Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
Add more filters










Publication year range
1.
Sci Rep ; 14(1): 16396, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39013921

ABSTRACT

Most of the conditions involving cartilaginous tissues are irreversible and involve degenerative processes. The aim of the present study was to fabricate a biocompatible fibrous and film scaffolds using electrospinning and casting techniques to induce chondrogenic differentiation for possible application in cartilaginous tissue regeneration. Polycaprolactone (PCL) electrospun nanofibrous scaffolds and PCL film were fabricated and incorporated with multi-walled carbon nanotubes (MWCNTs). Thereafter, coating of chondroitin sulfate (CS) on the fibrous and film structures was applied to promote chondrogenic differentiation of human dental pulp stem cells (hDPSCs). First, the morphology, hydrophilicity and mechanical properties of the scaffolds were characterized by scanning electron microscopy (SEM), spectroscopic characterization, water contact angle measurements and tensile strength testing. Subsequently, the effects of the fabricated scaffolds on stimulating the proliferation of human dental pulp stem cells (hDPSCs) and inducing their chondrogenic differentiation were evaluated via electron microscopy, flow cytometry and RT‒PCR. The results of the study demonstrated that the different forms of the fabricated PCL-MWCNTs scaffolds analyzed demonstrated biocompatibility. The nanofilm structures demonstrated a higher rate of cellular proliferation, while the nanofibrous architecture of the scaffolds supported the cellular attachment and differentiation capacity of hDPSCs and was further enhanced with CS addition. In conclusion, the results of the present investigation highlighted the significance of this combination of parameters on the viability, proliferation and chondrogenic differentiation capacity of hDPSCs seeded on PCL-MWCNT scaffolds. This approach may be applied when designing PCL-based scaffolds for future cell-based therapeutic approaches developed for chondrogenic diseases.


Subject(s)
Cell Differentiation , Chondrogenesis , Chondroitin Sulfates , Dental Pulp , Nanofibers , Nanotubes, Carbon , Polyesters , Stem Cells , Tissue Scaffolds , Humans , Dental Pulp/cytology , Chondroitin Sulfates/chemistry , Chondroitin Sulfates/pharmacology , Polyesters/chemistry , Polyesters/pharmacology , Nanofibers/chemistry , Cell Differentiation/drug effects , Chondrogenesis/drug effects , Stem Cells/cytology , Stem Cells/drug effects , Stem Cells/metabolism , Tissue Scaffolds/chemistry , Nanotubes, Carbon/chemistry , Cell Proliferation/drug effects , Cells, Cultured , Tissue Engineering/methods
2.
BMC Oral Health ; 24(1): 739, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38937723

ABSTRACT

BACKGROUND: In dentistry, glass-ionomer cements (GICs) are extensively used for a range of applications. The unique properties of GIC include fluoride ion release and recharge, chemical bonding to the tooth's hard tissues, biocompatibility, a thermal expansion coefficient like that of enamel and dentin, and acceptable aesthetics. Their high solubility and poor mechanical qualities are among their limitations. E-glass fibers are generally utilized to reinforce the polymer matrix and are identified by their higher silica content. OBJECTIVES: The purpose of the study was to assess the impact of adding (10 wt% and 20 wt%) silane-treated E-glass fibers to traditional GIC on its mechanical properties (compressive strength, flexural strength, and surface hardness) and solubility. METHODS: The characterization of the E-glass fiber fillers was achieved by XRF, SEM, and PSD. The specimens were prepared by adding the E-glass fiber fillers to the traditional GIC at 10% and 20% by weight, forming two innovative groups, and compared with the unmodified GIC (control group). The physical properties (film thickness and initial setting time) were examined to confirm operability after mixing. The evaluation of the reinforced GIC was performed by assessing the compressive strength, flexural strength, hardness, and solubility (n = 10 specimens per test). A one-way ANOVA and Tukey tests were performed for statistical analysis (p ≤ 0.05). RESULTS: The traditional GIC showed the least compressive strength, flexural strength, hardness, and highest solubility. While the GIC reinforced with 20 wt% E-glass fibers showed the highest compressive strength, flexural strength, hardness, and least solubility. Meanwhile, GIC reinforced with 10 wt% showed intermediate results (P ≤ 0.05). CONCLUSION: Using 20 wt% E-glass fiber as a filler with the traditional GIC provides a strengthening effect and reduced solubility.


