Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
ACS Earth Space Chem ; 8(8): 1609-1622, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39166261

ABSTRACT

Variable wind speeds over the ocean can have a significant impact on the formation mechanism and physical-chemical properties of sea spray aerosols (SSA), which in turn influence their climate-relevant impacts. Herein, for the first time, we investigate the effects of wind speed on size-dependent morphology and composition of individual nascent SSA generated from wind-wave interactions of natural seawater within a wind-wave channel as a function of size and their particle-to-particle variability. Filter-based thermal optical analysis, atomic force microscopy (AFM), AFM infrared spectroscopy (AFM-IR), and scanning electron microscopy (SEM) were employed in this regard. This study focuses on SSA with sizes within 0.04-1.8 µm generated at two wind speeds: 10 m/s, representing a wind lull scenario over the ocean, and 19 m/s, indicative of the wind speeds encountered in stormy conditions. Filter-based measurements revealed a reduction of the organic mass fraction as the wind speed increases. AFM imaging at 20% relative humidity of individual SSA identified six main morphologies: prism-like, rounded, core-shell, rod, rod inclusion core-shell, and aggregates. At 10 m/s, most SSA were rounded, while at 19 m/s, core-shells became predominant. Based on AFM-IR, rounded SSA at both wind speeds had similar composition, mainly composed of aliphatic and oxygenated species, whereas the shells of core-shells displayed more oxygenated organics at 19 m/s and more aliphatic organics at 10 m/s. Collectively, our observations can be attributed to the disruption of the sea surface microlayer film structure at higher wind speeds. The findings reveal a significant impact of wind speed on morphology and composition of SSA, which should be accounted for accurate assessment of their climate effects.

2.
Environ Sci Technol ; 55(9): 5731-5741, 2021 05 04.
Article in English | MEDLINE | ID: mdl-33819033

ABSTRACT

Increases in the salt concentration of freshwater result in detrimental impacts on water quality and ecosystem biodiversity. Biodiversity effects include freshwater microbiota, as increasing salinity can induce shifts in the structure of native freshwater bacterial communities, which could disturb their role in mediating basal ecosystem services. Moreover, salinity affects the wave breaking and bubble-bursting mechanisms via which water-to-air dispersal of bacteria occurs. Given this dual effect of freshwater salinity on waterborne bacterial communities and their aerosolization mechanism, further effects on aerosolized bacterial diversity and abundance are anticipated. Cumulative salt additions in the freshwater-euhaline continuum (0-35 g/kg) were administered to a freshwater sample aerosolized inside a breaking wave analogue tank. Waterborne and corresponding airborne bacteria were sampled at each salinity treatment and later analyzed for diversity and abundance. Results demonstrated that the airborne bacterial community was significantly different (PERMANOVA; F1,22 = 155.1, r2 = 0.38, p < 0.001) from the waterborne community. The relative aerosolization factor (r-AF), defined as the air-to-water relative abundance ratio, revealed that different bacterial families exhibited either an enhanced (r-AF ≫ 1), neutral (r-AF ∼ 1), or diminished (r-AF ≪ 1) transfer to the aerosol phase throughout the salinization gradient. Going from freshwater to euhaline conditions, aerosolized bacterial abundance exhibited a nonmonotonic response with a maximum peak at lower oligohaline conditions (0.5-1 g/kg), a decline at higher oligohaline conditions (5 g/kg), and a moderate increase at polyhaline-euhaline conditions (15-35 g/kg). Our results demonstrate that increases in freshwater salinity are likely to influence the abundance and diversity of aerosolized bacteria. These shifts in aerosolized bacterial communities might have broader implications on public health by increasing exposure to airborne pathogens via inhalation. Impacts on regional climate, related to changes in biological ice-nucleating particles (INPs) emission from freshwater, are also expected.


