1.
Breast Care (Basel) ; 19(2): 87-94, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38765898

ABSTRACT

Introduction: Pre-therapeutic histologic diagnosis through image-guided core needle biopsy (CNB) or vacuum-assisted biopsy (VAB) for suspicious breast findings is a standard procedure. Despite the moderate risk of bleeding, a significant proportion of patients are on temporary or permanent anti-coagulation therapy (ACT) or anti-platelet therapy (APT). Currently, there are no established guidelines for managing biopsies in such patients, leading to varying approaches in clinical practice. Methods: An online survey was conducted among all members of the breast ultrasound working group at the German Society for Ultrasound in Medicine (DEGUM) and the working group for breast diagnostics at the German Radiology Society (DRG). It included n = 51 questions about individual risk perception of biopsy-related bleeding complications and the specific management of biopsies on ACT/APT. Results: A total of 332 experts participated, with 51.8% reporting the absence of a standardized management plan for breast biopsies on ACT/APT. Concerning specific ACT/APT medications, the survey revealed discrepancies in risk perception and management: The majority preferred discontinuing medication with directly acting oral anti-coagulants (DOACs; CNB: 66.9%; VAB: 91.1%), phenprocoumon (CNB: 74.9%; VAB: 96.7%), or therapeutic heparin (CNB: 46.1%; VAB: 72.7%). However, there was a lower inclination to discontinue acetylsalicylic acid (ASA; CNB: 15.2%; VAB: 50.3%) or prophylactic heparin (CNB: 11.9%, VAB: 36.3%). Conclusion: Breast biopsies for patients on ASA or prophylactic heparin are deemed safe and part of standard clinical practice. However, despite available feasibility studies, conducting breast biopsies on ACT medications such as DOACs or phenprocoumon appears feasible only for a minority of experts.

2.
Arch Gynecol Obstet ; 309(6): 2771-2778, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38625545

ABSTRACT

PURPOSE: The primary objective of this study was to establish a benchmark by collecting baseline data on surgical education in obstetrics and gynecology in Germany, including factual number of operations performed. MATERIALS AND METHODS: A nationwide anonymous survey was conducted in Germany between January 2019 and July 2019 utilizing a specially designed questionnaire which addressed both residents and senior trainers. RESULTS: A total of 601 participants completed the survey, comprising 305 trainees and 296 trainers. The trainees reported performing a median of 125 non-obstetric surgeries (IQR: 41-332) and 75 obstetric procedures (IQR: 27-168) independently. While most last-year residents managed to meet the targeted numbers for minor surgical procedures outlined in the logbook, they fell short of achieving the required numbers for major operations, such as hysterectomies or more complex laparoscopies. Although both trainees and trainers emphasized the significance of surgical training, the overall quality of the training was rated poorly, particularly by trainees. This was attributed to a high proportion of administrative tasks and a deficiency in teaching time within the operating theater. External fellowship and mentoring programs, as well as the implementation of regular, centralized reviews of residency training, were identified as potentially beneficial by both trainees and trainers. CONCLUSION: The findings of this survey should serve as a wake-up call both within and outside of Germany, highlighting the importance of comprehensive and structured surgical training to enhance long-term patient care and increase satisfaction among obstetrics and gynecology trainees.


Subject(s)
Gynecology , Internship and Residency , Obstetrics , Humans , Obstetrics/education , Germany , Internship and Residency/statistics & numerical data , Gynecology/education , Female , Surveys and Questionnaires , Male , Adult , Gynecologic Surgical Procedures/education , Gynecologic Surgical Procedures/statistics & numerical data , Clinical Competence/statistics & numerical data , Middle Aged
3.
Cancers (Basel) ; 16(2)2024 Jan 07.
Article in English | MEDLINE | ID: mdl-38254756

