Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Publication year range
1.
Clinics (Sao Paulo) ; 73: e371, 2018 11 29.
Article in English | MEDLINE | ID: mdl-30517278

ABSTRACT

OBJECTIVE: Explore the feasibility and safety of transcatheter closure of perimembranous ventricular septal defects using a wire-drifting technique (WT) in children. METHODS: We retrospectively analyzed 121 pediatric patients diagnosed with perimembranous ventricular septal defects who underwent interventional treatment at the First Affiliated Hospital of Xi'an Jiaotong University from Dec 2011 to Dec 2014. Based on the method used for arteriovenous loop establishment during the procedure, the patients were divided into a conventional technique (CT) group and a WT group. RESULTS: In total, 51 of the 53 patients (96.2%) in the CT group and 66 of the 68 patients (97.1%) in the WT group achieved procedural success, with no significant difference between the two groups (p>0.05). The CT group showed a nonsignificantly higher one-time success rate of arteriovenous loop establishment (94.3% vs. 91.2%, p>0.05). The procedure time was 46.0 (14.0) min and 46.5 (10.0) min in the CT and WT groups, respectively. The CT procedure was discontinued in the 2 cases (3.8%) of intraprocedural atrioventricular block in the CT group. In the one case (1.9%) of postprocedural atrioventricular block in the CT group, a permanent pacemaker was implanted to resolve third-degree atrioventricular block three months after the procedure. In the WT group, no cases of intraprocedural atrioventricular block occurred, and one case (1.5%) of postprocedural atrioventricular block occurred. In this case, intravenous dexamethasone injection for three days returned the sinus rhythm to normal. Aggravated mild to moderate tricuspid regurgitation was observed in 2 patients (3.8%) in the CT group during the 2-year follow-up period; aggravated tricuspid regurgitation was not observed in the WT group. During the 2-year follow-up period, there was no evidence of residual shunting in either group. CONCLUSION: Transcatheter closure of perimembranous ventricular septal defects with the WT is safe and effective in children.


Subject(s)
Cardiac Catheterization/methods , Heart Septal Defects, Ventricular/surgery , Adolescent , Arteriovenous Shunt, Surgical/methods , Cardiac Catheterization/instrumentation , Child , Child, Preschool , Coronary Angiography/methods , Echocardiography , Female , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Ventricles/diagnostic imaging , Humans , Male , Reproducibility of Results , Retrospective Studies , Septal Occluder Device , Statistics, Nonparametric , Treatment Outcome
2.
Clinics ; 73: e371, 2018. tab, graf
Article in English | LILACS | ID: biblio-974921

ABSTRACT

OBJECTIVE: Explore the feasibility and safety of transcatheter closure of perimembranous ventricular septal defects using a wire-drifting technique (WT) in children. METHODS: We retrospectively analyzed 121 pediatric patients diagnosed with perimembranous ventricular septal defects who underwent interventional treatment at the First Affiliated Hospital of Xi'an Jiaotong University from Dec 2011 to Dec 2014. Based on the method used for arteriovenous loop establishment during the procedure, the patients were divided into a conventional technique (CT) group and a WT group. RESULTS: In total, 51 of the 53 patients (96.2%) in the CT group and 66 of the 68 patients (97.1%) in the WT group achieved procedural success, with no significant difference between the two groups (p>0.05). The CT group showed a nonsignificantly higher one-time success rate of arteriovenous loop establishment (94.3% vs. 91.2%, p>0.05). The procedure time was 46.0 (14.0) min and 46.5 (10.0) min in the CT and WT groups, respectively. The CT procedure was discontinued in the 2 cases (3.8%) of intraprocedural atrioventricular block in the CT group. In the one case (1.9%) of postprocedural atrioventricular block in the CT group, a permanent pacemaker was implanted to resolve third-degree atrioventricular block three months after the procedure. In the WT group, no cases of intraprocedural atrioventricular block occurred, and one case (1.5%) of postprocedural atrioventricular block occurred. In this case, intravenous dexamethasone injection for three days returned the sinus rhythm to normal. Aggravated mild to moderate tricuspid regurgitation was observed in 2 patients (3.8%) in the CT group during the 2-year follow-up period; aggravated tricuspid regurgitation was not observed in the WT group. During the 2-year follow-up period, there was no evidence of residual shunting in either group. CONCLUSION: Transcatheter closure of perimembranous ventricular septal defects with the WT is safe and effective in children.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Cardiac Catheterization/methods , Heart Septal Defects, Ventricular/surgery , Arteriovenous Shunt, Surgical/methods , Echocardiography , Cardiac Catheterization/instrumentation , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Coronary Angiography/methods , Statistics, Nonparametric , Septal Occluder Device , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Ventricles/diagnostic imaging
3.
Zhonghua Xin Xue Guan Bing Za Zhi ; 37(11): 981-5, 2009 Nov.
Article in Chinese | MEDLINE | ID: mdl-20137320

ABSTRACT

OBJECTIVE: To analyze factors influencing the choice of atrial septal occluder (ASO) for transcatheter closure of patients with secundum atrial septal defect (ASD). METHODS: A total of 1114 ASD patients [388 males, aged from 2 to 75 years, mean age (26.3 +/- 17.0) years] were enrolled. Patients were divided to adult (> 14 years, mean 34.4 years, n = 779) and child (< or = 14 years, mean 7.3 years, n = 335) groups. ASD size in different ultrasound cross-sections was determined by transthoracic echocardiography (TTE). ASO size was chosen on the basis of the maximum diameter of the defect (MD). Defect-shapes and rim lengths of ASD, the difference choice of ASO in the two groups were compared. RESULTS: MD of the defects ranged from 5 to 40 mm [mean (19.7 +/- 7.8) mm]. ASD was successfully occluded in 1085 out of 1114 patients (97.4%). Occluder size ranged from 6 to 46 mm [mean (25.8 +/- 8.9) mm] and the difference between occluder size and MD ranged from 2 to 10 mm [mean (6.1 +/- 3.4) mm, ASO/MD ratio 1.3:1]. Though the diameter of the defect was similar between the 2 groups, the size of occluder was significantly larger in adult group than that in child group (ASO/MD ratio 1.1 - 1.6:1 vs. 1.2 - 1.8:1, P < 0.05). MD was significantly correlated with ASO in both groups (r = 0.911 and r = 0.944 in adults and child groups, respectively, all P < 0.01). The size and increment of the occluder used in patients with deficient anterior rims was significantly bigger than patients with sufficient anterior rims (P < 0.01). CONCLUSION: The maximum diameter of the defect was the major determinant for selecting occluder size and choice of occluder size was also influenced by patient age, defect-shape and defect rim for transcatheter closure of secundum ASD.


Subject(s)
Cardiac Catheterization/instrumentation , Heart Septal Defects, Atrial/therapy , Physicians/psychology , Septal Occluder Device , Adolescent , Adult , Age Factors , Aged , Child , Child, Preschool , Echocardiography , Female , Humans , Male , Middle Aged , Practice Patterns, Physicians' , Prosthesis Design , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL