Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
BMC Cardiovasc Disord ; 19(1): 302, 2019 12 19.
Article in English | MEDLINE | ID: mdl-31881943

ABSTRACT

BACKGROUND: Endomyocardial fibrosis (EMF) represents the most common cause of restrictive cardiomyopathy worldwide. Despite a high prevalence in tropical regions, it occasionally occurs in patients who have never visited these areas. While researches have proposed various possible triggers for EMF, etiology and pathogenesis remain largely unknown. Diagnosis is based on patient history, heart failure symptoms, and echocardiographic signs of restrictive ventricular filling, atrioventricular valve regurgitation and frequently apical thrombus. Following is a case report of an Austrian patient with EMF who eventually had to undergo a heart transplant. This case report strives to promote awareness for this in non-tropical areas uncommon but nevertheless detrimental disease. CASE PRESENTATION: A 40-year-old woman was presented at our emergency department with chest pain and fever up to 38.1° Celsius. Plasma troponin-T levels and inflammatory markers were slightly elevated, but the echocardiogram was without pathological findings. The patient was hospitalized on the suspicion of acute myocarditis and discharged soon after improvement. Eight months later, she was presented again with chest pain and symptoms of heart failure. The echocardiogram showed normal systolic left ventricular (LV) function with LV wall thickening and severe restrictive mitral regurgitation as well as aortic and tricuspid regurgitation. Coronary angiogram was normal but right heart catheterization showed pulmonary hypertension due to left heart disease. Further diagnostic workup with cardiac magnetic resonance imaging revealed subendocardial late enhancement and apical thrombus formation in the left ventricle compatible with the diagnosis of EMF. A comprehensive diagnostic workup showed no evidence of infection, systemic immunologic or hematological disease, in particular hypereosinophilic syndrome. After a multidisciplinary consideration of several therapeutic options, the patient was listed for heart transplantation. On the waiting list, she deteriorated rapidly due to progressive heart failure and finally underwent a heart transplantation. Histological examination confirmed the diagnosis of EMF. Six years after her heart transplantation, the patient was presented in an excellent clinical condition. CONCLUSIONS: Even in non-tropical regions, the diagnosis of EMF should always be considered in restrictive cardiomyopathy. Knowledge of the distinct phenotype of EMF facilitates diagnosis, but comprehensive workup and therapeutic management remain challenging and require a multidisciplinary approach.


Subject(s)
Endomyocardial Fibrosis/surgery , Heart Failure/surgery , Heart Transplantation , Myocardium/pathology , Adult , Austria , Disease Progression , Endomyocardial Fibrosis/diagnostic imaging , Endomyocardial Fibrosis/pathology , Endomyocardial Fibrosis/physiopathology , Female , Heart Failure/diagnostic imaging , Heart Failure/pathology , Heart Failure/physiopathology , Humans , Recovery of Function , Time Factors , Treatment Outcome , Waiting Lists
2.
Wien Klin Wochenschr ; 129(13-14): 487-490, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28597323

ABSTRACT

BACKGROUND: We hypothesize that stenting of the internal carotid artery can immediately impede blood flow to the external carotid artery by either plaque shift or stent coverage of the ostium, and thereby cause ischemic symptoms like ipsilateral jaw claudication. METHODS: Thirty-three patients with high-grade asymptomatic stenosis of the internal carotid artery who underwent endovascular treatment were examined by ultrasound of the external carotid artery and performed an exercise test by chewing chewing gum synchronously to an electronic metronome for 3 min. Tests were performed before, the day after, and 1 week after the stenting procedure. Claudication time was defined as the timespan until occurrence of pain of the masseter muscle and/or chewing dyssynchrony to the metronome for more than 15 s. Ten patients with an isolated, atherosclerotic stenosis of the external carotid artery served as controls. RESULTS: A significantly reduced claudication time (in seconds) was recorded in patients who underwent carotid artery stenting compared to baseline values; median 89 (interquartile range, IQR, 57 to 124) vs. median 180 (IQR 153 to 180; p < 0.001). By categorization of the flow velocity at the external carotid artery into faster or slower as 200 cm/sec, the effect was even accentuated. Stenting values showed improvement 1 week after but did not return to baseline levels. No respective changes were found in controls. CONCLUSION: Stenting of the internal carotid artery lead to ipsilateral flow deterioration at the external carotid artery resulting in temporary jaw claudication. This impairment attenuated over the time and was significantly reduced after 1 week.