Subject(s)
Compressive Strength , Flexural Strength , Glass Ionomer Cements , Glass , Hardness , Materials Testing , Solubility , Glass Ionomer Cements/chemistry , Glass/chemistry , Surface Properties , Silanes/chemistry , Microscopy, Electron, Scanning , Dental Stress Analysis , Pliability , Humans
3.
BMC Oral Health ; 24(1): 487, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658909

ABSTRACT

BACKGROUND: Zinc-oxide eugenol (ZOE) cements are among the most used temporary materials in dentistry. Although ZOE has advantages over other temporary fillers, its mechanical strength is weaker, so researchers are working to improve it. E-glass fibers have emerged as promising reinforcing fibers in recent years due to their strong mechanical behavior, adequate bonding, and acceptable aesthetics. OBJECTIVES: To evaluate and compare the compressive strength, surface microhardness, and solubility of the ZOE and those reinforced with 10 wt.% E-glass fibers. METHODS: A total of 60 ZEO specimens were prepared; 30 specimens were reinforced with 10 wt.% E-glass fibers, considered modified ZOE. The characterization of the E-glass fibers was performed by XRF, SEM, and PSD. The compressive strength, surface microhardness, and solubility were evaluated. Independent sample t-tests were used to statistically assess the data and compare mean values (P ≤ 0.05). RESULTS: The results revealed that the modified ZOE showed a significantly higher mean value of compressive strength and surface microhardness while having a significantly lower mean value of solubility compared to unmodified ZOE (P ≤ 0.05). CONCLUSION: The modified ZOE with 10 wt.% E-glass fibers had the opportunity to be used as permanent filling materials.


Subject(s)
Compressive Strength , Glass , Hardness , Materials Testing , Solubility , Zinc Oxide-Eugenol Cement , Zinc Oxide-Eugenol Cement/chemistry , Glass/chemistry , Surface Properties , Microscopy, Electron, Scanning
4.
Head Face Med ; 20(1): 2, 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38172921

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the physicochemical properties of two newly introduced premixed calcium silicate-based root canal sealers (AH Plus Bioceramic Sealer and Bio-C Sealer) compared to a resin-based root canal sealer (ADseal root canal sealer). METHODS: Solubility, pH analysis, calcium ion release, and film thickness of each sealer were evaluated following ISO guidelines. The data were examined using the two-way ANOVA test. Furthermore, X-ray diffraction (XRD) examination was performed to investigate the crystalline phase of each type of sealer. X-ray fluorescence (XRF) analysis was done for the chemical elemental analysis of each sealer. RESULTS: The least film thickness, highest alkalinity, and highest calcium ion release were all displayed by AH Plus Bioceramic Sealer. High solubility, high alkalinity, intermediate calcium ion release, and intermediate film thickness were all displayed by Bio-C Sealer. While ADseal root canal sealer displayed the greatest film thickness, least solubility, alkalinity, and calcium ion release. CONCLUSIONS: Both AH Plus Bioceramic Sealer and Bio-C Sealer represented adequate properties to be considered a good sealer that could be used as a potential alternative to resin-based root canal sealers.


Subject(s)
Calcium , Root Canal Filling Materials , Humans , Calcium/chemistry , Dental Pulp Cavity , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Calcium Compounds/chemistry , Silicates/chemistry , Materials Testing
5.
BMC Oral Health ; 24(1): 151, 2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38297290

ABSTRACT

BACKGROUND: Poly-methyl methacrylate (PMMA) is a type of polymer mostly used to make denture bases. Self-cured acrylic resin (PMMA) can be used to repair a fractured acrylic denture base; however, even after repair, this area remains vulnerable. Carbon nanotubes (CNTs) could be used as a filler for polymer reinforcement. Furthermore, silver nanoparticles are efficient agents for the prevention of dental biofilm and improving their mechanical properties. The doping of CNTs with silver nanoparticles may lead to a synergistic interaction that is predicted to enhance the mechanical characteristics of the fillers. OBJECTIVES: The aim of the study was to assess the influnce of manual incorporation of 0.5% weight percent (%wt.) of silver doped carbon nanotubes (Ag-doped CNTs) into commercial self-cured PMMA on its flexural strength, impact strength, and surface microhardness. METHODS: In this investigation, a total of 60 specimens comprised of acrylic resin were employed. They are divided into two main groups: (a) the control group, which was made by using liquid monomer and commercial self-cured PMMA powder; and (b) the modified group, prepared by hand mixing the purchased silver-doped CNTs powder (0.5% wt.) to self-cured PMMA powder (99.5%wt.), and then the blended powder was incorporated into the liquid monomer. Flexural strength, flexural modulus, impact strength, and surface microhardness were evaluated. Independent sample t-tests were used to statistically analyze the data and compare the mean values of flexural strength, flexural modulus, impact strength, and surface microhardness (p-value ≤ 0.05). RESULTS: The flexural strength of the modified groups with Ag-doped CNTs (132.4 MPa) was significantly greater than that of the unmodified (control) groups (63.2 MPa). Moreover, the flexural modulus of the modified groups with Ag-doped CNTs (3.067 GPa) was significantly greater than that of the control groups (1.47 GPa). Furthermore, the impact strength of the modified groups with Ag-doped CNTs (11.2 kJ/mm2) was significantly greater than that of the control groups (2.3 kJ/mm2). Furthermore, the microhardness of the modified groups with Ag-doped CNTs (29.7 VHN) was significantly greater than that of the control groups (16.4 VHN), (p-value = 0.0001). CONCLUSION: The incorporation of 0.5% wt. silver doped CNTs fillers to the self-cured acrylic resin enhanced its flexural strength, flexural modulus, impact strength, and surface microhardness.