Subject(s)
Microbiota , Salinity , Bacteria , Biodiversity , Fresh Water , Humans
3.
J Manuf Syst ; 60: 762-773, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33551537

ABSTRACT

The COVID-19 pandemic has disrupted the supply chain for personal protective equipment (PPE) for medical professionals, including N95-type respiratory protective masks. To address this shortage, many have looked to the agility and accessibility of additive manufacturing (AM) systems to provide a democratized, decentralized solution to producing respirators with equivalent protection for last-resort measures. However, there are concerns about the viability and safety in deploying this localized download, print, and wear strategy due to a lack of commensurate quality assurance processes. Many open-source respirator designs for AM indicate that they do not provide N95-equivalent protection (filtering 95% of SARS-CoV-2 particles) because they have either not passed aerosol generation tests or not been tested. Few studies have quantified particle transmission through respirator designs outside of the filter medium. This is concerning because several polymer-based AM processes produce porous parts, and inherent process variation between printers and materials also threaten the integrity of tolerances and seals within the printed respirator assembly. No study has isolated these failure mechanisms specifically for respirators. The goal of this paper is to measure particle transmission through printed respirators of different designs, materials, and AM processes. The authors compare the performance of printed respirators to N95 respirators and cloth masks. Respirators in this study printed using desktop- and industrial-scale fused filament fabrication processes and industrial-scale powder bed fusion processes were not sufficiently reliable for widespread distribution and local production of N95-type respiratory protection. Even while assuming a perfect seal between the respirator and the user's face, although a few respirators provided >90% efficiency at the 100-300 nm particle range, almost all printed respirators provided <60% filtration efficiency. Post-processing procedures including cleaning, sealing surfaces, and reinforcing the filter cap seal generally improved performance, but the printed respirators showed similar performance to various cloth masks. The authors further explore the process-driven aspects leading to low filtration efficiency. Although the design/printer/material combination dictates the AM respirator performance, the identified failure modes originate from system-level constraints and are therefore generalizable across multiple AM processes. Quantifying the limitations of AM in producing N95-type respiratory protective masks advances understanding of AM systems toward the development of better part and machine designs to meet the needs of reliable, functional, end-use parts.

4.
Am J Infect Control ; 49(1): 8-14, 2021 01.
Article in English | MEDLINE | ID: mdl-32599102

ABSTRACT

BACKGROUND: Response to the COVID-19 pandemic by hospital systems has been strained by severe shortages in personal protective equipment (PPE), particularly N95 respirators. Recently, the Centers for Disease Control and Prevention endorsed decontamination strategies to prolong the lifespan of single use respirators. Battelle and Duke University have validated hospital protocols to decontaminate respirators using vaporized hydrogen peroxide (VHP) at 30%-35% concentrations. To prolong our supply of respirators, we evaluated and implemented VHP decontamination at 59% hydrogen peroxide concentration while detailing the effects of this process on the filtration efficiency and quantitative fit of single-use respirators. This study may help other health systems develop local solutions to their N95 mask shortage during this COVID-19 pandemic. METHODS: N95 respirators (3M 8211 FF and 9210 FF) that were treated with 5 and 10 cycles of VHP by the V-PRO maX Low Temperature Sterilization System were evaluated quantitatively for filtration efficiency as well as with quantitative fit testing per Occupational Safety and Health Administration standards. A decontamination protocol was concurrently implemented at our institution. This process involved depositing used masks, reprocessing, and re-distributing treated masks efficiently back to frontline providers. Furthermore, we implemented patient safety officers on COVID-19/person under investigation units to ensure optimized donning/doffing of respirators through frontline provider education. RESULTS: There were no statistically significant changes in mean filtration efficiency between the control and VHP-treated respirators. Furthermore, both treated and untreated respirators demonstrated fit factors above the minimum pass requirement. CONCLUSIONS: We have successfully demonstrated that N95 respirator decontamination with VHP at 59% hydrogen peroxide can be safely utilized to decontaminate single-use N95 respirators without significant effects on filtration efficiency or quantitative fit testing. With the COVID-19 pandemic and N95 respirator shortage, health systems without access to commercial decontamination processes should investigate the viability of such a process in their facilities.


Subject(s)
Anti-Infective Agents, Local , Decontamination/methods , Equipment Reuse , Hydrogen Peroxide , Materials Testing , N95 Respirators , COVID-19/prevention & control , Humans , N95 Respirators/supply & distribution , Personal Protective Equipment/supply & distribution , SARS-CoV-2 , Sterilization , Volatilization
SELECTION OF CITATIONS
SEARCH DETAIL