Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Am J Cardiol ; 220: 84-91, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38604492

ABSTRACT

Development of functional tricuspid regurgitation (TR) because of chronic mitral disease and subsequent heart failure is common. However, the effect of TR on clinical outcomes after transcatheter mitral valve replacement (TMVR) remains unclear. We aimed to evaluate the impact of baseline TR on outcomes after TMVR. This was a single-center, retrospective analysis of patients who received valve-in-valve or valve-in-ring TMVR between 2012 and 2022. Patients were categorized into none/mild TR and moderate/severe TR based on baseline echocardiography. The primary outcome was 3 years all-cause death and the secondary outcomes were in-hospital events. Of the 135 patients who underwent TMVR, 64 (47%) exhibited none/mild TR at baseline, whereas 71 (53%) demonstrated moderate/severe TR. There were no significant differences in in-hospital events between the groups. At 3 years, the moderate/severe TR group exhibited a significantly increased risk of all-cause death (adjusted hazard ratio 3.37, 95% confidence interval 1.35 to 8.41, p = 0.009). When patients with baseline moderate/severe TR were stratified by echocardiography at 30 days into improved (36%) and nonimproved (64%) TR groups, although limited by small sample size, there was no significant difference in 3-year all-cause mortality (p = 0.48). In conclusion, this study investigating the impact of baseline TR on clinical outcomes revealed that moderate/severe TR is prevalent in those who underwent TMVR and is an independent predictor of 3-year all-cause mortality. Earlier mitral valve intervention before the development of significant TR may play a pivotal role in improving outcomes after TMVR.


Subject(s)
Echocardiography , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Tricuspid Valve Insufficiency , Humans , Male , Tricuspid Valve Insufficiency/surgery , Female , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Cardiac Catheterization/methods , Severity of Illness Index , Treatment Outcome , Cause of Death/trends , Postoperative Complications/epidemiology , Aged, 80 and over , Mitral Valve/surgery , Mitral Valve/diagnostic imaging
2.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38471643

ABSTRACT

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Subject(s)
Cardiomyopathy, Hypertrophic , Heart Valve Prosthesis Implantation , Myotomy , Ventricular Outflow Obstruction, Left , Ventricular Outflow Obstruction , Humans , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Cardiac Catheterization/methods , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery , Treatment Outcome , Cardiomyopathy, Hypertrophic/complications , Myotomy/adverse effects
3.
JACC Cardiovasc Interv ; 17(5): 635-644, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38244000

ABSTRACT

BACKGROUND: Transcatheter closure of transcatheter heart valve (THV)-related paravalvular leak (PVL) is associated with a high failure rate with available devices due to the complex interaction of THV and aortic/mitral annulus. OBJECTIVES: This study reports on novel transcatheter techniques to treat PVL after THV. METHODS: The authors describe consecutive patients who underwent PVL closure after transcatheter aortic valve replacement (TAVR) or transcatheter mitral valve replacement (TMVR). A covered self-expanding stent (Viabahn) was deployed in the defect to create a seal between the THV and annulus. A vascular plug (Amplatzer Vascular Plug 2 [AVP2] or AVP4) was then deployed inside the covered stent to obliterate PVL. RESULTS: Eight patients with THV-related PVL were treated using this method (aortic [3 SAPIEN, 1 Evolut], mitral [2 SAPIEN-in-MAC (mitral annular calcification), 2 M3 TMVR). Various combinations of stents and plugs were used (5 mm × 2.5 cm Viabahn + 6 mm AVP4 [n = 2], 8 mm × 2.5 cm Viabahn + 10 mm AVP2 [n = 5], and 10 mm × 5.0 cm Viabahn + 12 mm AVP2 [n = 1]). All had technical success with immediate elimination of target PVL, without in-hospital complications. None had signs of postprocedure hemolysis. All patients were discharged alive (median 3.5 days [Q1-Q3: 1.0-4.8 days]). No residual PVL was seen at discharge, except for 1 patient with mild regurgitation due to another untreated PVL location. One patient died before 30 days due to complication of valve-in-MAC TMVR. In remaining patients, none had recurrence of PVL at 30 days. Symptoms decreased to NYHA functional class I/II in 6 patients. NYHA functional class III symptoms remained in 1 patient with mitral regurgitation awaiting subsequent valve replacement procedure. CONCLUSIONS: The technique of sequential deployment of a covered stent and vascular plug may effectively treat THV-related PVL.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Heart Valve Prosthesis/adverse effects , Prosthesis Failure , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Stents , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery
5.
Circ Cardiovasc Interv ; 16(10): e013243, 2023 10.
Article in English | MEDLINE | ID: mdl-37732604