ABSTRACT

Our study aims to identify the risk factors and dosimetry characteristics associated with capsular contracture. METHODS: We retrospectively analyzed 118 women with breast cancer who underwent PMRT following an IBR between 2010 and 2022. Patients were treated with PMRT of 50.0-50.4 Gy in 25-28 fractions. Capsular contracture was categorized according to the Baker Classification for Reconstructed Breasts. RESULTS: After a median follow-up of 22 months, the incidence of clinically relevant capsular contracture (Baker III-IV) was 22.9%. Overall, capsular contracture (Baker I-IV) occurred in 56 patients (47.5%) after a median of 9 months after PMRT. The rate of reconstruction failure/implant loss was 25.4%. In the univariate analysis, postoperative complications (prolonged pain, prolonged wound healing, seroma and swelling) and regional nodal involvement were associated with higher rates of capsular contracture (p = 0.017, OR: 2.5, 95% CI: 1.2-5.3 and p = 0.031, respectively). None of the analyzed dosimetric factors or the implant position were associated with a higher risk for capsular contracture. CONCLUSION: Postoperative complications and regional nodal involvement were associated with an increased risk of capsular contracture following breast reconstruction and PMRT, while none of the analyzed dosimetric factors were linked to a higher incidence. Additional studies are needed to identify further potential risk factors.

4.
J Ultrasound Med ; 43(1): 109-114, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37772458

ABSTRACT

OBJECTIVES: Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra- and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4. METHODS: We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra- and interobserver reliability. RESULTS: ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopathologically benign or malignant lesions. CONCLUSION: Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.


Subject(s)
Breast Neoplasms , Elasticity Imaging Techniques , Humans , Female , Male , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Ultrasonography, Mammary , Prospective Studies , Reproducibility of Results , Breast/diagnostic imaging , Breast/pathology , Sensitivity and Specificity , Diagnosis, Differential
5.
Breast Cancer Res Treat ; 201(1): 57-66, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37302085

ABSTRACT

PURPOSE: A previous study in our breast unit showed that the diagnostic accuracy of intraoperative specimen radiography and its potential to reduce second surgeries in a cohort of patients treated with neoadjuvant chemotherapy were low, which questions the routine use of Conventional specimen radiography (CSR) in this patient group. This is a follow-up study in a larger cohort to further evaluate these findings. METHODS: This retrospective study included 376 cases receiving breast-conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. CSR was performed to assess potential margin infiltration and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. RESULTS: 362 patients with 2172 margins were assessed. The prevalence of positive margins was 102/2172 (4.7%). CSR had a sensitivity of 37.3%, a specificity of 85.6%, a positive predictive value (PPV) of 11.3%, and a negative predictive value (NPV) of 96.5%. The rate of secondary procedures was reduced from 75 to 37 with a number needed to treat (NNT) of CSR-guided intraoperative re-excisions of 10. In the subgroup of patients with clinical complete response (cCR), the prevalence of positive margins was 38/1002 (3.8%), PPV was 6.5% and the NNT was 34. CONCLUSION: This study confirms our previous finding that the rate of secondary surgeries cannot be significantly reduced by CSR-guided intraoperative re-excisions in cases with cCR after NACT. The routine use CSR after NACT is questionable, and alternative tools of intraoperative margin assessment should be evaluated.


Subject(s)
Breast Neoplasms , Carcinoma, Ductal, Breast , Humans , Female , Neoadjuvant Therapy/methods , Follow-Up Studies , Retrospective Studies , Carcinoma, Ductal, Breast/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Breast Neoplasms/surgery , Mastectomy, Segmental/methods , Margins of Excision , Radiography
6.
Int J Radiat Oncol Biol Phys ; 117(4): 857-868, 2023 Nov 15.
Article in English | MEDLINE | ID: mdl-37244626

ABSTRACT

PURPOSE: The IMRT-MC2 trial was conducted to demonstrate the noninferiority of conventionally fractionated intensity modulated radiation therapy with a simultaneous integrated boost to 3-dimensional conformal radiation therapy with a sequential boost for adjuvant breast radiation therapy. METHODS AND MATERIALS: A total of 502 patients were randomized between 2011 and 2015 for the prospective, multicenter, phase III trial (NCT01322854). Five-year results of late toxicity (late effects normal tissue task force-subjective, objective, management, and analytical), overall survival, disease-free survival, distant disease-free survival, cosmesis (Harvard scale), and local control (noninferiority margin at hazard ratio [HR] of 3.5) were analyzed after a median follow-up of 62 months. RESULTS: The 5-year local control rate for the intensity modulated radiation therapy with simultaneous integrated boost arm was non-inferior to the control arm (98.7% vs 98.3%, respectively; HR, 0.582; 95% CI, 0.119-2.375; P = .4595). Furthermore, there was no significant difference in overall survival (97.1% vs 98.3%, respectively; HR, 1.235; 95% CI, 0.472-3.413; P = .6697), disease-free survival (95.8% vs 96.1%, respectively; HR, 1.130; 95% CI, 0.487-2.679; P = .7758), and distant disease-free survival (97.0% vs 97.8%, respectively; HR, 1.667; 95% CI, 0.575-5.434; P = .3601). After 5 years, late toxicity evaluation and cosmetic assessment further showed no significant differences between treatment arms. CONCLUSIONS: The 5-year results of the IMRT-MC2 trial provide strong evidence that the application of conventionally fractionated simultaneous integrated boost irradiation for patients with breast cancer is both safe and effective, with noninferior local control compared with 3-dimensional conformal radiation therapy with sequential boost.

