Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Surg Res ; 140(1): 6-11, 2007 Jun 01.
Article in English | MEDLINE | ID: mdl-17481980

ABSTRACT

BACKGROUND: Effective laparoscopic ventral herniorrhaphy usually mandates the use of an intraperitoneal prosthetic. Visceral adhesions and changes in textile characteristics of prosthetics may complicate repairs, especially long-term. The aim of this study was to compare the adhesion formation, tissue ingrowth, and textile characteristics one year after intra-abdominal placement of the commonly used prosthetic meshes. MATERIALS AND METHODS: Forty (4 x 4 cm) meshes were sutured using absorbable suture to an intact peritoneum in 20 New Zealand white rabbits. The study groups included: polypropylene (PP) [Marlex; C.R. Bard Inc, Cranston, NJ], expanded polytetrafluoroethylene (ePTFE) [DualMesh; WL Gore, Flagstaff, AZ], ePTFE and PP (ePTFE/PP) [Composix, C.R. Bard Inc], reduced weight PP and oxidized regenerated cellulose (rPP/C) [Proceed; Ethicon, Inc, Somerville, NJ]. The meshes were explanted after one year. Adhesions were scored as a percentage of explanted biomaterials' affected surface area. Prosthetic shrinkage was calculated. The strength of incorporation and mesh compliance were evaluated using differential variable reluctance transducers. Mesh ingrowth was measured as the load necessary to distract the mesh/tissue complex. Mesh compliance was calculated as the change in linear displacement of the sensors due to applied load. The groups were compared using Student's t-test and Fisher's exact test. RESULTS: ePTFE had significantly less adhesions (0%) than both ePTFE/PP (40%) and PP (80%) groups (P < 0.001). The mean area of adhesions for the rPP/C (10%) and the ePTFE/PP (14%) groups was less than that for the PP group (40%) (P = 0.02). Prosthetic shrinkage was greatest in the ePTFE (32%) group than in any other group (P = 0.001). There were no differences in mesh incorporation between the groups. At explantation, mesh compliance in the ePTFE group was superior to other meshes (P < 0.0001). The rPP/C mesh induced the smallest change in the compliance of the tissue adjacent to the mesh (P = 0.0001). CONCLUSIONS: Prosthetic materials demonstrate a wide variety of characteristics. Although exposed PP formed the most adhesions, up to 40% of the other PP-based meshes formed adhesions despite protective barriers. The ePTFE mesh did not induce adhesions and was the most compliant, however, this prosthetic's contraction was greatest. Reduced weight polypropylene (rPP/C) mesh induced the smallest change in the adjacent tissue pliability/compliance. Understanding of the long-term effects of various prosthetic materials is important to ensure an adequate hernia repair while minimizing postoperative morbidity and patient discomfort.


Subject(s)
Hernia, Abdominal/surgery , Materials Testing , Prostheses and Implants/adverse effects , Surgical Mesh/adverse effects , Tissue Adhesions/prevention & control , Abdomen , Animals , Biomechanical Phenomena , Laparoscopy , Polytetrafluoroethylene/adverse effects , Postoperative Complications/prevention & control , Prosthesis Failure , Rabbits
2.
Surg Technol Int ; 16: 123-7, 2007.
Article in English | MEDLINE | ID: mdl-17429779

ABSTRACT

The search for safe and effective means of herniorrhaphies has been ongoing for more than a century. Evidence strongly supports tension-free hernia repairs in most patients, which result in a 50% reduction in a ten-year cumulative rate of hernia recurrence compared with tissue repairs. Polypropylene mesh revolutionized the field approximately 50 years ago; however, limitations of traditional polypropylene mesh have fueled the research and development of other prosthetic and biologic mesh products. Newer polyester and expanded polytetrafluoroethylene (ePTFE) products are designed to improve pliability and reduce adhesiogenic potential. Combination meshes capitalize on the ideal properties of biomaterials by strategically positioning particular mesh surfaces to selectively impede or promote tissue ingrowth. The most recent improvement in mesh products is the introduction of "lightweight" meshes. In response to mounting evidence that the traditional formulations of polypropylene meshes are over-engineered, lightweight meshes were designed with less polypropylene per surface area. Future research may prove that most meshes used currently are "mechanical overkill," which may lead to a widespread use of lightweight meshes to provide a durable repair, minimize chronic mesh-related discomfort, and improve the overall quality of life of hernia patients.