ABSTRACT

BACKGROUND: Postinfarction ventricular septal defect (VSD) is a catastrophic complication of myocardial infarction. Surgical repair still has poor outcomes. This report describes clinical outcomes after a novel hybrid transcatheter/surgical repair in patients with apical VSD. METHODS: Seven patients with postmyocardial infarction apical VSD underwent hybrid transcatheter repair via subxiphoid surgical access. A transcatheter occluder (Amplatzer Septal Occluder) with a trailing premounted suture was deployed through the right ventricular wall and through the ventricular septum into the left ventricular apex. The trailing suture was used to connect an anchor external to the right ventricular wall. Tension on the suture then collapses the right ventricular free wall against the septum and left ventricular occluder, thereby obliterating the VSD. Outcomes were compared with 9 patients who underwent surgical repair using either patch or primary suture closure. RESULTS: All patients had significant left-to-right shunt (Qp:Qs 2.5:1; interquartile range [IQR, 2.1-2.6] hybrid repair versus 2.0:1 [IQR, 2.0-2.5] surgical repair), and elevated right ventricular systolic pressure (62 [IQR, 46-71] versus 49 [IQR, 43-54] mm Hg, respectively). All had severely depressed stroke volume index (22 versus 21 mL/m2) with ≈45% in each group requiring mechanical support preprocedurally. The procedure was done 15 (IQR, 10-50) versus 24 (IQR, 10-134) days postmyocardial infarction, respectively. Both groups of patients underwent repair with technical success and without intraprocedural death. One patient in the hybrid group and 4 in the surgical group developed multiorgan failure. The hybrid group had a higher survival at discharge (86% versus 56%) and at 30 days (71% versus 56%), but similar at 1 year (57% versus 56%). During follow-up, 1 patient in each group required reintervention for residual VSD (hybrid: 9 months versus surgical: 5 days). CONCLUSIONS: Early intervention with a hybrid transcatheter/surgical repair may be a viable alternative to traditional surgery for postinfarction apical VSD.


Subject(s)
Anterior Wall Myocardial Infarction , Heart Septal Defects, Ventricular , Myocardial Infarction , Septal Occluder Device , Humans , Treatment Outcome , Cardiac Catheterization , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/etiology , Heart Septal Defects, Ventricular/surgery , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/therapy
10.
Cardiovasc Revasc Med ; 21(5): 594-601, 2020 05.
Article in English | MEDLINE | ID: mdl-31523003

ABSTRACT

BACKGROUND/PURPOSE: General Anesthesia (GA) and conscious sedation (CS) are anesthetics for transfemoral transcatheter aortic valve replacement (TF-TAVR). We compared TF-TAVR outcomes using a novel anesthetic approach with fascia iliaca block (FIB) plus minimal CS (MCS) versus GA. METHODS: This retrospective propensity-matched study included consecutive TF-TAVR patients from January 2013 to December 2017 and dichotomized into FIB-MCS vs. GA. Data were collected from electronic records, Society of Thoracic Surgery (STS) database, and the Transcatheter Valve Therapies (TVT) Registry. Primary endpoints were operating room (OR) time, intensive care unit (ICU) and hospital length of stay (LOS). Secondary endpoints were 30-day, 1-year mortality, quality of life, 30-day re-hospitalization rate, failure of FIB-MCS, and hospital safety outcomes. RESULTS: A total of 304 TF-TAVR patients; FIB-MCS (n = 219) vs. GA (n = 85). Propensity matched 162 patients; FIB-MCS (n = 108) vs. GA (n = 54). FIB-MCS had shorter OR time (197.6 ±â€¯56.3 vs. 248.2 ±â€¯46.3 min, p < 0.001), ICU (67.8 ±â€¯71.7 vs. 84.9 ±â€¯72.1 h, p = 0.004) and hospital LOS (3.2 ±â€¯3.7 vs. 5.9 ±â€¯3.5 d, p < 0.001). FIB-MCS had lower rate of blood transfusion. FIB-MCA vs. GA 30-day and 1-year mortality were similar in the entire (2.3 vs. 2.4%, p = 1.0; and 8.2 vs. 5.9%, p = 0.49) and matched cohorts (0 vs. 3.7%, p = 0.11 and 7.4 vs. 5.6%, p = 0.75). FIB-MCS were less likely to be re-hospitalized [Odd Ratio: 0.32, CI:0.13-0.76] and 2% to 3% higher KCCQ-12 score. CONCLUSION: TF-TAVR using FIB-MCS is feasible and safe with shorter OR time, ICU and hospital LOS, lower risk of 30-day re-hospitalization, similar 30-day and 1-year mortality with better quality of life at 1-year follow-up.