Subject(s)
Carotid Artery, External , Carotid Stenosis/complications , Carotid Stenosis/therapy , Ischemia/etiology , Jaw/blood supply , Stents/adverse effects , Aged , Cohort Studies , Female , Humans , Male , Mastication/physiology , Middle Aged , Prospective Studies , Risk Factors , Ultrasonography, Doppler, Color
3.
Stroke ; 42(7): 1826-33, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21546482

ABSTRACT

BACKGROUND AND PURPOSE: Atherosclerosis is a chronic inflammatory disease. Ongoing inflammation is associated with elevated levels of beta 2 microglobulin (B2M). We investigated B2M levels in a large cohort of patients with carotid atherosclerosis for the occurrence of major adverse cardiovascular events. METHODS: One thousand five of 1286 consecutive, neurologically asymptomatic patients with carotid atherosclerosis were followed for a median of 3 years (interquartile range, 2.5 to 3.5) for the occurrence of major adverse cardiovascular events, a composite of myocardial infarction, percutaneous coronary intervention, coronary bypass graft, stroke, and death. RESULTS: We recorded 359 major cardiovascular events in 271 (27%) patients. B2M was significantly associated with the occurrence of major adverse cardiovascular events. With increasing quartiles of B2M, the adjusted hazard ratios were 1.19 (95% CI, 0.81 to 1.73), 1.51 (95% CI, 1.05 to 2.18), and 1.88 (95% CI, 1.26 to 2.79) compared with the lowest quartile, respectively (P<0.001). Adjusted hazard ratios for the occurrence of death, myocardial infarction, and stroke for increasing quartiles of B2M were 1.25 (95% CI, 0.92 to 1.70), 1.52 (95% CI, 1.12 to 2.06), and 1.62 (95% CI, 1.16 to 2.67) compared with the lowest quartile, respectively (P<0.001). Through statistical estimation of improvement in risk stratification, addition of B2M to baseline risk factors improved the risk stratification for major cardiovascular events, at least as much as high-sensitivity C-reactive protein or even better. CONCLUSIONS: B2M was independently and significantly associated with adverse cardiovascular outcome in patients with prevalent asymptomatic carotid atherosclerosis.


Subject(s)
Cardiovascular Diseases/complications , Carotid Artery Diseases/complications , Plaque, Atherosclerotic/complications , beta 2-Microglobulin/biosynthesis , Aged , Biomarkers/metabolism , Cardiovascular Diseases/diagnosis , Carotid Artery Diseases/blood , Cohort Studies , Female , Humans , Hypertension , Inflammation , Male , Middle Aged , Myocardial Infarction/metabolism , Plaque, Atherosclerotic/blood , Proportional Hazards Models
4.
J Vasc Surg ; 52(2): 383-7, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20488641

ABSTRACT

OBJECTIVE: Pseudoaneurysms are characterized by extravascular circulation and therefore may lead to an activation of the coagulation cascade. We investigated d-dimer levels in patients with and without postcatheterization femoral pseudoaneurysms and hypothesized that d-dimer levels correlate with the presence of pseudoaneurysms at the vascular access site. METHODS: Patients with clinical suspected groin pseudoaneurysms after transluminal procedures were eligible. We compared prospectively-collected laboratory values of quantitative d-dimer testing in patients with and without pseudoaneurysms as assessed by color-coded duplex sonography. Furthermore, we measured the peak systolic velocity at the arterial fistula of each pseudoaneurysm. RESULTS: In 48 (40%) of 120 consecutive patients, a pseudoaneurysm was found. The level of d-dimer values was significantly higher in patients with postcatheterization femoral pseudoaneurysms compared with controls (1.9 microg/mL [interquartile range (IQR), 1.34-2.78 microg/mL] vs 0.8 microg/mL [IQR, 0.53-1.14 microg/mL]; P < .001). Values of d-dimer below 0.67 microg/mL have been calculated with a sensitivity of 94% (87%-100%), a specificity of 38% (27%-50%), a positive predictive value of 50% (40%-60%), a negative predictive value of 90% (82%-99%), and a likelihood ratio of 1.52 (1.25-1.85) with regard to the presence of pseudoaneurysms. We also found a significant correlation of the peak systolic velocity at the arterial fistula and increasing d-dimer levels (r = 0.98, P < .0001). CONCLUSION: We found a significantly higher level of d-dimer values in patients with femoral pseudoaneurysms at the vascular access site. Therefore, d-dimer levels could be a potential serological marker in the diagnosis of pseudoaneurysms. A confirmation is warranted in a larger patient sample.


Subject(s)
Aneurysm, False/diagnosis , Angioplasty, Balloon/adverse effects , Femoral Artery , Fibrin Fibrinogen Degradation Products/analysis , Peripheral Vascular Diseases/therapy , Vascular Fistula/diagnosis , Aged , Aneurysm, False/blood , Aneurysm, False/etiology , Aneurysm, False/physiopathology , Biomarkers/blood , Blood Flow Velocity , Case-Control Studies , Chi-Square Distribution , Female , Humans , Logistic Models , Male , Middle Aged , Odds Ratio , Platelet Count , Predictive Value of Tests , Prospective Studies , Regional Blood Flow , Risk Assessment , Risk Factors , Sensitivity and Specificity , Treatment Outcome , Ultrasonography, Doppler, Color , Up-Regulation , Vascular Fistula/blood , Vascular Fistula/etiology , Vascular Fistula/physiopathology
5.
Eur J Radiol ; 76(1): 129-34, 2010 Oct.
Article in English | MEDLINE | ID: mdl-19619969

