Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Acta Anaesthesiol Scand ; 66(8): 923-933, 2022 09.
Article in English | MEDLINE | ID: mdl-35675085

ABSTRACT

BACKGROUND: Controversy exists regarding the effects of a high versus a low intraoperative fraction of inspired oxygen (FiO2 ) in adults undergoing general anesthesia. This systematic review and meta-analysis investigated the effect of a high versus a low FiO2 on postoperative outcomes. METHODS: PubMed and Embase were searched on March 22, 2022 for randomized clinical trials investigating the effect of different FiO2 levels in adults undergoing general anesthesia for non-cardiac surgery. Two investigators independently reviewed studies for relevance, extracted data, and assessed risk of bias. Meta-analyses were performed for relevant outcomes, and potential effect measure modification was assessed in subgroup analyses and meta-regression. The evidence certainty was evaluated using GRADE. RESULTS: This review included 25 original trials investigating the effect of a high (mostly 80%) versus a low (mostly 30%) FiO2 . Risk of bias was intermediate for all trials. A high FiO2 did not result in a significant reduction in surgical site infections (OR: 0.91, 95% CI 0.81-1.02 [p = .10]). No effect was found for all other included outcomes, including mortality (OR = 1.27, 95% CI: 0.90-1.79 [p = .18]) and hospital length of stay (mean difference = 0.03 days, 95% CI -0.25 to 0.30 [p = .84). Results from subgroup analyses and meta-regression did not identify any clear effect modifiers across outcomes. The certainty of evidence (GRADE) was rated as low for most outcomes. CONCLUSIONS: In adults undergoing general anesthesia for non-cardiac surgery, a high FiO2 did not improve outcomes including surgical site infections, length of stay, or mortality. However, the certainty of the evidence was assessed as low.


Subject(s)
Oxygen , Surgical Wound Infection , Adult , Anesthesia, General , Humans
2.
Anesth Analg ; 135(5): 971-985, 2022 11 01.
Article in English | MEDLINE | ID: mdl-35703253

ABSTRACT

BACKGROUND: The optimal ventilation strategy during general anesthesia is unclear. This systematic review investigated the relationship between ventilation targets or strategies (eg, positive end-expiratory pressure [PEEP], tidal volume, and recruitment maneuvers) and postoperative outcomes. METHODS: PubMed and Embase were searched on March 8, 2021, for randomized trials investigating the effect of different respiratory targets or strategies on adults undergoing noncardiac surgery. Two investigators reviewed trials for relevance, extracted data, and assessed risk of bias. Meta-analyses were performed for relevant outcomes, and several subgroup analyses were conducted. The certainty of evidence was evaluated using Grading of Recommendations Assessment, Development and Evaluation (GRADE). RESULTS: This review included 63 trials with 65 comparisons. Risk of bias was intermediate for all trials. In the meta-analyses, lung-protective ventilation (ie, low tidal volume with PEEP) reduced the risk of combined pulmonary complications (odds ratio [OR], 0.37; 95% confidence interval [CI], 0.28-0.49; 9 trials; 1106 patients), atelectasis (OR, 0.39; 95% CI, 0.25-0.60; 8 trials; 895 patients), and need for postoperative mechanical ventilation (OR, 0.36; 95% CI, 0.13-1.00; 5 trials; 636 patients). Recruitment maneuvers reduced the risk of atelectasis (OR, 0.44; 95% CI, 0.21-0.92; 5 trials; 328 patients). We found no clear effect of tidal volume, higher versus lower PEEP, or recruitment maneuvers on postoperative pulmonary complications when evaluated individually. For all comparisons across targets, no effect was found on mortality or hospital length of stay. No effect measure modifiers were found in subgroup analyses. The certainty of evidence was rated as very low, low, or moderate depending on the intervention and outcome. CONCLUSIONS: Although lung-protective ventilation results in a decrease in pulmonary complications, randomized clinical trials provide only limited evidence to guide specific ventilation strategies during general anesthesia for adults undergoing noncardiac surgery.


Subject(s)
Positive-Pressure Respiration , Pulmonary Atelectasis , Adult , Humans , Tidal Volume , Positive-Pressure Respiration/adverse effects , Positive-Pressure Respiration/methods , Pulmonary Atelectasis/etiology , Anesthesia, General/adverse effects , Lung , Postoperative Complications/etiology , Postoperative Complications/prevention & control
3.
Br J Anaesth ; 128(3): 416-433, 2022 03.
Article in English | MEDLINE | ID: mdl-34916049

