Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Med Phys ; 39(6Part3): 3621, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28517373

ABSTRACT

PURPOSE: Nuclear medicine quality control programs require daily evaluation for the presence of potential non-uniformities by commonly utilizing a traditional pixel value-based assessment (Integral CFOVUniformity). While this method effectively captures regional non- uniformities in the image, it does not adequately reflect subtle periodic structures that are visually apparent and clinically unacceptable, therefore requiring the need for additional visual inspection of the image. The goal of this project was to develop a new uniformity assessment metric by targetingstructural patterns and more closely correlating with visual inspection. METHODS: The new quantitative uniformity assessment metric is based on the 2D Noise Power Spectrum (NPS). A full 2D NPS was performed on each image. The NPS was thresholded to remove quantum noise and further filtered by the visual response function. A score, the Structure Noise Index (SNI), was then applied to each based on the average magnitude of the structured noise in the processed image. To verify the validity of the new metric, 50 daily uniformity images with varying degrees of visual structured and non-structured non-uniformity were scored by 5 expert nuclear medicine physicists. The correlation between the visual score and SNI were assessed. The Integral CFOV was also compared against the visual score. RESULTS: Our new SNI assessment metric compared to the Integral CFOV showed in increase in sensitivity from 67% to 100% in correctly identifying structured non-uniformities. The overall positive predictive value also increased from 55% to 72%. CONCLUSIONS: Our new uniformity metric correlates much more closely with visual assessment of structured non- uniform NM images than the traditional pixel-based method. Using this new metric in conjunction with the traditional pixel value-based assessment will allow a more accurate quantitative assessment of nuclear medicineuniformity.

2.
J Nucl Med ; 42(7): 1121-7, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11438637

ABSTRACT

UNLABELLED: Emission tuned-aperture computed tomography (ETACT) is a new approach to acquiring and processing scintimammography data. A gamma camera with a pinhole collimator is used to acquire projections of the radionuclide distribution within the breast. Fiducial markers are used to reconstruct these projections into tomographic slices. Simulation and phantom experiments were performed to evaluate the potential of the ETACT method. METHODS: In the simulation study, a hemispheric object of 15 cm in diameter was constructed to model a breast. A ray-tracing technique was used to generate ideal projections. These were blurred and noise was added to create images that resemble scintigraphic images. Tumor size, pinhole size, and target-to-nontarget radioactivity ratios (TNTs) were varied. The simulated projections were reconstructed into slices, and contrast and contrast-to-noise ratios were calculated to evaluate the effect of pinhole size. These results were compared with a simulated planar acquisition of the same object. A preliminary phantom evaluation was performed using an 8-mm "tumor" with a 10:1 TNT to validate the simulation results. RESULTS: A 3-mm pinhole was shown by the simulation study to be the optimal size. The ETACT images consistently yielded higher contrast than simulated planar images. The phantom study validated the simulation results and showed the feasibility of ETACT in a simulated clinical environment. CONCLUSION: ETACT is shown to be useful for imaging tumors <1 cm in diameter. Because ETACT requires only a gamma camera with a pinhole collimator, it has the potential to be applied in any hospital in a simple, flexible, and practical manner.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Image Processing, Computer-Assisted , Tomography, Emission-Computed/methods , Female , Gamma Cameras , Humans , Phantoms, Imaging , Technetium , Tomography, Emission-Computed/instrumentation
3.
Anesth Analg ; 93(1): 45-52, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11429337

ABSTRACT

UNLABELLED: Dopamine has a wide spectrum of receptor and pharmacologic actions that may affect cerebral blood flow (CBF). A new, selective dopamine-1 agonist, fenoldopam, is a potent systemic vasodilator with moderate alpha(2)-receptor affinity. However, the effects of fenoldopam on the cerebral circulation are undefined. We therefore hypothesized that infusion of fenoldopam would decrease mean arterial blood pressure (MAP) and might concurrently decrease CBF via vascular alpha(2)-adrenoreceptor activation in awake volunteers. We studied nine healthy normotensive subjects, using positron emission tomography to measure CBF in multiple cortical and subcortical regions of interest. In addition, bioimpedance cardiac output and middle cerebral artery blood flow velocity were determined during fenoldopam-induced hypotension. Three men and four women, aged 25-43 yr, completed the study. Fenoldopam infused at 1.3 +/- 0.4 microg. kg(-1). min(-1) (mean +/- SD) reduced MAP 16% from baseline: from 94 (89-100) mm Hg (mean [95% confidence interval]) to 79 [74-85] mm Hg (P < 0.0001). During the fenoldopam infusion, both cardiac output (+39%), and heart rate (+45%) increased significantly, whereas global CBF decreased from baseline, 45.6 [35.6-58.5] mL. 100 g(-1). min(-1), to 37.7 [33.9-42.0] mL. 100 g(-1). min(-1) (P < 0.0001). Despite restoration of baseline MAP with a concurrent infusion of phenylephrine, global CBF remained decreased relative to baseline values at 37.9 [34.0-42.3] mL. 100 gm(-1). min(-1) (P < 0.0001). Changes in middle cerebral artery velocity did not correlate with positron emission tomography-measured changes of CBF induced by fenoldopam, with or without concurrent phenylephrine. IMPLICATIONS: In awake volunteers with (presumably) intact cerebral autoregulation,fenoldopam-induced hypotension significantly decreased global cerebral bloodflow (CBF). Clinicians should be aware of these pharmacodynamic effects when choosing a vasodilator to control blood pressure, especially in situations where control of CBF, cerebral blood volume, and intracranial pressure are therapeutic priorities.