Subject(s)
Metal Nanoparticles , Nanotubes, Carbon , Humans , Acrylic Resins , Polymethyl Methacrylate , Flexural Strength , Silver , Powders , Materials Testing , Denture Bases , Polymers , Surface Properties
6.
BMC Oral Health ; 23(1): 777, 2023 10 23.
Article in English | MEDLINE | ID: mdl-37872523

ABSTRACT

BACKGROUND: Conventional glass ionomer cements (GICs) are currently the most widely used dental cements due to their chemical bonding into tooth structure, release of fluoride, and ease of manipulation and usage. One of their drawbacks is their low mechanical properties and high solubility. Carbon nanotubes (CNTs) could be utilized in dentistry due to their several potential applications. CNTs can be used as fillers to reinforce polymers or other materials. Additionally, silver (Ag) nanoparticles are highly effective at preventing dental biofilm and enhancing mechanical properties. OBJECTIVES: The aim of the present in vitro study is to evaluate the compressive strength, surface microhardness, solubility, and antimicrobial effect of the conventional GIC reinforced with manual blending of 0.01 wt.% Ag doped CNT fillers. METHODS: The control group was prepared by mixing dental GIC powder with their liquid. The innovatively reinforced dental GIC group was prepared by incorporating 0.01 wt.% Ag doped CNT fillers into the GIC powder prior to liquid mixing. Chemical characterization was performed by XRF. While, physical characterization was done by measuring film thickness and initial setting time. The compressive strength, surface microhardness, solubility, and antimicrobial effect against Streptococcus mutans bacteria using an agar diffusion test were measured. The data was statistically analyzed using independent sample t-tests to compare mean values of compressive strength, surface microhardness, solubility, and antimicrobial activity (p ≤ 0.05). RESULTS: The results revealed that innovative reinforced GIC with 0.01 wt.% Ag doped CNT fillers showed higher mean compressive strength, surface microhardness, and antimicrobial effect values than the conventional GIC control group; there was no significant difference between different groups in relation to the solubility test (P ≤ 0.05). CONCLUSION: The innovatively reinforced GIC with 0.01 wt.% Ag doped CNT fillers had the opportunity to be used as an alternative to conventional GIC dental cements.


Subject(s)
Anti-Infective Agents , Nanotubes, Carbon , Humans , Compressive Strength , Silver/pharmacology , Solubility , Powders , Glass Ionomer Cements/pharmacology , Glass Ionomer Cements/chemistry , Dental Cements , Anti-Infective Agents/pharmacology , Materials Testing
7.
Sci Rep ; 13(1): 14829, 2023 09 08.
Article in English | MEDLINE | ID: mdl-37684307

ABSTRACT

This study aimed to evaluate the thermal, chemical, and physical properties of VDW.1Seal, Fill Root ST, and ADseal sealers. Thermal properties were analyzed using Thermogravimetric analysis (TGA) and Differential thermal analysis (DTA). Attenuated total reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR) analysis was performed as a complementary test to confirm TGA/DTA analysis. The chemical composition of the set sealer material was identified using an X-ray powder diffraction (XRD) system. Other physical properties of each sealer were investigated; ten specimens were used to measure the solubility (at 24 h and 28 days), and another ten specimens were used to assess pH changes and calcium ion release (after 7 and 14 days). Film thickness was done according to ISO 6876 specs. The data were analyzed using the two-way ANOVA test. Results showed that for all sealers, TGA analysis revealed a direct relationship between sealer mass loss and temperature rise. In addition, the decomposition of the tested sealers started at 145 °C, 135 °C and 91 °C for VDW.1Seal, ADseal sealer, and Fill Root ST, respectively. XRD analysis revealed a higher degree of crystallinity for VDW.1Seal and ADseal. ADseal showed the least solubility; VDW.1Seal exhibited the highest alkalinity, calcium ion release, and the lowest film thickness.