7.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36789976

ABSTRACT

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Subject(s)
Breast Neoplasms , Elasticity Imaging Techniques , Humans , Female , Sensitivity and Specificity , Elasticity Imaging Techniques/methods , Ultrasonography, Mammary/methods , Reproducibility of Results , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Biopsy , Elasticity , Diagnosis, Differential
8.
Breast ; 68: 194-200, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36842192

ABSTRACT

PURPOSE: The Histolog® Scanner (SamanTree Medical SA, Lausanne, Switzerland) is a large field-of-view confocal laser scanning microscope designed to allow intraoperative margin assessment by the production of histological images ready for assessment in the operating room. We evaluated the feasibility and the performance of the Histolog® Scanner (HS) to correctly identify infiltrated margins in clinical practice of lumpectomy specimens. It was extrapolated if the utilization of the HS has the potential to reduce infiltrated margins and therefore reduce re-operation rates in patients undergoing breast conserving surgery (BCS) due to a primarily diagnosed breast cancer including ductal carcinoma in situ. METHODS: This is a single-center, prospective, non-interventional, diagnostic pilot study including 50 consecutive patients receiving BCS. The complete surface of the specimen was scanned using the HS intraoperatively. The surgery and the intraoperative margin assessment of the specimen was performed according to the clinical routine consisting of conventional specimen radiography as well as the clinical impression of the surgeon. Three surgeons and an experienced pathologist assessed the scans produced by the HS for cancer cells on the surface. The potential of the HS to correctly identify involved margins was compared to the results of the conventional specimen radiography alone as well as the clinical routine. The histopathological report served as the gold standard. RESULTS: 50 specimens corresponding to 300 surfaces were scanned by the HS. The mean sensitivity of the surgeons to identify involved margins with the HS was 37.5% ± 5.6%, the specificity was 75.2% ± 13.0%. The assessment of resection margins by the pathologist resulted in a sensitivity of 37.5% and a specificity of 81.0%, while the local clinical routine resulted in a sensitivity of 37.5% and a specificity of 78.2%. CONCLUSION: Acquisition of high-resolution histological images using the HS was feasible in clinical practice. Sensitivity and specificity were comparable to clinical routine. With more specific training and experience on image interpretation and acquisition, the HS may have the potential to enable more accuracy in the margin assessment of BCS specimens.


Subject(s)
Breast Neoplasms , Carcinoma, Ductal, Breast , Humans , Female , Mastectomy, Segmental/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Ductal, Breast/surgery , Carcinoma, Ductal, Breast/pathology , Prospective Studies , Pilot Projects , Margins of Excision , Radiography , Microscopy, Confocal
9.
Arch Gynecol Obstet ; 308(1): 219-229, 2023 07.
Article in English | MEDLINE | ID: mdl-36604331

ABSTRACT

PURPOSE: Today, the decision to treat patients with chemotherapy for early breast cancer (EBC) is made based on the patient's individual risk stratification and tumor biology. In cases with chemotherapy indication, the neoadjuvant application (NACT) is the preferred option in comparison with primary surgery and adjuvant chemotherapy (ACT). Age remains a relevant factor in the decision-making process. The aim of the present study was to illustrate the impact of age on the use of systemic therapy in clinical routine. METHODS: The study separately analyzed chemotherapy use among six age cohorts of EBC patients who had been treated at 104 German breast units between January 2008 and December 2017. RESULTS: In total, 124,084 patients were included, 46,279 (37.3%) of whom had received chemotherapy. For 44,765 of these cases, detailed information on treatment was available. Within this cohort, chemotherapy was administered as NACT to 14,783 patients (33.0%) and as ACT to 29,982 (67.0%) patients. Due to the higher prevalence of unfavorable tumor subtypes, younger patients had a higher rate of chemotherapy (≤ 29y: 74.2%; 30-39y: 71.3%) and a higher proportion of NACT administration ( ≤ 29y: 66.9%; 30-39y: 56.0%) in comparison with elderly patients, who had lower rates for overall chemotherapy (60-69y: 37.5%; ≥ 70y: 17.6%) and NACT (60-69y: 25.5%; ≥ 70y: 22.8%). Pathologic complete response was higher in younger than in older patients (≤ 29y: 30.4% vs. ≥ 70y: 16.7%), especially for HER2- subtypes. CONCLUSION: The data from the nationwide German cohort reveal relevant age-dependent discrepancies concerning the use of chemotherapy for EBC.


