses, and histotripsy-induced abscopal effects have been reported in various animal tumor models. Histotripsy is also being investigated in veterinary patients with spontaneously arising tumors. Research is underway to combine histotripsy with immunotherapy and chemotherapy to improve therapeutic outcomes. In addition to preclinical cancer research, human clinical trials are ongoing for the treatment of liver tumors and renal tumors. Histotripsy has been recently approved by the FDA for noninvasive treatment of liver tumors. This review highlights key learnings from in vivo shock-scattering histotripsy, intrinsic threshold histotripsy, and boiling histotripsy cancer studies treating cancers of different anatomic locations and discusses the major considerations in planning in vivo histotripsy studies regarding instrumentation, tumor model, study design, treatment dose, and post-treatment tumor monitoring.


Subject(s)
High-Intensity Focused Ultrasound Ablation , Kidney Neoplasms , Liver Neoplasms , Animals , Infant, Newborn , Humans , High-Intensity Focused Ultrasound Ablation/methods , Models, Animal , Research Design
11.
IEEE Trans Biomed Eng ; 71(2): 467-476, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37607156

ABSTRACT

Most therapeutic ultrasound devices place emitters and receivers in separate locations, so that the long therapeutic pulses (>1 ms) can be emitted while receivers monitor the procedure. However, with such placement, emitters and receivers are competing for the same space, producing a trade-off between emission efficiency and reception sensitivity. Taking advantage of recent studies demonstrating that short-pulse ultrasound can be used therapeutically, we aimed to develop a device that overcomes such trade-offs. The array was composed of emitter-receiver stacks, which enabled both emission and reception from the same location. Each element was made of a lead zirconate titanate (PZT)-polyvinylidene fluoride (PVDF) stack. The PZT (frequency: 500 kHz, diameter: 16 mm) was used for emission and the PVDF (thickness: 28 µm, diameter: 16 mm) for broadband reception. 32 elements were assembled in a 3D-printed dome-shaped frame (focal length: 150 mm; [Formula: see text]-number: 1) and was tested in free-field and through an ex-vivo human skull. In free-field, the array had a 4.5 × 4.5 × 32 mm focus and produced a peak-negative pressure (PNP) of 2.12 MPa at its geometric center. The electronic steering range was ±15 mm laterally and larger than ±15 mm axially. Through the skull, the array produced a PNP of 0.63 MPa. The PVDF elements were able to localize broadband microbubble emissions across the skull. We built the first multi-element array for short-pulse and microbubble-based therapeutic applications. Stacked arrays overcome traditional trade-offs between the transmission and reception quality and have the potential to create a step change in treatment safety and efficacy.


Subject(s)
Fluorocarbon Polymers , Microbubbles , Ultrasonic Therapy , Humans , Ultrasonography , Ultrasonic Therapy/methods , Polyvinyls
12.
IEEE Trans Biomed Eng ; 71(1): 367-374, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37590110

ABSTRACT

OBJECTIVE: Ultrasound elasticity imaging is a class of ultrasound techniques with applications that include the detection of malignancy in breast lesions. Although elasticity imaging traditionally assumes linear elasticity, the large strain elastic response of soft tissue is known to be nonlinear. This study evaluates the nonlinear response of breast lesions for the characterization of malignancy using force measurement and force-controlled compression during ultrasound imaging. METHODS: 54 patients were recruited for this study. A custom force-instrumented compression device was used to apply a controlled force during ultrasound imaging. Motion tracking derived strain was averaged over lesion or background ROIs and matched with compression force. The resulting force-matched strain was used for subsequent analysis and curve fitting. RESULTS: Greater median differences between malignant and benign lesions were observed at higher compressional forces (p-value < 0.05 for compressional forces of 2-6N). Of three candidate functions, a power law function produced the best fit to the force-matched strain. A statistically significant difference in the scaling parameter of the power function between malignant and benign lesions was observed (p-value = 0.025). CONCLUSIONS: We observed a greater separation in average lesion strain between malignant and benign lesions at large compression forces and demonstrated the characterization of this nonlinear effect using a power law model. Using this model, we were able to differentiate between malignant and benign breast lesions. SIGNIFICANCE: With further development, the proposed method to utilize the nonlinear elastic response of breast tissue has the potential for improving non-invasive lesion characterization for potential malignancy.