Subject(s)
Calcium , Root Canal Filling Materials , Dental Pulp Cavity , Epoxy Resins , Powders
8.
Polymers (Basel) ; 15(14)2023 Jul 17.
Article in English | MEDLINE | ID: mdl-37514457

ABSTRACT

BACKGROUND: One of the crucial factors influencing the longevity of anterior aesthetic dental restorations is the colour stability of resin composites. Bleaching and whitening have become popular methods for enhancing dental aesthetics. Home whitening techniques, such as special pens, are widely available commercially. This in vitro study aimed to determine the efficiency of a whitening pen in removing tea stains from resin composite by measuring colour differences (ΔE00). Additionally, the study aimed to evaluate the variations in colour parameters measured by extra-oral and intra-oral spectrophotometers. METHODS: A total of 45 disc-shaped resin composite specimens were randomly divided into three groups; Group 1: stored in artificial saliva (control), Group 2: stored in artificial saliva followed by a whitening pen application, and Group 3: stored in tea followed by a whitening pen application. Colour measurements were taken three times for each specimen using two spectrophotometers (extra-oral and intra-oral devices); T1: before storage (baseline), T2: after storage in artificial saliva or tea for 6 days; and T3: after one week of whitening pen application in groups 2 and 3. The data were statistically analyzed using one-way ANOVA followed by the Tukey post hoc test (p ≤ 0.05). The independent sample t-test was also employed. The equation of CIEDE2000 (ΔE00) was used to calculate the colour difference between the dry, as-prepared specimens (baseline), and those after storage or bleaching. The colour changes exceeding the acceptability threshold (∆E00 = 1.8) were considered unacceptable. RESULTS: After whitening, the colour of the specimens stored in brewed tea (Group 3) remained unacceptable, as indicated by both the extra-oral and intra-oral spectrophotometers (ΔE00 = 4 and 2.9, respectively). Groups 1 and 2 exhibited lower ΔE00 values than Group 3 (p = 0.01 *). No significant difference was observed between Group 1 (stored in artificial saliva) and Group 2 (stored in artificial saliva and then bleached) (p = 0.3). Significant differences were consistently observed between the data obtained from the extra-oral spectrophotometer and the intra-oral one. CONCLUSIONS: The whitening pen proved ineffective in removing tea stains from resin composites. Although significant differences were found between the values obtained by the two spectrophotometers (extra-oral and intra-oral), both devices confirmed the unacceptable colour of the tea-stained resin composites after whitening.

9.
Polymers (Basel) ; 15(13)2023 Jul 07.
Article in English | MEDLINE | ID: mdl-37447621

ABSTRACT

Poly (methyl methacrylate) (PMMA), is an acrylic polymer substance that is mostly used for denture base applications. The purpose of this laboratory study was to investigate the effect of adding 0.05 wt.% Ag-doped carbon nanotubes (CNT) to PMMA-based (PMMA and MMA) denture base material on the impact strength, microhardness, and antimicrobial activity. A total of 60 heat-cured acrylic resin specimens were prepared. The specimens were randomly divided into two main groups (n = 30/group), according to the powder used: (a) control group, using heat-cured PMMA; (b) treatment group, using a powder prepared by blending 0.05 wt.% silver-doped CNT nanoparticles with heat-cured PMMA. The impact strength, microhardness and anticandidal activity for each group were assessed via the Charpy, Vickers and agar diffusion tests, respectively (n = 10/test for each subgroup). Data were analyzed using independent-sample t-tests (p ≤ 0.05). The results of the impact strength test revealed that the treated heat-cured PMMA-MMA with Ag-doped CNT (2.2 kJ/mm2) was significantly higher than that of the control heat-cured PMMA (1.6 kJ/mm2). Similarly, the Vickers microhardness of the treatment group (52.7 VHN) was significantly higher than that of the control group (19.4 VHN). Regarding the agar diffusion test, after 24 h of incubation, the treated heat-cured PMMA with the Ag-doped CNT exhibited significantly higher anticandidal activity than that of the control group. Therefore, Ag-doped carbon nanotubes could be considered as promising fillers for the dental heat-cured acrylic resin to improve the resistance of the resultant denture against sudden fractures, scratching, and candida invasion.

10.
BMC Oral Health ; 23(1): 517, 2023 07 24.
Article in English | MEDLINE | ID: mdl-37488612

ABSTRACT

BACKGROUND: The aim of the current study is to assess the surface roughness of several recent nickel-titanium (Ni-Ti) rotary endodontic instruments, namely: Protaper next (PTN); Hyflex CM (CM); Hyflex EDM (EDM); WaveOne gold (WOG); and trunatomy (TN), before and after application of 5.25% sodium hypochlorite (NaOCl) irrigant solution. METHODS: In this in vitro study, five recently introduced rotary endodontic instruments of different metallurgical properties and designs were subjected to Atomic Force Microscopy (AFM) analysis, and then each file was rotated in 5.25% NaOCl for 15 min., with speed and torque according to manufacturer's instructions. The instruments were then subjected to AFM analysis again. The surface roughness average (Sa) parameter was calculated. Data were analyzed by Paired T test, One-way ANOVA and Tukey tests. RESULTS: There was a statistically significant decrease in the surface roughness of all rotary endodontic instruments after immersion in irrigants (P ≤ 0.05). CONCLUSION: The new TN and PTN instruments showed the least surface roughness. All tested Ni-Ti rotary endodontic instruments after irrigants exposure showed a varying increase in surface roughness.