Subject(s)
Breast Neoplasms , Humans , Aged , Female , Breast Neoplasms/pathology , Chemotherapy, Adjuvant , Neoadjuvant Therapy/methods , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Antineoplastic Combined Chemotherapy Protocols/adverse effects
10.
Appl Health Econ Health Policy ; 21(2): 275-287, 2023 03.
Article in English | MEDLINE | ID: mdl-36409454

ABSTRACT

BACKGROUND: The American College of Surgeons Oncology Group Z0011 trial showed that complete axillary lymph node dissection (cALND) did not improve survival benefits in patients with one or two tumour-involved sentinel lymph nodes and undergoing breast conservation. Still, a considerable number of the Z0011-eligible patients continue to be treated with cALND in various countries. Given the potential economic gain from implementation of the Z0011 recommendations, we quantified population-level impacts of omitting cALND among Z0011-eligible patients in clinical practice. METHODS: This 2-year economic analysis adopted both the perspective of patients under statutory insurance and the societal perspective, using data collected prospectively from 179 German breast cancer units between 2008 and 2015. The estimation of cost savings and health gain relied on a single decision tree, which considered three scenarios: clinical practice at the baseline; actual implementation in routine care; and hypothetical full implementation in all eligible patients. RESULTS: Data for 188,909 patients with primary breast cancer were available, 13,741 (7.3%) of whom met the Z0011 inclusion criteria. The use of cALND decreased from 94.3% in 2010 to 46.9% in 2015, resulting in a gain of 335 quality-adjusted life-years and a saving of EUR50,334,756 for the society. Had cALND been omitted in all eligible patients, the total gain would have been more than double. CONCLUSIONS: The implementation of the Z0011 recommendations resulted in substantial savings and health gain in Germany. Our findings suggest that it is beneficial to introduce additional policy measures to promote further uptake of the Z0011 recommendations in clinical practice.


Subject(s)
Breast Neoplasms , Female , Humans , Breast Neoplasms/pathology , Sentinel Lymph Node Biopsy , Lymphatic Metastasis , Cost-Benefit Analysis , Lymph Node Excision , Germany
11.
Arch Gynecol Obstet ; 307(4): 1105-1113, 2023 04.
Article in English | MEDLINE | ID: mdl-35980458

ABSTRACT

PURPOSE: Breast cancer (BC) is the most common malignancy among women and prognosis is strongly influenced by tumor subtype. Neoadjuvant chemotherapy (NAC) is the standard treatment for both locally advanced- and early-stage triple-negative and Her2-positive BC. Pathologic complete response (pCR) to NAC is an important predictor of patient outcomes. Neutrophil-to-lymphocyte-ratio (NLR) in peripheral blood is associated with prognosis in various malignancies. Here, we investigated the value of the pretreatment NLR as a response predictor in neoadjuvant-treated patients with BC. METHODS: A retrospective chart analysis of 862 patients with invasive BC treated with NAC at the Heidelberg University Hospital during 2003-2015 was conducted. NLR was calculated as the ratio of the absolute neutrophil and lymphocyte counts in peripheral blood, and pCR was defined as absence of invasive or in situ carcinoma in breast and axillary lymph nodes. RESULTS: A total of 151 patients with invasive BC who underwent NAC were included in this study. NLR tended to be higher in the pCR group than the non-pCR group (p < 0.1). Analyses of BC subtypes demonstrated that NLR was significantly higher in the pCR- compared with the non-pCR group (3.304 vs. 2.379, respectively; p = 0.048) in patients with luminal B/Her2-negative tumors. Further, we found a significant difference in NLR according to remission status in postmenopausal patients (2.861 vs. 2.313, respectively; p = 0.043). CONCLUSION: NLR was significantly higher only for patients achieving pCR in the Luminal B/Her2-negative and postmenopausal subgroups. Hence, NLR is a candidate additional predictive factor in patients with Luminal B/Her2-negative BC.


