Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 76
Filter
1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38767127

ABSTRACT

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Subject(s)
Cryosurgery , Pulmonary Veins , Cryosurgery/methods , Cryosurgery/instrumentation , Cryosurgery/adverse effects , Animals , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Swine , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Humans , Models, Cardiovascular , Muscle, Skeletal/surgery , Models, Anatomic
2.
J Cardiol ; 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38641319

ABSTRACT

BACKGROUND: The relationship between baseline yellow plaque (YP) and vascular response after stent implantation has not been fully investigated. METHODS: This was a sub-analysis of the Collaboration-1 study (multicenter, retrospective, observational study). A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention were analyzed. Optical coherence tomography (OCT) and coronary angioscopy (CAS) were serially performed immediately and 11 months after stent implantation. YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS. Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT. OCT and CAS findings at 11 months were compared between lesions with baseline YP (YP group) and lesions without baseline YP (Non-YP group). RESULTS: Baseline YP was detected in 37 lesions (42 %). OCT findings at 11 months showed that the incidence of neoatherosclerosis was significantly higher in the YP group (11 % versus 0 %, p = 0.028) and mean neointimal thickness tended to be lower (104 ±â€¯43 µm versus 120 ±â€¯48 µm, p = 0.098). CAS findings at 11 months demonstrated that the dominant and minimum neointimal coverage grades were significantly lower (p = 0.049 and P = 0.026) and maximum yellow color grade was significantly higher (p < 0.001) in the YP group. CONCLUSIONS: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11 months after stent implantation.

3.
Am J Cardiol ; 218: 43-50, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38479607

ABSTRACT

Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities. We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation. This observational study included 100 consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%). Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the RHYTHMIA mapping system (Boston Scientific, Marlborough [Cambridge] Massachusetts). Patients were followed for 2 years. AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5 cm2; hazard ratio [HR] = 2.53; 95% confidence interval [CI] = 1.30 to 4.93; p <0.006), fractionated-electrogram areas (≥5 peaks, >5 cm2; HR = 2.15, 95% CI = 1.10 to 4.19; p = 0.025), LA conduction time of >130 ms (HR = 3.11, 95% CI = 1.65 to 5.88, p <0.0001), deceleration zone (≥5 isochrones/cm2; HR = 1.97, 95% CI = 1.04 to 3.37, p = 0.039), and multiple septal break-out points (HR = 3.27, 95% CI = 1.50 to 7.16, p = 0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR = 1.90, 95% CI = 1.44 to 2.52, p <0.00001 for each additional risk factor. In conclusion, a high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Heart Atria , Heart Rate , Risk Factors , Catheter Ablation/adverse effects , Recurrence , Treatment Outcome
4.
J Vasc Surg Cases Innov Tech ; 10(3): 101447, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38510091

ABSTRACT

A fluoropolymer-based drug-eluting stent was implanted in an arteriovenous graft outflow venous stenosis. Two and a half years later, due to a local infection, the stent was removed surgically, and a pathological evaluation was conducted. The stent struts exhibited partial endothelial cell coverage, with the remaining surface predominantly covered by fibrin. Notably, there was no evidence of restenosis or aneurysmal change.

5.
J Cardiovasc Electrophysiol ; 35(4): 775-784, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38375957

ABSTRACT

INTRODUCTION: Left atrial low-voltage areas (LVAs) are known to be correlated with atrial scarring and atrial fibrillation (AF) recurrence after ablation. However, the association between LVAs and glycemic status before ablation has not been fully clarified. The purpose of this study was to investigate associations among the prevalence of diabetes mellitus (DM), glycemic control, and the prevalence of LVAs in patients with AF ablation. METHODS: In total, 912 (age, 68 ± 10 years; female, 299 [33%]; persistent AF, 513 [56%]) consecutive patients who underwent initial AF ablation were included. A preprocedure glycated hemoglobin A1c (HbA1c) ≥7% was set as the cutoff for poor glycemic control in patients with DM. LVAs were defined as areas with a bipolar voltage of <0.5 mV covering ≥5 cm2 of left atrium. RESULTS: LVAs existed in 208 (23%) patients, and 168 (18%) patients had DM. LVAs were found more frequently in patients with DM and poor glycemic control. On multivariate analysis, DM with HbA1c ≥7% was an independent predictor of LVAs (odds ratio, 3.3; 95% confidence interval: 1.6-6.7; p = .001). In patients with LVAs, freedom from AF recurrence during the 24-month study period was significantly lower in patients who had DM with HbA1c ≥7% than in those without DM (37.9% vs. 54.7%, p = .02). CONCLUSION: In patients with AF ablation, LVAs were found more frequently in patients with DM and poor glycemic control. DM with HbA1c ≥7% was an independent predictor of LVAs.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Diabetes Mellitus , Humans , Female , Middle Aged , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Prevalence , Glycated Hemoglobin , Glycemic Control , Heart Atria/surgery , Diabetes Mellitus/diagnosis , Diabetes Mellitus/epidemiology , Diabetes Mellitus/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence , Treatment Outcome
6.
J Vasc Interv Radiol ; 35(2): 259-268, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37898458