Subject(s)
Breast Neoplasms , Elasticity Imaging Techniques , Humans , Female , Elasticity Imaging Techniques/methods , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/pathology , Elasticity , Ultrasonography, Mammary/methods , Diagnosis, Differential , Sensitivity and Specificity
13.
Hum Mol Genet ; 33(5): 465-474, 2024 Feb 18.
Article in English | MEDLINE | ID: mdl-37988592

ABSTRACT

Whole genome sequencing (WGS) from large clinically unselected cohorts provides a unique opportunity to assess the penetrance and expressivity of rare and/or known pathogenic mitochondrial variants in population. Using WGS from 179 862 clinically unselected individuals from the UK Biobank, we performed extensive single and rare variant aggregation association analyses of 15 881 mtDNA variants and 73 known pathogenic variants with 15 mitochondrial disease-relevant phenotypes. We identified 12 homoplasmic and one heteroplasmic variant (m.3243A>G) with genome-wide significant associations in our clinically unselected cohort. Heteroplasmic m.3243A>G (MAF = 0.0002, a known pathogenic variant) was associated with diabetes, deafness and heart failure and 12 homoplasmic variants increased aspartate aminotransferase levels including three low-frequency variants (MAF ~0.002 and beta~0.3 SD). Most pathogenic mitochondrial disease variants (n = 66/74) were rare in the population (<1:9000). Aggregated or single variant analysis of pathogenic variants showed low penetrance in unselected settings for the relevant phenotypes, except m.3243A>G. Multi-system disease risk and penetrance of diabetes, deafness and heart failure greatly increased with m.3243A>G level ≥ 10%. The odds ratio of these traits increased from 5.61, 12.3 and 10.1 to 25.1, 55.0 and 39.5, respectively. Diabetes risk with m.3243A>G was further influenced by type 2 diabetes genetic risk. Our study of mitochondrial variation in a large-unselected population identified novel associations and demonstrated that pathogenic mitochondrial variants have lower penetrance in clinically unselected settings. m.3243A>G was an exception at higher heteroplasmy showing a significant impact on health making it a good candidate for incidental reporting.


Subject(s)
Deafness , Diabetes Mellitus, Type 2 , Heart Failure , Mitochondrial Diseases , Humans , Penetrance , Diabetes Mellitus, Type 2/genetics , DNA, Mitochondrial/genetics , Mitochondrial Diseases/genetics , Deafness/genetics , Mutation
14.
Sci Rep ; 13(1): 19237, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37935776

ABSTRACT

Resonant Acoustic Rheometry (RAR), a newly developed ultrasound-based technique for non-contact characterization of soft viscoelastic materials, has shown promise for quantitative viscoelastic assessment of temporally changing soft biomaterials in real time, and may be used to monitor blood coagulation process. Here, we report the development of a novel, multichannel RAR (mRAR) system for simultaneous measurements of multiple temporally evolving samples and demonstration of its use for monitoring the coagulation of multiple small-volume plasma samples. The mRAR system was constructed using an array of 4 custom-designed ultrasound transducers at 5.0 MHz and a novel electronic driving system that controlled the generation of synchronized ultrasound pulses for real time assessment of multiple samples simultaneously. As a proof-of-concept of the operation of the mRAR system, we performed tests using pooled normal human plasma samples and anti-coagulated plasma samples from patients treated with warfarin with a range of International Normalized Ratio (INR) values as well-characterized samples with different coagulation kinetics. Our results show that simultaneous tracking of dynamic changes in 4 plasma samples triggered by either kaolin or tissue factor was achieved for the entire duration of coagulation. The mRAR system captured distinct changes in the samples and identified parameters including the clotting start time and parameters associated with the stiffness of the final clots that were consistent with INR levels. Data from this study demonstrate the feasibility of the mRAR system for efficient characterization of the kinetic coagulation processes of multiple plasma samples.