Subject(s)
Breast Neoplasms , Humans , Female , Breast Neoplasms/drug therapy , Breast Neoplasms/pathology , Neutrophils/pathology , Neoadjuvant Therapy , Retrospective Studies , Lymphocytes/pathology , Prognosis , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Receptor, ErbB-2
12.
Eur J Cancer ; 177: 1-14, 2022 12.
Article in English | MEDLINE | ID: mdl-36283244

ABSTRACT

BACKGROUND: Breast ultrasound identifies additional carcinomas not detected in mammography but has a higher rate of false-positive findings. We evaluated whether use of intelligent multi-modal shear wave elastography (SWE) can reduce the number of unnecessary biopsies without impairing the breast cancer detection rate. METHODS: We trained, tested, and validated machine learning algorithms using SWE, clinical, and patient information to classify breast masses. We used data from 857 women who underwent B-mode breast ultrasound, SWE, and subsequent histopathologic evaluation at 12 study sites in seven countries from 2016 to 2019. Algorithms were trained and tested on data from 11 of the 12 sites and externally validated using the additional site's data. We compared findings to the histopathologic evaluation and compared the diagnostic performance between B-mode breast ultrasound, traditional SWE, and intelligent multi-modal SWE. RESULTS: In the external validation set (n = 285), intelligent multi-modal SWE showed a sensitivity of 100% (95% CI, 97.1-100%, 126 of 126), a specificity of 50.3% (95% CI, 42.3-58.3%, 80 of 159), and an area under the curve of 0.93 (95% CI, 0.90-0.96). Diagnostic performance was significantly higher compared to traditional SWE and B-mode breast ultrasound (P < 0.001). Unlike traditional SWE, positive-predictive values of intelligent multi-modal SWE were significantly higher compared to B-mode breast ultrasound. Unnecessary biopsies were reduced by 50.3% (79 versus 159, P < 0.001) without missing cancer compared to B-mode ultrasound. CONCLUSION: The majority of unnecessary breast biopsies might be safely avoided by using intelligent multi-modal SWE. These results may be helpful to reduce diagnostic burden for patients, providers, and healthcare systems.


Subject(s)
Breast Neoplasms , Elasticity Imaging Techniques , Humans , Female , Elasticity Imaging Techniques/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Retrospective Studies , Ultrasonography, Mammary , Biopsy , Sensitivity and Specificity , Reproducibility of Results , Diagnosis, Differential
13.
PLoS One ; 17(8): e0269562, 2022.
Article in English | MEDLINE | ID: mdl-35930549

ABSTRACT

PURPOSE: The COVID-19 pandemic has imposed severe challenges on medical education at German university hospitals. In this first German nationwide expert survey, we addressed the responsible university teaching coordinators in obstetrics and gynecology departments and investigated their experiences during the pandemic as well as their opinions on future developments, especially with regard to the broader implementation of e-learning in the standard curriculum. METHODS: The questionnaire included 42 items and was disseminated among teaching coordinators at all 41 departments of obstetrics and gynecology at German university hospitals via an email that included a weblink to the online survey provider. Responses were collected between 19 April and 7 June 2021. RESULTS: In total, 30 responses were collected from 41 departments across Germany and their respective teaching coordinators in obstetrics and gynecology. The general opinion of the medical teaching provided during the pandemic was positive, whereas the teaching quality in practical skills was considered inferior and not equivalent to the standard face-to-face curriculum. Lectures and seminars had to be substituted by remote-learning alternatives, while clinical clerkships were reduced in length and provided less patient contact. Students in their final year experienced only a few differences in the clinical and teaching routine. Teaching coordinators in obstetrics and gynecology stated that they intend to incorporate more e-learning into the curriculum in the future. CONCLUSION: The medical educators' views presented here may help to complement the already-thoroughly investigated experiences of students under the restrictions of the COVID-19 pandemic. Medical educators in obstetrics and gynecology at German university hospitals have successfully established online and hybrid teaching alternatives to their standard face-to-face courses. Building on recent experiences, digitalization could help to improve future medical education.