Subject(s)
Nickel , Titanium , Humans , Analysis of Variance , Research Design
11.
BMC Oral Health ; 23(1): 193, 2023 04 02.
Article in English | MEDLINE | ID: mdl-37009885

ABSTRACT

BACKGROUND: The aim of this in vitro study was to evaluate push-out bond strength of different root-end filling materials using various irrigant solutions. METHODS: A push-out bond strength test was performed to evaluate the bond strength of two experimental root-end filling materials: namely, nano-hybrid mineral trioxide aggregate (MTA) and polymethyl methacrylate (PMMA) cement filled with 20% weight nano hydroxyapatite (nHA) fillers compared to conventional MTA. The irrigant solutions employed were sodium hypochlorite (NaOCl) in concentrations 1%, 2.5% and 5.25% and 2% chlorhexidine gluconate (CHX) followed by application of 17% ethylene diamine tetra-acetic acid (EDTA). A freshly extracted sixty single-rooted human maxillary central incisors were used. The crowns were removed, the canal apex was widened to simulate immature teeth. Each type of irrigation protocols was performed. After application and setting of the root-end filling materials, a slice of one mm thickness was cut transversely from the apical end of each root. Specimens were stored for 1 month in artificial saliva and were subjected to a push-out test to evaluate the shear bond strength. Data were analyzed using two-way ANOVA and Tukey test. RESULTS: The experimental nano-hybrid MTA showed the highest significant push-out bond strength values when irrigated by NaOCl at several concentrations (1%, 2.5% and 5.25%) (P< 0.05). Meanwhile, irrigation with 2% CHX resulted in highest bond strength values in nano-hybrid white MTA (18 MPa) and PMMA filled with 20% weight nHA (17.4 MPa) with nonsignificant difference between them (p = 0.25). In each root-end filling material, irrigation with 2% CHX led to the highest significant bond strength, followed by NaOCl 1%, while the least significant bond strength was produced after irrigation with NaOCl 2.5% and 5.25% (P< 0.05). CONCLUSION: Considering the limitations of this study, it may be concluded that the application of 2% CXH and 17% EDTA provides superior push-out bond strength to root canal dentin compared with irrigation with NaOCl irrigants and 17% EDTA, experimental nano-hybrid MTA root-end filling material provides enhanced shear bond strength than conventional micron-sized MTA root-end filling material.


Subject(s)
Dental Bonding , Root Canal Filling Materials , Humans , Root Canal Irrigants/chemistry , Root Canal Filling Materials/chemistry , Edetic Acid/analysis , Edetic Acid/chemistry , Polymethyl Methacrylate , Dental Pulp Cavity , Dentin/chemistry , Materials Testing , Root Canal Preparation , Sodium Hypochlorite
12.
Polymers (Basel) ; 15(4)2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36850099

ABSTRACT

BACKGROUND: Surface microhardness and color stability of dental restorative material should be sustained throughout its functional lifetime to maintain the esthetic quality of the restoration. However, the frequent application of mouthwash may affect their surface microhardness and color stability. The aim of this study was to evaluate the effects of different types of mouthwashes with different contents on surface microhardness and color stability of dental nanohybrid resin-based composite. METHODS: Disc specimens of nanohybrid resin composite (Luna Nano-Hybrid Composite) were prepared according to manufacturing instructions; specimens were incubated for 24 h in three types of mouthwash (Chlorohexidine, Listerine Green Tea, and Colgate Optic White Whitening Mouthwash). Artificial saliva was used as a control group. Surface microhardness was evaluated using Vickers microhardness device. Color stability after and before immersion in the different mouthwashes was evaluated using extra-oral spectrophotometer; the values of color change (ΔE00) were subsequently calculated. Data were analyzed using one-way ANOVA and post hoc test (p ≤ 0.05). RESULTS: There was no significant difference between microhardness of resin composite immersed in artificial saliva, CHX, and Green Tea mouthwashes (78.5, 78.4, and 73.5, respectively) (p ≥ 0.1), while the bleaching mouthwash led to the lowest microhardness of resin composite, with significant difference compared to the three previous immersion media (p = 0.002). Moreover, there were significant differences in the color changes (ΔE00) of resin composite exposed to the various immersion media (p = 0.0001). CONCLUSIONS: The bleaching mouthwash led to a significant reduction in nanohybrid resin composite's microhardness compared to the chlorohexidine and Green Tea containing mouthwashes. The resin composite's color change was accepted in bleaching mouthwash but unaccepted in chlorohexidine and Green Tea containing mouthwashes.