Subject(s)
Antihypertensive Agents/pharmacology , Blood Pressure/drug effects , Cerebrovascular Circulation/drug effects , Dopamine Agonists/pharmacology , Fenoldopam/pharmacology , Adolescent , Adult , Brain/diagnostic imaging , Cardiac Output/drug effects , Depression, Chemical , Female , Heart Rate/drug effects , Humans , Male , Middle Aged , Receptors, Adrenergic, alpha-2/drug effects , Receptors, Dopamine D1/drug effects , Tomography, Emission-Computed , Ultrasonography, Doppler, Transcranial
4.
Chest ; 119(2): 333-9, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11171706

ABSTRACT

BACKGROUND: Positron emission tomography (PET) scanning is used increasingly to detect and stage lung cancer, but the test performance characteristics and relationship of PET to patient outcomes remain undefined. OBJECTIVE: To determine the test performance characteristics and relationship of PET scanning stage to patient outcomes relative to the 1997 International System for the Staging of Lung Cancer. DESIGN: Survival analysis using pathologic staging as the criterion standard for comparison of survival as predicted by staging by PET and CT. SETTING: University-based hospital. PATIENTS: All consecutive patients undergoing PET scanning for the evaluation of possible non-small cell lung cancer (NSCLC) during a 5-year period. MAIN OUTCOME MEASURES: Long-term survival of patients with NSCLC after staging by PET. RESULTS: One hundred fifty-two thoracic PET scans were obtained for the staging of possible NSCLC during a 5-year period. One hundred twenty-three patients (81%) demonstrated increased (18)F-fluorodeoxyglucose uptake. The overall sensitivity and specificity of PET for detecting malignancy were 95% and 67%, respectively, compared with 100% and 27% for chest CT. PET and CT had similar accuracy for staging the overall extent of disease (91% and 89%, respectively). PET stage correlated highly with survival using either nodal location or overall stage (p = 0.003, p = 0.002), as did pathologic staging (p = 0.0001, p = 0.0001). CT scan results did not accurately predict survival (p = 0.608, p = 0.338). CONCLUSION: PET scanning is a highly sensitive technologic advance in detecting and staging of thoracic malignancy and may more accurately predict the likelihood of long-term survival in patients with NSCLC than chest CT does.


Subject(s)
Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/pathology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Tomography, Emission-Computed , Carcinoma, Non-Small-Cell Lung/mortality , Fluorodeoxyglucose F18 , Humans , Lung Neoplasms/mortality , Neoplasm Staging/methods , Radiopharmaceuticals , Sensitivity and Specificity , Survival Analysis
5.
Head Neck ; 23(11): 942-6, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11754497

ABSTRACT

BACKGROUND: A single institution study was undertaken to evaluate the role of positron emission tomography (PET) scans with fluorodeoxyglucose (FDG) prior to radiation and following radiation. METHODS: Forty-five patients with head and neck cancers were evaluated with FDG-PET scans as well as either CT or MRI prior to treatment with definitive radiation (RT). These same scans were obtained following completion of RT at 1 month (36 patients), 4 months (28 patients), 12 months (19 patients), and 24 months (15 patients). Standard uptake values (SUV) normalized for blood glucose and lean body mass were calculated on the initial and 1-month post-treatment PET scans. RESULTS: Fifteen patients are alive without evidence of disease at 24 to 52 months following RT. Initial SUVs were calculated on the primary tumor site and ranged from 2.5 to 28.5. These values did not have any correlation with local control when examined for the entire group, primary site, or T stage. One-month post-RT SUV ranged from 1.8 to 6.24. Of the 36 1-month post-RT PET scans, six were interpreted as positive for residual disease and were confirmed by biopsy. Four of the five scans, which were interpreted as equivocal, were positive on biopsy. Seven of the 25 scans, which were interpreted as negative for tumor, were positive on biopsy. Four-month scans were more accurate for disease with disease noted in 0 of 18 negative scans, 6 of 7 positive scans, and 2 of 3 equivocal scans. CONCLUSIONS: PET is useful for initial imaging of head and neck cancers. SUV does not appear to be useful for predicting outcome following treatment with RT. One-month post-RT scans were inaccurate for predicting the presence of cancer. Four-month post-RT scans were a better predictor for the presence of cancer.


