Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Sports Med ; 40(1): 62-70, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30508863

ABSTRACT

Positive effects of exercise on cancer prevention and progression have been proposed to be mediated by stimulating natural killer (NK) cells. Because NK cell receptors are regulated by epigenetic modifications, we investigated whether acute aerobic exercise and training change promoter DNA methylation and gene expression of the activating KIR2DS4 and the inhibiting KIR3DL1 gene. Sixteen healthy women (50-60 years) performed a graded exercise test (GXT) and were randomized into either a passive control group or an intervention group performing a four-week endurance exercise intervention. Blood samples (pre-, post-GXT and post-training) were used for isolation of DNA/RNA of NK cells to assess DNA promoter methylation by targeted deep-amplicon sequencing and gene expression by qRT-PCR. Potential changes in NK cell subsets were determined by flow cytometry. Acute and chronic exercise did not provoke significant alterations of NK cell proportions. Promoter methylation decreased and gene expression increased for KIR2DS4 after acute exercise. A high gene expression correlated with a low methylation of CpGs that were altered by acute exercise. Chronic exercise resulted in a minor decrease of DNA methylation and did not alter gene expression. Acute exercise provokes epigenetic modifications, affecting the balance between the activating KIR2DS4 and the inhibiting KIR3DL1, with potential benefits on NK cell function.


Subject(s)
DNA Methylation , Exercise/physiology , Killer Cells, Natural/metabolism , Promoter Regions, Genetic , Receptors, KIR/genetics , Demethylation , Epigenesis, Genetic , Exercise Test , Female , Gene Expression , Humans , Middle Aged
2.
Biosens Bioelectron ; 127: 25-30, 2019 Feb 15.
Article in English | MEDLINE | ID: mdl-30583283

ABSTRACT

Gold electrodes have been used in a wide range of electrochemical biosensors because their functionalization process with thiols has been well described and, in general, they offer good chemical stability. However, one of the most commonly used redox-pairs in electrochemical impedance spectroscopy, Hexacyanoferrate (II)/(III), causes corrosion of the gold electrodes and consequently damages the surface modification. This leads to alterations of the sensing signals, and thus, renders the quantitative and sensitive detection of target molecules virtually impossible. To overcome this problem we introduced the in-situ generation of Hexaammineruthenium (II)/(III) as redox-pair during the impedimetric measurement by applying a DC-bias. This DC-bias was chosen in such a way that it supplied Hexaammineruthenium (II) in a suitable concentration at the electrode surface by reducing Hexaammineruthenium (III). We compared the stability of photolithographically fabricated thin-film and screen-printed gold electrodes in Hexacyanoferrate and Hexaammineruthenium solutions. Further, long-time characterization of the electrochemical properties with cyclic voltammetry and electrochemical impedance spectroscopy revealed that Hexaammineruthenium (II)/(III) was an excellent redox-pair for stable impedimetric measurements with gold electrodes. To demonstrate the suitability of Hexaammineruthenium for biosensing we applied it for the impedimetric detection of human-IgG. This biosensor exhibited a linear range from 11.3 ng/mL to 113 µg/mL, which is a suitable range for diagnostic applications.


Subject(s)
Biosensing Techniques , Dielectric Spectroscopy , Immunoglobulin G/isolation & purification , Electrodes , Ferrocyanides/chemistry , Gold/chemistry , Humans , Immunoglobulin G/chemistry , Oxidation-Reduction , Ruthenium Compounds/chemistry
3.
Biosens Bioelectron ; 34(1): 63-9, 2012 Apr 15.
Article in English | MEDLINE | ID: mdl-22366376

ABSTRACT

Biosensor systems which enable impedance measurements on adherent cell layers under label-free conditions are considered powerful tools for monitoring specific biological characteristics. A radio frequency identification-based sensor platform was adopted to characterize cultivation and differentiation of human bone marrow-derived multipotent stem cells (bmMSC) over periods of up to several days and weeks. Electric cell-substrate impedance sensing was achieved through fabrication of sensitive elements onto glass substrates which comprised two comb-shaped interdigitated gold electrodes covering an area of 1.8 mm×2 mm. The sensing systems were placed into the wells of a 6-well tissue culture plate, stacked onto a reader unit and could thus be handled and operated under sterile conditions. Continuous measurements were carried out with a sinusoidal voltage of 35 mV at a frequency of 10 kHz. After seeding of human bmMSC, this sensor was able to trace significant impedance changes contingent upon cell spreading and adhesion. The re-usable system was further proven suitable for live examination of cell-substrate attachment or continuous cell monitoring up to several weeks. Induction of either osteogenic or adipogenic differentiation could be validated in bmMSC cultures within a few days, in contrast to state-of-the-art protocols, which require several weeks of cultivation time. In the context of medical cell production in a GMP-compliant process, the here presented interdigitated electric microsensor technology allows the documentation of MSC quality in a fast, efficient and reliable fashion.