ABSTRACT

BACKGROUND: During general anaesthesia for noncardiac surgery, there remain knowledge gaps regarding the effect of goal-directed haemodynamic therapy on patient-centred outcomes. METHODS: Included clinical trials investigated goal-directed haemodynamic therapy during general anaesthesia in adults undergoing noncardiac surgery and reported at least one patient-centred postoperative outcome. PubMed and Embase were searched for relevant articles on March 8, 2021. Two investigators performed abstract screening, full-text review, data extraction, and bias assessment. The primary outcomes were mortality and hospital length of stay, whereas 15 postoperative complications were included based on availability. From a main pool of comparable trials, meta-analyses were performed on trials with homogenous outcome definitions. Certainty of evidence was evaluated using Grading of Recommendations, Assessment, Development, and Evaluations (GRADE). RESULTS: The main pool consisted of 76 trials with intermediate risk of bias for most outcomes. Overall, goal-directed haemodynamic therapy might reduce mortality (odds ratio=0.84; 95% confidence interval [CI], 0.64 to 1.09) and shorten length of stay (mean difference=-0.72 days; 95% CI, -1.10 to -0.35) but with low certainty in the evidence. For both outcomes, larger effects favouring goal-directed haemodynamic therapy were seen in abdominal surgery, very high-risk surgery, and using targets based on preload variation by the respiratory cycle. However, formal tests for subgroup differences were not statistically significant. Goal-directed haemodynamic therapy decreased risk of several postoperative outcomes, but only infectious outcomes and anastomotic leakage reached moderate certainty of evidence. CONCLUSIONS: Goal-directed haemodynamic therapy during general anaesthesia might decrease mortality, hospital length of stay, and several postoperative complications. Only infectious postoperative complications and anastomotic leakage reached moderate certainty in the evidence.


Subject(s)
Anesthesia, General/mortality , Hemodynamics/physiology , General Surgery/methods , Humans , Postoperative Complications/mortality , Postoperative Complications/prevention & control
4.
Nat Commun ; 11(1): 634, 2020 Jan 31.
Article in English | MEDLINE | ID: mdl-32005815

ABSTRACT

The non-equilibrium dynamics of electrons and nuclei govern the function of photoactive materials. Disentangling these dynamics remains a critical goal for understanding photoactive materials. Here we investigate the photoinduced dynamics of the [Fe(bmip)2]2+ photosensitizer, where bmip = 2,6-bis(3-methyl-imidazole-1-ylidine)-pyridine, with simultaneous femtosecond-resolution Fe Kα and Kß X-ray emission spectroscopy (XES) and X-ray solution scattering (XSS). This measurement shows temporal oscillations in the XES and XSS difference signals with the same 278 fs period oscillation. These oscillations originate from an Fe-ligand stretching vibrational wavepacket on a triplet metal-centered (3MC) excited state surface. This 3MC state is populated with a 110 fs time constant by 40% of the excited molecules while the rest relax to a 3MLCT excited state. The sensitivity of the Kα XES to molecular structure results from a 0.7% average Fe-ligand bond length shift between the 1 s and 2p core-ionized states surfaces.

5.
Angew Chem Int Ed Engl ; 59(1): 364-372, 2020 Jan 02.
Article in English | MEDLINE | ID: mdl-31602726

ABSTRACT

Iron N-heterocyclic carbene (NHC) complexes have received a great deal of attention recently because of their growing potential as light sensitizers or photocatalysts. We present a sub-ps X-ray spectroscopy study of an FeII NHC complex that identifies and quantifies the states involved in the deactivation cascade after light absorption. Excited molecules relax back to the ground state along two pathways: After population of a hot 3 MLCT state, from the initially excited 1 MLCT state, 30 % of the molecules undergo ultrafast (150 fs) relaxation to the 3 MC state, in competition with vibrational relaxation and cooling to the relaxed 3 MLCT state. The relaxed 3 MLCT state then decays much more slowly (7.6 ps) to the 3 MC state. The 3 MC state is rapidly (2.2 ps) deactivated to the ground state. The 5 MC state is not involved in the deactivation pathway. The ultrafast partial deactivation of the 3 MLCT state constitutes a loss channel from the point of view of photochemical efficiency and highlights the necessity to screen transition-metal complexes for similar ultrafast decays to optimize photochemical performance.

6.
Chem Sci ; 10(22): 5749-5760, 2019 Jun 14.
Article in English | MEDLINE | ID: mdl-31293761

ABSTRACT

Light-driven molecular reactions are dictated by the excited state potential energy landscape, depending critically on the location of conical intersections and intersystem crossing points between potential surfaces where non-adiabatic effects govern transition probabilities between distinct electronic states. While ultrafast studies have provided significant insight into electronic excited state reaction dynamics, experimental approaches for identifying and characterizing intersections and seams between electronic states remain highly system dependent. Here we show that for 3d transition metal systems simultaneously recorded X-ray diffuse scattering and X-ray emission spectroscopy at sub-70 femtosecond time-resolution provide a solid experimental foundation for determining the mechanistic details of excited state reactions. In modeling the mechanistic information retrieved from such experiments, it becomes possible to identify the dominant trajectory followed during the excited state cascade and to determine the relevant loci of intersections between states. We illustrate our approach by explicitly mapping parts of the potential energy landscape dictating the light driven low-to-high spin-state transition (spin crossover) of [Fe(2,2'-bipyridine)3]2+, where the strongly coupled nuclear and electronic dynamics have been a source of interest and controversy. We anticipate that simultaneous X-ray diffuse scattering and X-ray emission spectroscopy will provide a valuable approach for mapping the reactive trajectories of light-triggered molecular systems involving 3d transition metals.