Subject(s)
Herniorrhaphy , Laparoscopy/methods , Plastic Surgery Procedures/instrumentation , Plastic Surgery Procedures/methods , Surgical Mesh , Equipment Design , Equipment Failure Analysis , Humans
3.
Surg Endosc ; 21(7): 1170-4, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17285375

ABSTRACT

BACKGROUND: Placement of an intraperitoneal prosthetic is required for laparoscopic ventral hernia repair. The biocompatibility of these prosthetics determines the host's inflammatory response, scar plate formation, tissue ingrowth, and subsequent mesh performance, including prosthetic compliance and prevention of hernia recurrence. We evaluated the host response to intraperitoneal placement of several prosthetics currently used in clinical practice. METHODS: A 4-cm x 4-cm piece of mesh was implanted on intact peritoneum in New Zealand white rabbits. The mesh types included expanded polytetrafluoroethylene (ePTFE) (DualMesh), ePTFE and polypropylene (Composix, heavyweight polypropylene), polypropylene and oxidized regenerated cellulose (Proceed, midweight polypropylene), and polypropylene (Marlex, heavyweight polypropylene). At four months, standard hematoxylin and eosin and Milligan's trichrome stains of the mesh-tissue interaction were analyzed by three observers blinded to the mesh types. Each specimen was evaluated for scar plate formation, inflammatory response, and tissue ingrowth. Each of these three categories was graded on a standard scale of 1-4 (1 = normal tissue and 4 = severe inflammatory response). The scores were analyzed using Wilcoxon rank sum test with p < 0.05 as significant. RESULTS: Ten samples of each mesh type were evaluated. There was no difference in tissue incorporation between the groups. The mean scar plate formation was greater in the heavyweight polypropylene meshes than for DualMesh (p = 0.04). With Proceed, the reduction in scar plate formation compared with that for Composix and Marlex approached statistical significance (p = 0.07). The mean number of inflammatory cells was greater around the ePTFE when compared with the midweight polypropylene (p = 0.02) but equal to the other meshes. CONCLUSIONS: The four prosthetic materials evaluated in this study demonstrate comparable host biocompatibility as evidenced by the tissue ingrowth. Scar plate formation around DualMesh was significantly less than that around Composix and Marlex. Interestingly, more inflammatory cells were noted surrounding the DualMesh which was equal to that of the heavyweight meshes. Proceed, a midweight polypropylene mesh, has the potential for improved patient tolerance compared to heavyweight polypropylene meshes based on its favorable histologic findings.


Subject(s)
Hernia, Abdominal/surgery , Polypropylenes/analysis , Polytetrafluoroethylene/analysis , Postoperative Complications/pathology , Surgical Mesh , Animals , Disease Models, Animal , Evaluation Studies as Topic , Female , Hernia, Abdominal/pathology , Immunohistochemistry , Laparoscopy/methods , Male , Materials Testing , Probability , Prosthesis Implantation , Rabbits , Random Allocation , Statistics, Nonparametric
4.
Surgery ; 140(6): 914-20; discussion 919-20, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17188138