Subject(s)
COVID-19 , Education, Medical, Undergraduate , Education, Medical , Gynecology , Obstetrics , Students, Medical , COVID-19/epidemiology , Female , Gynecology/education , Hospitals, University , Humans , Obstetrics/education , Pandemics , Pregnancy , Surveys and Questionnaires , Teaching
14.
Br J Radiol ; 95(1139): 20220372, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36000742

ABSTRACT

OBJECTIVES: To define reference values for shear wave elastography (SWE) in unsuspicious axillary lymph nodes in patients undergoing breast ultrasound examination. METHODS: In total, 177 clinically and sonographically unsuspicious axillary lymph nodes were prospectively evaluated with SWE using Virtual Touch Tissue Imaging Quantification (VTIQ) in 175 women. Mean values of tissue stiffness for axillary fatty tissue, lymph node cortex, and lymph node hilus were measured. Additionally, test-retest reliability of SWE in the assessment of axillary lymph node stiffness was evaluated by repeating each measurement three times. RESULTS: In 177 axillary lymph nodes, the mean stiffness of lymph node cortex, hilus, and surrounding fatty tissue as quantified by SWE was 1.90 m/s (SD: 0.34 m/s), 2.02 m/s (SD: 0.37 m/s), and 1.75 m/s (SD: 0.38 m/s), respectively. The mean stiffness of cortex and hilus was significantly higher compared to fatty tissue (p < 0.0001). SWE demonstrated good test-retest reliability in the assessment of stiffness of the lymph node hilus, cortex, and the surrounding fatty tissue with an intraclass correlation of 0.79 (95% CI: 0.75; 0.83), 0.75 (95% CI: 0.70; 0.79), and 0.78 (95% CI: 0.74; 0.82), respectively, (p < 0.0001). CONCLUSIONS: Reference values for SWE in unsuspicious axillary lymph nodes are determined. These results may help to better identify axillary lymph node metastasis for breast cancer patients when combined with other lymph node features. SWE is a reliable method for the objective quantification of tissue stiffness of axillary lymph nodes. ADVANCES IN KNOWLEDGE: This study presents physiological reference values for tissue stiffness by examining the axillary lymph nodes with SWE in 175 women with sonomorphologically unsuspicious lymph nodes.


Subject(s)
Breast Neoplasms , Elasticity Imaging Techniques , Humans , Female , Elasticity Imaging Techniques/methods , Reproducibility of Results , Ultrasonography, Mammary/methods , Axilla/pathology , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology
15.
Arch Gynecol Obstet ; 306(5): 1587-1596, 2022 11.
Article in English | MEDLINE | ID: mdl-35852646

ABSTRACT

PURPOSE: The aim of this study was to investigate whether students' attitude towards online learning in Gynecology and Obstetrics changed during the COVID-19 pandemic. We further examined which variables impacted students' satisfaction with digital learning. METHODS: A specifically developed questionnaire was used from June 2020-July 2021 for N = 234 medical students participating in the course "Gynecology and Obstetrics" at University of Heidelberg. Thirty-five items were repeatedly applied in different cohorts to assess structure- and content-related quality of teaching. In addition, their influence on overall satisfaction with digital teaching was analyzed by applying investigative analyses like multiple regression and extreme group comparisons. RESULTS: Especially items associated with content-related quality of teaching (ß = 0.24), organization of teaching (ß = 0.25) and subjective learning success (ß = 0.27) seemed to be relevant predictors for overall satisfaction with courses. Fears and changes due to the pandemic situation also played a role for a subgroup of students. Aspects linked to technical quality of teaching, interactions with teachers and students or advantages of web-based learning appeared to play a subordinate role for overall satisfaction with digital teaching. Comparisons of ratings over time revealed that teaching evaluations almost remained the same. CONCLUSION: Our results give several hints regarding how digital teaching should be designed and how it can be improved. Further studies are needed to validate our results and to develop methods to improve digital teaching in medicine.