13.
BMC Oral Health ; 23(1): 39, 2023 01 24.
Article in English | MEDLINE | ID: mdl-36694167

ABSTRACT

BACKGROUND: Limited data is available regarding the prevalence of dental caries as a chronic disease among adolescents using different caries assessment indices. The aim of this study was to compare and describe the prevalence of dental caries among group of Egyptian students using two caries assessment indices; DMFS and ICDAS II. METHODS: This descriptive, cross-sectional epidemiological study included 2760 public secondary school students with age range from 15 to 18 years with permanent dentition and good general health. Presence of; retained teeth, congenital or developmental anomalies in the permanent dentition, orthodontic treatments, systematic conditions, smoking and general health problems were considered the exclusion criteria in this study. Participants were selected randomly from 8 public secondary schools in the Great Cairo, Egypt. The examination was achieved by 6 trained and previously calibrated examiners using sets of diagnostic mirrors, compressed air, a WHO probe and cotton rolls. DMFS index and ICDAS II system were used as caries detection methods. In DMFS index; the number of decayed (D), missing (M) and filled (F) surfaces was recorded, while in the ICDAS II index, the assessment of both cavitated and non-cavitated carious, missed and filled teeth with restorations /sealants was recorded. The examiners performed the oral examination using both scoring systems in an alternating manner. The collected data were explored for normality using Kolmogorov-Smirnov and Shapiro-Wilk tests. Chi square test was used to analyze the frequencies. RESULTS: There was a statistical significant difference between the DMFS and ICDAS II methods results regarding the recorded number of caries affected teeth and cavitated teeth surfaces. The prevalence of dental caries among the investigated secondary school students was (69.56%) and (78.29%) for DMFS and ICDAS II, respectively. CONCLUSIONS: The prevalence of dental caries among Egyptian adolescent is high. ICDAS scoring system revealed higher caries prevalence values than DMFS method. ICDAS method is the best choice for the preventive goals, while DMFS is sufficient for clinical purposes.


Subject(s)
Dental Caries , Humans , Adolescent , Dental Caries/epidemiology , Dental Caries/diagnosis , Cross-Sectional Studies , Egypt/epidemiology , Prevalence , Dental Caries Susceptibility
14.
J Funct Biomater ; 15(1)2023 Dec 28.
Article in English | MEDLINE | ID: mdl-38248679

ABSTRACT

Ceramic thickness and technicians' manipulative variables are critical factors affecting the resultant shade of dental ceramo-metallic restorations. This study investigated the effect of the following variables on shade duplication of ceramo-metallic specimens: (a) ceramic thickness; (b) differences between several technicians (inter-technician variability); and (c) the ability of each technician to repeat the resultant shade (intra-technician variability). Ninety ceramo-metallic specimens were prepared and divided into three main groups (n = 30/gp) according to the different technicians who built up the veneering ceramic of the specimens. Each group was further subdivided into three subgroups (n = 10/subgroup) according to the thickness of the ceramic (1, 1.5, and 2 mm built over a 0.5 mm-thick metal substructure). Three different technicians were asked to follow the same protocol as regards the same ceramic batch (Shade 3M2, Vita VM13, Zahnfabrik, Germany), firing temperature, and number of firing cycles. Meanwhile, each technician followed his own protocol with regard to other ceramic manipulative variables. The duplicated shades of the specimens were investigated using the Vita Easyshade spectrophotometer by using the verify shade mode. Color difference (∆E) values were calculated between the target shade (3M2) and the duplicated shades of the specimens automatically by the Vita Easyshade spectrophotometer (Vita, Zahnfabrik, Germany). The effect of ceramic thickness and inter- and intra-technician variability on the duplication of the target shade was investigated. The results showed that the effect of ceramic thickness on the duplicated shades depended on inter-technician variability. High inter-technician variability (∆E = 2-6.4) was noticed in contrast to low intra-technician variability (∆E = 0.2-1.5). It could be concluded that proper shade-duplication of ceramo-metallic restoration was a cumulative technique intimately related to manipulative variables and ceramic thickness.