Subject(s)
Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Fluorodeoxyglucose F18 , Humans , Oropharyngeal Neoplasms/diagnostic imaging , Oropharyngeal Neoplasms/radiotherapy , Prognosis , Prospective Studies , Radionuclide Imaging , Radiopharmaceuticals
6.
Chest ; 118(6): 1610-5, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11115447

ABSTRACT

STUDY OBJECTIVE: Positron emission tomography (PET) can contribute to diagnosing and staging lung cancer, but it has not been determined whether this information influences patient care. DESIGN: We reviewed the effects of thoracic PET scan results during an 11-month period. For each patient, physicians ordering these scans reported how PET specifically altered management, and graded the ease of interpretation and overall usefulness of PET on a 5-point scale. In addition, to appraise general attitudes about PET, we surveyed 488 national American Thoracic Society (ATS) members and 44 physicians at our comprehensive cancer center. RESULTS: One hundred twenty-six questionnaires regarding patients were mailed to 37 ordering physicians, and 98 responses (78%) were returned, primarily by cardiothoracic surgeons (35%) and pulmonologists (47%). Respondents reported that PET provided new information in 83 patients (85%) and altered patient management in 64 cases (65%). Major effects on management included decisions regarding biopsy (n = 16), surgery (n = 16), and palliative treatment (n = 16). Chest clinicians found PET to be more helpful (4.4 vs 3.9, p = 0.007) and easier to interpret (4.2 vs 3.7, p = 0.025) than other specialists. Among 139 ATS members (28%) responding to the general survey, 51 members (39%) had access to PET. PET was more frequently available to university-based (49%) than community-based (27%) physicians (p = 0.016). The majority of physicians without current access to PET (69%) indicated that they would like to have it available. ATS members with access to PET reported that PET results generally affect decisions regarding biopsy or surgery most often, but found the procedure less helpful than physicians at our center (2.77 vs 3. 56, p = 0.003) and ordered it less often for lung cancer staging (60% vs 96%, p = 0.002). CONCLUSION: PET scanning is useful in the management of patients with suspected thoracic malignancies, but impressions about its roles vary, with PET regarded more highly where, as at our center, it is used more often. Whether PET alters patient outcomes requires investigation.


Subject(s)
Attitude of Health Personnel , Lung Neoplasms/diagnostic imaging , Tomography, Emission-Computed , Data Collection , Humans , Lung Neoplasms/therapy , Medicine , Practice Patterns, Physicians' , Pulmonary Medicine , Specialization , Thoracic Surgery , Tomography, Emission-Computed/statistics & numerical data
7.
J Comput Assist Tomogr ; 22(6): 953-61, 1998.
Article in English | MEDLINE | ID: mdl-9843239

ABSTRACT

PURPOSE: A tool (Gemini) was developed for quantifying regions of interest (ROIs) in registered MR and PET data. Its use was validated through phantom and simulated studies. METHOD: Hot spheres were imaged in a phantom (3:1 and 5:1 target-to-nontarget ratios). The computerized 3D Hoffman brain phantom was used to simulate PET studies. Spherical local activity features of two diameters (4 and 10 mm) and five intensities (5, 15, 25, 50, and 100% increase over gray matter) were added to the data in the thalamus and Brodmann area 37. The data were reprojected into sinograms and blurred with a 7 mm kernel. Poisson noise was added, and the sinograms were then reconstructed and analyzed using both SPM96 and Gemini spherical ROIs. RESULTS: Based on phantom and simulated data, the 95th percentile of intensity within a Gemini ROI afforded a reasonable joint optimization of variance (reliability) and accuracy (validity). SPM96 and Gemini results were similar for the larger (10 mm) feature, but in this application, Gemini was more sensitive than SPM96 for the small feature (4 mm). CONCLUSION: Gemini, a tool for display and measurement of spherical ROIs in registered PET and MR data, is precise and accurate for testing hypotheses of differences in localized brain activity, comparing favorably with SPM96.


