Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters











Database
Language
Publication year range
1.
World J Pediatr Congenit Heart Surg ; 12(1): 17-26, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33407028

ABSTRACT

BACKGROUND: To assess changes in patterns of practice and outcomes over time, we reviewed all patients who underwent heart transplantation (HTx) at our institution and compared two consecutive eras with significantly different immunosuppressive protocols (cohort 1 [80 HTx, June 1995-June 2006]; cohort 2 [108 HTx, July 2006-September 2018]). METHODS: Retrospective study of 180 patients undergoing 188 HTx (June 1995-September 2018; 176 first time HTx, 10 second HTx, and 2 third HTx). In 2006, we commenced pre-HTx desensitization for highly sensitized patients and started using tacrolimus as our primary postoperative immunosuppressive agent. The primary outcome was mortality. Survival was modeled by the Kaplan-Meier method. Univariable and multivariable Cox proportional hazard models were created to identify prognostic factors for survival. RESULTS: Our 188 HTx included 18 neonates, 85 infants, 83 children, and 2 adults (>18 years). Median age was 260.0 days (range: 5 days-23.8 years). Median weight was 7.5 kg (range: 2.2-113 kg). Patients in cohort 1 were less likely to have been immunosensitized preoperatively (12.5% vs 28.7%, P = .017). Nevertheless, Kaplan-Meier analysis suggested superior survival in cohort 2 (P = .0045). Patients in cohort 2 were more likely to be alive one year, five years, and ten years after HTx. Multivariable analysis identified the earlier era (hazard ratio [HR] [95% confidence interval] for recent era = 0.32 [0.14-0.73]), transplantation after prior Norwood operation (HR = 4.44 [1.46-13.46]), and number of prior cardiac operations (HR = 1.33 [1.03-1.71]) as risk factors for mortality. CONCLUSIONS: Our analysis of 23 years of pediatric and congenital HTx reveals superior survival in the most recent 12-year era, despite the higher proportion of patients with elevated panel reactive antibody in the most recent era. This improvement was temporally associated with changes in our immunosuppressive strategy.


Subject(s)
Heart Defects, Congenital/surgery , Heart Transplantation/methods , Norwood Procedures/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Retrospective Studies , Risk Factors , Treatment Outcome , Young Adult
2.
Cardiol Young ; 30(11): 1730-1731, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33203499

ABSTRACT

Anomalous circumflex coronary artery origin from pulmonary artery is a very rare congenital heart disease. Misdiagnosis of this condition may lead to inadequate myocardial protection during cardiopulmonary bypass surgery.


Subject(s)
Coronary Artery Disease , Coronary Vessel Anomalies , Coronary Angiography , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/surgery , Humans , Pulmonary Artery/diagnostic imaging
3.
Pediatr Cardiol ; 40(7): 1523-1529, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31375852

ABSTRACT

Acute femoral artery occlusion is common in pediatric patients following cardiac catheterization. A variety of means are utilized to assess lower extremity (LE) perfusion and arterial patency following cardiac catheterization including palpation of pulses, pulse oximetry, subjective assessment of lower extremity color and temperature, and ultrasound. We sought to evaluate the utility of Near-Infrared Spectroscopy (NIRS) to monitor LE perfusion in pediatric patients undergoing cardiac catheterization. INVOS pediatric sensors were placed on bilateral LE in all pediatric patients ≤ 40 kg undergoing cardiac catheterization. Data were recorded continuously from the start of the procedure until 4-6 h after completion of the procedure. NIRS readings were compared between the accessed versus non-accessed LE at baseline before start of case, time of vascular access, arterial sheath exchange when applicable, sheath withdrawal, and Safeguard application, deflation, and removal. 133 patients underwent 152 catheterizations with mean age 2.4 ± 2.3 years and mean weight 12.4 ± 13.2 kg. NIRS oximetry readings were significantly decreased in the LE with arterial access compared to non-accessed LE from time of sheath insertion until removal of the pressure assist device post procedure. A greater difference was noted in smaller patients. NIRS oximetry readings did not correlate with subjective assessment of lower extremity perfusion after arterial sheaths were removed. One patient had pulse loss 4 h post procedure with a decrease in oximetry readings noted at this point on review. Weight-based heparin protocol was initiated, and a gradual improvement in oximetry readings was noted over the next 5 h. Vascular ultrasound 12 h later showed no evidence of arterial thrombus. NIRS may be helpful in identifying patients who are risk for developing arterial thrombus post cardiac catheterization and for monitoring response to therapy; however, further study in these patients is warranted.


Subject(s)
Cardiac Catheterization/adverse effects , Lower Extremity/blood supply , Spectroscopy, Near-Infrared/methods , Arterial Occlusive Diseases/diagnosis , Brain/blood supply , Child, Preschool , Female , Humans , Infant , Male , Oximetry/methods , Thrombosis/etiology , Thrombosis/prevention & control , Ultrasonography, Doppler
4.
Pediatr Crit Care Med ; 20(8): 728-736, 2019 08.
Article in English | MEDLINE | ID: mdl-30985609