ABSTRACT

BACKGROUND: Improvements in the sensitivity of radiographic imaging have lead to an increase in the number of adrenal masses diagnosed. The purpose of this study is to determine if technologic advancements have resulted in the diagnosis of earlier-staged adrenal cortical cancer (ACC) and to determine if the survival of patients with ACC has improved over the past 15 years. METHODS: Patients with ACC were identified in the Surveillance, Epidemiology, and End Results database between 1988 and 2002. Changes in demographics, stage, size, and treatment were analyzed by standard statistical testing. RESULTS: We identified 602 patients with a mean age of 53 years and an average tumor size of 11.8 cm. Two hundred thirty-eight (39.5%) patients presented with localized disease (stages I and II), and 311 (52%) patients presented with advanced disease (stages III and IV). The comparison of smaller lesions and number of patients were 5 to 6 cm in 24 (4%) patients, 4 to 5 cm in 27 (4.5%) patients, and <4 cm in 19 (3.1%) patients. Patients with masses less than 5 cm were statistically more likely to have localized disease (P <. 001). Age (P = .10), tumor size (P = .85), tumor stage (P = .45), and 5-year survival (P = .5) did not change over the 15-year study. CONCLUSIONS: Over the 15-year study, patients with ACC were not diagnosed at an earlier stage or with tumors smaller, and survival did not improve.


Subject(s)
Adrenal Cortex Neoplasms/diagnosis , Adrenal Cortex Neoplasms/pathology , Neoplasm Staging , SEER Program/statistics & numerical data , Adrenal Cortex Neoplasms/mortality , Adrenal Glands/pathology , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prognosis , Survival Rate , United States/epidemiology
5.
Surg Innov ; 13(2): 109-14, 2006 Jun.
Article in English | MEDLINE | ID: mdl-17012151

ABSTRACT

The laparoscopic approach is preferred for most adrenal tumors but technical challenges limit its use. We evaluated the effects of the availability of laparoscopic expertise on the volume of the adrenal surgery at a tertiary care hospital. Patients undergoing adrenalectomy 5 years before and 5 years after an advanced laparoscopic program was established were retrospectively reviewed. The average annual volume increased from 2 cases during the first period to 15 cases during the 5 years (1999-2003) after laparoscopic expertise became available. The average distance of travel to the hospital was significantly greater for the latter patients and significantly more patients were referred from outside of a 30-mile radius. Although the average statewide annual number of adrenalectomies has not significantly changed, the proportion of adrenalectomies performed at our institution rose. Offering a laparoscopic approach has altered physicians' referral patterns and has significantly increased the volume of adrenal surgery at the institution.


Subject(s)
Adrenal Gland Diseases/surgery , Adrenalectomy/statistics & numerical data , Clinical Competence , Health Services Accessibility , Laparoscopy/statistics & numerical data , Adult , Female , Humans , Male , Middle Aged , North Carolina , Referral and Consultation/statistics & numerical data , Retrospective Studies
6.
Am Surg ; 72(9): 808-13; discussion 813-4, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16986391

ABSTRACT

Laparoscopic ventral hernia repair requires an intraperitoneal prosthetic; however, these materials are not without consequences. We evaluated host reaction to intraperitoneal placement of various prosthetics and the functional outcomes in an animal model. Mesh (n = 15 per mesh type) was implanted on intact peritoneum in New Zealand white rabbits. The mesh types included ePTFE (DualMesh), ePTFE and polypropylene (Composix), polypropylene and oxidized regenerated cellulose (Proceed), and polypropylene (Marlex). Adhesion formation was evaluated at 1, 4, 8, and 16 weeks using 2-mm mini-laparoscopy. Adhesion area, adhesion tenacity, prosthetic shrinkage, and compliance were evaluated after mesh explantation at 16 weeks. DualMesh had significantly less adhesions than Proceed, Composix, or Marlex at 1, 4, 8, and 16 weeks (P < 0.0001). Marlex had significantly more adhesions than other meshes at each time point (P < 0.0001). There were no statistically significant differences in adhesions between Proceed and Composix meshes. After mesh explantation, the mean area of adhesions for Proceed (4.6%) was less than for Marlex (21.7%; P = 0.001). The adhesions to Marlex were statistically more tenacious than the DualMesh and Composix groups. Overall prosthetic shrinkage was statistically greater for DualMesh (34.7%) than for the remaining mesh types (P < 0.01). Mesh compliance was similar between the groups. Prosthetic materials demonstrate a wide variety of characteristics when placed inside the abdomen. Marlex formed more adhesions with greater tenacity than the other mesh types. DualMesh resulted in minimal adhesions, but it shrank more than the other mesh types. Each prosthetic generates a varied host reaction. Better understanding of these reactions can allow a suitable prosthetic to be chosen for a given patient in clinical practice.