ABSTRACT

PURPOSE: To investigate the impact of compliance with recommended procedural techniques on the midterm patency of a fluoropolymer-based drug-eluting stent (FP-DES) in the femoropopliteal artery. MATERIALS AND METHODS: This retrospective study included 200 femoropopliteal lesions (chronic limb-threatening ischemia, 59%; chronic total occlusion, 41%) in 173 patients (male, 66%; diabetes mellitus, 62%; hemodialysis, 40%) with lower extremity arterial disease who underwent intravascular ultrasound (IVUS)-guided endovascular therapy with FP-DES between January 2016 and July 2021. The primary outcome measure was restenosis, defined as a peak systolic velocity ratio of >2.4 based on the duplex US findings. The association between procedural techniques and incidence of restenosis was investigated using Cox proportional hazards regression models. RESULTS: The 2-year cumulative incidence of restenosis was 19.5% (SD ± 3.3). Multivariate analysis revealed that noncompliance with recommended procedural techniques, such as plaque burden at the stent edge of <50%, a minimum stent area (MSA) of >12 mm2, and stent placement within the P1 segment, was independently associated with an increased risk of restenosis (hazard ratios [HRs], 3.22, 4.71, and 4.67 and P = .004, P < .001, and P < .001, respectively). The 2-year restenosis risk for procedures performed in compliance with all 3-technical criteria was 8.4% (SD ± 3.4), whereas the risks for those in compliance with 2-technical criteria or 0- or 1-technical criteria were 25.0% (SD ± 6.2) and 48.6% (SD ± 10.4), respectively. HRs relative to 3-technical criteria compliance were 3.79 (P = .007) and 11.85 (P < .001), respectively. CONCLUSIONS: Noncompliance with recommended procedural techniques, including plaque burden at the stent edge of <50%, MSA of >12 mm2, and stent placement within the P1 segment, was significantly associated with an increased risk of 2-year restenosis after FP-DES implantation in the femoropopliteal artery.


Subject(s)
Drug-Eluting Stents , Peripheral Arterial Disease , Humans , Male , Femoral Artery/diagnostic imaging , Popliteal Artery/diagnostic imaging , Fluorocarbon Polymers , Retrospective Studies , Treatment Outcome , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Vascular Patency , Prosthesis Design
8.
J Cardiovasc Electrophysiol ; 35(1): 171-181, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38018401

ABSTRACT

INTRODUCTION: Atrial fibrillation (AF) is accompanied by various types of remodeling, including volumetric enlargement and histological degeneration. Electrical remodeling reportedly reflects histological degeneration. PURPOSE: To clarify the differences in determinants and clinical impacts among types of remodeling. METHODS: This observational study included 1118 consecutive patients undergoing initial ablation for AF. Patients were divided into four groups: minimal remodeling (left atrial volume index [LAVI] < mean value and no low-voltage area [LVA], n = 477); volumetric remodeling (LAVI ≥ mean value and no LVA, n = 361); electrical remodeling (LAVI < mean value and LVA presence, n = 96); and combined remodeling (LAVI ≥ mean value and LVA presence, n = 184). AF recurrence and other clinical outcomes were followed up for 2 and 5 years, respectively. RESULTS: Major determinants of each remodeling pattern were high age for electrical (odds ratio = 2.32, 95% confidence interval = 1.68-3.25) and combined remodeling (2.57, 1.88-3.49); female for electrical (3.85, 2.21-6.71) and combined remodeling (4.92, 2.90-8.25); persistent AF for combined remodeling (7.09, 3.75-13.4); and heart failure for volumetric (1.71, 1.51-2.53) and combined remodeling (2.21, 1.30-3.75). Recurrence rate after initial ablation increased in the order of minimal remodeling (20.1%), volumetric (27.4%) or electrical remodeling (36.5%), and combined remodeling (50.0%, p < .0001). A composite endpoint of heart failure, stroke, and death occurred in the order of minimal (3.4%), volumetric (7.5%) or electrical (8.3%), and combined remodeling (15.2%, p < .0001). CONCLUSION: Volumetric, electrical, and combined remodeling were each associated with a unique patient background, and defined rhythm and other clinical outcomes.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Remodeling , Heart Failure , Female , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Recurrence , Treatment Outcome , Male
9.
Pacing Clin Electrophysiol ; 47(1): 28-35, 2024 01.
Article in English | MEDLINE | ID: mdl-38029377