Subject(s)
Blood Coagulation , Thrombosis , Humans , Blood Coagulation Tests/methods , International Normalized Ratio , Warfarin , Acoustics
15.
J Water Health ; 21(10): 1580-1590, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37902211

ABSTRACT

Cryptosporidium spp. are protozoan parasites of significant health importance found in environmental waters globally. Four commercially available Cryptosporidium-specific immunomagnetic separation (IMS) kits used in various water sample matrices were analysed and compared. Beads were characterised by flow cytometry and tested for the recovery efficiencies for oocysts spiked into different matrices: river water sediment, clay sample, and filter backwash sample. Results showed that Dynabeads™ Cryptosporidium and Waterborne Crypto-Grab™ kits contained immunoglobulin IgM antibody-coated beads. In contrast, the BioPoint CryptoBead and the TCS Isolate kits contained immunoglobulin IgG antibody-coated beads. BioPoint CryptoBead was significantly coated with more antibodies and were able to capture oocysts more rapidly compared to the other beads. Recovery efficiencies of Dynabeads™, TCS Isolate® beads, and BioPoint CryptoBead ranged from 55 to 93% when tested against different sample matrices, with BioPoint CryptoBead resulting in the highest at 93% in reagent-grade water and Dynabeads™ at 55%, the lowest against clay samples. The Waterborne beads did not perform well on any samples, with recovery efficiencies ranging from 0 to 8%. Fluorescence microscopy analyses showed that both the IMS method and the sample matrix processed affect the quality of the membranes, with the cleanest samples for microscopy examination observed from BioPoint CryptoBead.


Subject(s)
Cryptosporidiosis , Cryptosporidium , Animals , Immunomagnetic Separation/methods , Clay , Water/parasitology , Oocysts , Immunoglobulins
16.
Phys Med Biol ; 68(22)2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37797649

ABSTRACT

Histotripsy is a non-thermal focused ultrasound ablation method that destroys tissue through the generation and activity of acoustic cavitation bubble clouds. Intrinsic threshold histotripsy uses single-cycle pulses to generate bubble clouds when the dominant negative pressure phase exceeds an intrinsic threshold of ∼25-30 MPa. The ablation efficiency is dependent upon the size and density of bubbles within the bubble cloud. This work investigates the effects of dual-frequency pulsing schemes on the bubble cloud behavior and ablation efficiency in intrinsic threshold histotripsy. A modular 500 kHz:3 MHz histotripsy transducer treated agarose phantoms using dual-frequency histotripsy pulses with a 1:1 pressure ratio from 500 kHz and 3 MHz frequency elements and varying arrival times for the 3 MHz pulse relative to the arrival of the 500 kHz pulse (-100 ns, 0 ns, and +100 ns). High-speed optical imaging captured cavitation effects to characterize bubble cloud and individual bubble dynamics. The effects of dual-frequency pulsing on lesion formation and ablation efficiency were also investigated in red blood cell (RBC) phantoms. Results showed that the single bubble and bubble cloud size for dual-frequency cases were intermediate to published results for the component single-frequencies of 500 kHz and 3 MHz. Additionally, bubble cloud size and dynamics were shown to be altered by the arrival time of the 3 MHz pulse with respect to the 500 kHz pulse, with more uniform cloud expansion and collapse observed for early (-100 ns) arrival. Finally, RBC phantom experiments showed that dual-frequency exposures were capable of generating precise lesions with smaller areas and higher ablation efficiencies than previously published results for 500 kHz or 3 MHz. Overall, results demonstrate dual-frequency histotripsy's ability to modulate bubble cloud size and dynamics can be leveraged to produce precise lesions at higher ablation efficiencies than previously observed for single-frequency pulsing.


Subject(s)
High-Intensity Focused Ultrasound Ablation , Lithotripsy , High-Intensity Focused Ultrasound Ablation/methods , Lithotripsy/methods , Phantoms, Imaging , Transducers , Erythrocytes
17.
Biol Lett ; 19(10): 20230202, 2023 10.
Article in English | MEDLINE | ID: mdl-37817576

ABSTRACT

Animals are faced with a variety of dangers or threats, which are increasing in frequency with ongoing environmental change. While our understanding of fearfulness of such dangers is growing in the context of predation and parasitism risk, the extent to which non-trophic, interspecific dangers elicit fear in animals remains less appreciated. We provide an experimental test for fear responses of savannah ungulates to a dominant and aggressive megaherbivore, the African bush elephant (Loxodonta africana), and contrast responses to an apex predator known to elicit fear in this system. Using an automated behavioural response system, we contrast vigilance and run responses of ungulates to elephant, leopard (Panthera pardus), and control (red-chested cuckoo Cuculus solitarius) vocalizations. Overall, we find that ungulates responded to elephant calls, both in terms of an increase in run and vigilance responses relative to controls. The magnitude of most behavioural responses (four of six considered) to elephant vocalizations were not significantly different than responses to leopards. These results suggest that megaherbivores can elicit strong non-trophic fear responses by ungulates and call to broaden frameworks on fear to consider dominant species, such as megaherbivores, as key modifiers of fear-induced interactions.