15.
Polymers (Basel) ; 14(18)2022 Sep 08.
Article in English | MEDLINE | ID: mdl-36145912

ABSTRACT

BACKGROUND: Polymethyl methacrylate (PMMA) is used in fabricating acrylic denture bases. Repairing a fractured acrylic denture base can be done by self-cured PMMA, yet this is still a weak point after repair. The aim of this study was to evaluate the effect of incorporating 5% weight titanium oxide nanoparticles (TiO2) to self-cured PMMA on flexural strength, surface micro-hardness, roughness, and water sorption. METHODS: A total of 160 acrylic-resin specimens were used in this study. They were divided in two main groups; (a) control group, prepared by mixing self-cured PMMA powder to its liquid monomer, (b) treated group, prepared by blending 5% weight TiO2 nanoparticles to self-cured PMMA powder then this blend was mixed with the liquid monomer. Flexure strength, surface micro-hardness, roughness, and water sorption were evaluated. Data were analyzed using independent sample t-tests (p ≤ 0.05). RESULTS: There was a significant increase in the flexural strength of PMMA of the treated group after the addition of TiO2 (137.6 MPa) compared with the control (75.4 MPa) (p ≤ 0.001). No significant difference between the two groups in terms of micro-hardness (p = 0.385) and surface roughness (p = 0.269). Water sorption showed a significant reduction in the treated group (p ≤ 0.001). CONCLUSIONS: Addition of 5% weight TiO2 nanoparticles to the self-cured acrylic resin improved its flexural strength and reduced its water-sorption without impairing the surface micro-hardness and roughness.

16.
Polymers (Basel) ; 13(17)2021 Aug 30.
Article in English | MEDLINE | ID: mdl-34502963

ABSTRACT

BACKGROUND: Alginate impression is a common dental polymeric material, presented as powder to be mixed with water. AIM: 1. To analyze the effect of alginate powder/water ratio variation on viscosity, tear strength and detail reproduction by in vitro tests, and 2. To evaluate this variation's effect on patients' impressions. MATERIALS AND METHODS: Two commercial alginate products were mixed in different viscosities. Viscosity was measured by a viscometer. For the tear strength test, V-shaped specimens were used. For detail reproduction, a die with three scribed lines was used. Clinical dental impressions were examined by stereomicroscope. RESULTS: The alginate specimens mixed with a higher powder/water ratio showed a higher viscosity and tear strength compared to those with a lower powder/water ratio. Both alginate mixtures reproduced two scribed lines in a detail reproduction test. On the other hand, no clear clinical difference was detected when examining dental impressions mixed with a different powder/water ratio. CONCLUSION: Although increasing the powder/water ratio of mixed alginate raised the resultant viscosity and tear strength by an in vitro test, clinically, no clear difference in tearing was detected. Detail reproduction was minimally affected by the variation in powder/water ratio.

17.
Open Access Maced J Med Sci ; 7(21): 3647-3654, 2019 Nov 15.
Article in English | MEDLINE | ID: mdl-32010393

ABSTRACT

BACKGROUND: Contemporary nickel-titanium (NiTi) rotary endodontic instruments had a revolutionary impact on the success of root canal treatment. AIM: To evaluate the flexibility, microstructure and elemental analysis of four different recent NiTi rotary instruments, namely; Wave One Gold, TF adaptive, HyFlex EDM and Gr_Reciproc Blue compared to conventional Protaper Universal (F2). MATERIAL AND METHODS: The NiTi rotary files were subjected to cantilever bending test to evaluate their flexibility. The microstructural characteristics and elemental analysis were examined via scanning electron microscopy (SEM) and energy dispersive X-ray spectrometer (EDX). RESULTS: The TF adaptive, HyFlex EDM and Wave One Gold endodontic files showed significantly lower cantilever bending values (i.e., higher flexibility) than Protaper F2 and Gr_Reciproc Blue (p < 0.05). The SEM micrographs showed that the bulk of all examined files showed multiple striations due to the cutting process, on the other hand, their external surfaces were different: The Protaper Universal F2 showed multiple voids, while the TF Adaptive surface exhibited more uniform structure. The Hyflex EDM had a crater-like surface, whereas Wave one Gold showed machining grooves with minimum defects, while Reciproc Blue displayed machining grooves with random scratch lines. There was a significant difference in bulk and surface elemental analysis of the various examined files, yet composed mainly of the same elements. CONCLUSION: Chemical composition, heat treatment, manufacturing process and geometrical design of the NiTi rotary instrument have a great influence on their flexibility and microstructure.