Subject(s)
Anesthesia, General , Aortic Valve Stenosis/surgery , Catheterization, Peripheral , Conscious Sedation , Femoral Artery , Nerve Block , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Anesthesia, General/adverse effects , Anesthesia, General/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/mortality , Conscious Sedation/adverse effects , Conscious Sedation/mortality , Databases, Factual , Electronic Health Records , Female , Humans , Length of Stay , Male , Nerve Block/adverse effects , Nerve Block/mortality , Operative Time , Patient Readmission , Punctures , Quality of Life , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
11.
J Invasive Cardiol ; 31(6): E98-E132, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31158808

ABSTRACT

The International Andreas Gruentzig Society is an educational society of physicians and scientists interested in cardiovascular and related fields. Members cooperate in the advancement of knowledge and education through research, publication, study, and teaching in the fields of cardiovascular disease. This summary reflects the proceedings from the recent scientific meeting to assess current clinical problems and propose future directions and possible solutions.


Subject(s)
Cardiology/methods , Cardiovascular Diseases/therapy , Congresses as Topic , Societies, Medical , Humans
12.
Catheter Cardiovasc Interv ; 93(7): 1228-1235, 2019 06 01.
Article in English | MEDLINE | ID: mdl-30393942

ABSTRACT

OBJECTIVE: To evaluate contrast media (CM) volume (CMV) saved using the DyeVert™ Plus Contrast Reduction System (DyeVert Plus System, Osprey Medical) in patients undergoing diagnostic coronary angiogram (CAG) and/or percutaneous coronary interventional (PCI) procedures performed with manual injections. BACKGROUND: Current guidelines advocate for monitoring and minimization of the total volume of CM in chronic kidney disease (CKD) patients undergoing invasive cardiac procedures. The DyeVert Plus System is an FDA cleared device designed to reduce CMV delivered during angiography and permit real-time CMV monitoring. METHODS: We performed a multicenter, single-arm, observational study. Eligible subjects were ≥ 18 years old with baseline estimated glomerular filtration rate (eGFR) 20-60 mL/min/1.73 m2 . The primary endpoint was % CMV saved over the total procedure. A secondary objective was to evaluate adverse events (AEs) related to DyeVert Plus System or to CM use. RESULTS: A total of 114 subjects were enrolled at eight centers. Mean age was 72 ± 9 years, 72% were male, and mean body mass index was 29 ± 5. Baseline eGFR was 43 ± 11 mL/min/1.73 m2 . CAG-only was performed in 65% of cases. One hundred and five subjects were evaluable for the primary endpoint. Mean CMV attempted was 112 ± 85 mL (range 22-681) and mean CMV delivered was 67 ± 51 mL (range 12-403), resulting in an overall CMV savings of 40.1 ± 8.8% (95% CI 38.4, 41.8; P < 0.0001) per procedure. Image quality was maintained in all but one case where the system was turned off for one injection. No DyeVert Plus System-related AEs were reported. Acute kidney injury (AKI; defined as serum creatinine rise of >0.3 mg/dL from baseline) was reported in 11 cases with seven occurring in subjects with baseline eGFR < 30 and three AKI events were attributed to CM. AKI rates increased as CMV/eGFR ratios increased. CONCLUSIONS: These data suggest DyeVert Plus System use in CKD patients undergoing CAG and/or PCI results in clinically meaningful CMV savings while maintaining image quality.