ABSTRACT

OBJECTIVES: To assess the variation in timing of left atrial decompression and its association with clinical outcomes in pediatric patients supported with venoarterial extracorporeal membrane oxygenation across a multicenter cohort. DESIGN: Multicenter retrospective study. SETTING: Eleven pediatric hospitals within the United States. PATIENTS: Patients less than 18 years on venoarterial extracorporeal membrane oxygenation who underwent left atrial decompression from 2004 to 2016. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 137 patients (median age, 4.7 yr) were included. Cardiomyopathy was the most common diagnosis (47%). Cardiac arrest (39%) and low cardiac output (50%) were the most common extracorporeal membrane oxygenation indications. Median time to left atrial decompression was 6.2 hours (interquartile range, 3.8-17.2 hr) with the optimal cut-point of greater than or equal to 18 hours for late decompression determined by receiver operating characteristic curve. In univariate analysis, late decompression was associated with longer extracorporeal membrane oxygenation duration (median 8.5 vs 5 d; p = 0.02). In multivariable analysis taking into account clinical confounder and center effects, late decompression remained significantly associated with prolonged extracorporeal membrane oxygenation duration (adjusted odds ratio, 4.4; p = 0.002). Late decompression was also associated with longer duration of mechanical ventilation (adjusted odds ratio, 4.8; p = 0.002). Timing of decompression was not associated with in-hospital survival (p = 0.36) or overall survival (p = 0.42) with median follow-up of 3.2 years. CONCLUSIONS: In this multicenter study of pediatric patients receiving venoarterial extracorporeal membrane oxygenation, late left atrial decompression (≥ 18 hr) was associated with longer duration of extracorporeal membrane oxygenation support and mechanical ventilation. Although no survival benefit was demonstrated, the known morbidities associated with prolonged extracorporeal membrane oxygenation use may justify a recommendation for early left atrial decompression.


Subject(s)
Decompression, Surgical/methods , Extracorporeal Membrane Oxygenation/methods , Heart Atria/surgery , Child , Child, Preschool , Decompression, Surgical/mortality , Extracorporeal Membrane Oxygenation/mortality , Female , Humans , Infant , Intensive Care Units, Pediatric/statistics & numerical data , Length of Stay/statistics & numerical data , Male , Retrospective Studies , Risk Factors , Time Factors
6.
Catheter Cardiovasc Interv ; 88(6): 902-911, 2016 Nov 15.
Article in English | MEDLINE | ID: mdl-27471092

ABSTRACT

BACKGROUND: Metallic endovascular stents are utilized off-label in congenital heart disease. Biodegradable stents (BDS) offer potential advantages in a growing child. We have previously reported double opposed helical (DH) BDS up to 6 mm diameter (DH-6). The objectives are to investigate the bench characteristics of larger 8 mm diameter BDS (DH-8) manufactured with increasing strut thicknesses and the inflammatory profile in a porcine model. METHODS: DH-8 were manufactured with strut thicknesses 0.10, 0.12, and 0.18 mm and mechanical testing performed. Stents were deployed into the infrarenal descending aorta (DAO) of nine minipigs. At insertion (nonsurvival = 2), 1 week (n = 2), 1 month (n = 2), and 9 months (n = 3) follow-up angiography, intravascular ultrasound and histopathology were performed. RESULTS: There was superior recoil and collapse pressure with increasing strut thickness, with 0.18 mm having 1.0% elastic recoil and collapse pressure 0.75 Atmospheres. There was good wall apposition at insertion with 5 BDS (4 DH-8 and 1 DH-6) but suboptimal in 4 as the minipigs infrarenal DAO were >8 mm (deployed at iliac bifurcation). Structural integrity was maintained in 8 BDS with 1 DH-8 collapsed at 9 months, secondary to strut damage at insertion. No thrombosis was seen. There was mild inflammation and neointimal proliferation at 1 week and 1 month, but a moderate inflammatory response at 9 months. CONCLUSIONS: DH-8 with increased strut thickness had acceptable mechanical properties at the cost of an increased inflammatory response. Miniaturization to improve delivery and further investigation on the long-term inflammatory profile of thicker struts, including through degradation, is needed. © 2016 Wiley Periodicals, Inc.


Subject(s)
Aorta, Abdominal/surgery , Aortic Diseases/surgery , Drug-Eluting Stents , Endovascular Procedures/methods , Angiography , Animals , Aorta, Abdominal/diagnostic imaging , Aortic Diseases/diagnosis , Disease Models, Animal , Female , Follow-Up Studies , Prosthesis Design , Swine , Swine, Miniature , Tomography, Optical Coherence , Ultrasonography, Interventional
7.
Cardiol Young ; 26(7): 1441-4, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27322920

ABSTRACT

Pulmonary sequestration is a rare congenital anomaly that can be asymptomatic or present with recurrent infections, respiratory symptoms, or rarely heart failure. Sequestration is classified as intralobar or extralobar on the basis of whether there is separation from normal lung tissue by its own visceral pleura. Classically, patients are treated with surgical resection. We present a case of multivessel, combined intralobar and extralobar pulmonary sequestration treated with transcatheter embolisation.


Subject(s)
Bronchopulmonary Sequestration/diagnostic imaging , Bronchopulmonary Sequestration/surgery , Cardiac Catheterization/methods , Embolization, Therapeutic/methods , Septal Occluder Device , Child, Preschool , Computed Tomography Angiography , Echocardiography , Female , Humans
8.
Cardiol Young ; 26(8): 1568-1572, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28148330

ABSTRACT

Recently, three-dimensional printing of heart models is being used to plan percutaneous and surgical interventions in patients with CHD. We describe a case where we used a three-dimensional print model to plan a complex percutaneous intervention in a patient with coarctation of the aorta.


Subject(s)
Angioplasty, Balloon/methods , Aorta, Thoracic/diagnostic imaging , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/therapy , Printing, Three-Dimensional/statistics & numerical data , Computed Tomography Angiography , Humans , Male , Models, Cardiovascular , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL