Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Respir Care ; 55(6): 695-701, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20507651

ABSTRACT

BACKGROUND: Cystic fibrosis (CF) patients commonly use a high-frequency chest-wall compression (HFCWC) device for airway clearance that generates oscillatory flow with a sine-wave configuration. Typical HFCWC settings combine a lower Vest inflation pressure setting (eg, 5 on the Vest's arbitrary 1-10 scale for the setting that controls the background pressure of the inflatable vest) with mid-range frequency (14-16 Hz) (lower-pressure/mid-frequency HFCWC). OBJECTIVE: To determine whether HFCWC with higher pressure settings (6-10 on the Hill-Rom Vest's arbitrary 1-10 scale) combined with variable mid-frequencies (8, 9, and 10 Hz, plus 18, 19, and 20 Hz) (higher-pressure/variable-frequency HFCWC) results in greater sputum expectoration than lower-pressure/mid-frequency HFCWC. METHODS: This was a controlled randomized crossover study. Sixteen clinically stable, adult CF patients participated. Patients performed airway clearance with HFCWC, once each with lower-pressure/mid-frequency HFCWC and higher-pressure/variable-frequency HFCWC, on separate occasions. All sputum produced during each session was collected. Patients completed pulmonary function tests before and after each session. RESULTS: Median sputum wet weight was greater with higher-pressure/variable-frequency HFCWC than with lower-pressure/mid-frequency HFCWC (6.4 g, range 0.49-22.0 g, versus 4.8 g, range 0.24-15.0 g, P = .02). Dry sputum weight differences did not reach statistical significance (higher-pressure/variable-frequency HFCWC 0.20 g, range 0.009-0.62 g, lower-pressure/mid-frequency HFCWC 0.12 g, range 0.0001-1.0 g, P = .23). Higher-pressure/variable-frequency HFCWC and lower-pressure/mid-frequency HFCWC resulted in similar increases in FEV(1) (70 mL vs 90 mL, P = .21) and forced vital capacity (80 mL vs 80 mL, P = .94). Post-therapy sputum viscoelastic properties did not differ. Patients perceived the 2 regimens as equally comfortable and effective (P = .35 and P = .35, respectively). CONCLUSIONS: In adult CF patients, single-session higher-pressure/variable-frequency HFCWC resulted in greater sputum expectoration by wet weight, but not other differences, compared to the commonly used lower-pressure/mid-frequency settings. Longer-term comparisons are needed in a larger, more diverse population to determine whether sustained use of the higher-pressure/variable-frequency settings results in clinically important differences in outcomes.


Subject(s)
Chest Wall Oscillation/methods , Cystic Fibrosis/therapy , Adult , Chest Wall Oscillation/instrumentation , Cross-Over Studies , Female , Humans , Male , Sputum , Treatment Outcome
2.
Chest ; 132(4): 1227-32, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17890465

ABSTRACT

BACKGROUND: High-frequency chest wall oscillation (HFCWO) is commonly used by cystic fibrosis (CF) patients for airway clearance. The primary objective of this study was to determine whether the use of a newer HFCWO device that generates oscillations with a triangular waveform results in greater sputum production than a commonly used device that generates oscillations with a sine waveform. METHODS: This was a controlled, randomized, double-blind, crossover study. Fifteen clinically stable, adult CF patients participated. Patients performed airway clearance with each device once and at matched oscillation frequencies and pressures. All sputum produced during each session was collected. Patients completed pulmonary function tests before and after each session, and rated the comfort of the two devices. RESULTS: Mean sputum wet and dry weight produced during sine waveform and triangular waveform HFCWO sessions did not differ (p = 0.11 and p = 0.2, respectively). Mean changes in FEV(1) and FVC following HFCWO therapy were also comparable (p = 0.21 and p = 0.56, respectively). However, there was a significant reduction in air trapping by residual volume/total lung capacity ratio following triangular waveform HFCWO (p = 0.01). In addition, in vitro cough transportability was 10.6% greater following therapy with the triangular waveform device (p = 0.05). Patients perceived the two devices as equally comfortable (p = 0.8). CONCLUSIONS: Single-session sputum production is comparable with sine and triangular waveform HFCWO devices. Longer term comparisons are needed to determine whether sustained use of the devices results in clinically important differences in outcomes.


Subject(s)
Chest Wall Oscillation/methods , Cystic Fibrosis/therapy , Adult , Cross-Over Studies , Double-Blind Method , Female , Humans , Male , Residual Volume , Rheology , Sputum/physiology , Total Lung Capacity
SELECTION OF CITATIONS
SEARCH DETAIL