ABSTRACT

PURPOSE: To evaluate the prevalence of nephrogenic systemic fibrosis (NSF) in a patient population being at highest risk for developing this disease and to evaluate possible risk factors. MATERIALS AND METHODS: The radiological records of 552 patients with ESRD being on hemodialysis (HD) or peritoneal dialysis (PD) were retrospectively reviewed to identify whether the patients underwent MR-examinations with or without intravenous administration of GBCA. In case of exposure to GBCA, the number of contrast injections, the benchmark and the cumulative doses of GBCA, and possible cofactors regarding pathogenesis of NSF were recorded. Diagnosis of NSF was confirmed either by deep skin biopsy or by review of medical and histopathological records. Data of NSF patients were compared with data of dialysis patients who did not develop NSF after MR-examinations. RESULTS: 146 dialysis patients underwent MRI without i.v.-administration of GBCA. No case of NSF was observed in this patient population. 195/552 patients proved to have a total number of 325 well-documented exposures to GBCA. Seven different types of GBCA were used during these MR-examinations. NSF prevalence rate was 1.6%. One patient died of NSF. Three different types of GBCA were involved in 6 NSF cases. 4/6 proved to be confounded cases. The cumulative dose of GBCA, history of thrombosis, recent surgery, and the combination of HD and PD proved to be significant cofactors for the development of NSF (p<.05). No significant difference regarding residual renal clearance (p=.898) and residual urine volume (p=.083) was found between NSF and non-NSF patients. CONCLUSION: The prevalence of NSF proved to be much lower in this high risk patient group being exposed to GBCA compared to the literature. NSF was not observed in ESRD patients undergoing MRI without administration of GBCA. Our data support a positive association between cumulative dose of GBCA and development of NSF. No positive association was found between residual renal clearance and residual urine volume and NSF.


Subject(s)
Contrast Media/adverse effects , Gadolinium/adverse effects , Kidney Failure, Chronic/therapy , Magnetic Resonance Imaging , Nephrogenic Fibrosing Dermopathy/chemically induced , Nephrogenic Fibrosing Dermopathy/epidemiology , Renal Dialysis , Aged , Biopsy , Female , Humans , Injections, Intravenous , Male , Middle Aged , Prevalence , Retrospective Studies , Risk Factors , Statistics, Nonparametric
6.
Atherosclerosis ; 205(1): 314-8, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19152915

ABSTRACT

OBJECTIVES: We hypothesized that high sensitivity C-reactive protein (hs-CRP) and the presence of renal artery stenosis (RAS) might conjointly predict future major adverse cardiovascular events (MACE) in patients with peripheral artery disease (PAD). BACKGROUND: Clinical outcome in PAD is determined by the extent of atherosclerosis affecting additional vascular beds and the activity of the atherosclerotic process reflected by inflammatory serum markers. Data on the predictive value of hs-CRP on outcome in PAD patients with RAS is limited. METHODS: We prospectively enrolled 447 PAD patients who were admitted to our institution for angioplasty. Preintervention hs-CRP was assessed and renal angiograms were obtained. Patients were then followed clinically for the occurrence of MACE for median 15.6 months. Serum creatinine was obtained in all patients at 12 months. RESULTS: Incidental RAS >or=60% at baseline was found in 68 patients (15.2%), MACE were recorded in 111 patients during follow-up. Hs-CRP was significantly associated with the occurrence of MACE (p<0.001) and with 12 months creatinine levels (p=0.005). Adjusted hazard ratios for MACE for increasing quartiles of hs-CRP as compared to the lowest quartile were 1.11 (95% CI 0.53-2.35), 1.06 (95% CI 0.50-2.26) and 2.79 (95% CI 1.47-5.28). Analyzing joint effects of hs-CRP and RAS, we observed no significant interaction. CONCLUSION: Hs-CRP predicts cardiovascular and renal outcome in PAD patients irrespective of the presence of RAS. Patients with hs-CRP levels above 0.88 mg/dL were at particularly high risk for MACE.


Subject(s)
Cardiovascular Diseases/complications , Cardiovascular Diseases/diagnosis , Peripheral Vascular Diseases/complications , Peripheral Vascular Diseases/diagnosis , Renal Artery Obstruction/complications , Renal Artery Obstruction/diagnosis , Aged , Angioplasty , C-Reactive Protein/biosynthesis , Creatinine/blood , Female , Humans , Inflammation , Male , Middle Aged , Prospective Studies , Treatment Outcome
7.
Pediatrics ; 122(6): 1284-91, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19047247

ABSTRACT

OBJECTIVES: Deep venous thrombosis in children is frequently related to central venous lines. Study objectives were to determine objectively the incidence of deep venous thrombosis in children with short-term central venous lines and to assess the diagnostic value of venography, venous ultrasonography, and echocardiography, in a prospective cohort study. METHODS: Consecutive children with congenital heart disease requiring short-term central venous lines in the upper venous system were screened systematically for deep venous thrombosis by using venography, venous ultrasonography, and echocardiography, according to standardized protocols. RESULTS: The study population consisted of 90 children (median age: 2.7 years; range: birth to 18 years). Most central venous lines (97%) were located in the jugular veins. The overall incidence of deep venous thrombosis was 25 cases (28%) among 90 children. Venography identified deep venous thrombosis located in the subclavian and central veins but missed most deep venous thrombosis in the jugular veins. Venous ultrasonography had good sensitivity in the jugular veins but did not detect deep venous thrombosis in central veins. Echocardiography detected only 1 case of central deep venous thrombosis. CONCLUSIONS: The incidence of central venous line-related deep venous thrombosis in children with short-term central venous lines is high and comparable to reports for children with long-term central venous lines. Sensitivities of venography, venous ultrasonography, and echocardiography in children vary depending on the affected venous segment. A combination of diagnostic tests is required for sensitive detection of central venous line-related deep venous thrombosis in the upper venous system.