18.
Open Access Maced J Med Sci ; 6(8): 1475-1479, 2018 Aug 20.
Article in English | MEDLINE | ID: mdl-30159080

ABSTRACT

BACKGROUND: The composition of the root canal filling materials together with the apical limit of the root canal obturation affect the complete periapical healing after root canal therapy. AIM: This study was performed to evaluate and compare the periapical healing in response to calcium-silicate (iRoot SP) and calcium-hydroxide (Apexit) based-sealers. MATERIAL AND METHODS: Seventy-two upper premolars root canals of six dogs were used. The teeth were randomly assigned to four groups: Group one: roots were obturated using gutta-percha and Apexit-sealer; Group two: roots were obturated using gutta-percha&iRoot SP-sealer; Group three: the teeth were left open without obturation; Group four: where healthy teeth were used as a negative control. Teeth were evaluated after one, two and three months. The newly formed mineralised apical tissue and the periapical inflammatory infiltrate of the obtained photomicrographs were evaluated, and scorings were statistically-analysed. RESULTS: The mean percentage of the periapical inflammatory infiltrates and mineralisation scoring after one, two and three months evaluation period were not significantly different among the four groups (P > 0.05). CONCLUSIONS: Regardless of the sealer used, iRoot SP and Apexit promote healing of periapical tissues. IRoot SP sealer showed early insignificant more partial and almost full healing after two and three months.

19.
F1000Res ; 6: 1688, 2017.
Article in English | MEDLINE | ID: mdl-29118975

ABSTRACT

Background: The newly introduced self-adhering flowable resin-composites decrease the required time for application by incorporation of an acidic adhesive monomer, thus reducing the number of steps, but its bonding is still uncertain. The aim of this study was to evaluate the interfacial microscopic examination and chemical analysis at the resin-dentin interface of a self-adhering flowable resin composite (Vertise™Flow Self-Adhering Flowable Composite, Kerr Dental, USA) versus a total-etch (Te-Econom Plus) resin composite, using an etching agent (Eco-Etch gel) and bonding agent (Single Bond Universal). Methods: Sixteen freshly extracted sound human posterior teeth were used. The teeth were randomly divided into two groups: 8 specimens per type of composite. Standard-shaped class V cavities were prepared on the buccal surface. One group was restored by Te-Econom Plus resin composite by total-etch technique using Eco-Etch gel, which was applied to dentine for 15 seconds, followed by rinsing, drying and bonding agent application (Single Bond Universal). The other group restored directly with self-adhering resin composite (Vertise-Flow) without application of etch or bond. Curing was done for 20 seconds using a light emitting diode light curing unit. Evaluation of the resin-dentin interface was done microscopically by examination of marginal gap distance in µm using scanning electron microscope (SEM), and chemical analysis of silver particles was observed using SEM with energy-dispersive X-ray spectrometry after 24 hours of specimen storage in ammoniacal silver nitrate. Results: Regarding marginal gap distance (µm) and silver atomic % mean values, teeth restored with self-adhering resin composite (Vertise-Flow) showed significantly higher mean values than the multi-step etch and rinse resin composite group (5.2 vs 0; 12.2 vs 8.2, respectively). Conclusions: Resin-dentin bonding using total-etch resin composite technique was more effective than self-adhering flowable resin composite (Vertise-Flow) regarding marginal gap formation and penetration of silver particles. Further studies for bond strength could be performed.

20.
Biomed Mater ; 10(6): 065006, 2015 Nov 06.
Article in English | MEDLINE | ID: mdl-26541174

ABSTRACT

Nonsurgical local treatment of a periapical lesion arising from trauma or bacterial infection is a promising innovative approach. The present study investigated the feasibility of developing injectable amorphous calcium phosphate nanoparticles (ACP NPs) and ACP NPs loaded with an anti-inflammatory drug; ibuprofen (IBU-ACP NPs) in the form of thermoreversible in situ gels to treat periapical lesions with the stimulation of bone formation. NPs were produced by a spray-drying technique. Different formulations of Poloxamer 407 were incorporated with/without the produced NPs to form injectable gels. A drug release study was carried out. A 3 month in vivo test on a dog model also was assessed. Results showed successful incorporation of the drug into the NPs of CP during spray drying. The particles had mean diameters varying from 100 to 200 nm with a narrow distribution. A drug release study demonstrated controlled IBU release from IBU-ACP NPs at a pH of 7.4 over 24 h. The gelation temperature of the injectable in situ gels based on Poloxamer 407 was measured to be 30 °C. After 3 months of implantation in dogs, the results clearly demonstrated that the inclusion of ACP NPs loaded with IBU showed high degrees of periapical bone healing and cementum layer deposition around the apical root tip.


Subject(s)
Calcium Phosphates/administration & dosage , Calcium Phosphates/chemical synthesis , Delayed-Action Preparations/administration & dosage , Ibuprofen/administration & dosage , Nanocapsules/administration & dosage , Periapical Diseases/drug therapy , Animals , Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Bone Substitutes/administration & dosage , Bone Substitutes/chemistry , Delayed-Action Preparations/chemistry , Diffusion , Dogs , Hydrogels/administration & dosage , Hydrogels/chemical synthesis , Ibuprofen/chemistry , Injections, Intralesional , Materials Testing , Molecular Conformation , Nanocapsules/chemistry , Nanocapsules/ultrastructure , Particle Size , Periapical Diseases/pathology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL