Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Vis Exp ; (169)2021 03 03.
Article in English | MEDLINE | ID: mdl-33749678

ABSTRACT

Fragment screening is a technique that helps to identify promising starting points for ligand design. Given that crystals of the target protein are available and display reproducibly high-resolution X-ray diffraction properties, crystallography is among the most preferred methods for fragment screening because of its sensitivity. Additionally, it is the only method providing detailed 3D information of the binding mode of the fragment, which is vital for subsequent rational compound evolution. The routine use of the method depends on the availability of suitable fragment libraries, dedicated means to handle large numbers of samples, state-of-the-art synchrotron beamlines for fast diffraction measurements and largely automated solutions for the analysis of the results. Here, the complete practical workflow and the included tools on how to conduct crystallographic fragment screening (CFS) at the Helmholtz-Zentrum Berlin (HZB) are presented. Preceding this workflow, crystal soaking conditions as well as data collection strategies are optimized for reproducible crystallographic experiments. Then, typically in a one to two-day procedure, a 96-membered CFS-focused library provided as dried ready-to-use plates is employed to soak 192 crystals, which are then flash-cooled individually. The final diffraction experiments can be performed within one day at the robot-mounting supported beamlines BL14.1 and BL14.2 at the BESSY  II electron storage ring operated by the HZB in Berlin-Adlershof (Germany). Processing of the crystallographic data, refinement of the protein structures, and hit identification is fast and largely automated using specialized software pipelines on dedicated servers, requiring little user input. Using the CFS workflow at the HZB enables routine screening experiments. It increases the chances for successful identification of fragment hits as starting points to develop more potent binders, useful for pharmacological or biochemical applications.


Subject(s)
Crystallography, X-Ray , Drug Evaluation, Preclinical , Berlin , Crystallization , Data Collection , Ligands , Proteins/chemistry , Software , Synchrotrons , Workflow
2.
J Synchrotron Radiat ; 26(Pt 2): 393-405, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30855248

ABSTRACT

MXCuBE2 is the second-generation evolution of the MXCuBE beamline control software, initially developed and used at ESRF - the European Synchrotron. MXCuBE2 extends, in an intuitive graphical user interface (GUI), the functionalities and data collection methods available to users while keeping all previously available features and allowing for the straightforward incorporation of ongoing and future developments. MXCuBE2 introduces an extended abstraction layer that allows easy interfacing of any kind of macromolecular crystallography (MX) hardware component, whether this is a diffractometer, sample changer, detector or optical element. MXCuBE2 also works in strong synergy with the ISPyB Laboratory Information Management System, accessing the list of samples available for a particular experimental session and associating, either from instructions contained in ISPyB or from user input via the MXCuBE2 GUI, different data collection types to them. The development of MXCuBE2 forms the core of a fruitful collaboration which brings together several European synchrotrons and a software development factory and, as such, defines a new paradigm for the development of beamline control platforms for the European MX user community.

3.
Article in English | MEDLINE | ID: mdl-22869138

ABSTRACT

The use of longer X-ray wavelengths in macromolecular crystallography has grown significantly over the past few years. The main reason for this increased use of longer wavelengths has been to utilize the anomalous signal from sulfur, providing a means for the experimental phasing of native proteins. Here, another possible application of longer X-ray wavelengths is presented: MAD at the L(III) edges of various lanthanide compounds. A first experiment at the L(III) edge of Pr was conducted on HZB MX beamline BL14.2 and resulted in the successful structure determination of the C-terminal domain of a spliceosomal protein. This experiment demonstrates that L(III) edges of lanthanides constitute potentially attractive targets for long-wavelength MAD experiments.


Subject(s)
Crystallography, X-Ray/methods , Proteins/analysis , Models, Molecular , Protein Structure, Secondary , Protein Structure, Tertiary
4.
J Synchrotron Radiat ; 19(Pt 3): 442-9, 2012 May.
Article in English | MEDLINE | ID: mdl-22514183

ABSTRACT

Three macromolecular crystallography (MX) beamlines at the Helmholtz-Zentrum Berlin (HZB) are available for the regional, national and international structural biology user community. The state-of-the-art synchrotron beamlines for MX BL14.1, BL14.2 and BL14.3 are located within the low-ß section of the BESSY II electron storage ring. All beamlines are fed from a superconducting 7 T wavelength-shifter insertion device. BL14.1 and BL14.2 are energy tunable in the range 5-16 keV, while BL14.3 is a fixed-energy side station operated at 13.8 keV. All three beamlines are equipped with CCD detectors. BL14.1 and BL14.2 are in regular user operation providing about 200 beam days per year and about 600 user shifts to approximately 50 research groups across Europe. BL14.3 has initially been used as a test facility and was brought into regular user mode operation during the year 2010. BL14.1 has recently been upgraded with a microdiffractometer including a mini-κ goniometer and an automated sample changer. Additional user facilities include office space adjacent to the beamlines, a sample preparation laboratory, a biology laboratory (safety level 1) and high-end computing resources. In this article the instrumentation of the beamlines is described, and a summary of the experimental possibilities of the beamlines and the provided ancillary equipment for the user community is given.


Subject(s)
Crystallography, X-Ray , Genomics/methods , Macromolecular Substances/chemistry , Synchrotrons/instrumentation , Animals , Automation, Laboratory , Hydrolases/chemistry , Mice , Opsins/chemistry , Orosomucoid/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...