Subject(s)
COVID-19 , Gynecology , Obstetrics , Students, Medical , Female , Gynecology/education , Humans , Obstetrics/education , Pandemics , Personal Satisfaction , Pregnancy , Teaching
16.
Cancers (Basel) ; 14(12)2022 Jun 18.
Article in English | MEDLINE | ID: mdl-35740675

ABSTRACT

The present analysis compares the esthetics assessment by the BCCT.core software in relation to patients' and physicians' ratings, based on the IMRT-MC2 trial. Within this trial, breast cancer patients received breast-conserving surgery (BCS) and adjuvant radiotherapy. At the baseline, 6 weeks, and 2 years after radiotherapy, photos of the breasts were assessed by the software and patients' and physicians' assessments were performed. Agreement rates of the assessments and their correlation with breast asymmetry indices were evaluated. The assessments of the software and the physicians were significantly correlated with asymmetry indices. Before and 6 weeks after radiotherapy, the patients' self-assessment was only correlated with the lower breast contour (LBC) and upward nipple retraction (UNR), while after 2 years, there was also a correlation with other indices. Only a slight agreement between the BCCT.core software and the physicians' or patients' assessment was seen, while a moderate and substantial agreement was detected between the physicians' and the patients' assessment after 6 weeks and 2 years, respectively. The BCCT.core software is a reliable tool to measure asymmetries, but may not sufficiently evaluate the esthetic outcome as perceived by patients. It may be more appropriate for a long-term follow-up, when symmetry appears to increase in importance.

17.
Eur Radiol ; 32(6): 4101-4115, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35175381

ABSTRACT

OBJECTIVES: AI-based algorithms for medical image analysis showed comparable performance to human image readers. However, in practice, diagnoses are made using multiple imaging modalities alongside other data sources. We determined the importance of this multi-modal information and compared the diagnostic performance of routine breast cancer diagnosis to breast ultrasound interpretations by humans or AI-based algorithms. METHODS: Patients were recruited as part of a multicenter trial (NCT02638935). The trial enrolled 1288 women undergoing routine breast cancer diagnosis (multi-modal imaging, demographic, and clinical information). Three physicians specialized in ultrasound diagnosis performed a second read of all ultrasound images. We used data from 11 of 12 study sites to develop two machine learning (ML) algorithms using unimodal information (ultrasound features generated by the ultrasound experts) to classify breast masses which were validated on the remaining study site. The same ML algorithms were subsequently developed and validated on multi-modal information (clinical and demographic information plus ultrasound features). We assessed performance using area under the curve (AUC). RESULTS: Of 1288 breast masses, 368 (28.6%) were histopathologically malignant. In the external validation set (n = 373), the performance of the two unimodal ultrasound ML algorithms (AUC 0.83 and 0.82) was commensurate with performance of the human ultrasound experts (AUC 0.82 to 0.84; p for all comparisons > 0.05). The multi-modal ultrasound ML algorithms performed significantly better (AUC 0.90 and 0.89) but were statistically inferior to routine breast cancer diagnosis (AUC 0.95, p for all comparisons ≤ 0.05). CONCLUSIONS: The performance of humans and AI-based algorithms improves with multi-modal information. KEY POINTS: • The performance of humans and AI-based algorithms improves with multi-modal information. • Multimodal AI-based algorithms do not necessarily outperform expert humans. • Unimodal AI-based algorithms do not represent optimal performance to classify breast masses.


Subject(s)
Artificial Intelligence , Breast Neoplasms , Algorithms , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Female , Humans , Multimodal Imaging
18.
Arch Gynecol Obstet ; 305(1): 129-137, 2022 01.
Article in English | MEDLINE | ID: mdl-34550446

ABSTRACT

PURPOSE: The field of obstetrics and gynecology (OB/GYN) is facing growing competition for young professionals in Germany, with high interest rates among female graduates and a declining proportion of male students who choose residency training in the field. The aim of this study is to analyze general and gender-dependent factors that influence the decision for or against specialty training in OB/GYN among medical students in Germany. METHODS: Between February and November 2019, n = 346 medical students in their 5th and 6th year of undergraduate training at Heidelberg University received a questionnaire with 44 items. RESULTS: n = 286 students (61.3 female; 38.7% male) participated in the study. 28% of the female students and 9% of the male students had considered OB/GYN for their specialty training. The students reported different general and gender-specific influencing factors in their choice of a specialty. Both genders desired a good work-life-balance, however, in comparison with their female colleagues, male students had heavily weighted factors related to their later careers and professional success, including competition among colleagues. Male students had gained little practical experience during compulsory internships (26.9% for females vs. 8.8% for males) or had chosen their final-year elective in OB/GYN (15.9% for females vs. 5.5% for males). Female students had worried about the negative effects of their sex on their career (35.4% for females vs. 5.9% for males). CONCLUSION: OB/GYN must become more appealing and attractive to young female and male professionals alike. A better compatibility of career and family should go hand in hand with the implementation of differentiated, (extra) curricular teaching approaches that take the different preferences of female and male students into account.