Subject(s)
Brain/metabolism , Computer Simulation , Image Enhancement , Tomography, Emission-Computed , Magnetic Resonance Imaging , Phantoms, Imaging , Reproducibility of Results
9.
Eur J Orthod ; 20(2): 121-32, 1998 Apr.
Article in English | MEDLINE | ID: mdl-9633166

ABSTRACT

Mandibular advancement splints are successful in managing obstructive sleep apnoea (OSA) in selected subjects. For these to be effective, some improvement in the dimensions of the oropharyngeal airway must occur. Twenty subjects with proven obstructive sleep apnoea were examined using lateral cephalometric radiography and a fluoroscopic technique. Cephalograms were analysed, and assessed for both skeletal and soft tissue abnormalities known to be present in OSA subjects. On the basis of these, a prediction was made as to whether the subject's oropharyngeal airway would increase during mandibular protrusion. From the fluoroscopic sequences, the narrowest antero-posterior dimensions of the post-palatal and post-lingual airways were recorded as the mandible moved from the intercuspal position into maximal protrusion. The changes in airway size were noted and these were compared with the predictions made from the static films. In nine subjects, fluoroscopy indicated that the airway opened well during mandibular protrusion, seven did not improve and in four the changes were minimal. Post-palatally the mean airway increase was 2.6 mm, whilst behind the tongue a mean improvement of 3.1 mm was seen. In all but two instances, the cephalometric prediction agreed exactly with the outcome demonstrated by fluoroscopy. All subjects whose airways clearly increased were correctly identified by the cephalogram alone. Cephalometric features associated with a good airway response to protrusion were a reduced lower facial height, low maxillomandibular planes angle and a high hyoid position, accompanied by a normal anteroposterior relationship of the jaws, relatively normal mandibular body length and soft palate area. The more abnormal the skeletal and soft tissue dimensions, the poorer the prognosis. Thus, whilst a single radiograph could indicate whether a positive mandibular response to protrusion could be expected, where doubt existed, a fluoroscopic analysis could provide a useful adjunct to diagnosis.


Subject(s)
Mandibular Advancement/instrumentation , Occlusal Splints , Sleep Apnea Syndromes/diagnostic imaging , Sleep Apnea Syndromes/therapy , Adult , Aged , Cephalometry , Fluoroscopy , Humans , Middle Aged , Oropharynx/diagnostic imaging , Outcome Assessment, Health Care
10.
J Comput Assist Tomogr ; 21(4): 554-66, 1997.
Article in English | MEDLINE | ID: mdl-9216759

ABSTRACT

PURPOSE: The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after their results had been submitted. A secondary goal of the project is to evaluate the importance of correcting geometrical distortion in MR images by comparing the retrospective registration error in the rectified images, i.e., those that have had the distortion correction applied, with that of the same images before rectification. METHOD: Image volumes of three modalities (CT, MR, and PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/ or from PET to MR. These investigators communicated their transformations again via the Internet to Vanderbilt, where the accuracy of each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOIs), i.e., areas in the brain that would commonly be areas of neurological interest. A VOI is defined in the MR image and its centroid c is determined. Then, the prospective registration is used to obtain the corresponding point c' in CT or PET. To this point, the retrospective registration is then applied, producing c" in MR. Statistics are gathered on the target registration error (TRE), which is the distance between the original point c and its corresponding point c". RESULTS: This article presents statistics on the TRE calculated for each registration technique in this study and provides a brief description of each technique and an estimate of both preparation and execution time needed to perform the registration. CONCLUSION: Our results indicate that retrospective techniques have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.


Subject(s)
Brain/diagnostic imaging , Brain/pathology , Magnetic Resonance Imaging/methods , Teleradiology/methods , Tomography, Emission-Computed/methods , Tomography, X-Ray Computed/methods , Computer Communication Networks , Diagnostic Errors , Humans , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/standards , Magnetic Resonance Imaging/statistics & numerical data , Observer Variation , Prospective Studies , Retrospective Studies , Sensitivity and Specificity , Teleradiology/standards , Teleradiology/statistics & numerical data , Tomography, Emission-Computed/instrumentation , Tomography, Emission-Computed/standards , Tomography, Emission-Computed/statistics & numerical data , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/standards , Tomography, X-Ray Computed/statistics & numerical data
11.
J Nucl Med ; 37(10): 1639-43, 1996 Oct.
Article in English | MEDLINE | ID: mdl-8862299