Subject(s)
Biocompatible Materials/adverse effects , Hernia, Ventral/surgery , Prostheses and Implants/adverse effects , Surgical Mesh/adverse effects , Tissue Adhesions/etiology , Animals , Disease Models, Animal , Fluorocarbon Polymers/adverse effects , Laparoscopy/adverse effects , Laparoscopy/methods , Polypropylenes/adverse effects , Prospective Studies , Rabbits
7.
Am Surg ; 72(6): 474-80, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16808197

ABSTRACT

Laparoscopic appendectomy (LA) has gained in popularity in recent years. The number of elderly patients undergoing appendectomy has increased as that segment of the population has increased in number; however, the utility and benefits of LA in the elderly population are not well established. We hypothesized that LA in the elderly has distinctive advantages in perioperative outcomes over open appendectomy (OA). We queried the 1997 to 2003 North Carolina Hospital Association Patient Data System for all patients with the primary ICD-9 procedure code for OA and LA. Patients > or = 65 years of age (elderly) were identified and reviewed. Outcomes including length of stay (LOS), charges, complications, discharge location, and mortality were compared between the groups. There were 29,244 appendectomies performed in adult patients (>18 years old) with 2,722 of these in the elderly. The annual percentage of LA performed in the elderly increased from 1997 to 2003 (11.9-26.9%, P < 0.0001). When compared with OA, elderly patients undergoing LA had a shorter LOS (4.6 vs 7.3 days, P = 0.0001), a higher rate of discharge to home (91.4 vs 78.9%, P = 0.0001) as opposed to a step-down facility, fewer complications (13.0 vs 22.4%, P = 0.0001), and a lower mortality rate (0.4 vs 2.1%, P = 0.007). When LA was compared with OA in elderly patients with perforated appendicitis, LA resulted in a shorter LOS (6.8 vs 9.0 days, P = 0.0001), a higher rate of discharge to home (86.6 vs 70.9%, P = 0.0001), but equivalent total charges (dollars 22,334 vs dollars 23,855, P = 0.93) and mortality (1.0 vs 2.98%, P = 0.10). When elderly patients that underwent LA were compared with adult patients (18-64 years old), they had higher total charges (dollars 16,670 vs dollars 11,160, P = 0.0001) but equivalent mortality (0.37 vs 0.15%, P = 0.20). The use of laparoscopy in the elderly has significantly increased in recent years. In general, the safety and efficacy of LA is demonstrated by a reduction in mortality, complications, and LOS when compared with OA. The laparoscopic approach to the perforated appendix in the elderly patient has advantages over OA in terms of decreased LOS and a higher rate of discharge to home as opposed to rehabilitation centers, nursing homes, or skilled nursing care. When compared with all younger adults, the laparoscopic approach in the elderly was associated with equal mortality rates even though hospitalization charges were higher. Laparoscopy may be the preferred approach in elderly patients who require appendectomy.


Subject(s)
Appendectomy/adverse effects , Appendicitis/surgery , Laparoscopy , Aged , Appendectomy/economics , Appendicitis/complications , Female , Hospital Charges , Humans , Laparoscopy/economics , Length of Stay/economics , Male , Patient Discharge , Retrospective Studies , Treatment Outcome
8.
Surg Innov ; 12(2): 155-60, 2005 Jun.
Article in English | MEDLINE | ID: mdl-16034506