ABSTRACT

BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Electrophysiologic Techniques, Cardiac , Catheter Ablation/methods , Atrial Fibrillation/surgery , Heart Atria , Catheters
10.
Heart Rhythm ; 21(4): 378-386, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38157922

ABSTRACT

BACKGROUND: Atrial cardiomyopathy is known as an underlying pathophysiological factor in the majority of patients with atrial fibrillation (AF). Left atrial low-voltage areas (LVAs) are reported to coincide with fibrosis and likely represent atrial cardiomyopathy. OBJECTIVE: The purpose of this study was to delineate differences in the long-term prognosis of patients stratified by the size of LVAs. METHODS: This observational study included 1488 consecutive patients undergoing initial ablation for AF. LVAs were defined as regions with a bipolar peak-to-peak voltage <0.50 mV. The total study population was divided into 3 groups stratified by LVA size: patients with no LVAs (n = 1136); those with small (<20 cm2) LVAs (n = 250) LVAs; and those with extensive (≥20 cm2) LVAs (n = 102). Composite endpoints of death, heart failure, and stroke were followed for up to 5 years. RESULTS: Composite endpoints developed in 105 of 1488 patients (7.1%), and AF recurrence occurred in 410 (27.6%). Composite endpoints developed more frequently in the order of patients with extensive LVAs (19.1%), small LVAs (10.8%), and no LVAs (5.1%) (P for trend <.0001). Multivariable analysis revealed that LVA presence was independently associated with higher incidence of composite endpoints, irrespective of AF recurrence (modified hazard ratio 1.73; 95% confidence interval 1.13-2.64; P = .011) CONCLUSION: LVA presence and its extent both were associated with poor long-term composite endpoints of death, heart failure, and stroke, irrespective of AF recurrence or other confounders. Underlying atrial cardiomyopathy seems to define a poor prognosis after AF ablation.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Catheter Ablation , Heart Failure , Stroke , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Prognosis , Follow-Up Studies , Heart Atria , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Catheter Ablation/adverse effects , Recurrence
11.
Int J Cardiol ; 399: 131686, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38151161

ABSTRACT

BACKGROUND: There are little clinical data on imaging-guided percutaneous coronary intervention (PCI) 1 year after the biodegradable-polymer sirolimus-eluting stents (BP-SES) implantation, when the polymer disappears. METHODS: We retrospectively analyzed 2455 patients who underwent successful PCI with BP-SES or durable-polymer everolimus-eluting stents (DP-EES) between September 2011 and March 2021, and compared 2-year clinical outcomes of BP-SES (n = 459) with DP-EES (n = 1996). The outcome measures were target lesion revascularization (TLR) and major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction, target vessel revascularization, and stent thrombosis. Multivariate analysis using the Cox proportional hazard model and inverse probability weighting (IPW) analysis based on the propensity score were used to evaluate the clinical outcomes. RESULTS: The 2-year cumulative incidences of TLR (BP-SES: 4.9% vs. DP-SES: 6.1%, p = 0.304) and MACE (10.3% vs. 12.5%, p = 0.159) were similar between the two groups. Multivariable and IPW analysis revealed the risks of TLR (p = 0.388 and p = 0.500) and MACE (p = 0.139 and p = 0.083) also had no significant difference. There was a significant interaction between none/mild and moderate/severe calcification with respect to MACE and TLR (adjusted p for interaction = 0.036 and 0.047, respectively). The risk of MACE was significantly lower in BP-SES than in DP-EES in lesions with none/mild calcification (adjusted hazard ratio [aHR]: 0.53; 95% confidence interval [CI]: 0.30-0.91), while it was similar in those with moderate/severe calcification (aHR: 0.95; 95% CI: 0.58-1.55). CONCLUSIONS: Compared with DP-EES, BP-SES demonstrated durable 2-year clinical outcomes. However, BP-SES showed better clinical performance than DP-EES for lesions with none/mild calcification.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Sirolimus/pharmacology , Percutaneous Coronary Intervention/adverse effects , Retrospective Studies , Treatment Outcome , Everolimus , Polymers , Absorbable Implants , Prosthesis Design , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery
13.
Catheter Cardiovasc Interv ; 102(6): 1114-1121, 2023 11.
Article in English | MEDLINE | ID: mdl-37855184

