Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
Auris Nasus Larynx ; 48(4): 738-744, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33384180

ABSTRACT

OBJECTIVE: A system enabling the objective assessment of the transmission of voice sounds to the external auditory canal (EAC) during phonation has recently been revised. Our aim was to evaluate the effectiveness of this new system in the diagnosis of patulous Eustachian tube (PET) patients by comparing the results obtained using this method with those obtained from conventional objective tests to diagnose PET. METHODS: A prospective survey of medical records was included with definite PET, possible PET, and sensorineural hearing loss as control. The measurement system consists of a personal computer, an AD/DA converter (NI 6361, National Instruments), a probe microphone system for recording voice sound (ER-10C, Etymotic Research) and two microphones for measuring noise sound in the EAC (ER-10B+, Etymotic Research). Pronouncing the "Ni" sound for 5 s were recorded with these three microphones. The ratio of the maximum sound pressure of voice sound and noise sound in EAC (EAC/Voice) was simultaneously calculated, and results were displayed on a personal computer for diagnosing. RESULTS: Thirty-one patients of 42 ears with definite PET, 26 patients of 38 ears with possible PET, and 12 patients of 24 ears with sensorineural hearing loss as control were included. The EAC/Voice were 8.63 ± 5.43, 25.41 ± 32.63, and 25.87 ± 24.93 in the control, definite PET, and possible PET group respectively. The control group was significantly different from the definite PET (p < 0.05) and possible PET group (p < 0.05). ROC curve analysis confirmed 14.7 as the best diagnostic cut-off value of EAC/Voice (area under the curve=0.782, 95% CI 0.671-0.894). By adopting this cut-off point, 25 (56.8%) and 22 (61.1%) ears were determined as positive findings in the definite PET and possible PET group, respectively. There was no significant correlation between the positive findings judged by the current method and that of sonotubometry in the control (r = -0.63, p = 0.769), definite PET (r = 0.12, p = 0.451), and possible PET group (r = 0.12, p = 0.451). CONCLUSION: The current system is more useful in the objective assessment of autophony during phonation by calculating the ratio of voice sound and elicited noise sound transmitted in the EAC (EAC/Voice). This method seems promising because it is able to detect cases eluding conventionally used test methods such as sonotubometry performed without phonation, thereby increasing the accuracy of PET diagnoses.


Subject(s)
Ear Diseases/diagnosis , Eustachian Tube/pathology , Hearing Disorders/etiology , Phonation , Voice/physiology , Adult , Aged , Case-Control Studies , Ear Canal , Ear Diseases/complications , Ear Diseases/physiopathology , Female , Hearing Loss, Sensorineural/physiopathology , Hearing Tests , Humans , Male , Middle Aged , Prospective Studies , ROC Curve , Sound , Young Adult
2.
Int J Pediatr Otorhinolaryngol ; 134: 110061, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32387706

ABSTRACT

OBJECTIVES: Neonates have smaller and less mature ears than adults. Developmental changes in structure and function continually occur after birth and may affect the diagnostic results obtained by audiometric assessment instrumentation, such as tympanometry and otoacoustic emission. In the present study, we investigated longitudinal changes in external and middle ear dynamic characteristics by performing sweep frequency impedance (SFI) tests. METHODS: SFI tests were longitudinally performed on healthy Japanese neonates (1 female and 1 male) from birth to 3 and 5 months, respectively. A sound of sweeping sinusoidal frequency, ranging from 0.1 kHz to 2 kHz, was presented to the ear canal at 50-daPa intervals of static pressure from +200 to -200 daPa. Test results were expressed a curve showing the sound pressure level (SPL) relative to probe tone frequency, called SPL curve. RESULTS: The first fluctuation in resonance frequency (RF1) and SPL (ΔSPL1), related to the external ear, showed significant developmental changes as chronological age increased; that is, RF1 and ΔSPL1 were respectively increased and decreased and thereafter became unmeasurable by 5 months of age. In contrast, the second fluctuation in resonance frequency (RF2) and SPL (ΔSPL2), related to the middle ear, did not show significant changes over the measurement period. CONCLUSIONS: The present results suggest that the dynamic characteristics of the external ear canal wall changed with increases in chronological age; the resonance of the wall at about 0.3 kHz at birth tended to increase to about 0.7 kHz and to be unmeasurable by 5 months of age, while those of the middle ear did not significantly changed. These results showing how neonatal-ear dynamics changes with chronological age may be an important key in further hearing research and the development of hearing devices and diagnostic tools suitable for neonates.