ABSTRACT

UNLABELLED: This study compared the different calculation methods of the solid gastric emptying lag phase and evaluated the effect of the temporal sampling interval on the calculated value using the modified power exponential (MPE) method. METHODS: Twenty normal control subjects and 42 patients had anterior and posterior image acquisition on a multihead gamma camera, one frame per minute x 90. ROIs were selected for the stomach, gastric antrum and small bowel. Time-activity curves (TACs) were generated for anterior, posterior and geometric mean data. The lag phase was calculated using various methods such as transition point, starting index, first appearance of bowel activity (FABA), MPE and antral peak filling time. To determine the importance of the temporal sampling rate on the calculation of the lag phase by the MPE, intervals between 1 and 20 min were analyzed. RESULTS: The transition point, starting index and FABA correlated extremely high (r = > or = 0.92) in normal control subjects and patients. Normal lag phase values were mean 22-24 +/- 10 min for transition point, starting index and FABA compared with 47 +/- 18 min for the MPE method (p < 0.0001). The MPE correlated poorly with the other method (r = 0.74). Antral peak filling time correlated poorly (r = 0.47) with transition point, starting index and FABA, but somewhat better with the MPE (r = 0.70). Comparing 15-min versus 1-min sampling intervals using the MPE, 35% of subjects had values that differed by > or = 7.5 min and 10% had values differing by > or = 15 min. CONCLUSION: The lag phase calculated by the MPE correlated poorly with other methods, and its accuracy was limited by the rate of the temporal sampling. The transition point, starting index and FABA all highly correlated with each other; the latter is a particularly reliable physiological indicator and is easily quantified using a small-bowel TAC.


Subject(s)
Gastric Emptying , Stomach/diagnostic imaging , Adolescent , Adult , Female , Gastrointestinal Diseases/diagnostic imaging , Gastrointestinal Diseases/physiopathology , Humans , Male , Radionuclide Imaging , Technetium Tc 99m Sulfur Colloid , Time Factors
12.
J Oral Rehabil ; 23(10): 699-711, 1996 Oct.
Article in English | MEDLINE | ID: mdl-8933387

ABSTRACT

The aim of this study was to develop a method of studying the effects of mandibular advancement on oropharyngeal airway dimensions in the sagittal plane in conscious, supine patients. Six white, dentate, male patients with proven obstructive sleep apnoea had sagittal fluoroscopic recordings taken in the resting supine position. Images were recorded at four frames per second as the mandible was advanced with the teeth in contact to maximum protrusion and then opened. Software in the fluoroscopic imaging system permitted measurement of the change in mandibular position together with oropharyngeal airway dimensions expressed as the narrowest dimension observable in the post-palatal and post-lingual sites. Plotting of airway dimensions during mandibular advancement enabled estimation of the degree of protrusion associated with maximal airway benefits. Progressive mandibular advancement produced variable adaptive changes in the post-palatal and post-lingual regions of the oropharynx. The amount of airway opening appeared to be related to the horizontal and vertical relationships of the face and to the dimensions of the soft palate. The changes in post-palatal and post-lingual airway dimensions were not always identical, despite the observation that both tongue and soft palate were seen to move in unison, with close contact being maintained between the two structures. Jaw opening resulted in synchronous posterior movement of both tongue and soft palate, with consequent narrowing of oropharyngeal airspace. Fluoroscopy is a simple method of assessing upper airway changes with mandibular advancement in the conscious patient. The technique should facilitate the selection of subjects for whom mandibular advancement would seem advantageous. The nature of the adaptive response is dependent on individual structural variation. It is suggested that, where artificial mandibular advancement with dental devices is considered beneficial, jaw opening should be kept to a minimum.


Subject(s)
Mandible/physiopathology , Oropharynx/physiology , Sleep Apnea Syndromes/physiopathology , Sleep Apnea Syndromes/therapy , Adaptation, Physiological , Cephalometry , Fluoroscopy , Humans , Male , Mandibular Advancement/instrumentation , Mandibular Advancement/methods , Oropharynx/diagnostic imaging , Oropharynx/physiopathology , Palate, Soft/physiopathology , Patient Selection , Pilot Projects , Prognosis , Sleep Apnea Syndromes/diagnostic imaging , Splints , Tongue/physiopathology
13.
Todays Surg Nurse ; 18(3): 16-20, 1996.
Article in English | MEDLINE | ID: mdl-8974767

ABSTRACT

Hydroxyapatite, a coral, provides an effective foundation for a prosthetic eye. With the implant, the prosthetic eye has a normal appearance, including movement. The infusion of blood into the implant prevents it from behaving as a foreign object in the patient's body.