Subject(s)
Gynecology , Internship and Residency , Obstetrics , Students, Medical , Female , Germany , Gynecology/education , Humans , Male , Obstetrics/education , Pregnancy , Surveys and Questionnaires
19.
J Ultrasound Med ; 41(2): 427-436, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33942358

ABSTRACT

OBJECTIVES: The BI-RADS classification provides a standardized way to describe ultrasound findings in breast cancer diagnostics. However, there is little information regarding which BI-RADS descriptors are most strongly associated with malignancy, to better distinguish BI-RADS 3 (follow-up imaging) and 4 (diagnostic biopsy) breast masses. METHODS: Patients were recruited as part of an international, multicenter trial (NCT02638935). The trial enrolled 1294 women (6 excluded) categorized as BI-RADS 3 or 4 upon routine B-mode ultrasound examination. Ultrasound images were evaluated by three expert physicians according to BI-RADS. All patients underwent histopathological confirmation (reference standard). We performed univariate and multivariate analyses (chi-square test, logistic regression, and Krippendorff's alpha). RESULTS: Histopathologic evaluation showed malignancy in 368 of 1288 masses (28.6%). Upon performing multivariate analysis, the following descriptors were significantly associated with malignancy (P < .05): age ≥50 years (OR 8.99), non-circumscribed indistinct (OR 4.05) and microlobulated margin (OR 2.95), nonparallel orientation (OR 2.69), and calcification (OR 2.64). A clinical decision rule informed by these results demonstrated a 97% sensitivity and missed fewer cancers compared to three physician experts (range of sensitivity 79-95%) and a previous decision rule (sensitivity 59%). Specificity was 44% versus 22-83%, respectively. The inter-reader reliability of the BI-RADS descriptors and of the final BI-RADS score was fair-moderate. CONCLUSIONS: A patient should undergo a diagnostic biopsy (BI-RADS 4) instead of follow-up imaging (BI-RADS 3) if the patient is 50 years or older or exhibits at least one of the following features: calcification, nonparallel orientation of mass, non-circumscribed margin, or posterior shadowing.


Subject(s)
Breast Neoplasms , Ultrasonography, Mammary , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Female , Humans , Middle Aged , Reproducibility of Results , Retrospective Studies , Ultrasonography
20.
Breast Cancer Res Treat ; 191(3): 589-598, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34878635

ABSTRACT

PURPOSE: This is the first study to systematically evaluate the diagnostic accuracy of intraoperative specimen radiography on margin level and its potential to reduce second surgeries in patients treated with neoadjuvant chemotherapy. METHODS: This retrospective study included 174 cases receiving breast conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. Conventional specimen radiography (CSR) was performed to assess potential margin infiltration and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. RESULTS: 1044 margins were assessed. Of 47 (4.5%) histopathological positive margins, CSR identified 9 correctly (true positive). 38 infiltrated margins were missed (false negative). This resulted in a sensitivity of 19.2%, a specificity of 89.2%, a positive predictive value (PPV) of 7.7%, and a negative predictive value (NPV) of 95.9%. The rate of secondary procedures was reduced from 23 to 16 with a number needed to treat (NNT) of CSR-guided intraoperative re-excisions of 25. In the subgroup of patients with cCR, the prevalence of positive margins was 10/510 (2.0%), PPV was 1.9%, and the NNT was 85. CONCLUSION: Positive margins after NACT are rare and CSR has only a low sensitivity to detect them. Thus, the rate of secondary surgeries cannot be significantly reduced by recommending targeted re-excisions, especially in cases with cCR. In summary, CSR after NACT is inadequate for intraoperative margin assessment but remains useful to document removal of the biopsy site clip.


Subject(s)
Breast Neoplasms , Carcinoma, Ductal, Breast , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/surgery , Female , Humans , Mastectomy, Segmental , Neoadjuvant Therapy , Radiography , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...