Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
BMC Musculoskelet Disord ; 24(1): 395, 2023 May 18.
Article in English | MEDLINE | ID: mdl-37198565

ABSTRACT

INTRODUCTION: In lumbar spinal stabilization pedicle screws are used as standard. However, especially in osteoporosis, screw anchorage is a problem. Cortical bone trajectory (CBT) is an alternative technique designed to increase stability without the use of cement. In this regard, comparative studies showed biomechanical superiority of the MC (midline cortical bone trajectory) technique with longer cortical progression over the CBT technique. The aim of this biomechanical study was to comparatively investigate the MC technique against the not cemented pedicle screws (TT) in terms of their pullout forces and anchorage properties during sagittal cyclic loading according to the ASTM F1717 test. METHODS: Five cadavers (L1 to L5), whose mean age was 83.3 ± 9.9 years and mean T Score of -3.92 ± 0.38, were dissected and the vertebral bodies embedded in polyurethane casting resin. Then, one screw was randomly inserted into each vertebra using a template according to the MC technique and a second one was inserted by freehand technique with traditional trajectory (TT). The screws were quasi-static extracted from vertebrae L1 and L3, while for L2, L4 and L5 they were first tested dynamically according to ASTM standard F1717 (10,000 cycles at 1 Hz between 10 and 110 N) and then quasi-static extracted. In order to determine possible screw loosening, there movements were recorded during the dynamic tests using an optical measurement system. RESULTS: The pull-out tests show a higher pull-out strength for the MC technique of 555.4 ± 237.0 N compared to the TT technique 448.8 ± 303.2 N. During the dynamic tests (L2, L4, L5), 8 out of the 15 TT screws became loose before completing 10,000 cycles. In contrast, all 15 MC screws did not exceed the termination criterion and were thus able to complete the full test procedure. For the runners, the optical measurement showed greater relative movement of the TT variant compared to the MC variant. The pull-out tests also revealed that the MC variant had a higher pull-out strength, measuring at766.7 ± 385.4 N, while the TT variant measured 637.4 ± 435.6 N. CONCLUSION: The highest pullout forces were achieved by the MC technique. The main difference between the techniques was observed in the dynamic measurements, where the MC technique exhibited superior primary stability compared to the conventional technique in terms of primary stability. Overall, the MC technique in combination with template-guided insertion represents the best alternative for anchoring screws in osteoporotic bone without cement.


Subject(s)
Osteoporosis , Pedicle Screws , Spinal Fusion , Humans , Aged , Aged, 80 and over , Lumbar Vertebrae/surgery , Bone and Bones , Osteoporosis/surgery , Cortical Bone/surgery , Bone Cements , Biomechanical Phenomena , Spinal Fusion/methods
2.
Sci Rep ; 11(1): 23816, 2021 12 10.
Article in English | MEDLINE | ID: mdl-34893697

ABSTRACT

The goal of this study is to compare the construct stability of long segmental dorsal stabilization in unstable midthoracic osteoporotic fractures with complete pedicle screw cement augmentation (ComPSCA) versus restricted pedicle screw cement augmentation (ResPSCA) of the most cranial and caudal pedicle screws under cyclic loading. Twelve fresh frozen human cadaveric specimens (Th4-Th10) from individuals aged 65 years and older were tested in a biomechanical cadaver study. All specimens received a DEXA scan and computer tomography (CT) scan prior to testing. All specimens were matched into pairs. These pairs were randomized into the ComPSCA group and ResPSCA group. An unstable Th7 fracture was simulated. Periodic bending in flexion direction with a torque of 2.5 Nm and 25,000 cycles was applied. Markers were applied to the vertebral bodies to measure segmental movement. After testing, a CT scan of all specimens was performed. The mean age of the specimens was 87.8 years (range 74-101). The mean T-score was - 3.6 (range - 1.2 to - 5.3). Implant failure was visible in three specimens, two of the ComPSCA group and one of the ResPSCA group, affecting only one pedicle screw in each case. Slightly higher segmental movement could be evaluated in these three specimens. No further statistically significant differences were observed between the study groups. The construct stability under cyclic loading in flexion direction of long segmental posterior stabilization of an unstable osteoporotic midthoracic fracture using ResPSCA seems to be comparable to ComPSCA.


Subject(s)
Bone Cements/therapeutic use , Osteoporotic Fractures/surgery , Pedicle Screws , Spinal Fractures/surgery , Thoracic Vertebrae/pathology , Thoracic Vertebrae/surgery , Age Factors , Aged , Aged, 80 and over , Female , Humans , Male , Osteoporotic Fractures/diagnosis , Osteoporotic Fractures/etiology , Range of Motion, Articular , Spinal Fractures/diagnosis , Spinal Fractures/etiology , Tomography, X-Ray Computed , Treatment Outcome
3.
Orthopade ; 50(8): 608-613, 2021 Aug.
Article in German | MEDLINE | ID: mdl-34228159

ABSTRACT

Deformity due to neuromuscular disease is often progressive and associated with reduced vital capacity. In general, all treatment should be performed in specialized centers, since invasive measures are associated with an increased morbidity compared to adolescent scoliosis. Derived from the etiology and the resulting biomechanical basis (characteristics), important aspects and considerations arise for all healthcare institutions from the examination interval to the duration of conservative therapy and initiation of surgical therapy. Proper monitoring and assessment are key components to identify curve progression and to achieve preservation or improvement of basic functions.


Subject(s)
Neuromuscular Diseases , Scoliosis , Adolescent , Humans , Neuromuscular Diseases/epidemiology , Prognosis , Scoliosis/diagnosis , Scoliosis/epidemiology
4.
World Neurosurg ; 152: e540-e548, 2021 08.
Article in English | MEDLINE | ID: mdl-34129990

ABSTRACT

BACKGROUND: Intervertebral fusions in cases of reduced bone density are a tough challenge. From a biomechanical point of view, most current studies have focused on the range of motion or have shown test setups for single-component tests. Definitive setups for biomechanical testing of the primary stability of a 360° fusion using a screw-rod system and cage on osteoporotic spine are missing. The aim of this study was to develop a test stand to provide information about the bone-implant interface under reproducible conditions. METHODS: After pretesting with artificial bone, functional spine units were tested with 360° fusion in the transforaminal lumbar interbody fusion technique. The movement sequences were conducted in flexion/extension, right and left lateral bending, and right and left axial rotation on a human model with osteopenia or osteoporosis under permanent maximum load with 7.5 N-m. RESULTS: During the testing of human cadavers, 4 vertebrae were fully tested and were inconspicuous even after radiological and macroscopic examination. One vertebra showed a subsidence of 2 mm, and 1 vertebra had a cage collapsed into the vertebra. CONCLUSIONS: This setup is suitable for biomechanical testing of cyclical continuous loads on the spine with reduced bone quality or osteoporosis. The embedding method is stable and ensures a purely single-level setup with different trajectories, especially when using the cortical bone trajectory. Optical monitoring provides a very accurate indication of cage movement, which correlates with the macroscopic and radiological results.


Subject(s)
Absorbable Implants , Bone Diseases, Metabolic/therapy , Diffusion Chambers, Culture , Models, Anatomic , Osteoporosis/therapy , Spine/surgery , Aged , Aged, 80 and over , Biomechanical Phenomena , Bone Diseases, Metabolic/diagnostic imaging , Bone Diseases, Metabolic/surgery , Bone Screws , Cadaver , Equipment Design , Female , Humans , Male , Materials Testing , Osteoporosis/diagnostic imaging , Osteoporosis/surgery , Prosthesis Design , Range of Motion, Articular , Spinal Fusion , Spine/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...