7.
J Synchrotron Radiat ; 25(Pt 2): 306-315, 2018 Mar 01.
Article in English | MEDLINE | ID: mdl-29488907

ABSTRACT

Time-resolved X-ray scattering patterns from photoexcited molecules in solution are in many cases anisotropic at the ultrafast time scales accessible at X-ray free-electron lasers (XFELs). This anisotropy arises from the interaction of a linearly polarized UV-Vis pump laser pulse with the sample, which induces anisotropic structural changes that can be captured by femtosecond X-ray pulses. In this work, a method for quantitative analysis of the anisotropic scattering signal arising from an ensemble of molecules is described, and it is demonstrated how its use can enhance the structural sensitivity of the time-resolved X-ray scattering experiment. This method is applied on time-resolved X-ray scattering patterns measured upon photoexcitation of a solvated di-platinum complex at an XFEL, and the key parameters involved are explored. It is shown that a combined analysis of the anisotropic and isotropic difference scattering signals in this experiment allows a more precise determination of the main photoinduced structural change in the solute, i.e. the change in Pt-Pt bond length, and yields more information on the excitation channels than the analysis of the isotropic scattering only. Finally, it is discussed how the anisotropic transient response of the solvent can enable the determination of key experimental parameters such as the instrument response function.

8.
Resuscitation ; 125: 16-21, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29407206

ABSTRACT

AIM OF THE REVIEW: Animal models are essential in advancing resuscitation research but are susceptible to various biases compromising internal validity, which may explain unsuccessful transition to human clinical trials. This study aimed to assess risk of bias in animal studies of cardiac arrest. DATA SOURCES: This study was based on a previous systematic review of all animal cardiac arrest studies published between March 8, 2011 and March 8, 2016 in PubMed and EMBASE. For this study, we focused on interventional studies and selected a random sample of 50 pig and 50 rat studies. We used a modified version of the SYRCLE's risk of bias tool for animal studies. Bias assessment was performed by two independent reviewers. RESULTS: 92% of pig studies and 88% of rat studies used randomization to assign interventions, but the methodology was unknown or insufficiently reported in 60% and 68% of the studies, respectively. Correct timing of randomization was lacking or unclear in over half of the studies. 40% of pig studies and 28% of rat studies reported insufficient baseline characteristics. When possible, blinding was not performed/reported in 68% of rat studies and 31% of pig studies. Blinding of outcome assessors was missing or inadequately reported in 65% of pig studies and 60% of rat studies. 80% of all studies lacked a sample size calculation, while 60% of pig and 80% of rat studies omitted a specified primary outcome. CONCLUSION: This study indicates insufficient reporting and methodological shortcomings in animal models of cardiac arrest.


Subject(s)
Disease Models, Animal , Heart Arrest , Random Allocation , Research Design/standards , Animals , Humans , Publication Bias , Rats , Reproducibility of Results , Swine
9.
Phys Chem Chem Phys ; 20(6): 4238-4249, 2018 Feb 07.
Article in English | MEDLINE | ID: mdl-29364300

ABSTRACT

The excited state dynamics of solvated [Fe(bpy)(CN)4]2-, where bpy = 2,2'-bipyridine, show significant sensitivity to the solvent Lewis acidity. Using a combination of optical absorption and X-ray emission transient spectroscopies, we have previously shown that the metal to ligand charge transfer (MLCT) excited state of [Fe(bpy)(CN)4]2- has a 19 picosecond lifetime and no discernable contribution from metal centered (MC) states in weak Lewis acid solvents, such as dimethyl sulfoxide and acetonitrile.1,2 In the present work, we use the same combination of spectroscopic techniques to measure the MLCT excited state relaxation dynamics of [Fe(bpy)(CN)4]2- in water, a strong Lewis acid solvent. The charge-transfer excited state is now found to decay in less than 100 femtoseconds, forming a quasi-stable metal centered excited state with a 13 picosecond lifetime. We find that this MC excited state has triplet (3MC) character, unlike other reported six-coordinate Fe(ii)-centered coordination compounds, which form MC quintet (5MC) states. The solvent dependent changes in excited state non-radiative relaxation for [Fe(bpy)(CN)4]2- allows us to infer the influence of the solvent on the electronic structure of the complex. Furthermore, the robust characterization of the dynamics and optical spectral signatures of the isolated 3MC intermediate provides a strong foundation for identifying 3MC intermediates in the electronic excited state relaxation mechanisms of similar Fe-centered systems being developed for solar applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...