Subject(s)
Catheterization, Central Venous/adverse effects , Diagnostic Imaging/methods , Venous Thrombosis/diagnosis , Venous Thrombosis/epidemiology , Adolescent , Age Distribution , Catheterization, Central Venous/methods , Child , Child, Preschool , Cohort Studies , Echocardiography, Doppler , Female , Follow-Up Studies , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy , Humans , Incidence , Infant , Infant, Newborn , Jugular Veins , Male , Phlebography , Predictive Value of Tests , Prospective Studies , Risk Assessment , Sensitivity and Specificity , Sex Distribution , Subclavian Vein , Time Factors , Ultrasonography, Doppler , Venous Thrombosis/etiology
8.
Radiology ; 249(3): 1058-63, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18840791

ABSTRACT

PURPOSE: To investigate the safety and efficacy of the procoagulant wound dressing Neptune Pad (Biotronik, Berlin, Germany) compared with those of conventional manual compression for access site management after peripheral percutaneous interventions. MATERIALS AND METHODS: The study was approved by the institutional ethics committee, and all patients gave written informed consent. Two hundred one consecutive patients were enrolled and were randomly assigned to be treated with the Neptune Pad (n = 100) or conventional manual compression (n = 101). Patients were followed up clinically until hospital discharge and with duplex ultrasonography at 24 hours after the procedure to evaluate occurrence of access site complications. Time to hemostasis and time to ambulation were recorded, and patient and physician discomfort were measured by using a visual analogue scale. RESULTS: The risk for access site complications was not significantly different between the Neptune Pad group and the conventional compression group (adjusted odds ratio, 1.15; 95% confidence interval: 0.47, 2.84; P = .76). Time to hemostasis was marginally reduced in the Neptune Pad group. Patient and physician discomfort were lessened with use of the device. CONCLUSION: The hemostatic device Neptune Pad does not improve the safety of access site management after peripheral percutaneous procedures. Markedly improved comfort was noted among patients in the Neptune Pad group and by the physicians obtaining hemostasis.


Subject(s)
Angioplasty, Balloon , Bandages , Hemostatic Techniques/instrumentation , Aged , Aged, 80 and over , Alginates/administration & dosage , Female , Glucuronic Acid/administration & dosage , Hexuronic Acids/administration & dosage , Humans , Male , Patients , Pressure , Vascular Diseases/surgery
9.
Radiology ; 248(1): 297-302, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18566179

ABSTRACT

PURPOSE: To prospectively determine whether cutting balloon angioplasty, when compared with conventional balloon angioplasty (CBA), improves morphologic and clinical outcome in patients with femoropopliteal in-stent restenosis. MATERIALS AND METHODS: Patients with symptomatic femoropopliteal in-stent restenosis were randomly assigned to undergo CBA or peripheral cutting balloon angioplasty (PCBA) for treatment of lesions up to 20 cm in length. Patients were followed up clinically and with duplex ultrasonography (US) at 1, 3, and 6 months for occurrence of a restenosis of 50% or higher. The Fisher exact test and Mann Whitney U test were used for statistical analyses. RESULTS: Forty patients were enrolled; one patient was lost to follow-up. In the remaining patients, CBA was performed in 22 patients; PCBA was used in 17 patients. Average lesion length was 80 mm +/- 68 (standard deviation). Restenosis rates at 6 months were 65% (11 of 17; 95% confidence interval: 42%, 88%) after PCBA versus 73% (16 of 22; 95% confidence interval: 54%, 92%) after CBA (P = .73). Ankle brachial index (0.83 vs 0.75, P = .26) and maximum walking capacity on the treadmill (117 m vs 103 m, P = .97) at 6 months were also not significantly different between the two groups. CONCLUSION: PCBA failed to prove superiority compared with CBA for treatment of femoropopliteal in-stent restenosis in this pilot study. In restenotic lesions with an average length of approximately 8 cm, both treatment modalities yielded disappointing 6-month patency rates.


Subject(s)
Angioplasty, Balloon/methods , Blood Vessel Prosthesis/adverse effects , Femoral Artery/surgery , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/therapy , Popliteal Artery/surgery , Stents/adverse effects , Aged , Female , Humans , Male , Pilot Projects , Treatment Outcome
10.
Radiology ; 247(1): 267-72, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18270378

ABSTRACT

PURPOSE: To prospectively determine, in a randomized controlled trial, whether cutting balloon angioplasty (CBA) yields superior morphologic and clinical outcomes at 6 months compared with the 6-month outcomes after conventional percutaneous transluminal angioplasty (PTA) in patients with short de novo superficial femoropopliteal artery (SFA) lesions. MATERIALS AND METHODS: This study was approved by the ethics committees of the two participating centers, and informed consent was obtained from all patients. The authors randomly assigned 43 patients (26 men, 17 women; median age, 69 years) who had 5 cm or shorter de novo SFA lesions in association with intermittent claudication or chronic limb ischemia to undergo CBA or PTA. The patients were followed up clinically, and restenosis was assessed with duplex ultrasonography (US) at 6 months. chi(2) and Mann-Whitney U tests were used to compare data between the two treatment groups. RESULTS: The US-determined 6-month restenosis rate was 32% (seven patients) in the PTA group versus 62% (13 patients) in the CBA group (P = .048). Sixteen (73%) PTA group patients versus eight (38%) CBA group patients were asymptomatic at follow-up (P = .059). There was no significant difference in ankle-brachial index (median, 0.83 vs 0.77 for PTA vs CBA group, respectively; P = .56) or pain-free walking distance (median, >1000 m vs 600 m for PTA vs CBA group, respectively; P = .17) between the two groups. CONCLUSION: CBA did not prove to be superior to conventional PTA for treatment of short de novo SFA lesions and yielded increased restenosis rates at 6 months.


Subject(s)
Angioplasty, Balloon , Arterial Occlusive Diseases/therapy , Femoral Artery , Popliteal Artery , Aged , Female , Humans , Male , Recurrence
11.
Catheter Cardiovasc Interv ; 71(1): 114-9, 2008 Jan 01.
Article in English | MEDLINE | ID: mdl-18098213

ABSTRACT

OBJECTIVE: To investigate the effect of protected carotid artery stenting on neurocognitive function with particular consideration of the angiographic filling of the ipsilateral anterior cerebral artery (ACA). BACKGROUND: An improved inflow to the supply area of the anterior cerebral artery after revascularisation of severe carotid artery stenosis may beneficially affect frontal lobe cognitive functions. METHODS: We prospectively included 71 consecutive patients who underwent carotid artery stenting (CAS) due to high grade carotid artery stenosis. Intracranial angiograms and filling status of the ACA pre- and post-stenting were analyzed and a battery of 5 selected neuropsychological tests for frontal lobe function were applied prior to and 6 months after CAS. Patients with improvement in at least two tests were defined as having improved neurocognitive function. RESULTS: Compared to baseline, we found a significant improvement of the Trail-Making Test A (median 6% improved change-score; P = 0.01), the test of supermarket items showed a trend towards significant improvement (median 3.7% improved change-score; P = 0.09). In 32 patients (45%) an improvement of at least 2 neurocognitive tests was observed. Neuropsychological improvement was found more frequently in patients with a contrasted ipsilateral ACA after CAS (88%, 95% CI 77 to 99) compared to patients without angiographic filling of the ipsilateral ACA post CAS (13%, 95% CI 1 to 25), respectively (P < 0.01). CONCLUSION: Carotid artery stenting improves neurocognitive function in a considerable proportion of patients. A contrasted ipsilateral anterior cerebral artery after CAS is associated with improved neurocognitive function, presumably due to amelioration of frontal lobe perfusion.


Subject(s)
Anterior Cerebral Artery/diagnostic imaging , Carotid Stenosis/surgery , Cognition Disorders/epidemiology , Endarterectomy, Carotid , Prostheses and Implants , Stents , Aged , Anterior Cerebral Artery/physiopathology , Cognition Disorders/prevention & control , Endarterectomy, Carotid/adverse effects , Female , Filtration , Frontal Lobe/physiopathology , Humans , Male , Neuropsychological Tests , Postoperative Complications/prevention & control , Prospective Studies , Radiography , Regional Blood Flow , Trail Making Test
12.
J Pediatr Surg ; 42(11): 1898-902, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18022443

ABSTRACT

BACKGROUND: Invasive therapeutic and diagnostic procedures remain the most frequent causes of pediatric vascular injuries. Ideal management, especially the indication for surgical treatment, remains controversial. This study evaluates the outcome of surgical repair for iatrogenic common femoral artery (CFA) injuries in pediatric patients using primary vein patch angioplasty. METHODS: From January 1996 through February 2006, 8 patients were identified in the vascular registry of the Vienna General Hospital in Austria. A retrospective office chart review was performed on this consecutive series of patients treated for iatrogenic CFA injuries using primary vein patch angioplasty. RESULTS: The mean age was 5.8 years (range, 0.3-10.9 years). Surgical repair was performed for 5 ischemic limbs and 3 pseudoaneurysms. Urgent repair was necessary in 5 children (62.5%). After a median follow-up of 9 months (range, 1.8-77.6 months), palpable pedal pulses were present in all patients. No aneurysmatic degeneration of vein patches occurred, and no patient sustained any additional sequelae related to the arterial reconstruction. CONCLUSION: Routine use of a vein patch eases CFA repair, especially in the very young.