Subject(s)
Biosensing Techniques/methods , Cell Differentiation , Electric Impedance , Mesenchymal Stem Cells/cytology , Adipogenesis , Humans , Osteogenesis
4.
Biomed Microdevices ; 13(3): 463-73, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21271358

ABSTRACT

In this article we present a long target droplet polymerase chain reaction (PCR) microsystem for the amplification of the 16S ribosomal RNA gene. It is used for detecting Gram-positive and Gram-negative pathogens at high-throughput and is optimised for downstream species identification. The miniaturised device consists of three heating plates for denaturation, annealing and extension arranged to form a triangular prism. Around this prism a fluoropolymeric tubing is coiled, which represents the reactor. The source DNA was thermally isolated from bacterial cells without any purification, which proved the robustness of the system. Long target sequences up to 1.3 kbp from Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa have successfully been amplified, which is crucial for the successive species classification with DNA microarrays at high accuracy. In addition to the kilobase amplicon, detection limits down to DNA concentrations equivalent to 10(2) bacterial cells per reaction were achieved, which qualifies the microfluidic device for clinical applications. PCR efficiency could be increased up to 2-fold and the total processing time was accelerated 3-fold in comparison to a conventional thermocycler. Besides this speed-up, the device operates in continuous mode with consecutive droplets, offering a maximal throughput of 80 samples per hour in a single reactor. Therefore we have overcome the trade-off between target length, sensitivity and throughput, existing in present literature. This qualifies the device for the application in species identification by PCR and microarray technology with high sample numbers. Moreover early diagnosis of infectious diseases can be implemented, allowing immediate species specific antibiotic treatment. Finally this can improve patient convalescence significantly.


Subject(s)
Bacteria/genetics , Bacteria/isolation & purification , Microfluidic Analytical Techniques/instrumentation , Polymerase Chain Reaction/instrumentation , Animals , Cattle , Humans , Limit of Detection , Quality Control , RNA, Bacterial/chemistry , RNA, Bacterial/genetics , RNA, Ribosomal, 16S/chemistry , RNA, Ribosomal, 16S/genetics , Time Factors
5.
Lab Chip ; 7(12): 1723-31, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18030393

ABSTRACT

Microfabricated biochips are developed to continuously monitor cell population dynamics in a non-invasive manner. In the presented work we describe the novel combination of contact-less dielectric microsensors and microfluidics to promote biofilm formation for quantitative cell analysis. The cell chip consists of a polymeric fluidic (PDMS) system bonded to a glass wafer containing the electrodes while temperature and fluid flow are controlled by external heating and pumping stations. The high-density interdigitated capacitors (microIDES) are isolated by a 550 nm multi-passivation layer of defined dielectric property and provide stable, robust and non-drifting measurement conditions. The performance of this detector is evaluated using various bacterial and yeast strains. The high sensitivity of the developed dielectric microsensors allows direct identification of microbial strains based on morphological differences and biological composition. The novel biofilm analysis platform is used to continuously monitor the dynamic responses of C. albicans and P. pastoris biofilms to increased shear stress and antimicrobial agent concentration. While the presence of shear stress triggers significant changes in yeast growth profiles, the addition of 0.5 microg mL(-1) amphotericin B revealed two distinct dynamic behaviors of the C. albicans biofilm. Initially, impedance spectra increased linearly at 30 Omega h(-1) for two hours followed by 10 Omega h(-1) (at 50 kHz) over 10 hours while cell viability remained above 95% during fungicide administration. These results demonstrate the ability to directly monitor dielectric changes of sub-cellular components within a living cell population.


Subject(s)
Biofilms , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Online Systems/instrumentation , Cell Membrane
SELECTION OF CITATIONS
SEARCH DETAIL
...