Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
PLoS One ; 16(2): e0244633, 2021.
Article in English | MEDLINE | ID: mdl-33544707

ABSTRACT

PURPOSE: Studies using magnetic resonance imaging to assess lumbar multifidus cross-sectional area frequently utilize T1 or T2-weighted sequences, but seldom provide the rationale for their sequence choice. However, technical considerations between their acquisition protocols could impact on the ability to assess lumbar multifidus anatomy or its fat/muscle distinction. Our objectives were to examine the concurrent validity of lumbar multifidus morphology measures of T2 compared to T1-weighted sequences, and to assess the reliability of repeated lumbar multifidus measures. METHODS: The lumbar multifidus total cross-sectional area of 45 patients was measured bilaterally at L4 and L5, with histogram analysis determining the muscle/fat threshold values per muscle. Images were later re-randomized and re-assessed for intra-rater reliability. Matched images were visually rated for consistency of outlining between both image sequences. Bland-Altman bias, limits of agreement, and plots were calculated for differences in total cross-sectional area and percentage fat between and within sequences, and intra-rater reliability analysed. RESULTS: T1-weighted total cross-sectional area measures were systematically larger than T2 (0.2 cm2), with limits of agreement <±10% at both spinal levels. For percentage fat, no systematic bias occurred, but limits of agreement approached ±15%. Visually, muscle outlining was consistent between sequences, with substantial mismatches occurring in <5% of cases. Intra-rater reliability was excellent (ICC: 0.981-0.998); with bias and limits of agreement less than 1% and ±5%, respectively. CONCLUSION: Total cross-sectional area measures and outlining of muscle boundaries were consistent between sequences, and intra-rater reliability for total cross-sectional area and percentage fat was high indicating that either MRI sequence could be used interchangeably for this purpose. However, further studies comparing the accuracy of various methods for distinguishing fat from muscle are recommended.


Subject(s)
Adipose Tissue/diagnostic imaging , Low Back Pain/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Paraspinal Muscles/diagnostic imaging , Humans , Magnetic Resonance Imaging
2.
Phys Ther Sport ; 32: 212-220, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29807278

ABSTRACT

OBJECTIVES: To investigate the intra- and interrater reliability and agreement for field-based assessment of scapular control, shoulder range of motion (ROM), and shoulder isometric strength in elite youth athletes. DESIGN: Test-retest reliability and agreement study. SETTING: Eight blinded raters (two for each assessment) assessed players on field during two testing sessions separated by one week. PARTICIPANTS: 162 elite youth handball players with or without a history of previous shoulder pain within the preceding six months. MAIN OUTCOME MEASURES: Kappa (κ) and prevalence-adjusted bias-adjusted kappa (PABAK) coefficients for scapular control reliability, and 95% limits of agreement (LOA) for ROM and strength agreement. RESULTS: Scapular control demonstrated substantial to almost perfect reliability (κ 0.67 to 0.84, PABAK from 0.68 to 0.88). Mean strength values ranged from 0.9 N/kg to 1.6 N/kg, and LOAs ranged from -0.7 N/kg to 0.8 N/kg. Rotational strength revealed additionally systematic bias between and within rater. No or acceptable systematic bias were evident for ROM and abduction strength measures. Mean values and LOAs for ROM ranged between 39.9° to 52.3°, and from -12.6° to 9.9°, respectively. CONCLUSIONS: Scapular control and ROM can be assessed on the field with acceptable reliability. The threshold for reliable measurements of isometric strength using handheld-dynamometers is high.