Subject(s)
Angioplasty/methods , Catheterization, Peripheral/adverse effects , Femoral Artery/injuries , Femoral Artery/surgery , Iatrogenic Disease , Tissue Transplantation/methods , Aneurysm, False/etiology , Aneurysm, False/surgery , Cardiac Catheterization/adverse effects , Child , Child, Preschool , Female , Follow-Up Studies , Humans , Infant , Ischemia/etiology , Ischemia/surgery , Male , Registries , Retrospective Studies , Risk Assessment , Tissue and Organ Harvesting , Treatment Outcome , Vascular Surgical Procedures/methods
13.
J Endovasc Ther ; 14(4): 452-9, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17696618

ABSTRACT

PURPOSE: To evaluate the agreement of duplex ultrasound (DUS) versus digital subtraction angiography (DSA) for assessment of femoropopliteal arterial disease in a real-world clinical setting. METHODS: Consecutive patients with peripheral artery disease who were scheduled for a percutaneous intervention were included in this retrospective study. During an 18-month period, 491 patients (276 men; median age 73 years, interquartile range 64-81) were enrolled. A peak systolic velocity ratio (PSVR)>2.4 was the optimal cutoff for detecting a >50% stenosis by DSA. Findings of preprocedural DUS in the proximal, middle, and distal ipsilateral superficial femoral artery and in the popliteal segment were analyzed for agreement with preprocedural femoropopliteal DSA using kappa statistics. Only the target limb in each patient was analyzed, for a total of 1964 vascular segments. RESULTS: Agreement for the degree of stenosis in 10% increments was only moderate (weighted kappa 0.67, 95% CI 0.65 to 0.69). Using the PSVR>2.4 cutoff, agreement between DUS and DSA for a >50% stenosis was good (kappa 0.79, 95% CI 0.77 to 0.81). Sensitivity, specificity, positive predictive value, and negative predictive value for correctly detecting a >50% stenosis by DUS were 0.81 (0.78 to 0.84), 0.93 (0.91 to 0.94), 0.84 (0.81 to 0.87), and 0.91 (0.87 to 0.95), respectively. Comparable findings were observed within different patient subgroups. CONCLUSION: Agreement between DUS and DSA in the femoropopliteal segment is only moderate with respect to the absolute degree of stenosis. However, detection of a >50% stenosis can be done with acceptable precision in routine clinical practice using PSVR>2.4 as a threshold.


Subject(s)
Angiography, Digital Subtraction , Arterial Occlusive Diseases , Femoral Artery , Popliteal Artery , Ultrasonography, Doppler, Duplex , Aged , Aged, 80 and over , Arterial Occlusive Diseases/diagnostic imaging , Constriction, Pathologic , Female , Femoral Artery/diagnostic imaging , Humans , Male , Middle Aged , Popliteal Artery/diagnostic imaging , Predictive Value of Tests , ROC Curve , Registries , Research Design , Retrospective Studies , Sensitivity and Specificity , Severity of Illness Index
14.
J Neuroimaging ; 17(3): 219-26, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17608907

ABSTRACT

BACKGROUND AND PURPOSE: In contrast to digital subtraction angiography (DSAdia), computed tomography angiography (CTA) provides exact delineation of the perfused lumen in the axial plane, thus allowing luminal (CTAdia) as well as cross-sectional area (CTAarea) internal carotid artery stenosis (ICAS) assessment. The purposes of the present study were to correlate CTAdia and CTAarea with DSAdia and to assess the inter-observer variabilities of both CTA techniques. METHODS: In a retrospective analysis, CTA images were reviewed by two observers and ICAS was assessed according to North American Symptomatic Carotid Endarterectomy Trial applying CTAdia and CTAarea. DSAdia was assessed by a third observer. RESULTS: Based on 54 consecutive patients (40 males [74.1%] and 14 females [25.9%]; median age 73.3 years), ICAS percentages of CTAdia and CTAarea revealed significant correlations with DSAdia (r= 0.79-0.87, all P<.001) with median differences in the range of +8% to -6%. Inter-observer agreement was moderate for CTAdia (kappa= 0.60) and excellent for CTAarea (kappa= 0.86). Sensitivity of CTAarea for the detection of ICAS >70% was 100% for both observers, corresponding results for CTAdia were 97.1% and 71.4%, respectively, using DSAdia as the gold standard. CONCLUSION: CTAarea assessment of ICAS correlates well with the results of DSAdia and provides an excellent sensitivity for the detection of ICAS >70% with superior inter-observer agreement compared to CTAdia.


Subject(s)
Angiography/methods , Carotid Artery, Internal , Carotid Stenosis/diagnostic imaging , Tomography, X-Ray Computed , Aged , Angiography, Digital Subtraction , Carotid Stenosis/pathology , Female , Humans , Male , Observer Variation , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Sensitivity and Specificity
15.
Neuroradiology ; 49(8): 645-50, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17453179

ABSTRACT

INTRODUCTION: We evaluated the feasibility of multidetector CT angiography (MDCTA) in the examination of vertebral artery (VA) pathologies and correlated the results with those of color Doppler sonography (CDS). METHODS: In this retrospective cohort analysis, we identified 65 patients with suspected cerebrovascular disease, who underwent MDCTA and CDS of the supraaortic vessels within a maximum period of 1 month. We evaluated the feasibility and image quality of MDCTA in this indication, compared the value of reformatted images and axial source images in the grading of stenoses and correlated these results with those of CDS. RESULTS: The image quality of the MDCTA examination was classified as good in 64 patients (98.5%) and as moderate in 1 patient (1.5%). Axial source images and reformatted images agreed perfectly in terms of stenosis detection and grading as well as the detection of hypoplastic VAs (kappa = 1). The correlation between MDCTA and CDS was moderate (kappa = 0.56) in terms of stenosis detection and quantification and poor (kappa = 0.35) in terms of detection of hypoplasia of the VA. CONCLUSION: MDCTA is a feasible method for the evaluation of VA pathologies providing a good image quality. Image reformatting does not add any diagnostic value to the interpretation of axial source images. The correlation between MDCTA and CDS is only moderate, reflecting the clinically important limitations of CDS in this indication.