ABSTRACT

Various sources of ultrasonic and thermal energy have been developed to facilitate blood vessel ligation. However, their efficacy in sealing lymphatics has not been clearly established to date. We hypothesized that the electrosurgical bipolar vessel sealer (EBVS) produces reliable and durable sealing of large lymphatic vessels in a porcine model. Thoracic ducts from 4 adult pigs were explanted and sealed at multiple levels by using 3 different EBVS devices: LigaSure Atlas, XTD, and V. Fifteen seals (5 per group) were analyzed for sealing time and visual quality. Seal burst strength was measured by using a graduated pressure saline injection system. Twelve intact seals also underwent a histologic analysis. The mean overall burst strength of the seals was 271+/-78 mm Hg (127 to 360 mm Hg). The burst pressures in the 3 groups were not statistically different. The overall mean time to achieve a seal was 5.1+/-2.2 seconds (3 to 10 seconds). Seals were achieved significantly faster in the V group (4.1+/-0.6 seconds) compared with the Atlas (6.3+/-2.3 seconds) and XTD (6.4+/-2.6 seconds) groups. Qualitative seal assessment revealed minimal sticking and charring, a favorable degree of seal tissue clarity, and desiccation in the 3 groups. Histologic analysis demonstrated a fusion of lymphovascular channels with a complete obliteration of the lumens. We demonstrated that the use of EBVS results in a fast and effective sealing of large porcine lymphatic vessels. The seals created by all 3 devices burst at markedly supraphysiologic intraluminal pressures. Ongoing randomized human trials may prove the clinical benefits of the routine use of EBVS devices for various tissue dissections.


Subject(s)
Electrocoagulation/instrumentation , Thoracic Duct/surgery , Vascular Surgical Procedures/instrumentation , Animals , Biomechanical Phenomena , Female , Models, Animal , Swine , Thoracic Duct/physiology
9.
Am J Surg ; 190(2): 239-43, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16023438

ABSTRACT

BACKGROUND: Laparoscopic surgery has developed out of multiple technology innovations and the desire to see beyond the confines of the human body. As the instrumentation became more advanced, the application of this technique followed. By revisiting the historical developments that now define laparoscopic surgery, we can possibly foresee its future. DATA SOURCES: A Medline search was performed of all the English-language literature. Further references were obtained through cross-referencing the bibliography cited in each work and using books from the authors' collection. CONCLUSION: Minimally invasive surgery is becoming important in almost every facet of abdominal surgery. Optical improvements, miniaturization, and robotic technology continue to define the frontier of minimally invasive surgery. Endoluminal resection surgery, image-guided surgical navigation, and remotely controlled robotics are not far from becoming reality. These and advances yet to be described will change laparoscopic surgery just as the electric light bulb did over 100 years ago.


Subject(s)
Digestive System Diseases/surgery , Laparoscopy/standards , Minimally Invasive Surgical Procedures/standards , Abdomen/surgery , Digestive System Diseases/diagnosis , Digestive System Surgical Procedures/standards , Digestive System Surgical Procedures/trends , Female , Follow-Up Studies , Forecasting , Humans , Laparoscopy/trends , Male , Minimally Invasive Surgical Procedures/trends , Risk Assessment , Surgery, Computer-Assisted/standards , Surgery, Computer-Assisted/trends
10.
Semin Laparosc Surg ; 11(3): 201-9, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15510316

ABSTRACT

Traditional monopolar and bipolar electrosurgery remain very useful in laparoscopic surgery. The need for meticulous hemostasis and the tedium of vessel ligation in advanced cases has propelled the development of new energy source devices that have proved to be remarkably helpful in both laparoscopic and open surgery. Energy sources in the form of argon beam coagulation, ultrasonic coagulation, and bipolar vessel sealing systems have revolutionized laparoscopic surgery. Although each of these energy sources has improved the efficiency and safety of minimally invasive techniques, they can also be associated with distressing complications. This report describes the biophysics of these tools, their spectrum of effectiveness, and methods of application that may improve our ability to perform surgery in a safe and proficient manner.


Subject(s)
Electric Power Supplies , Electrosurgery , Laparoscopy , Argon , Electrocoagulation , Humans , Pacemaker, Artificial , Ultrasonic Therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...