ABSTRACT

AIM: The aim of the current study sought to investigate the angiographic patterns of restenosis after drug-coated balloon (DCB) angioplasty for femoropopliteal (FP) lesions and which repeat endovascular therapy (EVT) for DCB restenosis would provide more freedom from recurrent restenosis. METHODS: This retrospective multicenter study included 119 limbs (chronic limb-threatening ischemia [CLTI]: 55%, lesion length: 136.9 ± 89.6 mm, chronic total occlusion: 25%) of 95 patients (diabetes mellitus: 70%, hemodialysis: 56%) who were diagnosed with DCB restenosis between January 2018 and December 2019. The cases were classified into three groups based on angiographic patterns of restenosis: Class I: focal lesions ≤50 mm, Class II: diffuse lesions >50 mm, and Class III: totally occluded lesions. The DCB restenosis patterns and frequency and predictors of recurrent restenosis after repeated EVT (re-EVT) were investigated. RESULTS: The mean follow-up duration was 29.8 ± 9.5 months. Groups I, II, and III comprised of 30 (25.2%), 55 (46.2%), and 34 (29.0%) cases, respectively. The overall rate of 1-year freedom from recurrent restenosis was 58.2%. One-year rate of freedom from recurrent restenosis after repeat DCB was not statistically different from that after scaffolding (71.1% vs. 74.6%, respectively, p = 0.911); however, it was significantly better than that after noncoated balloon angioplasty (repeat DCB vs. noncoated balloon angioplasty: 71.1% vs. 25.7%, respectively, p < 0.001). Multivariate analysis demonstrated that CLTI (hazard ratio [HR]: 5.15, p < 0.001) and re-EVT with noncoated balloon (HR: 3.16, p < 0.001) were significantly associated with recurrent restenosis; however, Class III pattern of DCB restenosis was not associated with recurrent restenosis (HR: 1.04, p = 0.918). CONCLUSIONS: This study revealed the angiographic patterns of restenosis after DCB therapy for FP lesions and the 1-year rate of recurrent restenosis after repeat revascularization. Repeat DCB therapy demonstrated acceptable 1-year recurrent restenosis rates.


Subject(s)
Angioplasty, Balloon , Endovascular Procedures , Peripheral Arterial Disease , Humans , Popliteal Artery/diagnostic imaging , Treatment Outcome , Femoral Artery/diagnostic imaging , Angioplasty, Balloon/adverse effects , Prognosis , Coated Materials, Biocompatible , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Vascular Patency
14.
Angiology ; : 33197231195671, 2023 Aug 24.
Article in English | MEDLINE | ID: mdl-37615068

ABSTRACT

Cholesterol crystal embolism (CCE) accompanied by a lower extremity wound is occasionally difficult to differentiate from chronic limb-threatening ischemia (CLTI) and treat. The present multi-center retrospective observational study investigated the clinical characteristics and prognosis of CCE with lower extremity wounds. Consecutive patients (n = 58) clinically diagnosed as CCE with lower extremity wounds between April 2010 and December 2019 were studied. CCE was diagnosed using histological findings, foot condition, renal impairment, and eosinophilia. The primary outcome was 1-year wound healing rate. Patients with CCE were compared with 1309 patients diagnosed with CLTI with tissue loss during the same study period. The CCE group had a significantly more severe Wound, Ischemia, and foot Infection (WIfI) classification compared with the CLTI group. After Kaplan-Meier analysis, the CCE group had a similar 1-year wound healing (55.1 vs 58.3%, P = .096) as the CLTI group. In multivariate stratified Cox regression analysis by WIfI stages, CCE was significantly associated with poor wound healing compared with CLTI [hazard ratio .36 (95% confidence interval .21-.62)]. In conclusion, among the similar WIfI clinical stages, wound healing was significantly worse in the CCE group than in the CLTI group.