Subject(s)
Cerebrovascular Disorders/diagnosis , Tomography, X-Ray Computed , Ultrasonography, Doppler, Color , Vertebral Artery/diagnostic imaging , Aged , Angiography/methods , Feasibility Studies , Female , Humans , Male , Retrospective Studies
17.
Arterioscler Thromb Vasc Biol ; 26(11): 2541-6, 2006 Nov.
Article in English | MEDLINE | ID: mdl-16973973

ABSTRACT

BACKGROUND: Obesity is generally accepted as a risk factor for premature atherosclerosis. Subclinical inflammation as quantified by blood levels of C-reactive protein (CRP) contributes to the development and progression of atherosclerosis. We hypothesized that inflammation in obese children is related to functional and early morphological vascular changes. METHODS AND RESULTS: Blood levels of high sensitivity (hs) CRP, hsIL-6, the soluble intercellular adhesion molecule1 (ICAM-1), vascular cell adhesion molecule (VCAM)-1, and E-selectin were measured in 145 severely obese (body mass index [BMI], 32.2+/-5.8 kg/m2) and 54 lean (BMI, 18.9+/-3.2 kg/m2) children 12+/-4 years old. Flow-mediated dilation (FMD) of the brachial artery and carotid intima-media thickness (IMT) measured by high-resolution ultrasound as markers of early vascular changes were assessed in 92 (77 obese and 15 lean) and 59 (50 obese and 9 lean) children, respectively. Obese children had significantly higher levels of hsCRP, hsIL-6, and E-selectin than healthy controls (4.1+/-4.8 versus 0.9+/-1.5 mg/L, P<0.001 for hsCRP; 1.99+/-1.30 versus 1.42+/-1.01 pg/mL, P=0.05 for hsIL-6; and 78+/-38 versus 59+/-29 ng/mL, P=0.01 for E-selectin). There were no differences in the levels of ICAM-1 and VCAM-1 between groups. Obese children had lower peak FMD response (7.70+/-6.14 versus 11.06+/-3.07%, P=0.006) and increased IMT (0.37+/-0.04 versus 0.34+/-0.03 mm, P=0.03) compared with controls. Morbidly obese children (n=14, BMI 44.1+/-3.9 kg/m2) had highest levels of hsCRP (8.7+/-0.7 mg/L), hsIL-6 (3.32+/-1.1 pg/mL), and E-selectin (83+/-40 ng/mL). CONCLUSIONS: A proinflammatory state is detectable in obese children, which is accompanied by impaired vascular endothelial function and early structural changes of arteries, even in young subjects at risk. It remains to be determined whether high hsCRP in obese children predicts cardiovascular events.


Subject(s)
Endothelium, Vascular/diagnostic imaging , Endothelium, Vascular/physiopathology , Inflammation/etiology , Obesity/complications , Obesity/physiopathology , Adolescent , Biomarkers/blood , Brachial Artery/diagnostic imaging , Brachial Artery/physiopathology , C-Reactive Protein/metabolism , Carotid Arteries/diagnostic imaging , Child , Cross-Sectional Studies , E-Selectin/blood , Female , Humans , Interleukin-6/blood , Male , Obesity/blood , Obesity/diagnostic imaging , Obesity, Morbid/blood , Regional Blood Flow , Tunica Intima/diagnostic imaging , Tunica Media/diagnostic imaging , Ultrasonography , Vasodilation
18.
J Endovasc Ther ; 13(4): 443-50, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16928157

ABSTRACT

PURPOSE: To compare the measurements of internal carotid artery (ICA) stenosis obtained from multidetector computed tomographic angiography (CTA) and digital subtraction angiography (DSA) based on the NASCET and ECST grading methods. METHODS: In a retrospective cohort analysis from data at a tertiary care university clinic, the CTA and DSA images from 69 consecutive patients (52 men; mean age 70.3+/-8.0 years, range 51-85) who underwent both imaging studies within a maximum period of 28 days were interpreted by 2 radiologists blinded to the results of the other modality. The exact degree of ICA stenosis was calculated for both modalities according to NASCET and ECST guidelines. RESULTS: The agreement between both stenosis grading methods was comparable for CTA (R2=0.87) and DSA (R2=0.84); mean differences in stenoses grades between ECST and NASCET were 13.9% (CTA) and 12.9% (DSA, p>0.05). Corresponding results for the intermodality correlation were almost equal for NASCET (R2=0.59) and ECST (R2=0.55), with mean differences of 13.4% and 13.5%, respectively (p>0.05). Sensitivity and specificity of CTA for detecting occlusions was 100% for both modalities and grading systems. For detecting stenoses >70%, the sensitivity and specificity were 90.9% and 54.9%, respectively, for NASCET and 94.7% and 46.3%, respectively, for ECST. For stenoses >50%, the values were 95.8% and 59.6%, respectively, for NASCET and 96.4% and 42.5%, respectively, for ECST. CONCLUSION: The introduction of multidetector CTA cannot overcome the confusion in the exact grading of ICA stenosis because the application of both tested modalities as well as both grading methods results in clinically important differences.