Subject(s)
Durapatite , Eye Enucleation/nursing , Eye, Artificial , Eye Enucleation/methods , Humans , Perioperative Nursing
14.
J Oral Rehabil ; 23(1): 72-7, 1996 Jan.
Article in English | MEDLINE | ID: mdl-8850165

ABSTRACT

Obstructive sleep apnoea may present with a wide range of symptoms resulting in a variety of referral pathways. A multidisciplinary approach to examination and diagnosis helps to determine the most appropriate treatment plan for each individual. The subject is seen by each member of the team, appropriate investigations undertaken and a further meeting arranged at which all opinions are discussed. A reasoned treatment regime is produced, taking into consideration the patient's wishes and overall medical condition. This paper describes the team approach currently employed in the Department of Thoracic Medicine at The Prince Charles Hospital, Brisbane, Australia. The thoracic physician and ENT surgeon work in close collaboration with their dental colleagues: an orthodontist, prosthodontist and a maxillofacial surgeon. An outline of the examination and investigations made by each is described and the multidisciplinary approach is illustrated by a description of the management of five subjects with suspected obstructive sleep apnoea.


Subject(s)
Patient Care Team , Sleep Apnea Syndromes/diagnosis , Adult , Aged , Airway Obstruction/diagnosis , Airway Obstruction/therapy , Clinical Protocols , Humans , Middle Aged , Patient Care Planning , Polysomnography , Referral and Consultation , Sleep Apnea Syndromes/therapy , Snoring/diagnosis , Snoring/therapy
15.
J Nucl Med ; 36(12): 2333-8, 1995 Dec.
Article in English | MEDLINE | ID: mdl-8523127

ABSTRACT

UNLABELLED: The purpose of this study was to develop an accurate, retrospectively applicable procedure for registering thoracic studies from different modalities in a short amount of time and with minimal operator intervention. METHODS: CT and PET studies were acquired from six patients. The pleural surfaces in both image sets were determined by segmenting based on 50% of the maximum soft-tissue value in the study. These surfaces were converted into three-dimensional volumes and used to register the CT and PET studies in three dimensions using a sum of least squares fitting approach. The registered PET study was then displayed in a hot metal scale overlayed on top of the gray scale CT study. The accuracy of the fit was evaluated through a phantom study and preliminary clinical evaluation. RESULTS: A phantom study was performed to determine the limits of this technique. The accuracy was determined to be less than 2.3 mm in the x and y direction and 3 mm in the z direction. Preliminary clinical evaluation was also performed with encouraging results. CONCLUSION: This technique accurately registers PET and CT images of the thorax, retrospectively, without the need for external fiducial markers or other a priori action.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Lung Neoplasms/diagnosis , Tomography, Emission-Computed , Tomography, X-Ray Computed , Aged , Carcinoma, Bronchogenic/diagnosis , Carcinoma, Squamous Cell/diagnosis , Deoxyglucose/analogs & derivatives , Female , Fluorine Radioisotopes , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Phantoms, Imaging , Time Factors
16.
J Oral Rehabil ; 22(8): 607-12, 1995 Aug.
Article in English | MEDLINE | ID: mdl-7472733

ABSTRACT

Obstructive sleep apnoea may present with a wide range of symptoms resulting in a variety of referral pathways. A multidisciplinary approach to examination and diagnosis helps to determine the most appropriate treatment plan for each individual. The subject is seen by each member of the team, appropriate investigations undertaken and a further meeting arranged at which all opinions are discussed. A reasoned treatment regime is produced, taking into consideration the patient's wishes and overall medical condition. This paper describes the team approach currently employed in the Department of Thoracic Medicine at The Prince Charles Hospital, Brisbane, Australia. The thoracic physician and ENT surgeon work in close collaboration with their dental colleagues: an orthodontist, prosthodontist and a maxillofacial surgeon. An outline of the examination and investigations made by each is described and the multidisciplinary approach is illustrated by a description of the management of five subjects with suspected obstructive sleep apnoea.


