Endocrine ; 62(3): 546-551, 2018 12.
Article in English | MEDLINE | ID: mdl-30203122

ABSTRACT

PURPOSE: To determine whether ectopic thyroid had the same computed tomography (CT) value as orthotopic thyroid. METHODS: Twenty-one patients with 23 ectopic thyroids and 23 controls with orthotopic thyroids underwent CT scans and were included in this retrospective study. The CT images were reviewed in a blinded fashion by two radiologists. Independent-Samples T-test was used for comparison of CT attenuation values between two groups. RESULTS: Ectopic thyroids had significantly lower non-enhanced attenuation (91.04 ± 5.97 Hounsfield Units vs. 106.56 ± 4.06 Hounsfield Units, P = 0.038) and contrast-enhanced attenuation (141.32 ± 6.42 Hounsfield Units vs. 169.82 ± 4.30 Hounsfield Units, P = 0.001) values than orthotopic thyroids. CONCLUSIONS: Ectopic thyroids have lower CT attenuation values than orthotopic thyroids probably due to the structural or functional abnormalities. The dysgenesis and pathological changes of the ectopic thyroids may contribute to functional deficiency which finally leads to decrease of the CT attenuation values.


Subject(s)
Thyroid Dysgenesis/diagnostic imaging , Thyroid Gland/diagnostic imaging , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
2.
Shanghai Kou Qiang Yi Xue ; 15(1): 11-4, 2006 Feb.
Article in Chinese | MEDLINE | ID: mdl-16525600

ABSTRACT

PURPOSE: To investigate the diagnostic value of 16 slices spiral CT in maxillary sinus diseases. METHODS: 16 slices spiral CT findings of 58 cases with maxillary sinus diseases confirmed clinically were analyzed, postprocessing of images was performed by using the software package at the workstation. All the cases were proved by surgery. RESULTS: Among 58 cases, there were 30 cases with inflammatory diseases; 6 cases with benign tumors; 8 cases with malignant tumors and 14 cases with fractures. The correct rate of CT diagnosis for location was 100%, and for the nature of the disease was 91.38%. CONCLUSIONS: 16 slices spiral CT was proved to be a good way to show the range of maxillary sinus diseases, the degree of bony change and the relation to surrounding tissues, but determination of the nature of the diseases should be incorporated with clinical and pathological findings.


Subject(s)
Maxillary Sinus/diagnostic imaging , Tomography, Spiral Computed/methods , Humans , Reproducibility of Results
3.
Shanghai Kou Qiang Yi Xue ; 13(3): 164-7, 2004 Jun.
Article in Chinese | MEDLINE | ID: mdl-15269848

ABSTRACT

PURPOSE: To investigate CT findings of orbital fractures in maxillofacial injuries in order to improve clinical diagnostic accuracy. METHODS: CT findings of 138 cases (145 orbits) with orbital fractures in maxillofacial injuries were analyzed. RESULTS: In maxillofacial injuries, orbital fractures of medial and posterolateral walls were most common,which often showed multiple walls fractures. In 145 orbital fractures, there were single wall fractures in 51 cases (35.17%), two-wall fractures in 48 cases (33.10%), three-wall fractures in 31 cases (21.38%) and four-wall fractures in 15 cases (10.35%). CONCLUSIONS: There were complex orbital fracture in maxillofacial injures, CT examination is a very important tool for diagnosis,which should be applied routinely.


Subject(s)
Orbital Fractures/diagnostic imaging , Tomography, X-Ray Computed , Adolescent , Adult , Child , Child, Preschool , Female , Humans , Male , Maxillofacial Injuries/diagnostic imaging , Middle Aged