Subject(s)
Elephants , Animals , Elephants/physiology , Mammals , Predatory Behavior , Fear , Aggression , Birds
18.
Int J Hyperthermia ; 40(1): 2266594, 2023.
Article in English | MEDLINE | ID: mdl-37813397

ABSTRACT

In transabdominal histotripsy, ultrasound pulses are focused on the body to noninvasively destroy soft tissues via cavitation. However, the ability to focus is limited by phase aberration, or decorrelation of the ultrasound pulses due to spatial variation in the speed of sound throughout heterogeneous tissue. Phase aberration shifts, broadens, and weakens the focus, thereby reducing the safety and efficacy of histotripsy therapy. This paper reviews and discusses aberration effects in histotripsy and in related therapeutic ultrasound techniques (e.g., high intensity focused ultrasound), with an emphasis on aberration by soft tissues. Methods for aberration correction are reviewed and can be classified into two groups: model-based methods, which use segmented images of the tissue as input to an acoustic propagation model to predict and compensate phase differences, and signal-based methods, which use a receive-capable therapy array to detect phase differences by sensing acoustic signals backpropagating from the focus. The relative advantages and disadvantages of both groups of methods are discussed. Importantly, model-based methods can correct focal shift, while signal-based methods can restore substantial focal pressure, suggesting that both methods should be combined in a 2-step approach. Aberration correction will be critical to improving histotripsy treatments and expanding the histotripsy treatment envelope to enable non-invasive, non-thermal histotripsy therapy for more patients.


Subject(s)
High-Intensity Focused Ultrasound Ablation , Humans , High-Intensity Focused Ultrasound Ablation/methods , Ultrasonography , Sound , Microbubbles , Phantoms, Imaging
19.
Ann Glob Health ; 89(1): 70, 2023.
Article in English | MEDLINE | ID: mdl-37841804

ABSTRACT

Background: Surgical volume is a surgical indicator that was described in the Lancet Commission on Global Surgery (LCoGS) and the World Bank World Development Indicators as an important metric for tracking the delivery of surgical care. Objectives: We aimed to characterize the reports on surgical volume (SV) in the existing literature by using a systematic review to assess studies that examine surgical procedures as a ratio of a population (procedures/100,000 population). Methods: The PRISMA guideline was employed in the systematic review of articles that addressed the measurement of SV in low- and middle-income countries (LMICs), with the primary outcome of surgical procedures/100,000 population. Findings: The search result consisted of 6,657 preliminary studies. Following the title and abstract screening, 6,464 articles were excluded, and the remaining 193 were included in the full text review. From the full text review of the 193, only 26 of these articles defined SV as the ratio of number of procedures per population of the catchment/geographical area. The reported SV was a mean of 765, with an SD of 1260 operations per 100,000. The median SV was 180 (min = 0.900, max = 4470). Conclusion: Our findings support the LCoGS assessment of the gap in surgical care. The target for SV is 5000 per 100,000 population, compared to the average of 765 per 100,000 population as found in this review. The challenges for assessing surgical volume gaps are vast, including the nature of written records, which limits SV reports to an absolute number of procedures per year without a reference to the catchment population. For the purpose of tracking SV, we recommend using proxies that account for the capacity of facilities to deliver care regardless of the catchment population.


Subject(s)
Developing Countries , Surgical Procedures, Operative , Humans , Surgical Procedures, Operative/statistics & numerical data
20.
Cancers (Basel) ; 15(17)2023 Aug 23.
Article in English | MEDLINE | ID: mdl-37686495

ABSTRACT

In a digital image, each voxel contains quantitative information dependent on the technique used to generate the image [...].

SELECTION OF CITATIONS
SEARCH DETAIL
...