Subject(s)
Angiography, Digital Subtraction , Carotid Artery, Internal/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Severity of Illness Index , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity
19.
Radiology ; 240(2): 597-602, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16864680

ABSTRACT

PURPOSE: To prospectively evaluate the accuracy of using physical examination to identify puncture-related groin pseudoaneurysms, as assessed by using duplex ultrasonography (US), after percutaneous transluminal procedures and to prospectively evaluate the association between preinterventional platelet count, antiplatelet medication, and the occurrence of pseudoaneurysms. MATERIALS AND METHODS: This study was approved by the local ethics committee, and informed consent was obtained from all patients. The study prospectively included 273 consecutive patients (161 men, 112 women; age range, 34-90 years) who were referred for duplex US evaluation of the inguinal arterial puncture site 1 day after endovascular procedures. Prior to duplex US, all patients underwent physical examination of the groin. In addition, clinical characteristics and preinterventional laboratory parameters were assessed. Statistical significance was determined by using chi2 tests, the Fischer exact test, and unpaired t tests. RESULTS: Twenty-three pseudoaneurysms were found in 273 patients by using duplex US. Pulsatile groin masses that were detected at physical examination were used to correctly identify all pseudoaneurysms (positive predictive value, 100%; negative predictive value, 100%). Painful pulse palpation had a slightly lower predictive power (positive predictive value, 92% [95% confidence interval: 81%, 100%]; negative predictive value, 100% [95% confidence interval: 100%, 100%]). Other clinical parameters, such as the presence of superficial hematomas, systolic bruits, or nonpulsatile groin masses, had no adequate predictive properties. Interobserver agreement was excellent between observers (97% agreement [95% confidence interval: 92%, 100%]). All patients with pseudoaneurysms had a preprocedural platelet count of less than 200 x 10(9)/L. No subacute complications were observed at the access site in patients with a platelet count of more than 200 x 10(9)/L. CONCLUSION: Physical examination revealed sufficient predictive capability in facilitating the identification of iatrogenic pseudoaneurysms after percutaneous vascular procedures. A platelet count of less than 200 x 10(9)/L was associated with high predictive capability, thereby warranting further assessment in a larger series of patient.


Subject(s)
Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Physical Examination , Punctures/adverse effects , Ultrasonography, Doppler, Duplex , Adult , Aged , Aged, 80 and over , Chi-Square Distribution , Female , Humans , Iatrogenic Disease , Male , Middle Aged , Platelet Count , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity
20.
J Endovasc Ther ; 13(3): 312-9, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16784318

ABSTRACT

PURPOSE: To investigate whether filter-protected carotid artery stenting (CAS) using a covered self-expanding stent reduces the risk of cerebral embolization. METHODS: Fourteen asymptomatic patients (13 men; median age 77 years, IQR 73-83) were enrolled in a randomized pilot trial comparing the rates of cerebral microembolism during and after filter-protected CAS using either a self-expanding covered (n=8) or a bare (n=6) carotid stent. Transcranial Doppler (TCD) monitoring was done during and for 90 minutes after the procedure. Diffusion-weighted magnetic resonance imaging (DW-MRI) was performed before and 24 hours after CAS. Patients were followed for 6 months for neurological events and occurrence of restenosis. RESULTS: A significant reduction in ipsilateral microembolic signals by TCD was observed with the covered (median 1, IQR 0-4) versus the bare stent (median 6, IQR 3-8; p=0.043). Comparison of the preprocedural and 24-hour postprocedural DW-MRI images showed no new ipsilateral lesions but 1 new lesion in the contralateral hemisphere in the covered stent group, resulting in an overall 7% (95% CI 0%-20%) rate of new ischemic lesions. No neurological complications occurred up to 6 months. Restenosis (>70%) occurred in 3 (38%) of 8 patients with the covered versus none of the bare stents (p=0.21). The trial was stopped when the third restenosis of a covered stent was detected. CONCLUSION: Self-expanding covered stents potentially reduce the risk of cerebral microembolism during and after carotid stenting. However, the problem of in-stent restenosis has to be resolved before these devices can be considered for further investigation.


Subject(s)
Angioplasty, Balloon/adverse effects , Carotid Stenosis/therapy , Graft Occlusion, Vascular/diagnosis , Intracranial Embolism/etiology , Stents/adverse effects , Aged , Carotid Artery, Internal/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Female , Humans , Intracranial Embolism/diagnostic imaging , Male , Pilot Projects , Postoperative Complications , Ultrasonography, Doppler, Transcranial
SELECTION OF CITATIONS
SEARCH DETAIL
...