Subject(s)
Patient Care Team , Sleep Apnea Syndromes/diagnosis , Adult , Aged , Cephalometry , Dentistry , Humans , Middle Aged , Otolaryngology , Polysomnography , Referral and Consultation , Sleep Apnea Syndromes/therapy , Thoracic Surgery
17.
J Nucl Med ; 35(11): 1777-80, 1994 Nov.
Article in English | MEDLINE | ID: mdl-7965155

ABSTRACT

UNLABELLED: The intent of this investigation was to quantitate the amount of misregistration between PET emission and transmission scans of the thorax that occurs in a normal clinical environment. METHODS: The data from 17 FDG myocardial studies were evaluated. Prior to injection, a transmission study was acquired for 15 min using a 68Ge/68Ga ring source. The location of the cross-hairs from a laser alignment system was marked on the patient who was then removed from the scanner and injected with 10 mCi of FDG. After 45 min, the patient was placed back on the table and repositioned with the previously placed marks and a 15-min emission scan was acquired. The outline of the lungs on both the transmission and emission images was manually segmented. Both attenuation-corrected and noncorrected emission images were evaluated and the one that provided clearer visualization of the outline of the lungs was chosen for segmentation. The segmented contours of the transmission and emission scans were then registered with the method described by Pelizzari et al. using the transmission image as the "head" and the emission image as the "hat." The allowable transformations were x and y shifts and rotation in the transverse plane. RESULTS: Shifts in the x-axis averaged 2.4 mm (range: 0.2-7.3 mm, 80% less than 3.3 mm) with shifts in the y-axis averaging 2.6 mm (range: 0.1-8.7 mm, 80% less than 2.4 mm) and rotations in the transverse plane averaging 1.6 degrees (range: 0.2 to 5.1 degrees, 80% less than 2.4 degrees). A phantom study indicated that the accuracy of this method of evaluating misregistration was 2.35 mm and 1.81 mm in the x and y directions, respectively. CONCLUSION: Our preliminary evaluation indicates that careful application of laser alignment is an adequate method of registration in most cases.


Subject(s)
Deoxyglucose/analogs & derivatives , Fluorine Radioisotopes , Heart/diagnostic imaging , Tomography, Emission-Computed , Algorithms , Evaluation Studies as Topic , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Models, Structural , Retrospective Studies , Tomography, Emission-Computed/instrumentation , Tomography, Emission-Computed/methods
18.
AJR Am J Roentgenol ; 163(2): 417-21, 1994 Aug.
Article in English | MEDLINE | ID: mdl-8037042

ABSTRACT

OBJECTIVE: Although the prevalence of intracranial lymphoma is high among patients with AIDS, current imaging techniques are not reliable for differentiating this tumor from other common nonneoplastic lesions, such as those seen in toxoplasmosis. The purpose of this study was to prospectively investigate the use of 201Tl single-photon emission computed tomography (SPECT) in identifying intracranial lymphoma in patients with AIDS. SUBJECTS AND METHODS: Thirteen patients with AIDS and intracranial masses underwent 201Tl imaging with a three-headed SPECT camera. Sic of the 13 were subsequently proved to have lymphoma. Studies were interpreted prospectively as showing tumor if uptake of 201Tl was increased in the region where the lesion was seen on MR images. A lesion-to-nonlesion uptake ratio (counts/pixel) was calculated retrospectively. RESULTS: The SPECT images of six patients were interpreted prospectively as showing no lymphoma. Uptake ratios in these six patients were 0.77-1.95 (mean, 1.45). In each, tumor was excluded as a final diagnosis (four had toxoplasmosis, one had progressive multifocal leukoencephalopathy, and one had venous angioma). Among the seven patients with SPECT images interpreted as showing lymphoma, six were later proved to have lymphoma (uptake ratio: mean, 3.65; range, 2.95-4.30; p < .005). The SPECT findings in the seventh patient were classified as false-positive for tumor on the basis of the prospective interpretation of the images; three concurrent infections were found at autopsy. The uptake ratio in this patient was low (1.81), suggesting that quantification might have diagnostic usefulness for improving accuracy. CONCLUSION: This preliminary study indicates that 201Tl SPECT might be a useful, noninvasive method for differentiating intracranial lymphoma from nonneoplastic lesions in patients with AIDS.