15.
J Endovasc Ther ; : 15266028231186717, 2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37477010

ABSTRACT

PURPOSE: Clinical trials have demonstrated the superiority of drug-coated balloon (DCB) to noncoated balloon angioplasty for the treatment of femoropopliteal (FP) lesions. In those trials, the difference of primary patency between DCB and noncoated angioplasty widens especially after 6 months, speculating that the antirestenosis effect of paclitaxel is manifested after 6 months. Factors associated with restenosis after 6 months differ from those associated with restenosis within 6 months. This study aimed to elucidate the prognostic factors associated with early (within 6 months) and late (after 6 months) restenosis following DCB treatment in real-world FP practice. MATERIALS AND METHODS: This multicenter, retrospective study analyzed 486 FP lesions (mean lesion length, 11.9±10.1 cm; chronic total occlusion, 21.0%) in 423 patients (diabetes mellitus, 59.3%; hemodialysis, 37.1%; chronic limb-threatening ischemia, 41.6%) who underwent successful DCB treatment between January 2018 and December 2019. The outcome measure was restenosis which is defined as a peak systolic velocity ratio >2.4 based on duplex ultrasound findings. Early and late restenosis were classified by the cutoff period of 6 months after the procedure. The associations of baseline and procedural characteristics with early and late restenosis were explored using Cox proportional hazards regression analysis. RESULTS: The mean follow-up period was 25.3±12.1 months. The 6, 12, 18, and 24 month cumulative incidences of restenosis were 7.4%±2.4%, 20.9%±3.9%, 29.9%±4.5%, and 38.4%±5.1%, respectively. During the follow-up period, early and late restenosis was evident in a total of 31 lesions and 138 lesions, respectively. Multivariate analysis revealed that chronic total occlusion (hazard ratio [HR], 2.29; 95% confidence interval [CI], 1.07-4.92; p=0.033) and superficial femoral artery ostial lesion (HR, 2.73; 95% CI, 1.28-5.80; p=0.009) were significantly associated with early restenosis. On the other hand, calcification circumference over 270° (HR, 1.67; 95% CI, 1.17-2.37; p=0.004), distal external elastic membrane diameter under 5 mm assessed by intravascular ultrasound (HR, 1.90; 95% CI, 1.29-2.79; p=0.001), and involving popliteal arterial lesion (HR, 1.54; 95% CI, 1.08-2.21; p=0.017) were significantly associated with late restenosis. CONCLUSION: The prognostic factors associated with late restenosis differed from those associated with early restenosis in the real-world FP-DCB practice. CLINICAL IMPACT: The current multicenter, retrospective study revealed that factors associated with early restenosis differed from those with late restenosis in the real-world FP-DCB practice. CTO and SFA ostial lesion were associated with early restenosis, while severe calcification, smaller vessel, and involving popliteal arterial lesions were associated with late restenosis.Early restenosis indicates "balloon failure" and would potentially result from recoil, which primary stent implantation might be required. On the other hand, late restenosis after 6 months would be attributed to "DCB failure", with inadequate drug uptake into the arterial wall, which might be minimized by the use of atherectomy devices.

16.
Am J Cardiol ; 203: 37-44, 2023 09 15.
Article in English | MEDLINE | ID: mdl-37481810

ABSTRACT

Atrial myocardial degeneration predisposes to atrial fibrillation (AF), ischemic stroke, and heart failure. Studies suggest the presence of gender differences in atrial myocardial degeneration. This study aimed to delineate gender differences in the prevalence, predictors, and prognostic impact of left atrial low-voltage areas (LVAs). This observational study included 1,488 consecutive patients who underwent initial ablation for AF. Voltage mapping was performed after pulmonary vein isolation during sinus rhythm. LVAs were defined as regions where bipolar peak-to-peak voltage was <0.50 mV. LVA prevalence was higher in women (38.7%) than in men (16.0%). High age, persistent form of AF, diabetes mellitus, and a large left atrium were shown to be common predictors in both gender categories. Heart failure and history of stroke/thromboembolic events were men-specific predictors of LVA existence. Women experienced more AF recurrence than men (31.1% vs 25.7%, p = 0.027). LVA existence was significantly associated with increased AF recurrence in each gender category, with a respective hazard ratio, 95% confidence interval, and p value of 2.45, 1.87 to 3.22, and <0.0001 in men and 1.82, 1.33 to 2.49, and <0.0001 in women. In conclusion, LVA was more frequent in women than men, and predicted frequent AF recurrence irrespective of gender category.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Catheter Ablation , Heart Failure , Pulmonary Veins , Male , Humans , Female , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Sex Factors , Heart Atria , Fibrosis , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
17.
Heart Vessels ; 38(10): 1288-1297, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37247091