Subject(s)
Aging/physiology , Child Development/physiology , Ear, External/physiology , Ear, Middle/physiology , Electric Impedance , Female , Humans , Infant , Infant, Newborn , Longitudinal Studies , Male , Sound
3.
Int J Pediatr Otorhinolaryngol ; 77(4): 504-12, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23312352

ABSTRACT

OBJECTIVE: Early diagnosis and treatment of hearing disorders in neonates is highly effective for realization of linguistic competence and intellectual development. To objectively and quickly evaluate the dynamic characteristics of the middle ear, a sweep frequency impedance (SFI) meter was developed, which allowed the diagnosis of middle-ear dysfunctions in adults and children. However, this SFI meter was not applicable to neonates since the size of the measurement probe was too large. In the present study, therefore, the SFI meter was improved, i.e., the diameter of the probe was reduced to that of the neonatal external ear canal. By using this newly designed SFI meter, SFI tests were performed in healthy neonates. METHODS: A sound of the sweeping sinusoidal frequency between 0.1 kHz and 2.0 kHz in 0.02-kHz step intervals is presented to the ear canal by an SFI probe while the static pressure of the ear canal is kept constant. During this procedure, the sound pressure level (SPL) is measured. The measurements are performed at 50-daPa intervals of static pressure from 200 daPa to -200 daPa. RESULTS: Measurements were conducted in 10 ears of 9 neonates. The SPL showed two variations at 0.26 ± 0.03 kHz and 1.13 ± 0.12 kHz. Since the SPL is known to show a variation at frequencies from 1.0 kHz to 1.6 kHz due to the resonance of the middle ear in adults and children with normal hearing, the second variation is probably related to such resonance in neonates. The measurement of gel models, which mimics the neonatal external ear canal, showed a variation in SPL at around 0.5 kHz. This implies that the source of the first variation may possibly be related to the resonance of the external ear canal wall. CONCLUSIONS: SFI tests revealed that there were two variations in the SPL curve in neonates, one at 0.26 ± 0.03 kHz and the other at 1.13 ± 0.12 kHz, the former and the latter being possibly related to the resonance of the external ear canal wall and that of the middle ear, respectively. This result suggests that the dynamic characteristics of the middle ear in neonates are different from those in adults.


Subject(s)
Acoustic Impedance Tests/methods , Ear Canal/physiopathology , Ear, Middle/physiopathology , Hearing Disorders/diagnosis , Adult , Female , Humans , Infant, Newborn , Male
4.
Proc Natl Acad Sci U S A ; 108(45): 18390-5, 2011 Nov 08.
Article in English | MEDLINE | ID: mdl-22025702

ABSTRACT

Cochlear hair cells convert sound vibration into electrical potential, and loss of these cells diminishes auditory function. In response to mechanical stimuli, piezoelectric materials generate electricity, suggesting that they could be used in place of hair cells to create an artificial cochlear epithelium. Here, we report that a piezoelectric membrane generated electrical potentials in response to sound stimuli that were able to induce auditory brainstem responses in deafened guinea pigs, indicating its capacity to mimic basilar membrane function. In addition, sound stimuli were transmitted through the external auditory canal to a piezoelectric membrane implanted in the cochlea, inducing it to vibrate. The application of sound to the middle ear ossicle induced voltage output from the implanted piezoelectric membrane. These findings establish the fundamental principles for the development of hearing devices using piezoelectric materials, although there are many problems to be overcome before practical application.


Subject(s)
Basilar Membrane/physiology , Cochlea/physiology , Acoustic Stimulation , Animals , Basilar Membrane/drug effects , Cochlea/drug effects , Electronics , Ethacrynic Acid/pharmacology , Evoked Potentials, Auditory, Brain Stem , Female , Guinea Pigs , Kanamycin/pharmacology
5.
Otol Neurotol ; 27(5): 600-3, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16868508

ABSTRACT

OBJECTIVE: To investigate the contribution of anatomical factors, such as the caliber of the patent eustachian tube (ET) and the volume of the middle ear cavity, on vocalized sound transmission to the inner ear. METHODS: Model experiment using artificial middle ear. RESULTS: In the present model experiment, sound transmission from the pharynx to the inner ear under patulous conditions was affected by the caliber of the ET and by the mastoid volume, especially in the low-frequency region, that is, a larger caliber of the ET and smaller mastoid volume resulted in greater sound transmission from the pharyngeal space to the inner ear. CONCLUSION: Patulous symptoms may be more distressful in patients with poorly developed mastoid cavity than in those with well-aerated mastoid under similar conditions of patulous ET.


Subject(s)
Auditory Perception/physiology , Ear, Middle/physiology , Eustachian Tube/physiology , Adult , Biomechanical Phenomena , Ear Canal/physiology , Ear, Middle/anatomy & histology , Eustachian Tube/anatomy & histology , Eustachian Tube/pathology , Humans , Mastoid/anatomy & histology , Mastoid/physiology , Models, Anatomic , Pharynx/physiology , Stapes/physiology
SELECTION OF CITATIONS
SEARCH DETAIL