Subject(s)
Brain Neoplasms/diagnostic imaging , Lymphoma, AIDS-Related/diagnostic imaging , AIDS-Related Opportunistic Infections/diagnostic imaging , Adult , Brain/diagnostic imaging , Brain/pathology , Brain Neoplasms/diagnosis , Brain Neoplasms/epidemiology , Diagnosis, Differential , Female , Humans , Lymphoma, AIDS-Related/diagnosis , Lymphoma, AIDS-Related/epidemiology , Magnetic Resonance Imaging , Male , Prospective Studies , Retrospective Studies , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon , Toxoplasmosis, Cerebral/diagnostic imaging
19.
Int J Radiat Oncol Biol Phys ; 29(4): 841-5, 1994 Jul 01.
Article in English | MEDLINE | ID: mdl-8040032

ABSTRACT

PURPOSE: Distinguishing persistent or recurrent tumor from postradiation edema, or soft tissue/cartilage necrosis in patients treated for carcinoma of the larynx can be difficult. Because recurrent tumor is often submucosal, multiple deep biopsies may be necessary before a diagnosis can be established. Positron emission tomography with 18F-2fluoro-2deoxyglucose (FDG) was studied for its ability to aid in this problem. METHODS AND MATERIALS: Positron emission tomography (18FDG) scans were performed on 11 patients who were suspected of having persistent or recurrent tumor after radiation treatment for carcinoma of the larynx. Patients underwent thorough history and physical examinations, scans with computerized tomography, and pathologic evaluation when indicated. Standard uptake values were used to quantitate the FDG uptake in the larynx. RESULTS: The time between completion of radiation treatment and positron emission tomography examination ranged from 2 to 26 months with a median of 6 months. Ten patients underwent computed tomography (CT) of the larynx, which revealed edema of the larynx (six patients), glottic mass (four patients), and cervical nodes (one patient). Positron emission tomography scans revealed increased FDG uptake in the larynx in five patients and laryngectomy confirmed the presence of carcinoma in these patients. Five patients had positron emission tomography results consistent with normal tissue changes in the larynx, and one patient had increased FDG uptake in neck nodes. This patient underwent laryngectomy, and no cancer was found in the primary site, but nodes were pathologically positive. One patient had slightly elevated FDG uptake and negative biopsy results. The remaining patients have been followed for 11 to 14 months since their positron emission studies and their examinations have remained stable. In patients without tumor, average standard uptake values of the larynx ranged from 2.4 to 4.7, and in patients with tumor, the range was 4.9 to 10.7. CONCLUSION: Positron emission tomography with labeled FDG appears to be useful in distinguishing benign from malignant changes in the larynx after radiation treatment. This noninvasive technique may be preferable to biopsy, which could traumatize radiation-damaged tissues and precipitate necrosis.


Subject(s)
Laryngeal Neoplasms/diagnostic imaging , Laryngeal Neoplasms/radiotherapy , Neoplasm Recurrence, Local/diagnostic imaging , Radiation Injuries/diagnostic imaging , Deoxyglucose/analogs & derivatives , Deoxyglucose/pharmacokinetics , Diagnosis, Differential , Edema/diagnosis , Edema/etiology , Fluorine Radioisotopes , Fluorodeoxyglucose F18 , Humans , Laryngeal Neoplasms/metabolism , Laryngectomy , Larynx/diagnostic imaging , Larynx/metabolism , Larynx/surgery , Necrosis , Neoplasm Recurrence, Local/diagnosis , Neoplasm Recurrence, Local/metabolism , Radiation Injuries/diagnosis , Radiation Injuries/metabolism , Radiotherapy/adverse effects , Tomography, Emission-Computed
20.
Radiology ; 192(1): 99-102, 1994 Jul.
Article in English | MEDLINE | ID: mdl-8208973

ABSTRACT

PURPOSE: To determine whether positron emission tomography (PET) can help differentiate benign from malignant lesions of the salivary glands before surgery. MATERIALS AND METHODS: Masses of the salivary glands were examined in 26 patients by means of computed tomography, magnetic resonance imaging, PET, biopsy (n = 18), and surgery. Contiguous PET scans were obtained from the midcranium to the lower chest 45 minutes after administration of 370 MBq (10 mCi) of fluorine-18 fluorodeoxyglucose (FDG). Standard uptake values (SUVs) were determined for all suspect lesions and for normal parotid glands and cerebellum. RESULTS: All lesions were visualized, and all but two showed some increase in FDG uptake. PET findings helped correctly differentiate benign from malignant masses in 18 (69%) but were false-positive for malignancy in eight (31%). SUV analysis, lesion-to-normal SUV ratios, and lesion-to-cerebellar SUV ratios also failed to differentiate the lesions. CONCLUSION: FDG PET is not useful in classifying salivary gland tumors as benign or malignant.


Subject(s)
Salivary Gland Neoplasms/diagnostic imaging , Tomography, Emission-Computed , Adult , Aged , Aged, 80 and over , Biopsy , Contrast Media , Deoxyglucose/analogs & derivatives , Diagnosis, Differential , False Positive Reactions , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Salivary Gland Neoplasms/diagnosis , Salivary Gland Neoplasms/surgery , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...