Subject(s)
Acute Kidney Injury/prevention & control , Contrast Media/administration & dosage , Coronary Angiography/instrumentation , Coronary Artery Disease/diagnostic imaging , Glomerular Filtration Rate , Kidney/drug effects , Acute Kidney Injury/chemically induced , Acute Kidney Injury/diagnostic imaging , Acute Kidney Injury/physiopathology , Aged , Aged, 80 and over , Contrast Media/adverse effects , Coronary Angiography/adverse effects , Coronary Artery Disease/complications , Coronary Artery Disease/therapy , Equipment Design , Female , Humans , Kidney/physiopathology , Male , Middle Aged , Percutaneous Coronary Intervention , Predictive Value of Tests , Prospective Studies , Protective Factors , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/physiopathology , Risk Factors , Treatment Outcome , United States
13.
Case Rep Cardiol ; 2018: 6872748, 2018.
Article in English | MEDLINE | ID: mdl-29725546

ABSTRACT

Bioprosthetic aortic valve degeneration may present as acute, severe aortic regurgitation and cardiogenic shock. Such patients may be unsuitable for emergency valve replacement surgery due to excessive risk of operative mortality but could be treatable with transfemoral valve-in-valve transcatheter aortic valve implantation (TAVI). There is a paucity of data regarding the feasibility of valve-in-valve TAVI in patients presenting with cardiogenic shock due to acute aortic insufficiency from stentless bioprosthetic valve degeneration. We present one such case, highlighting the unique aspects of valve-in-valve TAVI for this challenging patient subset.

16.
Interv Cardiol Clin ; 6(3): 465-480, 2017 07.
Article in English | MEDLINE | ID: mdl-28600098

ABSTRACT

Technological advances have promoted challenges to prioritizing and combining therapies for heart failure. The concept of prioritization implies distinct but inextricably linked considerations. They may be viewed from pathophysiologic, clinical, and procedural perspectives, encompassing analysis of hemodynamic status, anatomic considerations, and technical challenges. It is essential to consider factors, including conduction disease, renal and pulmonary function, hematological derangements, and so forth. These considerations allow determination of clinical goals, which determine prioritization and interventional strategies. These considerations then facilitate goal setting for medical and interventional therapies as definitive/destination, preservation/salvage, stepwise, bridge, or palliation.


Subject(s)
Decision Making , Heart Failure/surgery , Heart-Assist Devices , Hemodynamics/physiology , Palliative Care/methods , Heart Failure/physiopathology , Humans
18.
Am J Cardiol ; 119(3): 457-460, 2017 Feb 01.
Article in English | MEDLINE | ID: mdl-27931723

ABSTRACT

Frailty is a powerful predictor of outcomes after transcatheter aortic valve implantation (TAVI). Sarcopenia as assessed by psoas muscle area (PMA) is a validated tool to assess frailty before surgical procedures. We evaluated PMA as a predictor of outcomes after TAVI in 152 consecutive patients who underwent this procedure at our institution from 2011 to 2014. Preoperative computed tomography scans were used to measure PMA, which then was indexed to body surface area. Outcomes evaluated included (1) early poor outcome (30 days mortality, stroke, dialysis, and prolonged ventilation), (2) 1-year mortality, and (3) high-resource utilization (length of stay >7 days, discharge to rehabilitation, or readmission within 30 days). Indexed PMA (odds ratio [OR] 3.19, confidence interval [CI] 1.30 to 7.83; p = 0.012) and age (OR 1.92, CI 1.87 to 1.98; p = 0.012) predicted early poor outcome. Society of Thoracic Surgeons score predicted 1-year mortality (hazard ratio 3.07, CI 1.93 to 6.23; p = 0.011). High-resource utilization was observed more frequently in patients with PMA less than the median (73% vs 51%, OR 2.65, CI 1.32 to 5.36; p = 0.006). In conclusion, indexed PMA predicts early poor outcome and high-resource utilization after TAVI.


Subject(s)
Aortic Valve Stenosis/surgery , Mortality , Psoas Muscles/diagnostic imaging , Renal Insufficiency/epidemiology , Respiration, Artificial/statistics & numerical data , Sarcopenia/diagnostic imaging , Stroke/epidemiology , Transcatheter Aortic Valve Replacement , Age Factors , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Cause of Death , Comorbidity , Female , Frail Elderly , Humans , Length of Stay/statistics & numerical data , Male , Odds Ratio , Organ Size , Patient Discharge , Patient Readmission/statistics & numerical data , Prognosis , Proportional Hazards Models , Psoas Muscles/pathology , Rehabilitation Centers , Renal Dialysis/statistics & numerical data , Renal Insufficiency/therapy , Sarcopenia/epidemiology , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...