Subject(s)
Muscle Strength , Range of Motion, Articular , Adolescent , Athletes , Female , Humans , Male , Muscle Strength Dynamometer , Observer Variation , Reproducibility of Results , Scapula/physiology , Shoulder Injuries
3.
Scand J Med Sci Sports ; 28(4): 1424-1434, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29286552

ABSTRACT

Current methods of sports injury surveillance are limited by lack of medical validation of self-reported injuries and/or incomplete information about injury consequences beyond time loss from sport. The aims of this study were to (a) evaluate the feasibility of the SMS, Phone, and medical Examination injury surveillance (SPEx) system (b) to evaluate the proportion of injuries and injury consequences reported by SPEx when compared to outcomes from a modified version of the Oslo Sports Trauma Research Centre (OSTRC) Overuse Injury Questionnaire. We followed 679 elite adolescent handball players over 31 weeks using the SPEx system. During the last 7 weeks, we also implemented a modified OSTRC questionnaire in a subgroup of 271 players via telephone interviews. The weekly response proportions to the primary SPEx questions ranged from 85% to 96% (mean 92%). SMS responses were received from 79% of the participants within 1 day. 95% of reported injuries were classified through the telephone interview within a week, and 67% were diagnosed by medical personnel. Comparisons between reported injuries from SPEx and OSTRC demonstrated fair (κ = 39.5% [25.1%-54.0%]) to substantial prevalence-adjusted bias-adjusted kappa (PABAK = 66.8% [95% CI 58.0%-75.6%]) agreement. The average injury severity score difference between SPEx and the OSTRC approach was -0.2 (95% CI -3.69-3.29) of possible 100 with 95% limits of agreement from(-14.81-14.41). These results support the feasibility and validity of the SPEx injury surveillance system in elite youth sport. Future studies should evaluate the external validity of SPEx system in different cohorts of athletes.


Subject(s)
Athletic Injuries/diagnosis , Physical Examination , Telephone , Text Messaging , Adolescent , Athletes , Denmark , Feasibility Studies , Female , Humans , Injury Severity Score , Male , Surveys and Questionnaires , Youth Sports
4.
Scand J Med Sci Sports ; 28(1): 252-259, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28267868

ABSTRACT

The accurate measurement of sport exposure time and injury occurrence is key to effective injury prevention and management. Current measures are limited by their inability to identify all types of sport-related injury, narrow scope of injury information, or lack the perspective of the injured athlete. The aims of the study were to evaluate the proportion of injuries and the agreement between sport exposures reported by the SMS messaging and follow-up telephone part of the SMS, Phone, and medical staff Examination (SPEx) sports injury surveillance system when compared to measures obtained by trained on-field observers and medical staff (comparison method). We followed 24 elite adolescent handball players over 12 consecutive weeks. Eighty-six injury registrations were obtained by the SPEx and comparison methods. Of them, 35 injury registrations (41%) were captured by SPEx only, 10 injury registrations (12%) by the comparison method only, and 41 injury registrations (48%) by both methods. Weekly exposure time differences (95% limits of agreement) between SPEx and the comparison method ranged from -4.2 to 6.3 hours (training) and -1.5 to 1.0 hours (match) with systematic differences being 1.1 hours (95% CI 0.7 to 1.4) and -0.2 (95% CI -0.3 to -0.2), respectively. These results support the ability of the SPEx system to measure training and match exposures and injury occurrence among young athletes. High weekly response proportions (mean 83%) indicate that SMS messaging can be used for player measures of injury consequences beyond time-loss from sport. However, this needs to be further evaluated in large-scale studies.


Subject(s)
Athletic Injuries/epidemiology , Registries , Telemedicine , Text Messaging , Adolescent , Athletes , Athletic Injuries/diagnosis , Denmark , Female , Humans , Male , Medical Staff , Prospective Studies , Sports , Time Factors
5.
Complement Ther Med ; 22(2): 286-95, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24731900

ABSTRACT

BACKGROUND: Scant research has been undertaken regarding chiropractors' skills and knowledge associated with evidence-based practice (EBP), and their perceived barriers to EBP. These issues appear to have been examined in only one small qualitative study and one small study of chiropractors holding orthopaedic diplomas. The lack of research in this area suggests that additional studies are warranted to develop a better understanding of factors that affect chiropractors' use of research evidence in clinical practice. METHODS: We used a modified online questionnaire that captured information regarding EBP skills and knowledge, and barriers to EBP. Its adaption was informed by the use of a content validity panel. The questionnaire was disseminated through email by Australian chiropractic professional organisations and the Chiropractic Board of Australia. Logistic regression analyses were conducted to examine univariate associations between responses to items measuring knowledge and skills with items measuring: age; years since registration; reading research literature; and use of research literature in clinical decision-making. RESULTS: 584 respondents returned questionnaires. About half of the respondents stated they had learned the foundations of EBP (56.6%) during their undergraduate training. Slightly more than two thirds of the respondents were confident in their ability to critically review literature (69.5%) and find relevant research to answer clinical questions (72.6%). The most common factors involved with reading more research, and increased use of research literature in clinical decision-making, were confidence in critical appraisal skills and confidence in finding relevant research literature. Conclusion Educational interventions should be implemented to enhance Australian chiropractors' fundamental EBP skills.


Subject(s)
Chiropractic/statistics & numerical data , Clinical Competence/statistics & numerical data , Evidence-Based Medicine , Health Personnel/statistics & numerical data , Adult , Australia/epidemiology , Data Collection , Female , Humans , Male , Middle Aged , Surveys and Questionnaires , Young Adult
6.
Abdom Imaging ; 31(1): 48-53, 2006.
Article in English | MEDLINE | ID: mdl-16252139

ABSTRACT

BACKGROUND: We designed and evaluated a low-attenuation oral contrast agent for abdominal-pelvic computed tomography (CT). METHODS: In vitro studies, were performed initially to evaluate the imaging characteristics of multiple solutions. These studies resulted in two solutions being compared with the presently accepted oral CT agents of dilute iodinated contrast and water. Ninety-eight consecutive subjects already scheduled for routine outpatient abdominal-pelvic CT were enrolled. Subjects were randomized to water (n = 30), fiber solution (n = 32), polyethylene glycol (PEG; n = 11), or dilute iodinated solution (DI; n = 25). Examinations were then evaluated for gastric distention, small bowel distention, small bowel wall visualization, and colonic transit. A questionnaire was given to the study subjects for feedback concerning taste and potential side effects from these agents. RESULTS: PEG tended to provide better bowel distention, wall visualization, and colonic transit compared with water, fiber solution, and DI. Areas of statistical significance included: (1) average bowel diameter in the left upper quadrant for water was 17.50 mm, whereas that for PEG was 21.88 mm (p < 0.05); (2) average bowel diameter in the pelvis for water was 14.79 mm, that for fiber was 15.67 mm, and that for PEG was 18.48 mm (p < 0.05); (3) wall visualization was better with PEG than with fiber (p < 0.05); (4) successful transit of contrast to the colon occurred in every subject who received PEG compared with only 20% of those received water and 39% of those who received fiber (p < 0.05). Similar trends for the superiority of PEG over DI were noted, although many of these did not reach statistical significance. CONCLUSION: PEG solution has imaging characteristics related to bowel wall visualization, luminal distention, and colonic transit that make it an effective oral agent for abdominal pelvic CT examination.


Subject(s)
Contrast Media , Polyethylene Glycols , Surface-Active Agents , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Humans , Methylcellulose , Middle Aged , Phantoms, Imaging , Radiography, Abdominal
8.
Biotech Histochem ; 66(3): 122-4, 1991.
Article in English | MEDLINE | ID: mdl-1888795

ABSTRACT

A quick embedding method employing UV polymerization reactions has been devised for embedding fibers in acrylic and methacrylate media. The resultant thin, flat embeddings are suitable for both light and electron microscopy.


Subject(s)
Histological Techniques , Microscopy, Electron , Textiles , Fixatives , Methacrylates , Ultraviolet Rays
9.
Science ; 227(4682): 79, 1985 Jan 04.
Article in English | MEDLINE | ID: mdl-17810028
SELECTION OF CITATIONS
SEARCH DETAIL