ABSTRACT

Clinical trials have demonstrated the efficacy of a balloon-expandable covered stent (CS) for aortoiliac occlusive disease (AIOD). However, the real-world clinical outcomes and the underlying factors remain unclear. We assessed the clinical outcomes and factors associated with primary patency after implantation of a balloon-expandable CS for patients with complex AIOD. This prospective multicenter observational study enrolled 149 consecutive patients undergoing VIABAHN® VBX-CS (W.L. Gore & Associates, Flagstaff, AZ) implantation for complex AIOD (age, 74 ± 9 years; male, 74%; diabetes mellitus, 46%; renal failure on dialysis, 23%; chronic limb-threatening ischemia, 26%). The primary study endpoint was 1-year primary patency, and the secondary endpoints were procedural complications, freedom from occlusion, clinical-driven target lesion revascularization (CD-TLR), and surgical revision at 1 year. Risk factors for restenosis were explored using random survival forest analysis. The median follow-up period was 13.1 months (interquartile range 9.7-14.0 months). Procedural complications were observed in 6.7% of the patients. The 1-year primary patency was 94.8% (95% confidence interval 91.0-98.6%), while the 1-year freedom rate from occlusion, CD-TLR, and surgical revision rates were 96.5% (93.5-99.5%), 94.7% (90.9-98.6%), and 97.8% (95.4-100%), respectively. The presence of chronic total occlusion, aortic bifurcation lesion, the number of disease regions, and TASC-II classification was significantly associated with the restenosis risk. In contrast, the calcification severity, IVUS use, IVUS parameters were not associated with restenosis risk. We observed excellent 1-year real-world outcomes after implantation of a balloon-expandable CS for complex AIOD; only a few perioperative complications occurred.


Subject(s)
Atherosclerosis , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Persea , Humans , Male , Aged , Aged, 80 and over , Prospective Studies , Treatment Outcome , Vascular Patency , Stents , Blood Vessel Prosthesis Implantation/adverse effects , Atherosclerosis/etiology , Femoral Artery , Endovascular Procedures/adverse effects , Prosthesis Design , Retrospective Studies
18.
J Cardiovasc Med (Hagerstown) ; 24(8): 544-551, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37161971

ABSTRACT

AIMS: Atrial natriuretic peptide (ANP) deficiency is thought to be one of the causes of heart failure induced by atrial fibrillation (AF). Although ANP deficiency is thought to occur as a result of atrial remodeling, data to explain this mechanism are limited. The purpose of this study was to investigate the association between ANP and left atrial remodeling or prognosis of heart failure in patients with AF ablation. METHODS: In total, 373 consecutive patients who underwent initial ablation for persistent AF [age, 67 ±â€Š10 years; female, 97 (26%)] were retrospectively enrolled. ANP and brain natriuretic peptide (BNP) were measured before the procedure and the ANP/BNP ratio was calculated. Left atrial volume index, left atrial appendage emptying velocity, and left atrial low-voltage areas (LVAs) were used as left atrial-remodeling parameters. The primary outcome of heart failure was defined as the composite of all-cause death or hospitalization due to worsening heart failure. RESULTS: The median ANP level was 116 (71-178) pg/ml and the median ANP/BNP ratio was 0.65 (0.46-1.00). The ANP/BNP ratio decreased with increasing left atrial volume index or LVAs and with decreasing left atrial appendage emptying velocity. During the 5-year follow-up, freedom from the primary outcome was significantly lower in patients with ANP/BNP ratio ≤0.65 than in those with ANP/BNP ratio >0.65 (84.6% versus 95.6%, P  < 0.01). CONCLUSION: Secretion of ANP relative to BNP decreased with progression of left atrial remodeling in patients with AF ablation. Furthermore, prognosis of heart failure was poor in patients with a low ANP/BNP ratio.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Heart Failure , Aged , Female , Humans , Middle Aged , Atrial Natriuretic Factor , Heart Failure/etiology , Natriuretic Peptide, Brain , Retrospective Studies , Male
19.
Circ J ; 87(3): 432-429, 2023 02 24.
Article in English | MEDLINE | ID: mdl-36624062

ABSTRACT

BACKGROUND: Although favorable clinical outcomes have been demonstrated for fluoropolymer-based paclitaxel-eluting stents (FP-DES) in the treatment of femoropopliteal lesions, the vascular response after implantation has not been systematically studied through intravascular imaging.Methods and Results: We angioscopically compared FP-DES: 24 in the early phase (mean [±SD] 3±1 months), 26 in the middle phase (12±3 months), and 20 in the late phase (≥18 months) after implantation. The dominant neointimal coverage grade, heterogeneity of neointimal coverage grade, and thrombus adhesion in the stent segment were evaluated. Neointimal coverage was graded as follows: Grade 0, stent struts exposed; Grade 1, struts bulging into the lumen, although covered; Grade 2, struts embedded in the neointima, but visible; Grade 3, struts fully embedded and invisible. Dominant neointimal coverage and heterogeneity grades were significantly higher in the middle and late phases than in the early phase (all P<0.05), but did not differ significantly between the middle and late phases. The incidence of thrombus adhesion was recorded for all stents in each of the 3 different phases. CONCLUSIONS: The middle and late phases after FP-DES implantation were associated with significantly higher dominant neointimal coverage and heterogeneity grades than the early phase. However, thrombus adhesion was observed in all phases after FP-DES implantation. Arterial healing may not be completed even in the late phase after FP-DES implantation.


Subject(s)
Drug-Eluting Stents , Thrombosis , Humans , Fluorocarbon Polymers , Angioscopy/methods , Femoral Artery , Neointima/pathology , Thrombosis/pathology , Coronary Vessels/pathology , Treatment Outcome
20.
J Endovasc Ther ; 30(1): 75-83, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35057659

ABSTRACT

PURPOSE: The current study sought to investigate the impact of cardiac condition on loss of patency after endovascular therapy (EVT) using new-generation devices for femoropopliteal (FP) lesions. MATERIALS AND METHODS: We retrospectively studied 547 lesions (chronic limb-threatening ischemia: 44%, TASC II C/D lesion: 61%, chronic total occlusion: 37%, in-stent restenosis: 13%, involving popliteal arterial lesion: 45%) belonging to 416 patients (average age: 75±9 years, male: 69%, diabetes mellitus: 62%, hemodialysis: 33%) who underwent EVT with new-generation FP-specific devices (polymer-free paclitaxel-eluting stent, n=186; stent graft, n=119; fluoropolymer-based paclitaxel-eluting stent, n=29; interwoven stent, n=17; drug-coated balloon, n=196) from June 2012 to May 2019. Cardiac function was evaluated using echocardiography. The primary outcome measure was primary patency, which was defined as free from peak systolic velocity ratio (PSVR) >2.5 assessed by duplex ultrasound. Predictors for loss of patency were evaluated using Cox proportional hazards regression analysis. RESULTS: Overall 12 primary patency were 80.0±1.8%. After the multivariate analysis, reduced stroke volume evaluated by echocardiography (hazard ratio [HR]=0.99, 95% confidence interval [CI]=0.97-0.99, p=0.03), chronic heart failure (HR=1.76, 95% CI=1.05-2.97, p=0.03), and a smaller distal reference vessel diameter (HR=0.73, 95% CI=0.55-0.97, p=0.03) were significantly associated with loss of 12-month primary patency, whereas lesion length (HR=1.01, 95% CI=0.99-1.03, p=0.33) and presence of chronic total occlusion (CTO; HR=0.92, 95% CI=0.61-1.40, p=0.70) were not statistically significant. CONCLUSION: The current study revealed that cardiac function represented by reduced stroke volume and presence of chronic heart failure as well as a smaller distal reference vessel diameter were significantly associated with loss of 12-month primary patency in patients with peripheral artery disease (PAD) presenting FP lesions endovascularly treated with new-generation devices.


Subject(s)
Drug-Eluting Stents , Heart Failure , Peripheral Arterial Disease , Humans , Male , Aged , Aged, 80 and over , Popliteal Artery , Retrospective Studies , Treatment Outcome , Vascular Patency , Risk Factors , Femoral Artery , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Peripheral Arterial Disease/pathology , Heart Failure/pathology , Paclitaxel/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...